Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.4 L+₹47,230 (9.59%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹5.9 L+₹94,680 (19.2%)Rejected-Finance C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹6.2 L+₹1.3 L (26.8%)Rejected-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹6.3 L+₹1.4 L (27.4%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
8 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
Garrison Engineer, Faridkot Military Station, Faridkot, Punjab 01639-264982
Misc Maint of Electrification related works at various locations under GE Faridkot Mil Stn
2022_MES_506572_1
GE FRD-72/2021-22
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class E Category b(i)
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹20,000
Yes
31 Mar 2022
8 Feb 2022
10 Mar 2022
8 Feb 2022
8 Mar 2022
23 Feb 2022
60 days
Amount
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit of suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for One light point/ fan point/ exhaust fan point to be controlled by one number one way switch complete all as specified and directed .
All as per Srl item No. 02 here-in-before but for one ligh point controlled by two,two way switches complete all as specified and directed
All as per Srl item No. 02 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed
All as per Srl item No. 02 here-in-before but for one switch socket combination, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed
All as per Srl item No. 02 here-in-before but for one bell point controlled by one bell push complete all as specified and directed
All as per Srl item No. 02 here-in-before for switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5 Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed .
S&F in replacement PVC Lamp holder with back plate suitable for batten fittings complete all as specified and directed .
S&F in replacement complete set of tube light fitting, 1x20 watt LED (4 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed . Havells Cat Part No LUMILINEBS20WLED865SPCWH/Bajaj Cat Part no 830379 20WCDL/Crompton Cat Part No LDLL20-CDL
S&F in replacement complete set of tube light fitting, 1x10 watt LED (2 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed . Havells Cat Part No LHEXACP7IN1W010/Bajaj Cat Part no BCLSB 10W/Crompton Cat Part No LDLL10-CDL
S&F in repair 1X10 watt LED retrofit type bulk head fitting luminaries, die cast, aluminium alloy body, heat resistant, prismatic glass cover with specially designed gasket, lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 HZ complete all as specified and directed.
S&F in replacement ceiling rose, three terminals, PVC polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed..
S&F in replacement Submain wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 10 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 10Sqmm for continous earth wire drawn into and including concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 10 Sqmm copper cable and one run of 10 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F in replacement Submain wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 6 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 6Sqmm for continous earth wire drawn into and including concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 volts, AC supply complete all as specified & directed
S&F socket outlet, two-in-one, 5 pin, 5 Amp, 230 volts, AC supply complete all as specified & directed
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230 volts AC supply complete all as specified and directed
S&F Piano type switch, single pole, 2 way, 5/6 amps, 230 volt, AC supply complete all as specified and directed
S&F bell push, flush type, 5 amps complete all as specified and directed
S&F Bell, ding dong, AC 230V, single pole complete all as specified and directed
S&F socket outlet ,2 in 1, 5/6 pin, 15/16 Amps, 230 volts ,AC supply complete all as specified & directed
S&F in repalcement Piano type switch single pole 1 way 5/6 amps 230 volt AC supply complete all as specified and directed.
S&F in repalcement Socket two in one 5 Pin 5 Amps 230 volt AC supply complete all as specified and directed.
S&F in replacement Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified and directed.
S&F in replacement socket outlet ,2 in 1, 5/6 pin, 15/16 Amps, 230 volts ,AC supply complete all as specified & directed
S&F in replacement Sheet metal enclosure for DBs,TPN, double door, 415 Volts, 4 ways, vertical type and space for MCCB complete all as specified and directed .
S&F in replacement Sheet metal enclosure for DBs,SPN, double door, 230 Volts,8 ways with 200 amps rated bus bar complete all as specified and directed .
S&F in replacement MCCB 3 Pole, fixed type ,415 V, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F in replacement MCB SP 5 to 32 Amp, 230 volts, B Curve with breaking capacity 10 KA complete all as specified and directed
S&F in replacement MCB, SPN, 32 amps, 230V, C Series with breaking capacity 10 KA complete all as specified and directed
S&F in replacement MCB SP 40 Amp, 230 volts, B Curve with breaking capacity 10 KA complete all as specified and directed
S&F in replacement for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 1000 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
S&F in replacement stepped type electronic fan regulator, flush type on the existing pheonolic laminated sheet etc, single phase, AC supply, 230 V and connecting up complete all as specified and directed .
Excavation in trenches in soft/loose soil not exceeding 1.5m deep and 1.5m wide, for foundation etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling,watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed .
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and brick cover for protection of cable shall be measured and paid separately.
S&F in replacement GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
S&F in replacement sheet metal enclosure wih socket plug top and MCBs 20 Amp, 240 V, AC Supply, Single Pole and neutral enclosure with a two pin and earth plug with socket complete all as specified and directed .
S&F in replacement Modular switch 1 way 16 amps, 1 module complete all as specified and directed.
S&F in replacement Modular socket 6A /16A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F in replacement Modular switch 1 way 6 amps, one module complete all as specified and directed.
S&F in replacement Modular switch 2 way 6 amps, two module complete all as specified and directed.
S&F in replacement Modular bell push 6 amps, one module complete all as specified and directed.
S&F in replacement Modular socket 6A -2/3 pin combined, 2 module complete all as specified and directed.
S&F in replacement modular metal flush box 1/2/3 modules including making good to disturbed area duly matching the colour with existing surface complete all as specified and directed.
S&F in replacement modular metal flush box 4 modules including making good to disturbed area duly matching the colour with existing surface complete all as specified and directed.
S&F in replacement Modular white cover plate with frame, 1 module complete all as specified and directed.
S&F in replacement Modular white cover plate with frame, 2 module complete all as specified and directed.
S&F in replacement Modular white cover plate with frame, 3 module complete all as specified and directed.
S&F in replacement Modular white cover plate with frame, 4 module complete all as specified and directed.
S&F in replacement Modular white cover plate with frame, 6 module complete all as specified and directed.
S&F in replacement Modular white cover plate with frame, 8 module complete all as specified and directed.
S&F in replacement condenser 2.5 Mfd AC 240V, complete all as specified and directed. Note :- A Sum of Rs. 34634.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 19 (Schedule of credit) of Tender Documents.
M/S BSS AND SONS
DEEPAK ENTERPRISES
SUNRISE ENGINEERS AND CONTRACTOR
M/S RAJESH KUMAR and CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .