Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹29.8 L
Closing Date
26 Oct 2021, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_144546_1
Fresh e-NIT No.EDJ/121 of 2021-22 Dated 20-10-2021
Open Tender
Electrical Works
Item Rate
Govt Degree College for Women Parade
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
2 Nov 2021
20 Oct 2021
27 Oct 2021
21 Oct 2021
26 Oct 2021
21 Oct 2021
Amount
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .
14 HP X 4 Nos.
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessarysupports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature
Ceiling Suspended Ductable type Indoor units -Capacity 3.4 TR
Ceiling Mounted Cassette type Indoor units - Capacity 4.0 TR
Ceiling Mounted Cassette type Indoor units - Capacity 3.2 TR
Ceiling Mounted Cassette type Indoor units - Capacity 2.4 TR
Ceiling Mounted Cassette type Indoor units - Capacity 2.0 TR
Ceiling Mounted Cassette type Indoor units - Capacity 1.0 TR
Remote Controller Installation , testing and commissioning of corded remote controller suitable for Indoor units and suitable to work on single phase 230 volt (+) (-) 10% 50 Hz AC supply.
Refrigerant Joints/ Headers Installation , testing and commissioning of imported Y-joints fittings and header to all indoor units at all floors including alignments of joints complete as required.
Refrigerant Piping Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported /fixed with suitable size of clamps /M.S hanger and all exterinal /exposed to sun piping shall run in M.S.painted cable tray with cover at site
34.9 mm O.D. (insulation : 19mm)
31.8 mm O.D. (insulation : 19mm)
28.6 mm O.D. (insulation : 19 mm)
25.4mm O.D. (insulation : 19 mm)
22.2 mm O.D. (insulation : upto 19 mm)
19.1 mm O.D. (insulation : upto 19 mm)
15.9 mm O.D. (insulation : upto 19 mm)
12.7 mm O.D. (insulation : upto 19 mm)
9.53mm O.D. (insulation : upto 19 mm)
6.4 mm O.D. (insulation : upto 19 mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
Drain Piping Providing and fixing rigid CPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
32 mm dia
40 mm dia
Supply, Installation, Testing and commissioning of double layer canvas connection with fire rating.
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
0.63mm (24 gauge) GSS
0.50 mm (26 gauge) GSS
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0.032 W/m°K at an average temperature of 25°C. Density of the material shall be 25-30 Kg/m3.The product shall have temperature range of –40°C to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0.15ng/Pa.Sec.m.
9 mm thick insulation (Supply Air Duct)
SITC of Insulation material for Duct Acoustic Lining shall be resin bounded fiberglass wool with one side factory laminated either Black Glass Oven Cloth or Black Glass Tissue. The Thermal conductivity of the fiberglass for air-conditioning application shall not exceed 0.034 W/m°K at 25°C mean temperature and average Noise Reduction Coefficient (NRC=1, frequency range from100 Hz to 8000Hz ) .The density of insulation material shall be either 32 Kg/m3 and thickness of insulation material shall not less 25 mm.
13 mm thick Under deck insulation as per the specifications.
Control & Transmission Wiring Providing & fixing control wiring of 2 core x 1.5 sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance C/C where it is not recessed between indoor units.
Providing & fixing control wiring of 2 core x 1.0 sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance C/C where it is not recessed between indoor units and out door units
Providing & fixing of PVC Insulated and FR PVC Round sheathed Copper Conductor Cable of 4C X 10 Sq. mm in PVC Conduit of suitable size as per requirement.
Providing & fixing of PVC Insulated and FR PVC Round sheathed Copper Conductor Cable of 4C X 6 Sq. mm in PVC Conduit of suitable size as per requirement.
Providing & fixing of PVC Insulated and FR PVC Round sheathed Copper Conductor Cable of 3C X 2.5 Sq. mm in PVC Conduit of suitable size as per requirement.
Supply, installation, testing & commissioning of CPRI Approved maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and providing and laying of 2 Nos. 25 x 3 mm copper strip from copper rod upto the main panel. The earthing pit should be covered with PVC cover.
Providing and Additional Gas-410 being charged after processing the system charging
CAMC for 1 year after Defect Liability period
CAMC for 2 year after Defect Liability period
Yatha Consultants and Engineers
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .