Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-Finance 86 HARIDAS DUTTA ROAD JAYNAGAR DIST SOUTH 24 PARGANAS PIN 743337 | 24 PARAGANAS SOUTH | WEST BENGAL | 743337 | ₹2.7 L | L1 | Accepted-Finance L1 BIDDER |
| 2 | L2₹2.9 LAccepted-Finance 722 NETAJI BLOCK P O CHOWHATI P S SONARPUR DIST SOUTH 24 PARGANAS PIN 700149 | SONARPUR | SOUTH 24 PARGANAS | WEST BENGAL | 700149 | ₹2.9 L | L2 | Accepted-Finance L2 BIDDER |
| 3 | L3₹3.4 LRejected-Finance SAMABAY SARANI LANE HARIHARPUR DHANKOIL P O KALIYAGANJ DIST UTTAR DINAJPUR | DINAJPUR UTTAR | WEST BENGAL | 733123 | ₹3.4 L | L3 | Rejected-Finance L3 BIDDER |
| 4 | L4₹3.5 LRejected-Finance BOICHIPOTA ANANDANAGAR SINGUR DIST HOOGHLY PIN 712409 WEST BENGAL | SINGUR | HOOGHLY | WEST BENGAL | 712409 | ₹3.5 L | L4 | Rejected-Finance L4 BIDDER |
Tender Value
₹6.0 L
EMD Value
₹12,042
Closing Date
2 Mar 2026, 12:05 pmClosed
EE/MHD
MIDNAPORE
Geotechnical Investigation Report for Rehabilatation or New Construction of Existing Abutment along with its adjacent span and construction of New Bridge at Khukurdaha at 9.900 KM of Panskura -Ghatal Road under Midnapore Highway Division in the distr
2026_WBPWD_1010651_1
WBPWD/RD/EE/MHD/NIT-20/2025-26
Open Tender
CIVIL WORKS
15 days
MIDNAPORE
Please refer Tender documents.
4 documents required · 4 mandatory
₹12,042
Yes
24 Mar 2026
19 Feb 2026
5 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
Mobilisation Charges of all tools & Plants along with accessories, material, labour, supervision etc. at site of work required in connection with boring and testing work, including setting up boring rigs and shifting to different Bore-hole points etc. and also including withdrawal of same from the site after completion of work, complete as per direction of Engineer-in-Charge. Detailed Investigation
Carriage of all Disturbed & Undisturbed Samples from site of work to the Divisional office or elsewhere including loading and unloading as per direction of Engineer-in-Charge. Detailed Investigation. (Note: Some samples are to be kept at Sub-Division Office for Additional testing By the Engineer-in-Charge.)
Labour for making Bore-Holes of 150mm to 250mm dia. by any standard method to any depth below ground level / bed level in all kinds of soil like clay, , silt, sand, stiff clay, mixed soils etc. except rocks (for the purpose of collecting Disturbed & Un disturbed soil samples, conducting Standard Penetration Test at suitable intervals etc.) including preparation and submission of bore-log as per IRC : 75 and 78 and Clause 2400 of Specifications for Road & Bridge Works (5th Revision), Published by IRC, and also including hire charges of tools and plants complete as per the direction of Engineer-in-Charge. When Casing pipe is used to prevent collapse of bore hole (casing pipe to be finally withdrawn) Depth 0m to 10m
Depth greater than 10m and upto 20m
Depth greater than 20m and upto 30m
Depth greater than 30m. and upto 40m
Depth greater than 40m and upto 50m
Extra for boring in water (1.2m and higher depths). each 10670.00 11420.00
Laboratory Investigation: Liquid Limit as per IS 2720 (Part – V).
Plastic Limit as per IS 2720 (Part – V)
Grain size analysis by Sieving as per IS 2720 (Part – IV)
Grain size analysis by Hydrometer Method as per IS 2720 (Part – IV).
Determination of Water Content as per IS 2720 (Part – II).
Determination of Specific Gravity as per IS 2720 (Part – III).
Direct Shear Test as per IS 2720 (Part – XIII).
Determination of Unconfined Compression Strength as per IS 2720 (Part – X). Undisturbed.
Remoulded.
Determination of Water Content Dry Density relation using heavy compaction as per IS 2720 (Part – VIII).
Determination of Consolidation Properties as per IS 2720 (Part – XIV).
Tri-Axial Shear Test. Determination of Shear strength Parameters of a specimen tested in Unconsolidated Undrained Tri-axial compression without measurement of pore water pressure as per IS 2720 (Part –XI).
Determination of Shear strength Parameters of a specimen tested in Consolidated Undrained Tri-axial compression Test with measurement of pore water pressure as per IS 2720 (Part – XII).
Determination of Shear strength Parameters of a soil from Consolidated Drained Test as per IS 2720 (Part – X).
Laboratory Vane Shear Test as per IS 2720 (Part-XVIII).
Field Investigation: Collection of Samples from the bore hole made as per B-a Undisturbed
Disturbed
Standard Penetration Tests (S.P.T.) by Split Spoon Sampler in the bore hole as per IS 2131. 0.0m - 10.0m
Preparation and submission of report in 6 (Six) copies, giving all relevant information data like site plan, Bore log and water table, test results, calculations, discussions, suggestions and recommendations in respect of suitable foundation etc. including determination of silt factor calculation of waterways and complete design of foundation including analysis of Bearing Capacities and settlements in bound and presentable form complete as per direction of Engineer-in-Charge. Detailed Investigation
GST @ 18% on Item no 1.00 to 6.00
Labour Welfare Cess @ 1% on Item no 1.00 to 7.00
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
Tendernotice_2.pdf
PDF • 1.27 MB
Tendernotice_3.pdf
PDF • 0.63 MB
BOQ_2481473.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid