Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹22.3 L+₹33,154 (1.51%)Rejected-Finance | L2 | Rejected-Finance Not L1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
18 Apr 2020, 6:00 pmClosed
GE Central
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
REPAIR/RENEWAL TO INTERNAL ELECTRIFICATION AND CONNECTED WORKS OF ASC CENTRE AND COLLEGE AREA AND STN WKSP EME AND DOMLUR AREA UNDER GE (CENTRAL) BANGALORE
2020_MES_332996_2
8908
Open Tender
Civil Works
Item Rate
180 days
Bangalore
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Central
₹44,000
Yes
5 Sept 2020
26 Mar 2020
20 Apr 2020
27 Mar 2020
18 Apr 2020
6 Apr 2020
27 Mar 2020 - 9 Apr 2020
Amount
Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic conduit on surface conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :- One light point controlled by one 5 Amps switch one way
One fan point controlled by one 5 Amps switch one way
One bell point controlled by one switch
One 3 pin socket point 5 Amp on independent board
One 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 2 above but with 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Point Wiring with 1.5 Sqmm (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping with Accessories (size of Casing and Capping as required at Site) including 1.50 Sqmm PVC ins-ulated Stranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and MS terminal box with 3mm thick masonite laminated sheet top cover fixed on Wall for one light and fan point controlled by one switch complete all as specified and as directed are as follows :- One light point controlled by one 5 Amps switch one way
One fan point controlled by one 5 Amps switch one way
One 3 pin socket point 5 Amp on independent board
One 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 4 above but with 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Havell/Polycab
Supply and fix bell push, flush button single pole, 5 Amps one way. Make : Anchor/Havell/Polycab
Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Havell/Polycab
Supply and fix Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Havell/Polycab
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Havell/Polycab
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks. Make : Anchor/Havell/Polycab
Supply and fix in repair Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Havell/Polycab
Supply and fix in repair Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Havell/Polycab
Supply and fix in repair Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Havell/Polycab
Supply and fix in repairs modular switch 1 way 6A,1 module Make : Anchor/Havell/Polycab
Supply and fix in repairs modular switch 1 way 16A,1 module Make : Anchor/Havell/Polycab
Supply and fix in repairs socket, 6A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix in repairs socket, 6A/16A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix in repairs moduler fan Requlator, 120 W-2 modules
Supply and fix in repair Door bell electronic, music type, 230 volt AC. Make : Anchor/Havell/Polycab
Supply and fix in repair Fan capacitor 2.5/3.15 mfd suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Havell/Polycab
Supply and fix in repair Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Havell/Polycab
Taking down old un serviceable/serviceable light fittings of any type from wall all as directed by Engr in Charge
S&F in replacement LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
Supply and fix in repair 30 watt LED Light 2' x 2' LED luminare with polymer diffuser complete with accessories suitable for armstrong/Grid ceiling with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Shakti/Bajaj/CG/Phillips
S&F inrepair bldg security light light fittings 1x 15 Watt LED street light with cast aluminium housing, toughened flass diffuser, IP65/66 and wired with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size all as specified and directed. Make Shakti/Bajaj/phillips/CG
S&F in replacement security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 4 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 4 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
All as per item No 30 here-in before but SPN 8 ways DB.
Supply and fix in replacement MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
fixing only MCB single pole 6 to 32 Amps any capacity
Supply and fix in replacement MCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix in replacement MCB Tripple pole & neutral 32 to 63 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
Supply and fix in replacement MCB Tripple pole 32 to 63 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
AC Circuit Breaker 100 Amps,4 pole , 10 KA Rupturing capacity,CE Marked as per IS/IEC 60947, IP 20 oprating voltage 240V/415V AC 50 Hz.Cat No 811244 Make: IndoAsian-optipro or eqivalent in Havells /Le-grand/standard
Supply and fix in replacement Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed.
Supply and fix in replacement Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed.
S & F in repair ballast electronic type for 4x14 Watt FTL complete all as directed. Make Shakti/Havells/Bajaj/Crompton
S & F in repair ballast electronic type for 1x28 Watt FTL/CFL complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair ballast electronic type for 1x36 Watt FTL/CFL complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair florecsent tube rod 1x14 Watt, 65000K, high efficiency /high out put complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair florecsent tube rod 1x28 Watt, 6000K, high efficiency /high out put complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair florecsent tube rod 1x36 Watt, 6000K, high efficiency /high out put complete all as directed. Make Havells/Bajaj/Crompton
Taking down ceiling/exhaust fan dismantling and painting of ceiling/exhaust fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as directed
Rewinding of Exhaust fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
Rewinding of ceiling fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
S & F ceiling fan hook made out of MS flat 50 X 6 mm thick suitable for hanging of ceiling fan including nuts, bolts and washer with 12 mm dia round bar hook complete all as specified and directed after taking down old one
S & F in repair starter for tube light fitting complete all as directed. Make Philips/Bajaj/Crompton
S & F in repair of earth plug enclosure(single pole and neutral) with a two pin and earth plug and socket complete with one single pole MCB.
S & F in repair of round surface mounted LED flat panel. PDC aluminium housing and PMMA diffuser makes it a robust Luminaire, 18W CDL. Make - CG/Havells/Philips/Bajaj.
M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 6mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified.
RAMSON TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .