Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹40.3 L+₹57,401 (1.44%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹40.3 L+₹58,041 (1.46%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹42.0 L+₹2.2 L (5.57%)Rejected-Finance | L4 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
1 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
PROVN OF 02 GUARD REST ROOM WITH ATTACHED TOILETS AND BATHROOM FOR QRT and ADP AT 16 CORPS ZONE WKSP
2022_MES_504552_1
8067/NIT-66/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Army Dhar Road Udhampur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (Army) Dhar Road Udhampur
₹77,000
Yes
7 Jun 2022
29 Jan 2022
4 Mar 2022
29 Jan 2022
1 Mar 2022
12 Feb 2022
31 Jan 2022 - 10 Feb 2022
60 days
Amount
Surface dressing n exc 15 cm deep in soft/loose soil
Excavation in trenches, not exceeding 1.50m wide and not exceeding 1.5m in depth etc not exceeding 10 Sqm on plan for shafts, cesspits, manholes, pier holes, foundation etc and getting out in any type of soil soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in cement concrete in foundations, filling and mass concrete complete all as specified and directed.
M&L Reinforced cement concrete M-25 using 20mm graded aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
All as per item No 4 above but in columns
All as per item No 4 above but in beams, cantilevers, bressummers, lintels over 1.5m span
All as per item No 4 above but in Chajjas
M&L Reinforced cement concrete M-25 using 20mm graded aggregatesas in slab supported on walls, beam and columns in floors, roofs , landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L Form work to sides of rough finished flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L Form work to sides of rough finished square, rectaungular or polygonal surfaces of of pillars, posts, struts, piers, columns and stanchions.
M&L Formwork to sides and soffit of rough finished flat surfaces of soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L Form work to rough finished flat surfaces of chullah hoods, chajjas, troughs and similar items in- cluding edges
M&L Form work to rough finished flat surfaces of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No 14 above but 6mm to 8mm dia
All as per item No 15 above but 5mm dia and over upto and including 10mm dia in stirrups etc
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius in CM 1:6 complete all as specified and directed.
M&L Brick work with subclass 'B' bricks, straight or curved on plan to any radious in half brick thick walls in CM 1:4 complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement with WPC 3% weight of cement complete all as specified and directed. (WPC shall be measured and paid separately)
Supply only integral water proofing compound,
M&L Rendering 15mm thick cement plaster in CM 1:6 on other than fair faces of brick work or concrete sur- faces finished even and smooth without using extra cement.
All as per item No 21 above but 10mm thick in CM 1:3 in Ceilings finished even and smooth without using extra cement.
M&L Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified.
M&L Preparation of new plastered surfaces of wall and applying two oil bound distemper over a coat of alkali resistant primer complete all as specified.
M&L Preparation of new plastered surfaces of wall and applying three coats of white wash on wall ceilings complete all as specified.
S&F Pressed steel frames size 125 mm x 60 mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, complete all as specified.
M&L PCC M-10 type C0, 1:3:6 using 12.5mm graded stone aggregates for filling in steel frames
S&F Steel window made up of box steel section of 16 gauge MS Sheet in outer frame, shutter frame and centre frame, with fixed type partly gl;azed and partly gauzed with outer side glazed shutter and inner side wire mesh shutter fixed with suitable steel handle dovetailed or welded with each shutters pannels complete with necessary clit and stopper all as specified as directed.
S&F Steel ventilator made up of box steel section of 16 gauge MS Sheet fixed type partly galzed and partly gauged inner frame and centre frame, including outer side glazed shutter and inner side wire mesh shutter fixed with MS clip consisting with dovetailed or welded with each pannels complete with necessary clit and stopper all as specified as directed.(MS Gaurd bar/griil work will be measured and separetly)
S&F 35mm thick second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S&F 35mm thick second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. with two Nos Muntines edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
S&F Al 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F Galvanised mild steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.00mm
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane
.ditto above but pin headed.
S&F 200mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed
S&F 150mm long anodised aluminium alloy handles, fabricated type
S&F MS 300mm long ordinary rat tail rod pattern spring incl roller and plate complete all as specified
S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F for expanded metal exc 4 Kg cut to length bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia all fixing with galvanised steel stapple fixed to steel or wood members laid in any position incl closing after filling.
M&L for two coats of synthetic enamel paint on steel surfaces, over a coat of red oxide primer incl preparation of new steel surfaces 10cm in width or grith not ohter wise described complete all as specified and directed.
M&L for two coats of synthetic enamel paint on wooden surfaces, over a coat of pink primer incl preparation of new wooden surfaces 10cm in width or grith not ohter wise described complete all as specified and directed.
M&L 50mm thick Cement conrete type C2, 1:3:6 using 40mm graded stone aggregates for plinth protection laid in alternate panels and finish even and smooth without using extra cement all as specified and directed.
S&F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe)
S&F PVC valveless, syphonic action type, flushing cistern (10 Ltrs), low level, white, with inlet, ball valve, float and handle including brackets
Supply only flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F Wash basins, Vitreous China (flat back or angle back type) size 550x400mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply pipe but including brackets and 32mm dia PVC Waste pipe 800mm long complete all as specified.
S&F CP Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms)
S&F Soap dish, vitreous China white, approximate size 160x 160x90mm
S&F Vitreous China urinals, bowl type (back or corner wall type) size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe
upply only Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement
S&F 75mm dia PVC (SWR) bends
All as per item No 56 above but 110mm dia
All as per item No 56, 57 and 58 but with access door
S&F 110mm dia PVC (SWR) junction single (Single T) equal or unequal with access door
S&F 75mm dia PVC (SWR) type B Pipes single socketed in any length with rubber ring joints laid in trenches or in floors
All as per item No 61 above but 110 mm dia
S&F 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F 15mm bore dia Pillar tap fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F 15mm bore dia Bib taps long body fancy type cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule fixed complete all as specified and directed.
S&F 15mm bore dia CP stop valve/angle valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete.
S&F PVC connections 15mm size with PTMT nuts of length 450mm
S&F fancy type brass chromium plated shower rose 125mm size with CP swiveled type arm fixed to steel pipe or union complete.
M&L 15mm bore steel tubes "medium grade" galvanised with all fitting and fixed complete in walls ceilig or laid in floors.
All as per item No 69 above but 20mm dia
All as per item No 70 above but 20mm dia laid in trenches.
S&F 32mm dia Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms)
M&L filling under floors or in foundations with approved soil including spreading, levellig in layers n exc 25cm thick and well ramming, watering as reqd complete all as specified and directed.
M&L 75mm thick Cement conrete type D2, 1:4:8 using 40mm graded stone aggregates as in sub-base, sub-floors, floors etc complete all as specified and directed..
M&L Machine cut kota stone slab flooring 16-18mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 20mm thick screed bed in 1:4
All as per item No 75 above but in skirting includig 10mm thick backing coat in CM 1:3
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm (size 300x300), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6
M&L for Glazed ceramic coloured tiles 300x450x 7mm thick on vertical surfaces of wall set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting in vertical surface complete all as specified and as specified.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) land on primed surface by torch application with end lap 100mm and mid 75mm complete all as specified and directed.
M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces
M&L for providing and laying 40mm thick PCC (1:2:4) using 20mm graded agg with WPC Compound complete all as specified and directed by Engineer-in-Charge.(WPC will be paid seperately)
M&L Termite Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M&L Termite Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L Termite Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
S&F 1000 Ltr capacity Rotational moulded polye- thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F 20mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F Gun metal globe or gate valves high pressure with screwed for iron pipe or for unions of 15 mm bore and fixed, all as specified and directed
Returning filling in and including spreading levelling watering and well ramming in layers n exc 25cm thick.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
S&F 20mm dia MS PVC coated curtian rod with side knobs and holding brackets fancy type complete all as specified and directed
Supply & fixed Stain less steel peg set of six as approved by Engineer-in-Charge.
Providing Kitchen cabinet shutter/Partation/Shelves in required size at site made out of 18mm thick MDF board one side decorative lamination PVC sheet complete all required etc. The panels shall be fabricated using adhesive and secure as required. All edges shall be covered with 2mm thick edge bonding taps or 90⁰ edge bent finish as per manufacturers instructions.
Surface excavation n. exc 30 cm deep and averaging 15cm and getting out hard/dense soil complete all as specified and directed.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone agg) as in levelling course for laying floor finishes.
Machine pressed precast concrete interlocking paver block, shape and size as approved by the GE, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning, complete all as specified and as directed.
M&L for pre cast cement concrete block masonry 1:3:6, type B-1, using 20mm graded stone agg with solid blocks of size 8cm thick 25cm wide and 30cm depth/ ht and setting with cement and pigments, complete as in kerbs or mud stops, rounded or chamfered on edges complete all as specified.
M&L for pre cast cement concrete block masonry 1:3:6, type B-1, using 20mm graded stone agg with solid blocks of size 8cm thick 25cm wide and 30cm depth/ ht and setting with cement and pigments, complete as in kerbs or mud stops, rounded or chamfered on edges complete all as specified.
Reinforced concrete pipes, class NP2, laid & jointed complete with collars, bore of pipe 150 mm, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret M-10 (Nominal mix) type C-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Cutting into existing man holes for connecting new drains making good to pipes and rendering cutting out existing benching for and forming branch channel (1/2 round or ¾ in section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) surface smooth finished and reforming benching as required for internal dia of pipe 150mm all as specified and directed .
M&L for precast cement concrete 1:2:4 type B1 using (20mm graded stone aggregate) as in slab for manhole cover complete all as specified and directed.
M&L for PCC 1:2:4, Type B-1 using 20mm graded stone aggregate as in coping,benching, even and smooth without using extra cement etc complete all as specified.
Extra for forming girth n exc than 30cm deep and all as specifed and directed
Construction of septic tank with cover slab RCC M-25 (design Mix) for 25 user with brick walling in CM 1:4 (with top of slab at ground level) including necessary excavation and earth work in any type of soil and disposal or surplus soil as directed , RCC man hole covers with angle iron frame CI vent shaft with CI cowl complete all as shown on drawing and as specified and as directed by Engr-in-Charge.
Sokage wells including excavation in ordinary soil foundation in PCC 1:3:6 walls of honey combined and soild in CM including intercepting scren well chamber brick work in CM RCC cover slab in M-25 filling with brick bats of size 1.8 mtr dia nad 3,00 Mt deep complete all as specified and as directed.
M&L Plain Cement concrete type C2, 1:3:6 using 40mm graded aggregates in foundations, filling and mass concrete
M&L PCC 1:2:4, type B1 using 20mm graded aggregates in surface channels and drains surface finished even and smooth using extra cement.
M&L 15mm thick cement plaster in 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 16 Sqmm 2 core with required aluminium cable lugs all as specified and directed. Make of Cable : Havells, Polycab, Gloster,Finolex
Supply and laying in trenches/ floor or fixed to pole/ wall GI pipe light grade with fitting of size 40mm bore for protection of cable including dismanteling existing pipe complete all as specified and directed.
M&L for cutting for PCC/ hardstanding /WBM Road not exceeding 20cm in width and not ecx 30 cm in depth for passing of LT cable and making good of disturb surface to match with the old and material i.e. bitumen/PCC (1:3:6) type C-1 complete all as specified and directed.
M&L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M&L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
M&L 20mm bore steel tubes "medium grade" galvanised with all fitting including connection with existing pipe line , laid in floors/trenches complete all as specifeid anddirected.
M&L 25mm bore steel tubes "medium grade" galvanised with all fitting including connection with existing pipe line , laid in floors/trenches complete all as specifeid anddirected.
S&F Gun metal globe or gate valves high pressure with screwed for iron pipe or for unions of 20mm bore and fixed in repairs, all as specified and directed
Cutting/making hole into CI/DI/MS pipes of 100 mm carefully and insertion of new tee incl clamping with suitable size clamp for taking small branch connection upto 25 mm bore complete all as directed by EIC.
Material and labour for Point wiring complete (for simple and modular type ) with 1.5 sqmm single core PVC insulated ISI Marked,FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC white non metalic PVC conduit not less than 20mm dia with all accessories like tee, straight joint, L Bend etc.,concealed on walls, sufrace on ceiling/ floors etc., and including provision of PVC heavy duty Insulated FRLS copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal modular sunken box fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., for the following:-
One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch.
One switch socket outlet point 3 pin 5 Amps on Independent board.
One switch socket outlet point 3 pin 5 Amps on same board.
Material and labour for Point wiring complete with 2 run of 2.5 sqmm single core PVC insulated ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including suitable size of PVC white non metalic conduit with all accessories like tee, straight joint, L Bend etc., concealed on wall surface on ceiling / roofs etc., and including provision of PVC insulated ISI Marked unsheathed copper conductor 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box fixed and flushed inside the walls, with laminated sheet top cover for housing the switches/socket outlets 15 Amps.
S&F bracket holder/ Angle lamp holder fixed on wall /ceiling all as approved and directed by Engineer-in-charge.
Supply only LED 9 Watt lamp , 240 Volt, 50 Hz lamp
S/F Bell Push flush type.
S/F Call Bell AC 230 V Single Pole along with necessary electric connection all as spd and directed.
Supply and Fixing LED 20 Watt light fitting Baton integrated LED channel, integral sleek extruded polycarbonate LED Channel with white acrylic cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete with all accessories all as specified and directed by Engr-in-Charge.
Supply and fixing Exhaust fan AC single phase 230 volts for size 300 mm sweep, including making hole and fixing arrangement including nut, bolts, washer etc, making good the disturbed surfaces matched with existing finishes comprising with necessary eletric connection with suitable copper wire from ceiling rose complete all as specified and directed.
Supply and fixing Ceiling fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement such as nut, bolts, washer etc, making good the disturbed surfaces matched with existing finishes comprising with necessary eletric connection with suitable copper wire from ceiling rose complete all as specified and directed.
Supply and fixing of building security LED fitting upto 40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Security light Complite all as directed by EIC
S&F 1.5m long 40mm bore light grade GI pipe bracket duly cut to size and bent to shape required duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, including suitable 2 Nos. FI clamps as required to fix on concrete / steel poles complete all as specified and as directed
Supply & fix Electric Storage water heater of capacity 25 Ltr , 230 V energy efficient complete all as specified and directed by Engineer-in-charge.
S & F ceiling rose Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and directed.
Supply and fix fan speed regulator, electronic step type, suitable for single phase AC, 240 volts, 50 Hz, all as specified and as directed.
Supply and fixing socket outlet 5 Amp 230 volt ISI Mark complete all as specified and directed
Supply and fixing Switch , single pole, one way 5 Amp 230 Volt ISI Mark complete all as specified and directed
Supply and fixing socket outlet 16 Amp 230 volt ISI Mark complete all as specified and directed
Supply and fixing switch , single pole, one way 16 Amp 230 volt ISI Mark complete all as specified and directed
Supply & Fixing SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
S.K CONSTRUCTION
DAVINDER SINGH
JINDAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .