GE (MES) ROORKEE
Garrison Engineer Roorkee
REPAIR/ MAINTENANCE DG SET, T and P , MINOR REPAIRS AT MES INSTALLATION, REPAIR TO RCC OHT, SEWAGE PUMPING INSTALLATIONS AND CONNECTED ITEMS AT ROORKEE, SAHARANPUR AND PURKAZI UNDER GE ROORKEE
2023_MES_611233_1
8392/289/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SAHARANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (MES) ROORKEE
₹70,000
Yes
13 Jan 2024
29 Jul 2023
5 Sept 2023
29 Jul 2023
2 Sept 2023
12 Aug 2023
Amount
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 250 KVA complete all as specified and directed. Make - Cummins Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only Oil bypass filter element with 'O' ring
(g) Supply only fuel water seprater
(h) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 125 KVA to 100 KVA complete all as specified and directed. Make - Cummins/Kirlosker Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates.
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only Oil bypass filter element with 'O' ring
(g) Supply only fuel water seprater
(h) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 125 KVA complete all as specified and directed. Make -Greaves Cotton Ltd. Note : (a) Spare parts shall be measured and paid separately under (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only fuel water seprater
(g) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 62.5 KVA to 63 KVA complete all as specified and directed. Make Kirlosker/Ruston Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only fuel water seprater
(g) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 40 KVA to 45 KVA complete all as specified and directed. Make Ruston Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only fuel water seprater
(g) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 5 to 20 KVA complete all as specified and directed. Make, Kirlosker/Ruston Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only Engine oil of grade 20W40
(f) Supply only fuel water seprater
Dismenttling of air filter oil bath type from DG Set ,Cleaning & Repairs replacing the engine oil & minor parts complete & refixing the same all as directed.
Disconnecting, removing and dismantling water radiator assembly from DG Set of 5 KVA to 20 KVA DG set and descaling the radiator thoroughly with radiator cleaner solution/ any other chemical solvent agent as approved by Engr-In-Charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enameled paint etc., re-installing and commissioning complete all as specified and as directed.
All as per item No 52 above but for DG set of capacity 40 KVA to 63 KVA complete all as specified and directed.
All as per item No 52 above but for DG set of capacity 100 KVA to 125 KVA complete all as specified and as directed.
Repairs of charging alternator of 12 Volt, by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly and re-fixing to the engine and testing for satisfactory charging of battery including all necessary repair complete all as specified and as directed.
All as per item No 55 above but of 24V, required for battery charching alternator complete all as specified and as directed.
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) with new ones of the exising make of generator of capacity 125 KVA to 250 KVA, complete all as specified and directed.
All as per item No 57 above but of 63 KVA to 100 KVA complete all as specified and directed.
All as per item No 57 above but of 40 KVA to 45 KVA complete all as specified and directed.
All as per item No 57 above but of 5 KVA to 20 KVA complete all as specified and directed.
M&L for repair & overhauling the self starter assy 12 Volts by taking out from the DG set capacity 125KVA Disnmantling & cleaning , providing proper insulation rewininding armature and stator assembly with super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs , testing on completion complete all as specified and directed.
M&L for repair & overhauling the self starter assy 24 Volts by taking out from the DG set capacity 63 /125 KVA Disnmantling & cleaning , providing proper insulation rewininding armature and stator assemblywith super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs , testing on completion complete all as specified and directed.
M&L for repair & overhauling of the self starter assy 24 Volts by taking out from the DG set capacity 250 kvaDisnmantling & cleaning , providing proper insulation rewininding armature and stator assembly with super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs, testing on completion complete all as specified and directed.
M&L for repair & overhauling of the self starter assy 12 volts by taking out from the DG set of capacity 63KVA/100 KVA, Disnmantling & cleaning , providing proper insulation rewininding with super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs, testing on completion complete all as specified and directed.
M&L for repair & overhauling of the self starter assy 12 volts by taking out from the DG set any capacity below 45 KVA, Disnmantling & cleaning , providing proper insulation rewininding armature and stator assembly with super enamelled copper wire of existing size & insulating the field coil assy & replacing pinion and clutch assy & fixing back after repairs , testing on completion complete all as specified and directed.
M&L for replacement of battery terminal positive & negative made of brass with necessary brazing to cable complete all as specified and directed.
M&L for replacement of battery cable of 70 Sqmm PVC insulated multi stranded copper conductor single core cable with necessary copper lugs complete all as specified and directed.
Supply only inhabitor non corrossive coolent in 2lit/01 lit pack for Top-up, mixed with distilled water as recommended ratio complete all as specified and directed. Make : Castrol, Fleet Guard
Supply only distilled water in 5 lit packed for top up distillled water for mixing of coolent as per recommended ratio complete all as specified and directed.
Taking down dynamo 12 volt from any capacity of DG SET, from the exisintg position, dismantling the same and repairing by turning of commutator replacing the armature, carbon brush varnishing the coil reassembling the parts and refixing in position testing and commissioning complete all as specified and directed.
M&L for preparing old metal surface by cleaning, removing old paint by paint remover/scrappers for any width or girth and applying two coats of synthetic enamel paint by spray painting (second coat shall be applied at the interval of one day) of colour complete all as specified and directed for DG Sets as followings capacity :-
(a) 250 KVA DG set
(b) 100 KVA TO 125.5 KVA DG Set
(c) 40 KVA TO 63 KVA DG Set
(d) 15 KVA to 20 KVA DG Set
Taking down PT pump from engine, over hauling & calibiration at workshop, and clean with cleaning agent including replacement of defective parts by new parts reinstallation, and testing complete. for 63/100 KVA complete all as specified and directed. Note- Defective parts measured and paid separetely in respective items here in after
(a) Supply only gaskit set
(b) Supply only techo shaft assembly
(c) Supply only throttle shaft
(d) Supply only gear pump
(e) Supply only berral & sleeves
(f) Supply only governer plunger
(g) Supply only shut down valve assymbly
Taking down injector asseymbly from D G Set & neatly cleaned by cleaning agent, repair & calibiration at workshop,including replacement of defective parts by new parts ,reinstallation, and testing complete for 63 KVA to 125 KVA complete all as specified and directed. Note- Defective parts measured and paid separetely in resprctive items here in after
(a) Supply only injector cup set
(b) Supply only barrel plunger
(c) Supply only 'O' ring set
Taking down injector asseymbly from D G Set & neatly cleaned by cleaning agent, repair & calibiration at workshop,including replacement of defective parts by new parts ,reinstallation, and testing complete for 5 KVA to 20 KVA complete all as specified and directed. Note- Defective parts measured and paid separetely in resprctive items here in after
(a) Supply only injector cup set
(b) Supply only barrel plunger
(c) Supply only 'O' ring set
Taking down turbo charger assembly from 100 KVA DG set Repair / over hauling including replacement of defective parts by new parts ,reinstallation, and testing for 250 KVA DG Set complete all as specified and directed. Note- Defective parts measured and paid separetely in resprctive items here in after
(a) Supply only Terbo repair kit
(b) Supply only Terbine wheel & shaft
(c) Supply only compressor wheel
All as per item No. 93 above but 100 KVA DG set complete all as directed.
(a) Supply only Terbo repair kit
(b) Supply only Terbine wheel & shaft
(c) Supply only compressor wheel
All as per item No. 93 above but 63 KVA DG set complete all as directed.
(a) Supply only Terbo repair kit
(b) Supply only Terbine wheel & shaft
(c) Supply only compressor wheel
Supply & Fixing Asbestos rope suitable for silencer of DG Set as directed
Taking down of AC alternator from DG sets of capacity 5 KVA to 20 KVA after disconnecting all electrical connections, and rewinding the burntout winding clining throuly and rewinding with supper enamaled wire of existing size/gauge complete with proper insulation, and re-installation and reconnecting alternator with engine including testing on load complete all as specified and as directed : - (i) Rates are including transportation of alternator to workshop and bringing back to site for re-installation and reconnecting alternator with engine.
All as per item No. 106 above but 40 to 63 KVA DG set complete all as specified and directed.
All as per item No. 106 above but 100 to 125 KVA DG set complete all as specified and directed.
Taking down of FIP from engine,repair overhaulling,calibration and testing of fuel pump of 20 KVA to 40 KVA capacity DG set including replacement of defective parts , and adjustment of injectors and setting of fuel pressure complete all as specified and as directed.
(a) Supply only delivery valve
(b) Supply only roller
(c) Supply only rocker asssambly
(d) Supply only element
(e) Supply only FIP gasket set
All as per item No. 109 above but, 62.5 KVA to 63 KVA DG set complete all as specified and directed.
(a) Supply only delivery valve
(b) Supply only roller
(b) Supply only roller
(c) Supply only rocker asssambly
(d) Supply only element
(e) Supply only FIP gasket set
All as per item No. 109 above but 100KVA to 125 KVA DG set complete all as specified and directed.
(a) Supply only delivery valve
(b) Supply only roller
(c) Supply only rocker asssambly
(d) Supply only element
(e) Supply only FIP gasket set
Supply & fixing in replacement shut down valve assymbly complete all as specified and directed.
Supply & fixing vaccume indicator complete all as specified and directed.
Supply & fixing rubber hose cooler any size complete all as specified and directed.
Supply & fixing Hose rubber for radiator any size complete all as specified and directed.
Supply & fixing fuel pipe from tank to filter with all fittings complete all as specified and directed.
Supply & fixing fuel pipe from filter to pump assymbly with all fittings complete all as specified and directed.
Supply & fixing water pump assymbly suitable for 62.5 KVA DG Set complete all as specified and directed.
Supply and fix in replacement 'Off Load' change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps with side/front load handle operated complete all as specified and as directed.
Supply and fix in replacement 'Off Load' change over switch 415V in sheet metal enclosures 4 pole of capacity 160 Amps with side /front load handle operated complete all as specified and as directed.
Supply and fix in replacement 'Off Load' change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps with side /front load handle operated complete all as specified and as directed.
Supply and fix in replacement 'Off Load' change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps with side /front load handle operated complete all as specified and as directed.
Supplying and laying in replacement synthetic Rubber insulated mats 2.0 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and directed.
M&L for disconnecting & dismantling of three phase, 415 volts, 50 Hz, 1460-1500 RPM alternator assembly of any make and model from DG set from installation, transporting the same to workshop, removing all burnt / worn out coils, cleaning of stator slots, insertion of insulating paper in the slots of appropriate size and rewinding with supper enameled copper wire ISI marked with existing size, applying two coats of insulating varnish including transporting back the same and re-installation of motor at site complete all as specified and directed for the following capacities: -
(a) Capacity 250 KVA
(b) Capacity 63/125 KVA
(c) Capacity 5/15/20 KVA
S&F in repair of earth continuity conductor or main earthing lead fixed to wall or any other indicated situation for loop earthing etc. as required GI strip 32x6 mm complete all as specified and directed.
Disconnecting carefully old unserviceable ammeter from panel board and S&F of new 96mm size square/circular digital type ammeter of range 0-30 ampere or 0-300 Ampere, size of letters 25mm, with set of CTs of suitable rating, necessary connectiong/fixing arrangements and testing complete all as specified and directed. make AE or Equivalent
Disconnecting carefully old unserviceable Voltmeter from panel board an S&F of new 96 mm size square/circular digital type Voltmeter of range 0-500 Volt,size of letters 25mm, make -AE (ISI marked), necessary connecting/fixing arrangements and testing complete all as specified and directed
S&F as in replacement of LED type indicating lamps of RYB colours as directed at site on existing panel board including necessary fixing and connecting arrangements complete all as specified and directed
M &L for reconditioning of unserviceable battery 12 volt, 120 to 180 Ah by replacing complete cells, PVC saperaters, electrolyte, terminals & final sealing, recharging and testing complete all as specified and directed.
Supply and fixing in replacement of U/S batery with new 12 volts150 AH lead acid tubular battery complete all as specified and directed. Make- Exide, Amron/ Livefast
Supply and fixing in replacement of U/S batery with new 12 volts 92 AH lead acid tubular battery complete all as specified and directed. Make- Exide, Amron/ Livefast
S & F in replacement of old unserviceable LED Post Top Lantern light fitting 40 watt capacity with transperent diffuser and fixing arrangement on including GI Pipe light grade of dia 40 mm duely grouted on wall/brick pillar complete all as specified and directed at siteand electrical connection from junction box to light fitting complete all as specified and directed. Make: C&S Cat .LTGLM40WHPLED/W or any equivalent model in Havells/Philips/Wipro.
M & L for refilling of fire extinguishers of capacity 9 Kg foam / ABC type complete all as specified and directed.
M & L for refilling of fire extinguishers of capacity 5 Kg foam / ABC type complete all as specified and directed.
M & L for refilling of fire extinguishers of capacity 2 Kg foam / ABC type complete all as specified and directed.
S&F antivibration pad suitable for 250 KVA DG Set,125 KVA DG Set and 63 KVA DG Sets for mounting DG Sets including removing broken hinges and making good surface for fixing in new hinges compatible for closing and opening and greasing thereafter, complete all as specified and directed
S&F in replacement of glow sign board box type of size 120 cm x 300cm of acrylic sheet cover in sky blue colour one side display and GI Sheet for back side and made of MS angle frame not less than 40x40x6mm with 02 x LED tube light fittings complete including connecting up with twin core twisted flexible copper conductor cable with suitable size and necessary items for fixing on roof of Pump House & Power House and stnecil of word as reqd with all grouting and PCC work complete all as specified and as directed
Inreplacement,Supply, fabrication, installation, testing and commissioning, cubical type LT indoor panel, dust vermin proof ,front operated type CPRI approved , made out of f 2.00 mm thick CRCA sheet , of suitable size complete wiring copper bus bar chamber cable alley, cable glandes brass cromine plated of different sizes suitable for incomming and out going MCCB's panel with powder coated paint and all as specified for following items:- (for pump house - Submersiable pump 20/25 HP)
(a) Copper busbar of capacity 400 Amps with epoxy insulated supports 3 phase and neutral -01 set Incommer (b) Off Load type Change Over front operatted panel mounted switch ,200 A, 4 pole ,415V AC -01 No (c) MCCB 125 A, 4 pole 36 KA MCCB with adjustable thermal and magnatic setting including extendable link -01 No Out going feeders: (d) Out going MCCB 100 Amps 36 KA 4 pole-0 2Nos (e) MCB SPN 32 Amps 02 Nos (f) Multifunction meter model MIM 10 type 96 sqmm,sutable for measuring of VAF -01 set (g) Indication lamp set LED type -02set (h)ML FASD Starter, 3 phase 415 V,50Hz,complete with all assassories & inluding contactor MNX-40 -03 Nos,OCR protection relay suitable for 20/25 HP Pump/Motor - 01 Nos (j) Single Phase preventer. (k) Under voltage preventer (l) Phase reversible relay (m) PCC plateform length & width as per requirement 450mm high, 300mm above ground level and 150mm below ground level, plastered, painted with two coats of cement base paint white and centre portion filled with dry fine sand, four Nos bolts grouted for fixing panel -01 job. Note:- All relay makes are Minilec cat pat No-VSP 2 or equevalent in L&T/S chieder/Legrad.
Supply and laying along the pole/pipe or passing through pipe or laid underground/floor through walls etc, jointing and testing XLPE insulated galvanised steel wire armoured electric cable 1100V grade heavy duty ISI marked with Aluminium conductor of cross sectional area 240 sqmm 3.5 core complete all as specified and as directed.
All as per item No. 159 above but of size 120 sqmm 3.5 core
All as per item No. 159 above but of size 95 sqmm 3.5 core
All as per item No. 159 above but of size 6 sqmm 2 core
M&L of GI pipe light grade 100 mm dia for cable protection including cold drilling and making good surface as per existing complete all as specified and directed.
M&L of GI pipe light grade 40 mm dia for cable protection including cold drilling and making good surface as per existing complete all as specified and directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M depth in any type of soil and getting out for laying GI strip conductor, stay, poles etc complete all as specified and directed.
Returning, filling in including spreading laveling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing excavated material n.exc. 50M and depositing where directed at a level n.exc. 1.5M above the starting points complete all as specified and directed.
Supply and spread unwashed dry river sand for sand cushioning and covering the UG Cable in trenches complete all as specified and directed. (Note : Punning thickness (18cm) shall be measured)
Supply & lay in trenches sub class `B’ bricks having compressive strength 75 Kg/ Sqcm for cable protection etc compete all as specified and directed by Engineer-in-Charge.
M&L for repair to rolling shutter door of any size in any position with replacement of unserviceable parts such as spring,horizontal straightning rod of MS pipe 40mm dia to make the rolling shutter functional not exceed 8sqmtr including oiling,greasing and painting with two coat of super enamelled paint complete all as specified and directed.
S&F in repair of safety lever locks mild steel with 4 levers for rolling shutter complete all as specified and directed
M&L pre painted galvanised corrugated steel sheets zinc coated @ 350 gms per Sqm including complete necessary arrangement for fixing of sheet, completed all as specified and directed
M&L steel work in tubular trusses including special shaped washer etc, complete using MS ERW or induction butt welded tubes confirming to IS 1161-1979 grade st-240
Demolition of unrenforced cement concrete in ground floors and pavings n.exc 15 cm thickness below or above ground level.
M&L 75mm PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection and hard standing.
M & L for precast machine pressed cement concrete interlocking paver blocks of any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade, glossy type with grey cement and pigment as approved by GE , laid dry over a layer of 25 mm thick sand cushioning complete all as specified and directed.( sand cushioning will be measure and paid under relevent items)
Supply only fine aggregate (sand) complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20m graded stone aggregates as in kerbs, rounded or chamefered on edges.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for 15 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes.
S&F inreplacement of rediator aasy complete copper finsand tubes complete, capacity 62.5 to 125 kva as per existing makes/size all as specified and directed.
Demolition of concrete of any description in any position all as directed by Engineer -in-charge.
M&L for 75 mm thick PCC 1:3:6 as in plinth protection surface finish even and smooth without using extra cement complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking down cement plaster on brick or stone walling buyilting CM including raking out joints hacking for key scrubbing down with water etc complete as specified
M&L Rendering 15 mm thick in CM (1:6) using coarse sand on brick or concrete surface finish fair & even smooth without using extra cement complete all as specified and directed. (The work shall be executed by using necessary scaffolding)
M&L Rendering 15 mm thick in CM (1:4) using coarse sand on brick or concrete surface finish fair & even smooth without using extra cement complete all as specified and directed.(The work shall be executed by using necessary scaffolding)
M & L for new plastered surface on walls and applying two coats cement based paint over one coat of alkali resistant priming paint complete.( Make : Snowsem/Durocem/Crimocem)
M&L for demolition of brick work built in Cement Mortar including M&L for brick work with sub class ‘B’ bricks straight on curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for PCC (1:2:4) Ty B-0 using 12.5mm thick course aggregate as in cills, steps, parapets,, copings, as in filling of steel chowkats or frames, cills and hold fast etc.complete all as specified and as directed.
Taking down old U/S wooden /steel chowkhat with shutter nexc 1.50 sqm each and removing from site.
All as per item No. 193 above but exc 1.5 and nexc 4 sqm
S&F solid PVC door frame of the size 50mm width , 47 mm height with a wall thickness of 5mm(+0.25) made out of extruded 5 mm made out of 5mm PVC sheet reinforced with MS square tube as per specification drying as per manufacture instructions including all necessary fitting complete.
S&F 30mm thick factory made solid panel PVC door shutters made out of MS tubes of top and bottom rail MS frame shall be covered with heat moulded PVC "C" channel 5mm thick and having width of 50mm for from stiles and H section of 100mm wide for the rails, the inner panel 6mm thick PVC sheet insulated between frame and panel should be struck to the stiles and rails 50x30x5 mm, channel rails 100x30x5 mm H junction. The size, design and pattern of the paneled shutter shall be proceed by GE / Eng-in-Charge and all as per drawing / manufacture instructions complete all as specified including locking device and all necessary fitting etc here and after complete
M&L second class hard wood (SAL) plain solid, straight chowkats, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F factory made 35 mm thick Plain framed, panelled shutter (two or more panel) single or double leaf with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated factory made complete all as spcified and directed
S&F 100 mm size medium grade MS butt hinges complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified and directed.
Fixed in repairs Mild Steel sliding door bolts, 300 mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete.
S&F 150mm long aluminium handle, cast type, anodised complete all as specified and directed.
M & L for preparation of newly surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F Mild steel door frame by using M.S angle/flat iron including M.S butt hinges 100mm size, formial provision of double rebate to recive door shutter including necessary hold fast and pcc block in cement concrete 1:2:4 type B1 complete all as specified.(PCC block/Butt hinges shall be mesured and paid seperate).
M&L Preparing New steel surface of any description over 10 cm width girth not otherwise describe and applying two coat of synthethic enamel paint over a coat of red oxide complete all as specified and directed.
M&L 75mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base etc.
M&L for 60 mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of M-35 Grade made with grey cement and pigment complete all as specified and directed (Make:-ECO/KRISHNA) .
Supply and laying sand (25 mm thickness ) for cushioning to interlocking paver block complete all as specified and directed.
M&L for providing cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in sides of PCC tiles, bed blocks, for hold fast, coping and similar work complete all as specified and directed.
Taking out unserviceable centryfugal pump set including supply and fix new self priming centryfugal pump set SP4L complete with induction motor 9.3 KW/12.5 HP, 1450 RPM Three Phase foot mounted IE2 motor mounted on a base frame total head 19 mtr, discharge capacity 28 L/S including all fixing arrangement like cutting and welding of pipe, fixing of tee/ bend/base all rates are included all as specified and directed Make : Kirloskar model no HEF43/XV-41or equevalent make as approved by GE. Note : Taking out motor & pump keeping safe custody and deposit in MES store.
S&F DOL starter suitable for 1HP to 5/10 HP Three phase 415 volt current rating 6-10 amps all as specified and directed. Make Crompton cat pat No CGST0516D or equevalent in L&T/Schneider/Havels
M/S ROORKEE ENGINEERING
M/s badrinath Traders
Bidder Name
TRINITY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .