| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L1₹32.3 LRejected-AOC | L1 | Rejected-AOC REJECTED | |
| 3 | L3₹33.6 LRejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹37.1 LRejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹38.6 LRejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L5 | Rejected-AOC REJECTED |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
19 Feb 2024, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
SPECIAL REPAIR TO REPLACEMENT OF OLD UNSERVICABLE SOLAR LIGHTS TO INTEGRATED SOLAR LIGHTS AND LT CABLES AT MO (MB) GHATKOPAR AND SPL REPAIR/ REPLACEMENT OF PUMP AGAINST BER AT 23A MHADA PUMP HOUSE AND HANGER INTERNAL WIRING AT NAE SANTACRUZ UNDERGE(N
2024_MES_636218_1
8317/B
Open Tender
Civil Works
Item Rate
180 days
GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹68,000
Yes
24 Jun 2024
6 Jan 2024
20 Feb 2024
6 Jan 2024
19 Feb 2024
12 Feb 2024
6 Jan 2024 - 16 Jan 2024
Amount
Supply, install, testing and commissioning of Monoblock pump suitable for 415 V, 3 phase system having minimum capacity 10 HP.and pumping water upto a head 60 Mtr with min discharge 6 LPS with all necessary accessories and fittings including PVC insulated & PVC Sheathed 3 core 06 Sqmm copper cable from motor to starter with protection pipe and necessary suitable size foundation in PCC 1:2:4 Type B-1 using 20mm graded stone aggregate suction and delivery suitable bore pipe and mounting arrangement and including taking down carefully old unserviceable Pumps and deposited to MES store yard. all as directed by Eng-in-charge comprising of the following:-(a) priming funnel with valve (b) pressure gauge at delivery side of pump set (c) Common base frame for pump set complete all as specified and directed.
Supply and fix in repair Hand Wheel Operated ISI Marked Gun Metal Body Gate Valve of Size: 50mm (2 inch) complete all as specified and directed.
Supply and lay pipe galvanized, “Medium class”,50 mm (2.0”) dia.including fittings all as specified and directed.
Supply and lay pipe galvanized, “Medium class”,80 mm dia.including fittings all as specified and directed.
Supply and Fixing Gun metal non return valve ( NRV) of size 50 mm of class 1.6 PN confirm to IS 5312 with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size complete all as specified and directed.
Supply and fix Cast Iron heavy duty Foot valve with leather flap screw type/flange type conforming to IS:4038, ISI Marked of size 80 mm complete all as specied and directed.
Supply,install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), as per IS-8623, panel board made with 2 mm thick CRCA Sheet , weather, dust and vermin proof ,floor mounted , IP-54 protection Class 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50x50x6mm angle iron frame (Height 0.40 mtr from Ground level) with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chamber ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following ( for Pump house):- a) MCCB , 63 Amp 04 pole 415v 25 KA with thermal magnetic release -01 No (Incoming) b)Automatic star delta starters suitable for 10 hp Pump sets -02 Nos c) MCCB TPN,40 Amps 415v, 10 KA - 03 No d) MCB SPN, 6-32 Amps 415v, 10 KA - 02 No e) Phase Indication lamp LED type for indicating R-Y-B phases. -set of three-01 No. f) Phase Indication lamp LED type for indicating ON / OFF for motor starters. -set of two-02 Nos. g) Busbar, Copper, 200 Amps for phases and neutral duly colour coded sleeves mounted on hygroscopic pvc insulator-01 set h) MF meter class 1 , Make L & T cat No. WL440531OOOO j) All necessary internal wiring as required. Note: The rate quote deemed to include the cost of dismantling the existing unserviceable LT panel board. Note - The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels for approval of GE before placing the order.
Taking down unserviceable existing submain wiring any size complete all as specified and directed.
M&L for submain wiring in and including PVC conduit ISI marked having minimum thickness 1.8 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 4 sqmm(FRLSH) and one run of PVC insulated, sheathed multistranded copper conductor 4 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 4 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green) Note- The rates of Scafolding, Overhead crane etc as per site requirement as height of hanger ceiling is 15 meter shall deemed to be included in the contractor's quoted rates.
Supply and laying cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) 50 sqmm 3.5 core with stranded aluminium conductor, 1100 Volts grade including taking down existing u/s LT cable of size complete all as specified and directed.
M & L for cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor/indoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 50 sqmm complete as specified and directed
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIS (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Fast Electrode or equivalent as approved by the GE. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also provided by the contractor .
Supply & Fix in repairs set of Cable trays (Each set must includes 5 Cable Trays and each cable tray legth will be 3 meter) manufactured from steel wires, welded together and bent into final shape.All cable trays, except the 30x50, shall be manufactured with a longitudinal ‘T-welded’ safety edge.Trays shall be constructed with a 50 mm x 100 mm mesh configuration. All Accessories including couplers (CE25/CE30 screw-based system combination) mounting accessories (Mechanically tested & supplied by cable tray manufacturer must be used) are required of same finish as per site requirement.Electro zinc plated after manufacture in accordance with the EN standard 12 329: at least 155 h of SST. All trays shall be arranged and positioned on the site itself in accordance with the manufacturer's instructions.The deflection of the wire cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537. Assemblies with specific fire-resistant properties must have an E30-E90 certificate issued by an approved laboratory in accordance with the tests described in the standard DIN 4102-12. The wire cable tray short-circuit resistance must be tested by an independent laboratory. For the purpose of assembling the various wire cable tray, only fast coupling systems or screw-based (CE25/CE30) systems must be used. These must be designed, mechanically tested and supplied by the wire cable tray manufacturer.The electrical resistance of the joints must not exceed 50 mtrs and must be tested in accordance with the procedure described in the standard IEC 61537.Rod dia must be from 3.9mm to 5.9mm for different sizes. Make - Legrand. Note- The rates of Scaffolding, Overhead crane etc as per site requirement shall deemed to be included in the contractor's quoted rates.
M&L for PCC TYPE D-2 1:4:8 using 40 mm graded aggregate as in cement concrete in foundations,filling and mass concrete all as specified and directed.
Taking down existing unserviceable street light fittings , all electrical connections all as specififed and directed.
Supply and fixing solar integrated system LED street light fitting 32 watt with Lithium ferrous phosphate battery dimming version(LFP),PIR inbuilt option of MPPT charge controller available solution with Li-Ion seperately available power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired with IP 66 or better ingress protection with inbuilt Lithium Battery 11.1V/12.8Volt 33Ah, provided with 2 LED indicators : a green light to indicate charging in progress and a red LED to indicate deep discharge condition of the battery, green LED glow only when the battery is actually being charged, battery included in the luminary enclosure, with water proof (IP 66 or better) and corrosion resistant, material of construction of solar light fitting shall be FRP, LED lamp 32 watt (W-LED, 180-200 lm/watt, CRI>70) with 120Degree vide angle lens for better light distribution and colour temp-5700-6500K, Solar PV Module mono crystalline, > = 66 Wp. complete including warranty for light fitting 2 years after completion of the work complete all as specified and dircted.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 16 Sqmm, 4 core complete all as specified.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and laying DWC HDPE pipes ISI marked of pressure rating 6 kgf/cm2 (PE-63 grade) of size 40 mm bore laid in trenches for passing of cable complete all as specified and directed.
Supply and laying DWC HDPE pipes ISI marked of pressure rating PN-10 of size 100 mm for the protection of the cable passing through road crossing, etc complete all as specified and directed.
Dismantling exsting RCC & steel tubular poles with bracket & light and in lieu S&F 5 metre long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 130 mm, made out of 3mm thick HT sheet alongwith base plate of size 220*220*12mm, including 1500mm long single arm bracket made out of 48mm dia, GI pipe, M20 in PCD 205mm, 700mm long and projected 100mm, "J" type EN8 grade set of 4 Nos foundation bolts alongwith templates, also including provision of the followings :- (a) MCB,SP,6A,230V, B series, 10KA mounted on and including 3mm thick plastic laminated sheet-01 No. (b) 4 way connector, bolt type having locking arrangement, weather proof and water proof control space : 01 No. Notes: (a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete of the pole concrete. (b) The earth work, RCC foundation reinforcement and form work will be measured and paid separately. (c) The quoted rate shall also be deemed to include for fixing of old light fitting retrived from dismantling. Make : Crompton/Philips / Wipro/Bajaj as approved by the GE.
Dismantling exsting RCC & steel tubular poles with bracket & light and in lieu S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70mm bottom A/F 130 mm, made out of 3mm thick HT sheet alongwith base plate of size 220*220*12mm, including 1500mm long single arm bracket made out of 48mm dia, GI pipe, M20 in PCD 205mm, 700mm long and projected 100mm, "J" type EN8 grade set of 4 Nos foundation bolts alongwith templates, also including provision of the followings :- (a) MCB,SP,6A,230V, B series, 10KA mounted on and including 3mm thick plastic laminated sheet-01 No. (b) 4 way connector, bolt type having locking arrangement, weather proof and water proof control space : 01 No. Notes: (a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete of the pole concrete. (b) The earth work, RCC foundation reinforcement and form work will be measured and paid separately. (c) The quoted rate shall also be deemed to include for fixing of old light fitting retrived from dismantling. Make : Crompton/Philips / Wipro/Bajaj as approved by the GE.
M&L for reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) for foundations, footings,columns, post, pillars etc & in any location, complete all as specified and directed.(Note:Reinforcement and form work will be measured and paid separetly)
M &L for TMT steel bars 10 mm dia and over in reinforcement cut to length,bent to shape required, including cracking bending spirally forhooping for coloumns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm di or ecuring with clips etc, complete all as specified and directed.
M&L for TMT steel bars 6 to 8 mm dia as in strirups, spacers,binders cut length bent to shape required, including cracking binding spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc,complete all as specified and directed.
M&L for use and waste of formwork to sides of concrete foundations,footing,columns posts pillars etc and in any location for fair finished surfaces,completeall as specified and directed.
Supply and fix 4 Mtr Double arm Decorative type tubular Pole made Di-Cast Aluminium having LED Lanterns 30 W IP 66 Protection PF 0.95, LED Luminous efficiency shall not be less than 90 per watt and colour rendering index shall not be less than 70, correlated colour temperature is 3500 K and luminous should be complying ISI & BIS Marking Covered with Glass including Cable connection of 3 core Copper wire not less than 2.5sqmm for . The Tubular pole of thickness not less 3mm made shall be painted with Zinc Phospate Primer coated over coloured paint all as per IS : 2713 (1980) suitable for street Roads all as directed by the Engineer-in-Charge make : Suncity/Bajaj/Surya As Approved by The GE. Note: The above pole cost Including of J bracket bolt of 04 Nos suitable size, and Provision of FRP Box shall be Concealed on Foundation with provision of Connector.Note :Excavation and Pole RCC Foundation work for each pole paid and measured Seperately.
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm medium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) Rs.67,820.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Radha Engineering Services
R J ENTERPRISES
Sujitha Infrastructure
S K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .