Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹18.3 L+₹97,016.50 (5.60%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹23.7 L+₹6.4 L (37.0%)Rejected-Finance | L3 | Rejected-Finance Not being lowest |
Tender Value
₹34.4 L
EMD Value
₹68,800
Closing Date
2 Oct 2023, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
REPAIR ,MAINTENANCE OF LT OH LINES, UG CABLES, MCCB,MAIN SWITCHES,LT PANEL BOARD,POLE PAINTING, EARTHING AND ALLIED WORKS TO TECH DOMESTIC AREA AND ANNUAL MAINTENANCE TO AIRCOMPRESSOR AT O I LEVEL HANGAR AT AF STATION TAMBARAM
2023_MES_616367_1
GE(AF)/TBM/8662/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹68,800
Yes
29 Nov 2023
30 Aug 2023
4 Oct 2023
30 Aug 2023
2 Oct 2023
15 Sept 2023
31 Aug 2023 - 6 Sept 2023
Amount
Excavation in trenches not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out in hard/dense soil for laying cable, foundation for pole etc complete
All as per item No. 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3.0 metre deep.
Returning filling in soil including providing cable cushioning with riddled earth obtained from excavation, leveling watering and well ramming in layers not exceeding 25cm thick over the cushion layer all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified directed.
Relaying of old serviceable bricks of any size removed from old cable trenches laid across trenches for cable protection.
M&L for plain cement concrete 1:4:8, type D2, using 40 mm graded stone aggregate for foundation, filling and mass concrete all as specified and as directed
M&L for plain cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate as in foundation/ coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair all as specified and as directed
M&L for Straight through joints suitable for 3.5/4 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits complete for making joints all as specified and as directed for the following : - Make :- Raychems / Densons / M-Seal /Birla-3M / CCI / Siemen
3.5/4 core cable 6 to 16 Sq mm.
3.5/4 core cable 25 to 50 Sq mm.
3.5/4 core cable 70-120 Sq mm
3.5/4 core cable 150-185 Sq mm
3.5/4 core cable 240-300 Sq mm
M&L for End termination indoor/out door heat shrinkable joint kits suitable for 3.5/4 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits complete for making joints all as specified and as directed for the following : - Make :- Raychems / Densons / M-Seal /Birla-3M / CCI / Siemen
3.5/4 core cable 25 to 50 Sq mm.
3.5/4 core cable 70-120 Sq mm
3.5/4 core cable 150-185 Sq mm
3.5/4 core cable 240-300 Sq mm
M&L for Sepatating pick and stacking stone aggregate spread in the installation yard of transformer/two/four pole structure aside for re use cleaning surface free from vegetation, grass etc.., all as directed by Engineer -in-Charge.
Supply and spread 20/40mm graded stone aggregate as approved quality for installation yard all as directed.
M/L for ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps ACB 4 pole, 50 KA ruptaring capacity ,415 volts fixed overload & fixed short circuit setting including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface of capacity 800A complete all as specified and directed.
M&L for cutting, removing the vegetation growth and surface dressing all around the installation yard including 4/2 pole structure area to keep the installation area (external only) clean and tidy. Note :- All the sub station yards shall be kept clean through out the contract period by repeatedly removing the grass/ however weeds as and when ordered by Engineer-in-charge depending on the growth of the grass, however this item shall be measured and paid only once during entire contract period.
M&L for cutting chases on concrete surfaces for concealed GI tubing/HDPE pipe, girth exceeding 10 cm but not exceeding 20 cm ,making good to facing and disturbed surface in cement morter 1:3 and finished as per existing all as directed.
Taking out the existing LT UG cable of any description of following size to find out the fault and re-laying the serviceable LT UG cable 1100 Volts grade PVC insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including necessary lugs/thimble/ferules connection, testing and commissioning complete all as specified. Note: [a] Earth work, excavation sand cusioning, bricks for protection, GI pipe, LT UG Cable Joints etc shall be measured separately under relevant items of this schedule . [b] Defective portion of cable shall be removed, serviceable cable shall be re-laid and balance with new LT U/G cable .(C) New LT UG cable shall be measured and paid as Supply only LT UG cable under schedule /BOQ item No 17 of this schedule.
10 sqmm to 16 sqmm 2/4 core
25 sqmm to 35 sqmm 3.5 core
50 sqmm to 120 sqmm 3.50 core
150 sqmm to 240 sqmm 3.50 core
Supply and laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning and taking out old UG cables complete for the following sizes. Note: [a] Earth work, excavation sand cusioning, bricks for protection, GI pipe, LT UG Cable Joints etc shall be measured separately under relevant items of this schedule .
10 sqmm 2 core
16 sqmm 2 core
16 sqmm 4 core
25 sqmm 3.5 core
50 sqmm 3.50 core
70 sqmm 3.50 core
95 sqmm 3.50 core
120 sqmm 3.50 core
185 sqmm 3.50 core
240 sqmm 3.50 core
300 sqmm 3.50 core
10 sqmm 4 core
6 sqmm 2 core
M&L for GI tubing 'Light' grade with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area for following sizes of pipes :-
For 40 mm Bore
For 50 mm Bore
For 80 mm bore
For 100 mm bore
M&L for MCCB 4 pole, 415 volts fixed overload & fixed short circuit setting including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. including taking out the existing unserviceable MCCB and making good the disturbed surface for following capacity.
160 Amps with breaking capacity 25 KA
200 Amps with breaking capacity 36 KA
250 Amps with breaking capacity 36 KA
320 Amps with breaking capacity 36 KA
400 Amps with breaking capacity 36 KA
630 Amps with breaking capacity 65 KA
100 Amps with breaking capacity 16 KA
125 Amps with breaking capacity 25 KA
63 Amps with breaking capacity 16 KA
M&L for Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including dismantling of old type of poles any length , complete all as specified and directed. Note : Excavation & earth work and PCC shall be measrued and paid separately.
M&L for painting the existing steel tubular LT poles, 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
M&L for cutting, trimming and prunning of trees/tree branches of any girth upto 4m all around existing LT/HT over head lines including cleaning the disturbed area beneath the LT/HT overhead lines and removing the tree/ tree branches and debris from at site and depositing where directed at site. Note: (a) This item shall be measured and paid only once during entire contract period , however each span of LT over head line shall be clear from tree branch growth through out the contract period seperately. (b) Cutting trimming, prunning of tree / branches shall be carried out as and when ordered by Engineer-in-chrage depending on growth of tree (c) Approximate span between poles shall be 45m to 60m.
Taking down old serviceable conductors any description and re-stringing/ tightening of ACSR conductor (size- squirrel/ weasel/ ferret) / GI earth continuity conductor/ cradle up to the permissible sag limit between any span length and binding the with new binding wire of the same materiel to insulators all as specified and as directed. Note :Approximate span between poles shall be 45m to 60m.
Dismantling old and unserviceable ACSR conductor of any size / including disconnecting from the poles and depositing where directed.
Supply & fixing ACSR conductor of any size including binding on existing LT/ HT poles or new poles with 2mm dia aluminium binding wire including jumper all as specified & directed . Make of ACSR : ICC/ NICCO/ BHARAT CONDUCTORS / Indian Aluminium Co.
Supply, fabricating and fixing mild steel cross arms (any type) supports, bracing stiffner etc made out of MS channel, angle iron , flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint and taking down the existing all as directed.
Supply and fix Galvanised steel wire, 4mm dia, as in earth continuity conductors/ guarding cradles for LT OH line including taking out old unserviceable and making good the disturbed surfaces all as specified and directed.
Supply and fix, shackle type porcelain vitreous white, green or brown insulators for working pressure 1100 volts, 90mm dia 75mm height including removal of existing insulators. Make :- MYSORE/ BHEL/ PORCELAIN / JAIPURIA BROS / Jayshree / WS Insulators
M&L for stay assembly complete with all accessories as shown in Electrical plate No. 1 of SSR Part-I all as specified and as directed including GI stay rod 20 mm dia 2150 mm long, MS stay plate of size 300 x 300 mm, 6mm thick GI stay bow including necessary bolts & nuts etc complete. Note : Excavation, foundation concrete, stay wire, clamps and loop insulator shall be measured and paid separately.
M&L for galvanised stay strand 7/ 3.15mm all as specified
M&L for pin type insulator, porcelain, vitreous, white, brown or green insulator of size 100 mm height, 65 mm dia for 1100 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron bolt including taking out the old unserviceable insulator and making good the all as specified and as directed. Make :- MYSORE/ BHEL/ PORCELAIN / JAIPURIA BROS / Jayshree / WS Insulators
M&L for M&L for loop type insulator, porcelain vitreous white or brown, with overall dimensions of 65mm x 90mm, clearance of hole 16mm all as specified and as directed including taking out old unserviceable insulator. Make :- MYSORE/ BHEL/ PORCELAIN / JAIPURIA BROS / Jayshree / WS Insulators
M&L for removing old/burnt out jumper connection in binding with HT/LT lines from position including re-binding the same with new binding wire of size 3.25mm aluminium wire all directed.
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 32mm x6 mm GI strip means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover, 50mm thick in cement concrete 1:2:4 type B1 with 6mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt, GI pipe 40mm dia for protest GI strip connected to earthing test point all as specified including testing and commissioning on completion all as specified and directed.
Taking out old U/S earthing incl all connected items, Material and labour for earthing complete with copper earth plate electrode 600x600x3.15mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 20x3 mm copper strip means of bolts, nuts, washers, incl GI protection pipe 40mm size light grade all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work, levelling of ground level. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion all as specified and directed.
Supply and fixing insulating rubber mat of 1 mtr x 2 mtr x 2.5 mm thick all as specified and directed.
S&F of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters,figures and conventional skull and bones in single red colour and fixed with M S clamps, nuts and bolts of approved size, for HT, 25 x 20 cm size inculding taking down of old unserviceable complete all as specified and directed.
Supply and fix automatic transfer switch execution rated voltage 415V AC 50 HZ type FP 200 Amps all as specified and directed by the Engineer-in-charge including taking down existing main switches Make : Havells cat part No IHYFCDO200 or its equivalent make from list of makes.
Supply & fixing off load changeover switch with enclosure execution rated voltage 415V -AC 50 HZ type TPN all as specified & directed by the Engr-in-charge including taking down existing main switches directed for 63 Amp
All as per Sl.item No. 40 above but for 200 Amps
Supply & fixing in repairs 400 Amp Euroload for pole changeover with sheet enclosure advance neutral on load changeover switch open execution rated voltage 415V -AC 50 HZ type FP all as specified and directed
M&L for servicing to indoor/outdoor LT panel board installed at AFS Tambaram, opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable instruments, copper wiring kit, and burnt out unserviceable extented copper terminals/ copper cable and replacing with new copper extented terminal bus bar with suitable size along with required nut bolt, washers, and replacing the measuring instruments like Ammeter with existing size of the CT, Volt meter, indicating lamps of LED type 'R Y B' cleaning with CTC to serviceable parts like MCCB's, all terminals, replacement of damaged aluminum lugs any description of LT U/G cables in coming and out going, welding of broken door with suitable hinges, replacement of deterioated copper wiring with suitable copper conductor with circuit indicator replacement of sheared rubber beadings to door of panels, including preparing the existing surface for spray painting to powder coated surface with two coat of synthetic enameled paint of approved colour, marking of incoming and out going feeder with fluorecent stickers incl preparation of the surface of panel complete all as specified and directed.
Supply Only Volt meter digital type 0 - 500 Volts
Supply Only Amp meter digital type 0 - 500 Amp
Supply Only Aluminium legs suitable for 70 sqmm to 150 sqmm cables
Supply Only Aluminium legs suitable for 185 sqmm to 300 sqmm cables
Supply Only Aluminium legs suitable for 25 sqmm to 50 sqmm cables
Supply only Indicator lamp LED type 'R' 'Y' 'B'
Supply only CT coil of size 4x4 ratio 100/5 Amps
Annual Maintance contract for a Air compressor model EG90-9,415 V 50HZ, motor capacity 90 Kw ,Capacity 15.23 sqm /Min with rated pressure 8.0 Bar, Refrigerator air dryer Model No ELRD-750A working pressure 16kg/ Sq cm , capacity 750 CFM.and air tank model VA001203000L 10ASME 2062 (Make:- ELGI) (a) Check and ensure the oil level and quality of oil. (b)Check and ensure there is no air and oil leakage in the compressor package. (c) Check,clean and change the air filter. (d) Check oil and oil filter at recommended intervals. (e) Check and replace oil seperators element at recommended intertval. (f) Check and ensure the operation of the safety valve against the set pressure. (g) Check and ensure all the quick coupling fittings and flexible hoses are intact.(h) Check and ensure the proper fuctioning of all valves in the compressor package and replace the service kits. (j) Check and clean the oil and after coolers interally if required.(k)Check and ensure the proper fuctioning of the auto drain valve and clean/ change as required. (l) check and ensure the proper fuctioning of all the satey switches.(m) Check and ensure the proper functioning and condition of electrical contrators.
Sl.item No. 52Contd/.. : (n) Check and ensure the proper fuctioning of all safety interlocking devices. (o) Conduct diagnostic testing of the controller. (p) Check the compressor operating enviroment and recommended revalant corrective action for reliable operation of the compressor. (q) Study and recommend upgrade kits. (r) Submit the compressor Performance /Health Checks report .Note: Servicing/Repairing of Air compressor specified above shall be carried out through OEM /reputed authorised service Engineer.
Supply only Oil Filter element -75 (Make:- ELGI Cart Part No :-B004800770001)
Supply only ELGI Air lube syn-plus oil (Make ELGI Cart Part No :-0009981024)
Supply only service kit for HDKG120(Make ELGI Cart Part No :-B009401070002)
Supply only Grease EMUNIREXN3(Make ELGI Cart Part No :-015404151)
Supply only Service kit for VVF15 BDV No (Make ELGI Cart Part No :-B009401070003)
Supply only Solenoid valve NC,24V 50 Hz (Make ELGI Cart Part No :-B007300990004)
Supply only Auto drain valve -F3 (Make ELGI Cart Part No :-B000306040013)
Supply only DRIVE COUPLING INSERT UCW276(Make ELGI Cart Part No :-B005401170005)
Supply only SINGLE ACTING ACTUATOR HOERBIG(Make ELGI Cart Part No :-B0115010700001)
Supply only FILTER ELEMENT F5(Make ELGI Cart Part No :-B004700770029)
Supply only AIR OIL SEPERATOR 90-110KW(Make ELGI Cart Part No :-B006700770023)
Supply only PREFILTER 90-160KW(Make ELGI Cart Part No :-B000606160001)
Supply only THERMAL ELEMENT 80 DEG CELCIUS(Make ELGI Cart Part No :-B008706030009)
Supply only MPV WITH CHECK VALVE -MPVL65(Make ELGI Cart Part No :-B009301070003)
Supply only MJ81BK(110-240VAC),GIS Make :-(Make ELGI Cart Part No :-018362741)
Supply only NON Return Valve 1/8 "(Make ELGI Cart Part No :-B004100170001)
SJM CONSTRUCTIONS
M/s Bakiyalakshmi Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .