Executive Engineer Electric Division UdhampurJPDCL
Executive Engineer Electric Division JPDCL Udhampur
Creation of 100 KVA Sub Station and 250 KVA Substation along with HT Line
2023_PDD_201657_1
ED/UDH/87 OF 2022-23 dt 05/01/2023
Open Tender
Electrical Works
Turn-key
90 days
in district Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division UdhampurJPDCL
₹52,000
27 Apr 2023
5 Jan 2023
28 Jan 2023
5 Jan 2023
27 Jan 2023
5 Jan 2023
5 Jan 2023 - 12 Jan 2023
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at Sundrani Stage-Zero.
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR conductor
PG Clamps for 30mm² ACSR conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20mm, 2.5 mtr. Long through G.I Strip 25x3mm
Painting of ST poles 9 mtr. with Red oxide
Painting of ST poles 9 mtr. with Aluminium paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 715 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 100 KVA at WSS Garhi Sundrani Stage-Zero.
11/0.433 KV, 3-phase distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting.
GI Channel /Angle/flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT distribution box for 100 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clmaps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-phase Trivector meter with CT, PT unit
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 1 coat of Red oxide & 2 coat of Al. paint
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at Sundrani (Intake)
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30 mm² ACSR conductor
PG Clamps for 30mm² ACSR weasel conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of ST poles 9 mtr. with Red oxide
Painting of ST poles 9 mtr. with Aluminium paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 250 KVA Filter at WSS Garhi Sundrani (Intake).
11/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 Copper Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical type
11 KV Horn gap fuse set 3 phase 200 A
300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT distribution box for 250KVA DTR with MCCB for incomer and SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clmaps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-phase Trivector meter with CT, PT unit
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 1 coat of Red oxide & 2 coat of Al. paint
Supply of Aluminium Ladder 10 feet heavy duty
Supply of Aluminium Ladder 20 feet heavy duty
Supply of safety helmets as per releavant IS/ISI Marked (ISI 2925))
Supply of safety shoes as per releavant IS/ISI Marked
Supply of safety gloves as per releavant IS/ISI Marked (33000/7500 volts)
Supply of 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
Supply of Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
Supply of 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical type
Supply of 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Supply of 11 KV Operating rod ISI Marked
Supply of 11KV Earthing /Discharge Rod (as per relevant IS ) for earthing of line (Set of 3)
M/S SHAH CONSTRUCTION
KULBUSHAN KUMAR
AJAY KAPOOR
Parbat and Sons
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .