| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | ₹6.7 L | L1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates |
| 2 | L2₹7.4 LRejected-Finance | ₹7.4 L | L2 | Rejected-Finance Higher side quoted amount |
| 3 | L3₹8.0 LRejected-Finance | ₹8.0 L | L3 | Rejected-Finance Higher side quoted amount |
| 4 | L4₹11.9 LRejected-Finance | ₹11.9 L | L4 | Rejected-Finance Higher side quoted amount |
| Sl No | Description | Qty | Unit | Vishav Karma Refrigeration and Electric Work L4 | GARG CONSTRUCTION CO L1 | SURINDER SINGH AND BROS L2 | M/S NILESH ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Attending the received/recorded complaints lodged by occupent for the not functioning/breakdown of AC/Refrigerator/Deep freezer/water coolar/desert cooler any type including taking down and dismantling with complete address all alongwith nature of fault and stores required. The contractor will collect the complain from the concern JE and will attend the complain as per the address and make good the faulty appliance (i.e. AC window/split, refrigrator/deep freezer of any capacity and make and type) The parts required to replacement will be measured in S&F in respective items for payment complete all as specified and directed by Engineer-in-Charge. (Note:- (i) any accessories found unserviceable will be replaced and shall be paid under S&F under respective items of this Sch 'A' . (ii) The contractor shall depute necessary man power/Technician on required basis for rectifying the jobs including Sundays & holidays . (iii) Not deploying the sufficient manpower/Technican to attend the complaint on same day or just next day the recovery will be made @150 per complain/day after that. | 150 | Each | 99 ₹14,850 | 50 ₹7,500 | 100 ₹15,000 | 50 ₹7,500 |
| 2.00 | Taking down defective AC , window type of capacity upto 2 ton of any make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary/ reciprocating compressor unit from AC and replacing the same with new compressor of existing specification including gas charging, transporting back to site, intalling and testing complete all as specified and directed. Make: TOTALLINE/HIGHLY/Voltas | 4 | Each | 16,999 ₹67,996 | 6,500 ₹26,000 | 8,000 ₹32,000 | 9,500 ₹38,000 |
| 3.00 | S&F in replacement Starting relay for window AC, split AC fixed in repair all as specified and directed. Make: HITECH/SHRIRAM. | 4 | Each | 349 ₹1,396 | 100 ₹400 | 300 ₹1,200 | 200 ₹800 |
| 4.00 | S&F in replacement Thermostate switch for window AC, hot and cold type complete all as specified and directed. Make: Denfos/Indofos. | 4 | Each | 249 ₹996 | 100 ₹400 | 260 ₹1,040 | 150 ₹600 |
| 5.00 | S&F Swing motor for window type AC / split type AC of capacity upto 2.0 ton as per existing make LG/Voltas/whirlpool/Carrier complete all as specified and directed. | 5 | Each | 649 ₹3,245 | 100 ₹500 | 270 ₹1,350 | 150 ₹750 |
| 6.00 | S&F Running capacitor 50+2 to 6 MFD (ISI Marked) 440VAC for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed. Make: Epcos/Tibcon/Havells | 10 | Each | 549 ₹5,490 | 200 ₹2,000 | 400 ₹4,000 | 50 ₹500 |
| 7.00 | S&F Running capacitor 45+2 to 6 MFD (ISI Marked) 440VAC for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed.. Make: Epcos/Tibcon. | 6 | Each | 499 ₹2,994 | 200 ₹1,200 | 350 ₹2,100 | 50 ₹300 |
| 8.00 | S&F Running capacitor 36+2, to 6 MFD (ISI Marked) 440VAC for window AC 1.5/2 Ton fixed in repair all as specified and directed. Make: Epcos/Tibcon. | 6 | Each | 449 ₹2,694 | 200 ₹1,200 | 300 ₹1,800 | 50 ₹300 |
| 9.00 | S&F Front grill of window AC, capacity 1.5/2 ton suitable for make LG/ Carrier/ Sidwal/ Whirlpool as per existing fixed in repair complete all as specified and directed. | 5 | Each | 1,999 ₹9,995 | 950 ₹4,750 | 800 ₹4,000 | 500 ₹2,500 |
| 10.00 | S&F Condensing fan of window type AC of capacity 1.5/2 ton as per existing fixed in repair complete all as specified and directed. MAKE -LG/VOLTAS/CARRIER | 5 | Each | 899 ₹4,495 | 300 ₹1,500 | 450 ₹2,250 | 350 ₹1,750 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
19 Jan 2026, 6:00 pmClosed
GE(W)PATHANKOT
GE(W)PATHANKOT
REPAIR AND MAINTENANCE TO SUMMER APPLIANCES, DESERT COOLER, DEEP FREEZER, REFRIGERATOR AND ALLIED SERVICES UNDER GE(W)PATHANKOT
2025_MES_745309_1
GE/PKT-88/25-26
Open Tender
Miscellaneous Works
180 days
GE(W)PATHANKOT
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE(W)PATHANKOT
₹20,000
16 Mar 2026
20 Dec 2025
20 Jan 2026
20 Dec 2025
19 Jan 2026
3 Jan 2026
S&F in replacement bottle support for Refrigerator as per suitable size complete all as specified and directed.
Taking down defective AC , window type of capacity upto 2 ton of any make after disconnecting electric connections and transporting to workshop from site, dismantling the AC and taking out burnt rotary/ reciprocating compressor unit from AC and replacing the same with new compressor of existing specification including gas charging, transporting back to site, intalling and testing complete all as specified and directed. Make: TOTALLINE/HIGHLY/Voltas
S&F in replacement Starting relay for window AC, split AC fixed in repair all as specified and directed. Make: HITECH/SHRIRAM.
S&F in replacement Thermostate switch for window AC, hot and cold type complete all as specified and directed. Make: Denfos/Indofos.
S&F Swing motor for window type AC / split type AC of capacity upto 2.0 ton as per existing make LG/Voltas/whirlpool/Carrier complete all as specified and directed.
S&F Running capacitor 50+2 to 6 MFD (ISI Marked) 440VAC for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed. Make: Epcos/Tibcon/Havells
S&F Running capacitor 45+2 to 6 MFD (ISI Marked) 440VAC for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed.. Make: Epcos/Tibcon.
S&F Running capacitor 36+2, to 6 MFD (ISI Marked) 440VAC for window AC 1.5/2 Ton fixed in repair all as specified and directed. Make: Epcos/Tibcon.
S&F Front grill of window AC, capacity 1.5/2 ton suitable for make LG/ Carrier/ Sidwal/ Whirlpool as per existing fixed in repair complete all as specified and directed.
S&F Condensing fan of window type AC of capacity 1.5/2 ton as per existing fixed in repair complete all as specified and directed. MAKE -LG/VOLTAS/CARRIER
S&F Blower fan of window type AC of capacity 1.5/2 ton as per existing fixed in repair complete all as specified and directed.
S&F in replacement single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps with breaking cap 10kA complete all as specified and directed. Make: L&T, Havells, standard, Indoasian
Servicing of window type AC/split type AC of capacity 1.5/2 ton of any make at site with complete washing/ removing of dust from blower fan and necessary oiling the blower motor complete all as specified and directed.
S&F in replacement of unsv Blower Motor (ISI marked) as per existing capacity for window type AC complete all as specified and directed. Make: Air master /AUE/AE
S&F in replacement of unsv 4way reversing valve kit to maintain the desired temperature of cooling system of window type AC /split type AC of capacity 1.5/2 Ton as per site requirement including gas charging complete all as specified and directed.
S&F in replacement of unsv PCB circuit Hot & cold for window type AC complete all as specified and directed. Make- LG /Voltas
S&F in replacement of unsv condensing coil for window type AC of capacity upto 2 Ton including gas charging complete all as specified and directed.
S&F Copper pipe of dia 1/4 inch fixed in repair complete all as specified and directed.
S&F Copper pipe of dia 3/8 inch fixed in repair complete all as specified and directed.
S&F Copper pipe of dia 1/2 inch fixed in repair complete all as specified and directed.
Taking down defective split type AC of any capacity/make after disconnecting electric connections and transporting to workshop from site ,dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same with new compressor of existing make including gas charging and testing complete all as specified and directed.
Taking down defective indoor Unit for Split AC 1.5 / 2Ton and replacing the same with new for existing make of AC complete all as specified and directed.
Attending the received/recorded complaints lodged by occupent for the not functioning/breakdown of AC/Refrigerator/Deep freezer/water coolar/desert cooler any type including taking down and dismantling with complete address all alongwith nature of fault and stores required. The contractor will collect the complain from the concern JE and will attend the complain as per the address and make good the faulty appliance (i.e. AC window/split, refrigrator/deep freezer of any capacity and make and type) The parts required to replacement will be measured in S&F in respective items for payment complete all as specified and directed by Engineer-in-Charge. (Note:- (i) any accessories found unserviceable will be replaced and shall be paid under S&F under respective items of this Sch 'A' . (ii) The contractor shall depute necessary man power/Technician on required basis for rectifying the jobs including Sundays & holidays . (iii) Not deploying the sufficient manpower/Technican to attend the complaint on same day or just next day the recovery will be made @150 per complain/day after that.
S&F in replacement of PCB circuit hot and cold to split type AC 1.5 /2 ton for existing makes of AC complete all as specified and directed.
S&F in replacement of PCB circuit for INVERTER AC hot and cold for split type AC of capacity upto 2 Ton of existing makes of AC complete all as specified and directed.
S&F in replacement Blower Motor (ISI marked ) of split type AC upto 2 Ton capacity as per exisitng specification complete all as specified and directed.
S&F in replacement condensor fan Motor (ISI marked ) of split type AC upto 2 Ton capacity as per exisitng specification complete all as specified and directed.
S&F in replacement of UNSV Remote control with two AAA battery for split type AC of capacity 1.5 ton /2 ton suitable for make of LG/ Carrier/ Sidwal/ Whirlpool as per existing complete all as specified and directed.
S&F Insulation material for copper pipe outer covering 25mm thick fixed in repair complete all as specified and directed.
S&F in replacement condensing fan blade for split type AC of capacity upto 2 Ton as per exisitng size complete all as specified and directed.
S&F in replacement Blower for split type AC of capacity capacity upto 2 Ton complete all as specified and directed.
S&F PVC round sheathed copper conductor cable of size 2.5 Sqmm 3 core fixed in repair complete all as specified and directed. Make - Havells/ Plaza/ Polycab
Supply & charging Refrigerant R-22 to Air conditioner (window type /split type) of any capacity and make all as specified and directed. Make - Mafron
Supply & charging Refrigerant R-32 to Air conditioner (window type /split type) of any capacity and make all as specified and directed.
Supply & Charging Refrigerant R - 410 to Air conditioner (window type /split type )of any capacity and make complete all as specified and directed. Make :- Mafron
Supply, install & testing of voltage stabilizer of capacity 4 KVA naturally air cooled copper wounded after disconnecting the unsv voltage stabilizer from machine for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 270 V with stabized output of 230V accuracy +/-2.5% all as specified and directed, complete all as specified and directed. Make:-V Gaurd, Voltas, Bluebird, Microtek
S&F submersible water lifting pump single phase 18W, 230 V ,50 Hz with connection lead for desert cooler including taking down old unsv lifting pump complete all as specified and directed. Make : Khaitan/ Cool Home/Orison.
S&F in replacement of unsv Fan motor of desert cooler 1/7 HP with fan blade & frame legs single phase 230 V, 50 Hz incl fixing on desert coller with nuts bolts complete all as specified and directed. Make : Khaitan/ Cool Home/ AUE
S&F in replacement Rubber pipe 15mm dia (ISI marked) heavy grade for desert cooler complete all as specified and directed.
S&F in replacement unsv Wood wool pad of size 24" x 18" (set of 3) for desert cooler complete all as specified and directed.
S&F in replacement unsv 3way PVC water distributor with suitable size nuts bolts and PVC elbow for water connection of desert cooler complete all as specified and directed.
S&F in replacement Plug top three pin 16 Amps 3Pin complete all as specified and directed .Make :-Anchor/Havells/Plaza .
All as per Ser item No 67 here in before but for refrigerator of capacity from 200Ltrs to 320 Ltrs.
S&F in replacement Ball valve of size 15mm high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. Make: Prayag/ Seiko/ Jainko
S&F in replacement PVC connection of size 15mm x 450 mm superier quality fixed in repair complete all as specified and directed. Make: Prayag/ Jainko/ Pearl
S&F in replacement Stop valve of PTMT of size 15mm, any colour screwed for iron pipe (ISI marked) fixed in repair complete all as specified and directed. Make: Prayag/ Jainko/ Shakti
Removing of desert cooler from site after disconnecting the electric connection and water connection, transporting to workshop, taking out rusted bottom and replacing with new bottom as per existing size of PGI sheet and transporting back to site, installing at site including electric and water connections and testing complete all as specified and directed.
S&F in replacement unsv Side shutter of Desert cooler as per existing size of PGI sheet of desert cooler complete all as specified and directed.
S&F in replacement Capacitor 4 MFD, 440V (ISI Marked) fixed in repair all as specified and directed. Make-Epcos/Tibcon / Havells
S & Charging Refrigerant R 134 a/R-32 to Refrigerators of any capacity incl replacement of old filter and capillary copper tube as per existing size any length and make complete all as specified and directed.
S&F in replacement unsv Starting relay for water cooler No CAJ -2612 / CAJ -34 / AHR 13 complete all as specified and directed. Make: Hi-Tech/Sriram /Ranutrial
S&F in replacement unsv Starting capacitor of capacity 60/80 MFD, 80 / 100 MFD ,100/120 MFD (ISI Marked) 440V AC for water cooler complete all as specified and directed. Make-Epcos/Tibcon / Asian/ Havells
S&F in replacement unsv Over load protector of any size and capacity for water cooler as per existing size complete all as specified and directed. Make: Hi-Tech/Sri Ram./ Ranutrial
S&F in replacement unsv Thermostat switch of any size for water cooler complete all as specified and directed . Make: Denfos/Indofos/ Ranutrial
S&F in replacement unsv Condensing fan blade for water cooler of any size any capacity complete all as specified and directed. (As per sample) .
S&F in replacement unsv self closing push bib cock with wall flange heavy duty polished bright cast copper alloy chromium plated for water cooler of any size complte all as specified and directed. Make : Prayag .
S&F in replacement unsv Rubber pipe 1.25 inch dia for waste water of water cooler complete all as specified and directed. .
Removing of water cooler of capacity 60/120Ltrs from site after disconnecting electric & water connections and transporting to workshop, taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R134a of the same make/ company of existing water cooler including gas charging and testing for leakage and rectify the same if any including transporting back from workshop and installing at site complete all as specified and directed. Make - COPELAND/ VOLTAS / SHRI RAM/ SIDWAL
All as per ser item No 21 here in before but for split type INVERTER AC any capacity.
All as per Ser item No 61 here in before but for water cooler of capacity 40/80Ltrs.
S&F in replacement unsv Blower motor of capacity 1/35 HP for water cooler of capacity 40/80, 60/120 Ltrs complete all as specified and directed. Make : Air master / AUE
S&F in replacement unsv Blower motor of capacity 1/10 HP for water cooler of capacity 150 Ltrs complete all as specified and directed. Make :Air Master/AUE
Supply & Charging Refrigerant R 134 a/ R 22 /R-32 to Water Cooler of any capaciy including replacement old filter and capillary copper tube as per existing size any length and make complete all as specified and directed.
Removing refrigerator of capacity upto 195 ltrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new suitable comperessor of the same make/ company of refrigerator, gas charging with R-134a/R-32 and testing for leakage and rectify the same if any including transporting back from workshop and installing at site complete all as specified and directed. Make - LG/ VOLTAS / GODREJ
All as per Ser item No 61 here in before but for water cooler of capacity 150/150 Ltrs.
S&F in replacement unsv fan motor with fan suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.
S&F in replacement unsv PCB Circuit suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.
S&F in replacement unsv Bio Metal suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.
S&F in replacement unsv heater suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.
S&F in replacement unsv Thermostat switch for refrigerator complete all as specified and directed .Make:- Danfos/Indofos/Ranutrial
S&F in replacement Starting relay of refrigarator of any capacity complete all as specified and directed.
S&F Over load protector of refrigarator of any capacity fixed in repair complete all as specified and directed. Make:LG/Godrej/Hi-Tech
S&F in replacement of cooling coil of refrigerator as per existing size with gas refilling complete all as specified and directed. Make of refrigerator: Godrej/Voltas/LG/ Whirlpool.
S&F in replacement of condensing coil of refrigerator as per existing size with gas refilling complete all as specified and directed. Make of refrigerator: Godrej/Voltas/LG/ Whirlpool.
S&F in replacement PVC round sheathed copper conductor cable of size 1.5 Sqmm 3 core complete all as specified and directed. Make : PLAZA/Shalimar/Havells
S&F Thermostate switch for deep freezers of any capacity fixed in repair all as specified and directed.
Removing Deep Freezer of capacity upto 400 ltrs of make Voltas/Bluestar from site after disconnecting electric connection and transporting to workshop, taking out burnt compressor and replacing with new suitable comperessor of the same make/ company of deep freezer, gas charging with R-134a/R-32 and testing for leakage and rectify the same if any including transporting back from workshop and installing at site complete all as specified and directed.
S&F in replacement unsv Condensor fan motor for deep freezer of any capacity as per exiting size & make complete all as specified and directed . Make
of deep freezer: voltas /blue star
S&F in replacement vegitable tray for Refrigerator as per suitable size complete all as specified and directed.
S&F in replacement bulb for Refrigerator as per suitable size complete all as specified and directed.
S&F in replacement Plug top three pin 6 Amps 3Pin complete all as specified and directed. Make :Anchor/PLAZA/Havells.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
tender88.pdf
Tender Documents • 1.31 MB
BOQ_834557.xls
BOQ • 1.02 MB
Download all tender documents and submit your bid