Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹86.9 LAccepted-AOC 56 ARUNACHALAM MAIN ROAD AMBAL NAGAR PORUR CHENNAI TAMIL NADU 600116 | THIRUVALLUR | TAMIL NADU | 600116 | 1 | Accepted-AOC l1 | |
| 2 | Rejected-Technical 150 VILLARASAMPATIBALL ROAD PO NASIYANUR ROAD ERODE 638107 TAMIL NADU | ERODE | ERODE | TAMIL NADU | 638107 | - | Rejected-Technical BQR condition not satisfied |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
15 Feb 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer/Hydro
5th floor, Eastern wing, NPKRR maaligai, 144, Annasalai, Chennai-2
Rectification and replacement including Re-insulation of defective stator coils (Top and Bottom) in all Phases including supervision, erection, testing and Commissioning of 100 MW Generator of Unit III of KADAMPARAI Power House
2021_EB_194310_1
HE-2398
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Kadamparai Power House
Refer tender documents
4 documents required · 4 mandatory
₹0
₹82,000
Yes
13 Jun 2023
8 Feb 2021
16 Feb 2021
8 Feb 2021
15 Feb 2021
8 Feb 2021
180 days
Amount
Charges towards dismantling the pipes, sprinkler system, checkered plates, beams, channels, etc. for facilitating the dismantling of stator air guides, stator bars and rotor poles.
Charges towards making of continuity of other coils in the circuit, testing the whole Generator to ascertain the healthiness of other coils. i) IR value at 5 KV megger before and after HV AC test. ii) HV AC as per instruction of field engineers. iii) PI value at 5 KV megger.
Charges towards de-soldering both the pole jumpers, removing the ‘ V ‘ block and damper coils series link.
Charges towards removing the 8 Nos. static key and 8 Nos. sliding key per pole with special jigs and hydraulic jacks.
Charges towards lifting of 4 Nos. rotor poles after ensuring all connections are disconnected and by using suitable lifting device.
Charges towards removing the top coils by de-wedging and removing the overhang bandings with special jigs and fixtures.
Charges towards removing the bottom coils by de-wedging and removing the overhang bandings with special jigs and fixtures.
Charges towards removing the old failed insulation and re-insulating with Class F insulation on both sides of overhang portion of the released top coils (slot areas) and testing the top coils. The following tests are to be carried out : i) IR value at 5 KV before HVAC test ii) HVAC test at 18 KV iii) IR value at 5 KV after HVAC test
Charges towards installing the spare / re-insulated tested bottom coils with Class F insulation (Spare coils shall be supplied by TANGEDCO) with using fresh liners, end banding the overhang portion with fiber tapes and cards using the binding cement of epoxy resin.
Charges towards installing the spare / re-insulated tested top coils with Class F insulation (Spare coils shall be supplied by TANGEDCO) with using fresh liners, wedges, end banding the overhang portion with fiber tapes and cards using the binding cement of epoxy resin.
Charges for supply of Class F new top stator coils Note :if sufficient spare healthy top coils are not supplied by TANGEDCO then this supply portion is required. (Optional)
Charges for re-positioning the pole in the rotor spider, locking the keys, fixing the ’V’ blocks with suitable insulation.
Charges for making end connection, locking the jumpers and connection links with suitable insulated locks, soldering the end connection.
Charges for cleaning of stator and rotor windings and drying out.
Charges for following test on stator and rotor: Stator: i) IR value at 5 KV megger before and after HV AC test. ii) HV AC as per instruction of field engineers iii) PI value at 5 KV megger. iv) PI value v) Winding resistance vi) Tan Delta at 11 KV in the steps of 0.2VL, 0.4VL, 0.6VL, 0.8VL and 1.0 VL. Rotor: i) IR value at 500 V ii) Winding resistance iii) Surge test at 1 KV iv) AC Drop test
Charges for Dynamic in-situ balancing test and vibration test of whole rotor assembly .
Charges for assembling the stator top and bottom air guides, checker plates and commissioning the Generator.
CGST in % (For Bidders inside TamilNadu)
SGST in % (For Bidders inside TamilNadu)
IGST in % (For Bidders outside TamilNadu)
Coral rewinding India Private Limited
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .