Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.8 L+₹1.7 L (5.38%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹33.3 L+₹2.2 L (6.91%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹33.9 L+₹2.8 L (8.92%)Rejected-Finance 369 KRISHNA BHAVAN DHARMSALA ROAD CINEMA CHURAHA HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹34.6 L+₹3.4 L (10.9%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | Sanjai sales and services L2 | Prime power system L3 | M/s Vatsh Raj and co L5 | M/s A.K Construction L7 | OMVIN ENTERPRISES LLP L1 | GYAN ENTERPRISES L8 | M I & CO. L6 | Sai Solar Power L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 metre deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge. | 1,032 | Cum | 135 ₹1,39,320 | 100 ₹1,03,200 | 80 ₹82,560 | 80 ₹82,560 | 100 ₹1,03,200 | 230 ₹2,37,360 | 51 ₹52,632 | 22 ₹22,704 Lowest |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and as directed. | 629 | Cum | 68.5 ₹43,086.5 | 45 ₹28,305 | 45 ₹28,305 | 60 ₹37,740 | 20 ₹12,580 Lowest | 100 ₹62,900 | 46 ₹28,934 | 22 ₹13,838 |
| 3.00 | Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. | 403 | Cum | 48.5 ₹19,545.5 | 50 ₹20,150 | 46 ₹18,538 | 50 ₹20,150 | 20 ₹8,060 Lowest | 80 ₹32,240 | 40 ₹16,120 | 22 ₹8,866 |
| 4.00 | M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed.
Note: Punned thickness (18 cm) shall be consider for measurement purpose | 310 | Cum | 375 ₹1,16,250 | 500 ₹1,55,000 | 400 ₹1,24,000 | 360 ₹1,11,600 | 350 ₹1,08,500 | 450 ₹1,39,500 | 260 ₹80,600 | 150 ₹46,500 Lowest |
| 5.00 | M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge. | 34 | per 1000 Nos | 4,850 ₹1,64,900 | 5,000 ₹1,70,000 | 5,500 ₹1,87,000 | 4,750 ₹1,61,500 | 3,800 ₹1,29,200 Lowest | 5,900 ₹2,00,600 | 4,600 ₹1,56,400 | 5,500 ₹1,87,000 |
| 6.00 | M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge | 0.5 | Cum | 1,159 ₹579.5 | 150 ₹75 | 85 ₹42.5 Lowest | 2,000 ₹1,000 | 500 ₹250 | 5,000 ₹2,500 | 6,000 ₹3,000 | 5,000 ₹2,500 |
| 7.00 | Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads/path/hardstanding etc complete all as specified and as directed by Engineer-in-Charge. | 0.5 | Cum | 4,458 ₹2,229 | 3,000 ₹1,500 Lowest | 3,800 ₹1,900 | 3,650 ₹1,825 | 5,000 ₹2,500 | 3,500 ₹1,750 | 6,500 ₹3,250 | 6,000 ₹3,000 |
| 8.00 | Deployment of tools & manpower for Boring /drilling (Horizontal) manually / mechanically under existing road max 10 M in width) suitable for passing pipe of any description of dia 40 to 100 mm complete all as specified and directed by Engineer in Charge | 80 | RM | 485 ₹38,800 | 50 ₹4,000 Lowest | 110 ₹8,800 | 160 ₹12,800 | 600 ₹48,000 | 500 ₹40,000 | 150 ₹12,000 | 200 ₹16,000 |
| 9.00 | M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge. | 25 | RM | 489 ₹12,225 | 400 ₹10,000 | 310 ₹7,750 Lowest | 320 ₹8,000 | 600 ₹15,000 | 975 ₹24,375 | 400 ₹10,000 | 500 ₹12,500 |
| 10.00 | M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge. | 20 | RM | 338 ₹6,760 | 300 ₹6,000 | 280 ₹5,600 | 220 ₹4,400 Lowest | 400 ₹8,000 | 675 ₹13,500 | 390 ₹7,800 | 500 ₹10,000 |
Tender Value
₹37.9 L
EMD Value
₹75,720
Closing Date
18 Dec 2025, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPL REPAIR FOR CONVERSION OF OVER HEAD CONDUCTOR WITH UNDERGROUND CABLE INCLUDING CONNECTED ITEMS NEAR AT CCSR, HAVELOK LINE, TPT COY, 215 FD WKSP, OUTRUM LINE AND NEAR WEST OF MG ROAD UNDER GE E/M LUCKNOW
2025_MES_741796_1
GE/EM/LKO/EXT(ELECT)/T-48 OF 2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹75,720
Yes
19 Feb 2026
27 Nov 2025
20 Dec 2025
27 Nov 2025
18 Dec 2025
11 Dec 2025
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 metre deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and as directed.
Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
S&F Factory made RCC cable route marker with mix of concrete 1:2:4, size 750 mm x 300 mm x 75 mm (length x width x thickness), dully engraved "LT Cable" including applying two coat synthetic enamel paint in brown colour, over one coat primer, and engraved letter painted with black synthetic enamel paint, fixed in ground including excavation, earthwork, and removal of surplus soil complete all as specified & directed By Engineer-in-Charge.
M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads/path/hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness (18 cm) shall be consider for measurement purpose
All as per item No 12 above but LT UG cable of size 16 Sqmm 2 core.
All as per item No 12 above but LT UG cable of size 16 Sqmm 4 core.
All as per item No 12 above but LT UG cable of size 25 Sqmm 4 core.
All as per item No 12 above but LT UG cable of size 35 Sqmm 3.5 core.
All as per item No 12 above but LT UG cable of size 50 Sqmm 3.5 core.
All as per item No 12 above but LT UG cable of size 70 Sqmm 3.5 core.
All as per item No 12 above but LT UG cable of size 95 Sqmm 3.5 core.
All as per item No 12 above but LT UG cable of size 120 Sqmm 3.5 core.
Supply and fix Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 / 4 core 25 to 50 Sqmm, complete all as specified & directed.
Supply drawing, connecting and testing 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Supply, laying jointing and testing LT UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, laid in trench / laid under floor or fixed naked with wall / on wall / in ducts / in GI pipes etc. with and includings MS Clamps, nuts, bolts,washers complete all as specified and directed. Note- Excation, earth works, sand cushioning, protection bricks / pipe shall be measured and paid seprately.
(a) Incoming :- (i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA,,Ics=100%Icu with thermal magnetic release - 01 Nos (iii) Digital VAF+PF meter with RS 485 CL1 -01No (iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
M&L for out door type busbar panel board (Dimention of Cubical/enclosure not less than 900mmx600mmx450mm) made out of 3.00 mm thick MS sheet and MS angle section 50x50x6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 160 Amps 27 KA, ,Ics=100%Icu 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three. (d) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The hight of platform shall be 45 cm above the nearest road level.
Note - (i) Following type test certificate for panel with switchgear as per IEC 61439 Part I & II shall be obtained from panel manufacturer by the contractor and shall be submitted along with panel Drawing for the approval the GE before supply of panel at site. A - Construction Requirement: (a) Strength of material and parts (b) Degree of protection of enclosures (c) Clearances (d) Creepage distances (e) Protection against electric shock and integrity of protective circuits (f) Incorporation of switching devices and components (g) Internal electrical circuits and connections (h) Terminals for external conductors B - Performance Requirement: (a) Di-electric properties (b) Verification of temperature rise (c) Short circuit withstand strength (d) Electromagnetic compatibility (e) Mechanical operations
Note (ii) All out going feeder shall be connected by cable through suitable size gland plate / glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer (v) The enclosures shall be designed to take care of normal stress as well as abnormal electromechanical stress due to short circuit conditions. All covers and doors provided shall offer adequate safety to operating persons and provide ingress protection upto IP 54 unless otherwise stated. Ventilating openings and vent outlets, shall be arranged such that same ingress protection of IP 54 is retained. Suitable pressure relief devices shall be provided to minimize danger to operator during internal fault conditions. (vi) MCCBs upto 160A should have operating voltage 415V AC class II insulation, Line Load Reversibility , ICS=100%ICU , ROHS Compliant.
(a) Incoming :- (i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole ,160 Amps,50 Hz,415 Volts, 27KA,Ics=100%Icu thermal magnetic release - 02 Nos (ii) MCCB 4 pole ,125Amps,50 Hz,415 Volts, 27 KA,Ics=100%Icu thermal magnetic release - 02 Nos (iii) MCCB 4 pole ,63 Amps,50 Hz,415 Volts, 27 KA,Ics=100%Icu thermal magnetic release - 02 Nos Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(a) Incoming :- (ii) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (iii) Digital VAF+P
(b) Outgoing (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 01 Nos (ii) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 27 KA thermal magnetic release - 05 Nos Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 03 Nos (ii) MCCB 4 pole, 200 Amps, 50 Hz, 415 volts, 36 KA, thermal magnetic release-01 No Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
(b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 03 Nos (ii) MCCB 4 pole, 200 Amps, 50 Hz, 415 volts, 36 KA, thermal magnetic release-01 No Note for MCCB : All incoming & outgoing MCCB shall have double make, double break with Arc Chute per pole.
Dismantling taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and as directed by Engineer-in-Charge.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of any size and setting a side complete all as specified and as directed by Engineer-in-Charge.
Dismantling of insulators any type and any size complete all as specified and as directed by Engineer-in-Charge.
F meter with RS 485 CL1 -01No (iv) CTs ratio 320/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_830648.xls
BOQ • 0.41 MB
Tender48.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .