Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹15.6 L+₹67,200 (4.51%)Rejected-AOC | L2 | Rejected-AOC BEING OTHER THAN L1 | |
| 3 | L3₹16.7 L+₹1.8 L (12.1%)Rejected-AOC | L3 | Rejected-AOC BEING OTHER THAN L1 | |
| 4 | L4₹16.7 L+₹1.8 L (12.3%)Rejected-AOC | L4 | Rejected-AOC BEING OTHER THAN L1 | |
| 5 | L5₹16.8 L+₹1.9 L (12.8%)Rejected-AOC | L5 | Rejected-AOC BEING OTHER THAN L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
REPAIRS TO INTERNAL ELECTRIFICATION MCBs DBs IN MD ACCN AT GE (AF) AWANTIPUR
2023_MES_632682_1
GE (AF) AWA-40/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹50,000
Yes
30 Mar 2024
14 Dec 2023
6 Jan 2024
14 Dec 2023
4 Jan 2024
29 Dec 2023
Amount
Taking down carefully aluminium/copper point wiring (light, bell, fan, socket) complete including batten/casing caping/conduit, block, ceiling rose, holder, fittings and terminal box sheets complete, stacking material at site and making good the disturbed surface of walls/ floors to match with existing surface, complete all as specified and directed.
M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated, sheathed, FRLS type, 1100 volts grade,1.5 sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal boxes of suitable way with 3 mm thick laminated sheed cover for mounting of switches, socket, fan regulators, connected to common earth dolly complete all as specified for the following:-
(a) One light /fan/bell point controlled by one nos, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp on the same board controlled by one nos, one way switch.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent controlled by one nos, one way switch.
All as per srl item No 2.00 here-in-before but using cable of size 2.5 sqmm (for phase & neutral) and 1.5 sqmm as continuous earth cable for 15/16 Amps socket outlet, independent controlled by one nos, one way switch, complete all as specified and directed.
S&F in replacement of piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and directed.
S&F in replacement of piano type bell push switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and directed.
S&F in replacement of piano type socket outlet flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and directed.
S&F in replacement of piano type switch socket combination flush type, 6 pin, 5/15 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and directed.
S&F in replacement of electronic type ceiling fan regulator, 230 volts, single phase, flush type, complete all as specified and directed.
S&F in replacement of ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body 230 volts AC, 50 Hz, complete all as specified and directed.
S&F in replacement of electric call bell ding dong type suitable for 230 volts, single phase AC supply, complete all as specified and directed.
S&F in replacement of electric call bell ding dong type remote controlled along with bell push and range upto 15 meters suitable for 230 volts, single phase AC supply, complete all as specified and directed.
S&F in replacement of batten holder PVC/polycarbonate with cord grip, B-22 base type suitable for LED bulb, 230 volts AC, 50 Hz, complete all as specified and directed.
S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 4.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed.
S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in existing conduit along with 1x 6.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed.
S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed.
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete with & including one No. MCCB 100 Amps 3 pole 25 kA fixed type for incoming, complete all as specified and directed.
S&F in replacement of sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB TP/TPN as incomer & MCB SP as outgoing, complete all as specified and directed
S&F in replacement of sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing, complete all as specified and directed.
S&F in replacement of sheet metal enclosure DB SPN 12 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing, complete all as specified and directed.
S&F in replacement of sheet metal steel plug & socket DB SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, surface mounting type complete with one MCB SP, 20 Amps, 10 kA, complete all as specified and directed.
S&F in replacement of MCBs, SP, 6-32 Amps C Curve, 230 volts,10 kA rupturing capacity, C curve type, complete all as specified and directed.
S&F in replacement of MCBs, SPN, 40-63 Amps, C Curve, 230 volts, 10 kA rupturing capacity, C curve type, complete all as specified and directed.
S&F in replacement of MCBs, TPN, 63-100 Amps, C Curve, 415 volts, 10 kA rupturing capacity, C curve type, complete all as specified and directed.
Supply & fix in replacement of MCCB TP 100 Amp, 25 kA, 415 V microprocessor LSIG energy release complying with IEC 60947-2 frame size P160 microprocessor trip unit with LSIG protection, OLED display , multi function metering with accuracy class 0.5 for V&I adjustable overload with delay/short circuit with adjustable/ Ground Fault/ Instantaneous I2T On/Off for precise coordination , ZSI for intelligent discrimination, alarm managment system, complete all as specified and directed.
S&F in repairs of decorative laminated sheet 3 mm thick of size 10"x12" including necessary cutting of sheet for fixing switch/socket, complete all as specified and directed.
S&F in repairs of decorative laminated sheet 3 mm thick of size 8"x10" including necessary cutting of sheet for fixing switch/socket, complete all as specified and directed.
S&F in repairs of decorative laminated sheet 3 mm thick of size 7"x4" including necessary cutting of sheet for fixing switch/socket, complete all as specified and directed.
S&F in repairs of decorative laminated sheet 3 mm thick of size 4"x4" including necessary cutting of sheet for fixing switch/socket, complete all as specified and directed.
S&F in repair of PVC 3 Modular Gang box with cover plate of suitable module, complete all as specified and directed.
S&F in repair of PVC 4 Modular Gang box with cover plate of suitable module, complete all as specified and directed.
S&F in repair of PVC 6 Modular Gang box with cover plate of suitable module, complete all as specified and directed.
S&F in replacement FRLS PVC insulated unsheathed multi core stranded copper conductor cable of size 2.5 sqmm, 3 core LT 1100 volt grade, complete all as specified and directed.
S&F in replacement LED tube light fitting 1x20 watts, 220 volts AC, 1200 mm, with aluminium housing & integrated electronic driver complete with driver with polycarbonate diffuser & thd< 10% including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
S&F in replacement of LED bulk head light fittings weather proof, anti corrosion wall/ceiling mounted opel colour decorative, round shape with PC cover suitable for & including 7 watts LED lamp, lamp holders complete with all accessories, all as specified and directed.
S&F in replacement of LED tube light fitting, box type 230 volts AC suitable for & including 9/10 watts LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F in repair/ replacement of recess mounting LED luminaire 2x2 36Watts (warm white/cool white 5700K/ 4000K), 220 volts AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, holders & including suitable LED lamp suitable for POP/Gypsum/roof ceiling including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surfaces& matching with the existing surface including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessories, all as specified and directed.
S&F in repair/ replacement of recess mounted compact vertical, round shaped energy saving LED downlighter luminaire 10 watts, 4000 K, 230 volts, 50 Hz complete with suitable LED driver lamp & all accessories internally prewired & including connecting up with three core twisted flexible copper conductor cable of suitable size including cutting of suitable hole in false ceiling, complete all as specified and directed.
S&F in repair/ replacement of LED wall light fittings 6/7 watt, 230 volts AC, indoor type made up of polycarbonate complete with lamp holder , LED lamp 6/7 watts, 4000 K, LED driver, connector block pre wired with all accessories all as specified.
S&F in repair/ replacement Inverter LED batten 20/22 Watt with Opal Diffuser, 6000 K IP 20, battery back up to 3 hrs & Functioning as per product TDS complete all including and connecting up including mounting with all accessories, complete all as specified and directed.
S&F in repair/replacement Inverter LED bulk head 10 Watt, IP 65 with Opal Diffuser, IP 20, battery back up & Functioning as per product TDS complete all including and connecting up including mounting with all accessories, complete all as specified and directed.
S&F in repair/ replacement Solar/Inverter LED building security light 30 Watt, IP 66 with battery back up, Auto on/off/dimm Functioning as per product TDS complete all including and connecting up including mounting including GI pipe of suitable dia and clamps, nut, bolts, washers with all accessories, complete all as specified and directed.
S&F in repair/ replacement of recess mounting INVERTER LED 2x2 panel CRCA powder coated, IP-20 with battery back up & Functioning as per product TDS 36Watts (warm white/cool white 5700K/ 4000K), 220 volts AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, holders & including suitable LED lamp suitable for POP/Gypsum/roof ceiling including connecting up with suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surfaces& matching with the existing surface including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessories, complete all as specified and directed.
S&F in replacement of 25 mm dia medium grade rigid non metallic PVC conduit alongwith its fixing accessories & making good to the disturbed surface to match with the existing surface, complete all as specified and directed.
S&F in replacement of 25x16 mm medium grade casing caping alongwith its fixing accessories & making good to the disturbed surface to match with the existing surface, complete all as specified and directed.
S&F in repair/ replacement inverter LED bulb 9W as per IS 16102 (Part-I &2) with emergency time 4 hours (battery back up with Li Ion battery ) base cap B22 D, with electronic driver, lumen maintenance for 50000 hours @ 70 insulated cu wire internal wiring and operating voltage from 140 v to 270 V, PF>0.9 system lumen efficacy ≥ 100 lumen/watt 6500 K, THD < 30%, complete all as specified and directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete all as specified and directed.
S & F in repairs, installation, commissioning and testing IP 65 Thermoplastic PC Polycarbonate weatherproof Meter Box for Provision of 3 Nos Meter with multi level knockouts for cable glands in different sizes. The Meter Box Mini. Size 300 x 600 x 170. The Meter Box with Bakelite sheet at the bottom of Meters and The Meter Box pre-moulded knockouts shall be available on top and bottom of the Meter box to enable cable entries from both direction. Front Door totally Transparant for vision of Meter Reading. The Meter box shall have an grooved cable entry with breakable metal seals at the bottom of the box via pre-moulded knockout to enable Wall mounting Type . Lid fasteners will be tool operated it will be sealable with accessories. The Meter box shall have elongated holes inside them for wall mounting provision. In the event of formation of condensed water, the meter box shall have a minimum of two condensation knock-outs inside to ensure optimum safe performance. The Meter box shall fulfill the following standards:- Weatherproof : Rainwater proof, temperature resistant. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. The Meter Box Should withstand glow wire test at 960C in accordance with IEC 60 695-2-11 UL subject 94, should be flame retardant and self-extinguishing in nature, so that fire should not be spread all over in the event of fire due to short circuit. . IEC 60529 : IP 65 degree of protection. UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4. Degree of protection against mechanical load IK 08 (5 Joule) in accordance with accordance with EN IEC 62262 Make- Hensel/Rittal/Emitter/Schneider/ABB.
Supply and fix includingTaking down corrugated/damaged garden light fitting Inverted pyramid tripod type LED bollard with soft 360 light (preferably 4000 K) IP 65 protection resistanace corrossion better optics for uniform distribution of capcacity 10w LED fitting of model Liara, complete all as specified and directed.
S&F in replacement electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data, time, current reading, load, PF, voltage and KWH, complete all as specified and directed. Make- HPL, L&T or equivalent
S&F in replacement post top lantern 35 W energy saving, environment friendly, long life aesthetically designed with good indirect symmetrical light distribution, die cast aluminium landscape IP65 rating with high power COB LED as light source along with its mounting accessories, complete all as specified and directed.
Dismantling old unserviceable earth pit including electrode plate/ pipe and material and labour for modern maintenance free marconite conductive concrete based technology earthing system with same or different place as directed with copper bonded earth electrode (03 metres) inluding backfill compound and other accessories as required and connecting with copper strip 25x3 mm (upto 7.5 mtr max) in position with HDPE pit cover all as specified and as directed and having following specifications:- a) Fixed Carbon 98.5 % b) Ash, Volatile and Water 1.5 % c) Sulphur Content 1.5% Maximum d) Size Grading (Approx) - 10% below 0.10 mm,5% above 3.15 mm, 85% between 0.10 mm and 3.15 mm (e) Thermal Stability Between{-) 10% and (+) 60% ambient temperature (f) Ultra Low Resistivity (g) Versatile - shall be suitable for all type of soil and climate (h) Consistent Performance (i) Chemically Inert (i) Non-corrosive (k) Maintenance free and life span.
M&L for replacement High Bay LED light 100 W Next generation, energy saving, environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/W including mounting with all accessories upto height not more than 12 mtrs including connection with suitable termination, complete all as specified and directed.
M&L for laying of XLPE PVC sheathed armored cable 25 sqmm 4 core, complete all as specified and directed.
M&L for laying of in replacement XLPE PVC sheathed armored cable 35 sqmm 4 core, complete all as specified and directed.
M&L for excavation in trenches in soft/loose soil not exceeding 1.5 m in depth and width and getting out, complete all as specified and directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
M&L for removal of excess soil from site n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts, complete all as specified and directed. Note: For payment point of view, punned thickness of sand shall be measured.
M&L for brick laying with subclass 'B' bricks well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and directed.
Note :- An amount of Rs. 37666.50 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
ORISON ENTERPRISES
M/S PARVEZ AHMAD LONE
M/s M Ashraf and Brothers
M/S MIR SAJAD ENTERPRISES
M/s Jaipal Associates
Singh Associates
M/s Gh Qadir and Sons
MS Ghulam Hassan and Sons
M/S ABBAS M. ENTERPRISES
nazir Ahmad Dar and sons
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .