Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
9 Oct 2021, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
SPECIAL REPAIR OF BUILDING NO T74 T103 AND OTHER SANCTIONED WORKS AT DIFFERENT LOCATIONS OF KHREUH AND SHER E SHALI UNDER GE 861 EWS
2021_MES_474476_1
GE 861EWS-53/2021-2022
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹65,000
Yes
8 Nov 2021
11 Sept 2021
11 Oct 2021
11 Sept 2021
9 Oct 2021
26 Sept 2021
Amount
Taking down cement plaster on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed.
Demolition of cement reinforced concrete (reinforcement cut as required to facilitate demolition) in ground floors & pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed.
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but n exc n.exc 4 Sqm each, complete as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets etc, complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:4 complete all as specified and as directed.
15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed.
35 mm thick 2nd class hardwood plain (Sal/ Hollock) factory made, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats, complete all as specified and as directed.
30 mm thick, 2nd class hard wood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (b) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
300mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
Steel ventilator with top hung shutter incl hinges, steel peg stay, including one shop coat of red oxide primer, complete all as specified and directed, complete all as specified and directed.
200mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
100 mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
150mm long, floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Glazed ceramic coloured tiles 450mm x 300mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
Dismantling water storage tanks of any description, exceeding 500 litres but not exceeding 1000 litres and removing from site, complete all as specified and directed.
S&F for Rotational moulded polythylene 1000 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, complete all as specified and directed.
S&F in repairs 15mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,complete all as specified and directed.
15mm bore stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Steel water tubing, 15 mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting, chases, pinning for concealed work etc and making good disturbed surfaces in CM 1:3, complete all as specified and directed.
Steel water tubing, 20 mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting, chases, pinning for concealed work etc and making good disturbed surfaces in CM 1:3, complete all as specified and directed.
S&F in repairs 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 20mm dia with iron wheel head, both ends screwed for iron pipe including taking down of old one complete all as specified and directed for following bore of pipes.
S&F in repair 2nd class soft wood, weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps, complete all as specified.
Dismantling plain or corrugated steel sheeting , any gauge and thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-290 (Gde-E-165), complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of alkali-resistant priming paint, complete all as specified and directed.
Preparation of new plasetered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali-resistant priming paint, complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of cement base paint, complete all as specifed and directed.
Preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of old painted wooden surcaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
S&F for anodised aluminium snap grid of size 605 x605 mm frame work for false ceiling including Hangers 6 mm dia MS rod (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed.
S&F for 10 mm thick PVC insulation panels with EPS stuck to 1 mm thick plain PVC sheet suitably placed in false celing grid made of aluminim GI/MS as per specification and drawing complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
75mm thick, PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of floor, complete all as specified.
Chequered cement concrete tiles of size 200 x 200 x 25 mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
2nd class soft wood, plain, solid, straight chowkats and frames, wrought, framed, worught, framed rebated on the solid, rounded of chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
Preparation of old painted steel surcaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
2nd class hard wood, as in scantling and similar work, clean sawn, timber framed and fixed in position including dismantling, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Machine Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed
15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying 3mm thick wall care putty, complete all as specified and directed.
35 mm thick, 2nd class hard wood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed.
75 mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm & fixed with stainless steel wire staples, complete all as specified and directed.
10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets, complete all as specified and directed.
S&F in repair stainless steel grating doom 125mm dia, complete all as specified and directed.
PVC (SWR) pipes 75mm bore dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
PVC (SWR) bends 75mm bore dia complete all as specified and directed.
S&F in repair vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, jointing to flush pipe complete and making good to dismantled/damaged floor in cement concrete M-5 (1:5;10), type E-2 using 40mm graded crushed stone aggregate, complete all as specified and directed .
Vitreous china urinals, bowl type 465x355x265 mm white, providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with flush pipe, grating and union for discharge pipe complete all as specified and directed.
PVC (SWR) vent cowl for 75mm bore pipe and fixed, complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed.
Brick work with sub class 'B' bricks in half brick thick walls, built in cement mortar 1:4, complete all as specified and directed.
Plain cement concrete bed 1:4:8 type C-2 (using 40mm graded crushed stone aggregates)to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm bore pipe, complete all as specified and directed.
Salt glazed stone ware drain pipe of 150mm bore (internal bore) grade 'A' laid in trenches and jointed, complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
Surface dressing not exceeding 30 cm deep and averaging 15 cm getting out in hard/dense soil, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash,complete all as specified and directed.
Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Vitreous china, wash hand basin, white, flat back, of size 550mmx400mm with brackets including cutting for and pinning in ends of brackets and including 32mm dia PVC waste pipe, waste coupling and 15mm bore dia pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed, complete all as specified and directed.
4mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, including hacking out old glass panes, complete all as specified and directed.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each, and refixing in same opening, complete all as specified and directed.
Taking down shutters of any description not exceeding 1.00 Sqm each, and refixing in same opening, complete all as specified and directed.
300 mm long, mild steel helical door spring, including roller and roller plate enamelled black fixed to wooden chowkat, complete all as specified and as directed.
S&F in repairs curtain rod, chromium plated, 20mm dia, complete all as specified and directed.
S&F in repair designed CP brackets for curtain rod, complete all as specified and directed.
Vitrified tiles 10 mm thick, dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Vitrified tiles 10 mm thick, dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces such as skirting dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
Pre-polished 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone and including 10 mm thick screed bed in CM 1:4, as in repair, complete all as specified and as directed.
S&F in repair 2nd class hardwood, weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed, complete all as specified and directed.
0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap with zinc coating of 275, fixed with 'L' or 'J' type or cranked hook bolts in roofs, walls etc. complete all as specified and directed.
0.63mm thick , Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc, fixed with 'L' or 'J' type or cranked hook bolts in roofs, walls etc. complete all as specified and directed.
Preparation of new galvanised steel surfaces of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer over a coating of mordant solution including washing the surfaces, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.06 sqm but not exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 75mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
4 mm thick figured glass pin head type and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane, complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 600mm, complete all as specified and directed.
100mm cast iron sanitary connection socket to fit WC outlet, complete all as specified and directed.
75mm dia outlet, cast iron floor trap with CP grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4), complete all as specified and directed.
15mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,complete all as specified and directed.
15mm bore stop valves, fancy type, chromium plated, cast copper alloy with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
Rotational moulded polythylene 500 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, complete all as specified and directed.
PVC (SWR) 75mm bore, floor trap with grating including jointing with cement concrete 1:2:4 type B-1, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-103 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
All as per srl item No-103 here in above but for one 5A socket outlet on the same board controlled by one switch.
All as per srl item No-103 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead.
Switch piano flush button types 5/6 Amp, single pole, one way complete all as specified and directed.
Switch socket combination 2 in 1, outlet 5 pin, 5 Amp flush type, universal, complete all as specified and directed.
Switch socket combination 2 in 1, 5/6 pin, 5 and 15 Amp, flush type universal complete all as specified and directed.
Supply and fixing angular lamp holder, PVC/Polycarbonate type with back plate for conduit fittings with LED lamp 5 watts, complete all as specified and directed.
Supply and fix in repair Wall mounted LED Batten, extruded Aluminium heat sink provided for efficient heat dissipation & integrated electronic driver of Lamp type: 18W LED life time of 30000* hours including lamp all as specified and as directed. Make: Philips, Cat Part No: TMC 501 p 1 X T-LED 22W P3241 & ESSENTIAL LED TUBE 1200 MM 18W865 T8 AP 1 (for Tube rod) or equivalent in Havells cat part No ENDURA LINEARNE OBS 20W LED 830SPC WH OR C&S CAT PART NO TARA-E 120W LTDC122 20W LED/WD .
Supply, installation, testing and commissioning in repair of recess luminary with minimum 70 % lumen maintenance, CRI should be greater than 80, system lumen output should be minimum 3400 lumens and efficiency >95Im/w. Housing should made of CRCA with opal diffuser. Electronic Driver should be in-built with life of 50000 hrs, power factor >0.9 with THD <10%. System consumption should be 48W. Similar to Philips Cat No : FULLGLOW RC 380BG2 LED 28S-6500 PSU OD WH or Havells cat part No LHEWEB7UL1W048 or Bajaj BZRSQL36WXLWH OR CROMPTON CAT PART NO LCPL-48-TL 2X2
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required at site or directed.
Supply and fixing in replacement 10 Watt LED Bulk Head, IP 65, oval shaped pressure die-cast aluminium housing and ring, high quality polycarbonate diffuser in opal finish, complete all as specified and directed. Make : Havells Cat Part No LHEOAOP7UZ6W010 or Equivalent in C&S/Bajaj/Halonix.
Taking down old exhaust fan and fixing only exhaust fan 300mm sweep steel body, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed. Note :- Items will be issued under Sch 'B' free for fixing.
M&L in repair for MCB single pole and neutral 240 volts 6 to 32 amps 'B' Curve as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
M&L in repair for MCB single pole and neutral 240 volts 6 to 32 amps 'B' Curve as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked incl taking down old unsv complete all as required at site or directed.
Supply and laying or fixing or passing through pipe in replacement, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm twin core nominal cross section in service connections, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by -14.50% (Minus). (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Supply & fixing in replacement MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/Polycarbonate, isolated body, complete all as specified and directed.
S&F in repairs 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 120 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid separately.
Description all as per item No. 123 above but cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 123 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
Supply & fixing in replacement of cable jointing kit for 1100 Volts grade cable for outdoor termination heat shrink joint complete with jointing material and accessories suitable for 70 Sqmm to 120 Sqmm 3.5 core XLPE armoured aluminium conductor cable, complete all as specified and directed.
Sand cushioning to underground cable as per clause No 19.75 of SSR Part-I laid with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. The top layer of 15cm shall be punned to 10 cm (total 23 cm) complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable, complete all as specified and directed.
Supply and laying in repairs GI tubing light grade 80mm dia with all fitting laid in trenches or fixed on wall along pole complete for protection of electric cable/strip, complete all as specified and directed.
Supply and laying in repairs GI tubing light grade 50mm dia with all fitting laid in trenches or fixed on wall along pole complete for protection of electric cable/strip, complete all as specified and directed.
Make bore to road/cement path/hard standing for GI pipe 40 to 80 light gradefor passing armoured cable including making good the disturbed surface as per site requirement, complete all as specified and directed.
Supply, installing, connecting, testing & commissioning in replacement of LT panel board of suitable size , out door type made out of CRCA sheet 3.15 mm thick factory fabricated (including CPRI type test certified firm) and 40mmx40mmx6mm thick MS angle iron frame work, floor mounted duly powder coated, dust and vermin proof with front opening type, suitable for 415 volts, 3phase, 4 wire, 50 Hz, AC suppy system having busbar chamber with insulated aluminium busbars of rating 200 Amps and 160 Amps for neutral, installed on porcelain insulators including PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size alongwith provision of suitable power factor capacitors and comprising of the following:- INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 125 Amps with breaking capacity 25 KA - 01 No (main panel) (b) Multifunction energy meters in 96 x6 sqmm flush mounted case with six direct acess keys & backlite lCD display accuracy class 1.0, 5ACt input LV networks AC Auxiliary supply- 1 No. (c) CTs of ratio 100/50/5A, class-1, VA burden 15 - 01 set of three. (d) Indicating lamps - 01 set of three. (e) On load changeover, 4P 125 Amps - 01 No. OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 40 Amps with breaking capacity 16 KA - 03 No. (b) MCB TPN, 415 V, 32 Amps with rupturing capacity 16 KA - 01 No (c) Spare compartment - 1 No.
S & F in repair bus bar chamber of size 60x60x45cm suitable for 3 phase 433 volts, outdoor type made out of 3.15mm thick MS sheet with 200 Amps rated aluminium bus bar(4 Nos) PVC sleeves and coloured (red, yellow, blue and black) with locking arrangements and angle iron stand of size 40x40x6mm frame grouted in ground with PCC foundation 1:2:4 type B-1 with 20mm graded stone aggregate alongwith all necessary cable connections, lugs and cable gland including 2 coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6 mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 14.50% (Minus). (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Supply, installation, lowering, testing and commissioning of submersible pumping set electrical driven 415 V, TP suitable for 200 mm dia bore well (Casing pipe size 250/300mm), 20HP complete having discharge capacity 250 LPM at 250 mtr in Make : Kirloskar/ KSB/CRI including automatic star delta starter for submersible pump set in sheet metal enclosure including 3 phase power contactor, MCCB/MCB, angalog amp meter, volt meter, indicator having suitable for capacity 20 HP, 3 phase 415 volts in Make : L&T/ABB/C&S, complete all as specified and directed.
M&L flat PVC FRLS cable, sheathed with flexible multistranded copper conductor, three core of size 10 Sqmm 1100 Volts grade including copper thimbles at both side of cable, complete all as specified and directed.
S&F in repair energy saving and envoirnmental friendly long life 30 watt LED street light made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-66 protection and impact resistance of IK-07 with 10KV built-in surge protection device input 110 volts to 280 volts, provn of auto shutdown on high voltages, life >50000 Hrs, operating temperature (-) 10°C to (-)50°C, luminaries comprising of rectangular shape pressure die-cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage =10% W & rated lumens of min 5000 lumens with 120° view angle, the driver must be constant current type having THD<10% and power factor >0.95 with short circuit protection, open circuit protection, reverse circuit protection, high voltage protection, protection against 10KV high surges, complete all as specified and as directed.
S&F in repair security light bracket with 1.20mtrs long galvanised iron pipe, 40mm dia, light grade including flat iron clamps made of FI 40mmx5mm, nuts, bolts and washers including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
Supply & fix in replacement cable PVC insulated flexible copper conductor cable of size 1.5 Sqmm 3 core for street light connection, complete all as specified and directed.
Fixing only water heater vertical type, stationary storage type of 35 ltr capacity 240 volts, including fixing arrangement nut bolts, washer/fasteners and finishing work etc, complete as per existing surface, all as specified and directed. Note :- Items will be issued under Sch 'B' free for fixing.
15mm bore stop valves, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 450mm suitable for hot water and cold water for geysers, complete all as specified and directed.
Sheet metal enclosure with socket plug top single phase and neutral enclosure with a two pin and earth plug and socket with MCB 20 Amps, SP 'B' curve, complete all as specified and directed.
Point wiring with 4.0 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 4.0 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 32 to 40 Amps, 10kA and making connections complete all as specified & directed.
Fixing only, voltage stablizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 170V to 250V with output voltage stablised at 230V with accuracy ±2.5% and capacity of 3KVA, complete all as specified and directed. Note :- Items will be issued under Sch 'B' free for fixing.
MCB single pole 240 volts 16 to 32 amps 'B' Curve as per site requirement , with rupturing capacity 10 KA finger proof terminal as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification, 35 sqmm terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on existing DB, complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 6 Amps flush type 50 Hz all as specified and directed.
Javeed And Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .