Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC ANURAGPUR PO PANAGARH BAZAR DIST BURDWAN WEST BENGAL 713 148 | PANAGARH BAZAR | BURDWAN | WEST BENGAL | 713148 | L1 | Accepted-AOC Lower rate quoted | |
| 2 | L2₹25.1 L+₹33,461.50 (1.35%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹26.4 L+₹1.7 L (6.82%)Rejected-Finance 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹27.2 L+₹2.5 L (9.92%)Rejected-Finance OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L4 | Rejected-Finance Higher rate quoted | |
| 5 | L5₹30.0 L+₹5.2 L (21.2%)Rejected-Finance | L5 | Rejected-Finance Higher rate quoted |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_474206_1
8400-673/E8
Open Tender
Civil Works - Water Works
Works
180 days
PANAGARH
Class D, Cat a (ii)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹70,000
Yes
18 Nov 2021
10 Sept 2021
11 Oct 2021
10 Sept 2021
7 Oct 2021
23 Sept 2021
60 days
Amount
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line ,complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Taking up CI/DI water main (incl all fitting) with spigot & socket ends and lead joints incl burning out & recovering lead from pipe of 80 mm bore for relaying / rerouting of serviceable pipe after cleaning complete all as specified and directed.
All as per item No 4.00 mentioned here-in- above but 100 mm bore.complete all as specified and directed.
All as per item No 4.00 mentioned here-in- before but 150 mm bore.complete all as specified and directed.
Relaying of DI/CI/GI pipe 80 mm bore in trenches/ over the masonry pillars after cleaning thoroughly including fittings complete all as specified and directed.
All as per item No 7.00 mentioned here-in-above but 100 mm bore.complete all as specified and directed.
All as per item No 7.00 mentioned here-in-above but 150 mm bore.complete all as specified and directed.
M&L for DI pipe of 80 mm bore with spigot and socket end rubber gascate joint(titon) centrifugally cast class k-7 conforming to IS 8329-2000 laid in trenches/ on surface/ over masonry pillar and connection to old or new position complete all as directed. Cost of joint included in the qoted rate.complete all as specified and directed.
All as per item No 10.00 mentioned here-in-above but 100 mm bore.complete all as specified and directed.
All as per item No 10.00 mentioned here-in-above but 150 mm bore.complete all as specified and directed.
Taking up or down 50 mm bore steel tubing and connection including cleaning for relaying or removal to store from trenches/wall surfaces complete all as specified and directed.
All as per item No 13.00 mentioned here-in-above but bore of Pipe 40 mm complete all as specified and directed.
All as per item No 13.00 mentioned here-in-above but bore of Pipe 25 mm complete all as specified and directed.
All as per item No 13.00 mentioned here-in-above but bore of Pipe 20 mm , complete all as specified and directed.
Relaying/re-fixing old 50 mm bore GI tubing or in floor/pillar/wall in new or old position , complete all as specified and directed.
All as per item No 17.00 mentioned here-in-above but bore of Pipe 40 mm.complete all as specified and directed.
All as per item No 17.00 mentioned here-in-above but bore of Pipe 25 mm.complete all as specified and directed.
All as per item No 17.00 mentioned here-in-above but bore of Pipe 20 mm.complete all as specified and directed.
M&L for 50 mm bore GI Tubing medium grade in Trenches/ Floor/ Pillar and connection in old or news position including fitting like socket /Union/Tee/ Reducer Nipple etc complete required will be supplied by Contractor rate for the same is included in the item rate quoted,complete all as specified and directed.
All as per item No 21.00 mentioned here-in-before but bore 40 mm complete all as specified and directed
All as per item No 21.00 mentioned here-in-before but bore 25 mm complete all as specified and directed.
All as per item No 21.00 mentioned here-in-before but bore 20 mm complete all as specified and directed
M&L for CI bend any type, radius and angles, tappers and type (straight, bend, increasing, decreasing, or double socket etc. Tee pipes single branch Y junction, double branch cross (all socket, socket and Spigot or flanged ends) collors, caps and plugs for the Pipes socket and Spigot. All socket and flanged upto bore of 150 mm, complete all as specified and directed. (Note:-Lead/gasket for fitting shall be measured and paid separately.)
M&L for rubber gasket joint in repair for 80 mm bore CI/DI Pipe with Spigot & Socket ends after connection of old and new position, complete all as specified and directed.
All as per item No 26.00 mentioned here-in-above but size 100 mm bore complete all as specified and directed.
All as per item No 26.00 mentioned here-in-above but size 150 mm bore complete all as specified and directed.
Taking of existing U/S CI Sluice valve of any size, any type from 80 mm bore upto 200 mm bore complete all as specified and directed.
S&F 100 mm bore CI Sluice valve PN – 1.6 IS 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/fiber gasket and fixed in position complete all as specified and directed.
All as per item No 30.00 mentioned here-in- above item but 150 mm bore complete all as specified and directed.
Refixing of Sluice valve 150 mm bore after taking out, refacing of valve spindle,re grinding, including taking part and reassembling, as per existing and complete scaling and proper functioning at site including replacement of nuts, bolts, washers and gasket as required at site complete all as specified and directed.
All as per item No 32.00 mentioned here-in- above item but size 100 mm bore complete all as specified and directed.
M&L for 50 mm bore gate valve gum metal class-II screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as specified and directed.
All as per item No 34.00 mentioned here-in- above item but size 40 mm bore complete all as specified and directed.
All as per item No 34.00 mentioned here-in- above item but size 25 mm bore complete all as specified and directed.
All as per item No 34.00 mentioned here-in- above item but size 20 mm bore complete all as specified and directed.
M&L for in repair/rectification of leakage in existing rising/delivery CI/DI Pipe Spigot/ socketed end of 100 mm bore including necessary earth work (i.e. excavation, removal & refilling, of trench), Pumping out water from the ditch and rectify the defects by taking out of existing lead and rejoining The same by using necessary additional lead, Lead Wool, Spun Yarn & etc including testing, commissioning of CI Pipe line complete all as specified and directed. Spun yarn & other arrangement for rectification of said defects is included in the cost of item complete).
All as per item No 38.00 mentioned here-in- above item but size 150 mm bore complete all as specified and directed
M&L for in repair/rectification in existing rising/ delivery CI/GI pipe line flanged end type of 100 mm bore incl necessory earth work (i.e. excavation, rubber sheet nut & bolts etc and other arrangement for rectification of said deffects is included in the cost of item complete Removal and refilling of trenches). Pumpimg out water from the ditch and rectify the deffects by taking out of existing rubber gasket / fibre sheet, nut & bolt etc and rejoining the same by using new one incl testing, commissioning of CI pipe line complete all as specified and directed.
All as per item No 40.00 mentioned here-in- above item but size 150 mm bore complete all as specified and directed.
Supply and fix in repair Cast Iron air released valve with two air outlet (IS 14845-2000 DK fig-4 )and fixing up in water main of 150 mm dia with all fitting accessories , complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation of pillar complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in coping on brick machinary on of pillar and like complete all as specified and directed.
M&L for brick work in cum (1:6) as brick pillar for resting of CI pipe line complete all as specified and directed.
M&L for 15 mm thick cement plaster in cement mortar (1:6) on brick surface fair and even, complete all as specified and directed.
M&L for brick massonary valve pit with brick in cement mortar (1:6) with 100mm thick PCC work (1:3:6) type C-2 (using 40 mm graded stone aggregate) for fundation over 75mm thick hard core, sub class B brick full brick thick wall, 15mm thick in cement mortar (1:4) internal and external plaster at bottom of the pit of size 1200x1200x900 mm along with valve pit cover made out MS angle iron 50mm x 50mm x 6mm frame work, , MS plate cover made out of 3.15mm thick with locking arrangment fixed over the valve pit including a coat of synthetic enamel paint over a coat of red oxide primer complete including necessary frame work welding, drilling etc, complete all as specified and directed.
S&F PVC Tank Cover (Best Quality) Suitable for Cylindrical Vertical Storage Tank of sizes 300 Ltrs to 2000 Ltrs capacity.incl tank holes hinges fitted any type complete all as directed. Note :- Size of Covers. (a) 300 Ltrs -04 Nos. (b) 500 Ltrs - 49 Nos. (c) 1000 Ltrs - 8 Nos. (d) 2000 Ltrs - 2 Nos.
S&F 500 ltr rotational moulded polyethylene water storage tank (Cylendrical, vertical with closed top with double layer conf to IS-12701-96 complete including provision of all inlet,outlet,overflow and drain pipe fitting,after disconnection and taking out from site complete all as specified and directed.
All as per item No 49.00 mentioned here-in-above but capacity 1000 ltrs complete all as specified and directed.
All as per item No 49.00 mentioned here-in-above but capacity 2000 ltrs complete all as specified and directed.
All as per item No 49.00 mentioned here-in-above but capacity 2000 ltrs complete all as specified and directed.
S&F high pressure PTMT ball float valve suitable for size of 25 mm dia with epoxy coated aluminum rod & HD plastic ball screwed for iron pipe including GI Fitting as reqd after taking out old u/s item, complete all as specified and directed.
All as per item No 53.00 mentioned here-in-before but size 20 mm bore complete all as specified and directed.
Cleaning overhead building service water tank (capacity of upto -5000 ltrs ) by high pressure and disinfections by ultraviolet radations and disposal of sludge at safe place. Rate also includes all labour, materials, equipment, plants and mechinery etc complete in all respect. Total process of the cleaning comprises of following steps. (i) Cleaning of initial sludge and sedimentation etc and disposal of sludge insludge tank carefully. (ii) Total high pressure cleanig with machines using special rotary high pressure cleaning for total removal of scaling, dirt and algae etc from the walls, pillars and flooring to thoroughly expose the original concrete wall/surface. (iii) Removal of sludge by labours. (iv) Removal of dirt, fine mud and fine particles etc. by industrial vaccum cleaner. (v) Sterilisation of all walls, flooring and pillar by special anti bacterial agents for reductions of microbiological impurities. (vi) Final disinfection by special industrial ultraviolet radiations to ensure complete sterlisation of tanks. Note :- (i) Rate are deemed for writing work i.e. tank clean on (date), (month) and (year), font size should be 60 cms. (ii) Any damages of float valves and tanks due to negligence of work will be rectified by the contactor is own cost.
S&F framed work such as angle of different size gusset plate (mildsteel) and cut to shape drilled and conter inner for screwing inclnbending and weldidng angle as necessary confirming to Fe-410-W(Gde E-250) Quality-B, complete all as specified and directed.
M & L for preparation of new steel surface of any description over 10cm width or girth not other wise described and appplying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
S&F 3.15mm thick mild steel plain black sheet for earth, covering to door shutters, and covering to valve pit frame cut size edges beaded as directed , holes punched, inclding rounded head serews with plain 40mm lap, joints or welded/ reveted seams including bending, turning up mitred angle, stoped ends, outlets as required, complete all as specified and directed.
Jaibalaji Enterprise
UNITED BUILDERS
M/S Ali Trading Co
M/S BISWAS AND KUNDU CONSTRUCTION
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .