Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹210.1 CrAdmitted-Finance B 163 SWARN JAYANTI PURAM GHAZIABAD GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | ₹210.1 Cr | Admitted-Finance |
| 2 | ₹220.8 CrAdmitted-Finance | ₹220.8 Cr | Admitted-Finance |
| 3 | ₹227.3 CrAdmitted-Finance C O VOLTAS LIMITED SPARE PARTS DEPOT OLD HUTMENT COLONY NCL NIGAHI SINGRAULI M P 486884 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486884 | ₹227.3 Cr | Admitted-Finance |
| Sl No | Description | Qty | Unit | CAPITAL ELECTECH PVT LTD | UNIVERSAL MEP PROJECTS & ENGINEERING SERVICES LIMITED | Vikran Engineering and Exim Pvt Ltd |
|---|---|---|---|---|---|---|
| 1.00Overhead 11 kV Line | ||||||
| 2.00 | 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) | 61,919 | Nos. | 28,69,23,977.34 ₹28.7 Cr | 30,42,25,384.32 ₹30.4 Cr | 29,44,49,612.6 ₹29.4 Cr |
| 3.00 | Foundation of PCC Supports as per scope of works, cement concreting (1:3:6) (0.268 Cmt for each support) | 61,919 | Nos. | 8,17,59,085.98 ₹8.2 Cr | 7,69,36,834.26 ₹7.7 Cr | 8,42,43,276.26 ₹8.4 Cr |
| 4.00 | Stone pad for supports as per scope of works & drawing (300x300x75 mm ) | 61,919 | Nos. | 54,06,767.08 ₹54.1 L | 40,40,214.75 ₹40.4 L | 55,52,895.92 ₹55.5 L |
| 5.00 | 11 KV V-Type Cross-arm (M.S Angel 65X65x6mm weight-10.37 kg) | 55,401 | Nos. | 8,07,35,877.3 ₹8.1 Cr | 8,80,64,321.58 ₹8.8 Cr | 8,28,27,819.06 ₹8.3 Cr |
| 6.00 | Cross arm holding back clamps (MS Flat-50x8 mm, weight-1.33 kg) with bolts and nuts | 55,401 | Nos. | 1,30,09,262.82 ₹1.3 Cr | 1,57,68,232.62 ₹1.6 Cr | 1,34,01,501.9 ₹1.3 Cr |
| 7.00 | F- Bracket MS flat (50x8 mm) (weight- 1.56 kg) with nut and bolts | 55,401 | Nos. | 1,81,08,370.86 ₹1.8 Cr | 1,63,17,256.53 ₹1.6 Cr | 1,81,08,370.86 ₹1.8 Cr |
| 8.00 | Cut point top channel (100x50x6 mm) of length 1150 mm along with supporting clamp and nut-bolts | 6,518 | Nos. | 1,13,75,343.96 ₹1.1 Cr | 1,17,26,859.7 ₹1.2 Cr | 1,16,75,302.32 ₹1.2 Cr |
| 9.00 | Bottom support channel for Cut point (100x50x6 mm) of length 230 mm along with supporting clamp and nut-bolts | 6,518 | Nos. | 44,68,610.44 ₹44.7 L | 60,09,921.9 ₹60.1 L | 47,83,951.28 ₹47.8 L |
| 10.00 | DP Top channel (100X50x6mm) 2240 mm long with supporting clamp and nuts-bolts | 3,258 | Nos. | 1,10,98,898.28 ₹1.1 Cr | 1,28,04,689.34 ₹1.3 Cr | 1,13,83,386.84 ₹1.1 Cr |
Tender Value
₹200.3 Cr
EMD Value
₹4.0 Cr
Closing Date
30 Sept 2024, 5:00 pmClosed
Superintending Engineer (RDSS)
MVVNL, 4-A, Gokhale Marg, Lucknow
FEEDER SEGREGATION OF BALANCE AGRICULTURE FEEDERS IN RAEBARELI, SITAPUR, UNNAO, BADAUN AND SHAHJAHANPUR DISTRICTS OF MVVNL, UTTAR PRADESH UNDER RDSS
2024_MVVNL_944647_3
RDSS/0024/24
Open Tender
Electrical Works
365 days
RAEBARELI, SITAPUR, UNNAO, BADAUN AND SHAHJAHANPUR
As per tender documents
2 documents required · 2 mandatory
₹29,500
EE To MD MVVNL A/c No 10101985738 IFSC SBIN0003347
₹4.0 Cr
3 Dec 2024
7 Sept 2024
1 Oct 2024
7 Sept 2024
30 Sept 2024
7 Sept 2024
Overhead 11 kV Line
8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
Foundation of PCC Supports as per scope of works, cement concreting (1:3:6) (0.268 Cmt for each support)
Stone pad for supports as per scope of works & drawing (300x300x75 mm )
11 KV V-Type Cross-arm (M.S Angel 65X65x6mm weight-10.37 kg)
Cross arm holding back clamps (MS Flat-50x8 mm, weight-1.33 kg) with bolts and nuts
F- Bracket MS flat (50x8 mm) (weight- 1.56 kg) with nut and bolts
Cut point top channel (100x50x6 mm) of length 1150 mm along with supporting clamp and nut-bolts
Bottom support channel for Cut point (100x50x6 mm) of length 230 mm along with supporting clamp and nut-bolts
DP Top channel (100X50x6mm) 2240 mm long with supporting clamp and nuts-bolts
Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts
Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts
Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts
Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts
11 KV polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings
Fish plate for jumpering
Phase wire 6/3.35 + 1/3.35 mm (50 sqmm Al. Area) ACSR Rabbit conductors
PG clamp for Rabbit conductor
Aluminium Jointing sleave for ACSR Rabbit
Aluminium binding wire and tape
11 KV Polymer Pin Insulators 5 KN with nuts
Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings.
8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
MS Danger board with Back calmps & nuts and bolts as per Technical specification
Anti-climbing device-1.5 kgs with supporting clamp, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS
Numbering and scheme details on each pole as per Technical specification and scope of work
Tree Cutting Compensation
Existing 11KV/LT line Crossings
13 Meter long Steel Tubular Poles with welded steel base plate of design 410 SP 72 (With coating of redoxide paint from manufacturer as per SBD)
11 Meter long Steel Tubular Pples with welded steel base plate of design 410 SP 55 (With coating of redoxide paint from manufacturer as per SBD)
Foundation of STP 13 M Supports as per scope of works, cement concreting (1:3:6) (0.63 Cu Mtr for each support)
Foundation of STP 11 M Supports as per scope of works, cement concreting (1:3:6) (0.44 Cu Mtr for each support)
Aluminium paint as per mentioned in SBD
Extention Supporting channel (100x50x6 mm) 3000 mm long for V-cross arm with holding back clamps and nut-bolts.
11 KV V-Type Cross-arm (M.S Angel 65X65x6mm, weight-10.37 kg) with holding back clamps (MS Flat-50x8 mm, weight-1.33 kg) and nut-bolts.
Guarding Cross arm (75x40x6 mm) 2210 mm long with eye bolts (16mm dia)
Back clamp for guarding cross arm (50x8 mm) (weight- 1.15 kg) with nut & bolts.
Cross arm holding clamps (MS Flat-50x8 mm) (weight-1.33 kg) with bolts and nuts
6 SWG GI wire along the span
8 SWG GI wire across the span
12 SWG GI wire for binding
11 KV Polymer Pin Insulators 5 KN with nuts
F-bracket MS flat (50X8 mm) (weight- 1.5 kg) for fitting top insulator with bolts & nuts
Barbed wire GI
Danger Plate with clamps & bolts
Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings.
8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
Supply & Installation of 11KV VCB Switchgear panel outgoing for outgoing feeders
11 KV VCB
11KV VCB Switchgear panel outgoing CTR 200/100/5A, 350 MVA
11 KV rearrangement for connecting new 11 KV VCB with existing 11 KV Switch gear (Adoptor Panel)
11 KV 3 core cable
Cable AL 3X185 sqmm XLPE 11 KV
Laying of 11 KV cable including cost of sand & bricks
11 KV cable jointing kit indoor 185 sq.mm.
11 KV cable jointing kit outdoor 185 sq.mm.
Control Cable
4x2.5 mm sq
2x2.5mm sq
Double pole structure at 33/11 Kv Sub Station boundary
11 Meter long Steel Tubular Poles with welded steel base plate of design 410 SP 55 for double pole structure (With coating of redoxide paint from manufacturer as per SBD)
Foundation of STP 11 M Supports as per scope of works, cement concreting (1:3:6) (0.5 Cmt for each support and 0.014 cmt for muffing)
DP Top channel (100X50x6mm) 2240 mm long with supporting clamp and nuts-bolts
Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts
Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts
Belting clamp-Top clamp (Flat-50x8 mm) (weight 1.4 kg) with bolts and nuts
Belting clamp-Bottom clamp (Flat-50x8 mm) (weight 1.5 kg) with bolts and nuts
Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings.
8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
MS Danger board with Back calmps & nuts and bolts as per Technical specification
Anti-climbing device-1.5 kgs with supporting clamp, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS
Numbering and scheme details on each pole as per Technical specification and scope of work
Controll Room Extension
Excavation in foundation in ordinary soil (Loam day or sand) including lift upto 1.5 mtr. And lead upto 30 m and including filling watering and ramming of excavated earth into the building and sides of the foundation trenches or in to the plinth and directed by the engineer-in-charge upto a distance of 30 m from the foundation
Concrete with 4 cm.gauge 1st class brick ballast (class 150) coarse sand (F.M.1.8 to 2.5) and cement in proportion of 10:5:1 in foundation and under floors including supply of all materials labour and T&P etc. required for propoer complrtion of work.
1st class brick work in 1:6 cement & coarse sand (F.M.1.8 to 2.5) morter in foundation & plinth including supply of all materials, labour and T&P etc. required for propoer complrtion of work.
1st class brick (class 150)work in 1:6 cement & coarse sand (FM 1.8 to 2.50) morter but in supper structure but for wall of one & half brick thick including supply of all materials , labour T&P etc required for propoer completion of work.
1st class brick (class 150) work in 1:6 cement & coarse sand (FM1.8 to 2.50) morter but in supper structure but for wall of one brick thick including supply of all material, labour T&P etc required for proper completion of work.
Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in over all rate) wrought to required shape as necessary I/C bending for proper completion of the work & I/C supply of steel its wastege shall be measured stee! shall not be supplied by the department.
Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks roof work gates etc. wrought to required form including holes riveting or welding where necessary and also including supply of steel bolts nuts wastage etc.and their fixing required for proper completion of the work (steel is not supplies by the department)
R.C.C. work with cement approved coarse sand (P.M. 1.8 to 2.5)and 2 Cm gauge graded approved hard stone ballast in proportion 1:2:4 in lintels of doors & windows excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 BWG G.I. binding wire and including necessary centring & shuttering etc. and also including cost of all materials, labour and T&P etc. required for proper completion of the work.
R.c.c. work with cement approved coarse sand (P.M. 1.8 to 2.5)and 2 Cm gauge graded approved hard stone ballast in proportion 1:1:5:3 for slab excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 BWG G.I binding wire and I/C necessary centering & shuttering etc. and also I/C cost of all materials, labour and T&P etc. required for proper completion of the work.
12 MM thick plaster with cement morter consisting of 1 aart: Sparts of approved coarse sand on fare surface "ncluding supply of all materials, labour T&P etc. required for proper completion of work.
Supply & fixing fan hooks 16 mm dia 200 mm long complete.
P/F glass strip of 40 mm depth in joints of floor and skirting at the time of laying, floors flush with floor level ncluding labour. Tools and plants etc. complete.
40 mm thick 1:2:4 floor without base concrete floor with cement, approved coarse sand &2 cm. graded approved stone ballast (shingle for bareily) laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and giving them a uniform finish including supply of all labour and T&P etc required for proper completion of work.
White washing three coats of new surface including cost of all materials, labour and T&P etc. required for proper completion of the work exept cost of angle iron and flat.
One priming coat and two coats of dry distemper castle or equivalent make on new surface including cost of all materials, labour and T&P etc. required for proper completion of the work.
Finishing walls with water proof cement paint of approved make and quality over new work with three coats to give an even shade including supply of all materials, labour and T&P etc.required for proper completion of the work.
Writing point for light with 1.5 sq.mm. FRPVC insulated multistrand single core copper conductor cable in surface conduit pipe, complete with copper earth continuity wire, piano type switch & ceiling rose/angle/button holder on 3mm thick phenolic aminated backelite-sheet etc. Complete in all respects, as directed including matching colour wash.
Wiring point for fan/fresh air fan (light duty exhaust fan) n PVC conduit with 1.5 sq.mm. FR PVC insulted multistrand copper condctor cable as earth wire drawn nside the conduit.
S/F Batten/Angle Holder of approved quality complete n all respect.
Painting or varnishing on new iron work in small areas or new wood work with one coat of ready mixed priming paint and two coats of approved superior quality ready mixed paint (Luxol) or equivalent brand or varnish I/C supply of all materials, labour T&P etc. required for proper completion of work.Paint to be used should conform I.S.103-1950
Dismantling brick work or stone work in time or cement mortar and including stacking of materials as directed by E/l within distance of 60mtr.
Dismantling Existing plaster including disposal of refuse as directed by E/l within a distance of 60 mtr.
Dismantling C.C brick or brick or granolithic floors including base concrete and including stacking of dismantled material as directed by E/l within a distance of 60 mtr.
Railway Crossing
11 KV under ground railway crossing by 2 nos (including one spare) 3CX185 sqmm XLPE Armoured Cable using 150mm dia GI pipes (grade A for underground laying and grade B for Pole support), with 11 KV XLPE Cable in G.I. Pipe on double pole with sutiable clapms, nut & bolts, Outdoor Heat Shrinkable cable jointing kits, Lugs, 4 nos GI 3-Meter long pipe, Erathing, 8 SWG GI wires, cable markers, Bi metalic clamps, Jumpering, as required as per technical specifications, Drawings and Scope of the work.
11 KV Line crossing on double pole (11 Meter long Steel Tubular Poles with welded steel base plate of design 410 SP 55) With coating of redoxide paint from manufacturer as per SBD
Foundation of STP 11 M Supports as per scope of works, cement concreting (1:3:6) (0.5 Cmt for each support and 0.014 cmt for muffing)
Aluminium paint as per mentioned in SBD
DP Top channel (100X50x6mm) 2240 mm long with supporting back clamps and nuts-bolts
Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts
Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts
Belting clamp- Top clamp (Flat-50X8 mm) (wieght 1.4 kg) with bolts and nuts
Belting clamp- Bottom clamp (Flat-50X8 mm) (wieght 1.5 kg) with bolts and nuts
Fish plate for jumpering
11 KV Polymer Pin Insulators 5 KN with nuts
9 KV, 10KA station class Lighting Arrester
Supply of 11 kV XLPE insulated Al. UG cable of size 3Cx185 mm2
Supply and Erection of Aluminium lugs-185 Sq.mm
Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
Hoisting of 3CX185 sqmm of 11 KV single cable on erected double pole including GI pipe 3 mtr long 6" dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. (all the materials shall be arranged by Bidders)
Earth digging minimum 3 meters below the Railway track by Horizontal Drilling (HDD) Method for laying, termination/jointing, erection of underground 11 KV grade 3-Core 185 Sqmm XLPE power cable in G.I. Pipes as per TS / approved drwaings.
Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 KV XLPE cables including cost of Bricks, sand, clamps etc.
G.I. Pipe (6" dia.) for for laying UG below the Railway track by HDD Method.
Supply and erection of 11 KV single core 95 sqmm XLPE Aluminium cable for jumpering
Testing and Commissioning of 11 KV grade 3-core 185 sqmm XLPE power underground cable
Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings.
8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
MS Danger board with Back calmps & nuts and bolts as per Technical specification
Anti-climbing device-1.5 kgs with supporting clamp, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS
Numbering and scheme details on each pole as per Technical specification and scope of work
11 KV Polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings
PG clamp for Rabbit conductor
Railway crossing documentation and approval fee etc. as per actual on submission on requiste documents of concern department.
National Highway Crossing
11 KV under ground National Highway crossing by 2 nos (including one spare) 3CX185 sqmm XLPE Armoured Cable using 150mm dia GI pipes (grade A for underground laying and grade B for Pole support), with 11 KV XLPE Cable in G.I. Pipe on double pole with sutiable clapms, nut & bolts, Outdoor Heat Shrinkable cable jointing kits, Lugs, Erathing, 8 SWG GI wires, cable markers, Bi metalic clamps, Jumpering, as required as per technical specifications, Drawings and Scope of the work.
11 Meter long Steel Tubular Poles with welded steel base plate of design 410 SP 55 for Double Pole Structure (With coating of redoxide paint from manufacturer as per SBD)
Foundation of STP 11 M Supports as per scope of works, cement concreting (1:3:6) (0.5 Cmt for each support & 0.014 cmt for muffing)
Aluminium paint as per mentioned in SBD
DP Top channel (100X50x6mm) 2240 mm long with supporting back clamp and nuts and bolts
Horizontal Belting Angle (Angle-50x50x6 mm) 2240 mm long with bolts and nuts
Cross bracing Angle (Angle-50x50x6 mm) 2500 mm long with bolts and nuts
Belting clamp- Top clamp (Flat-50X8 mm) (wieght 1.4 kg) with bolts and nuts
Belting clamp- Bottom clamp (Flat-50X8 mm) (wieght 1.5 kg) with bolts and nuts
Fish plate for jumpering
11 KV Polymer Pin Insulators 5 KN with nuts
9KV, 10KA station class Lighting Arrester
Supply of 11 kV XLPE insulated Al. UG cable of size 3Cx185 mm2
Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
Hoisting of 3CX185 sqmm of 11 KV single cable on erected double pole including GI pipe 3 mtr long 6" dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. (all the materials shall be arranged by Bidders)
Earth digging below the National Highway by Horizontal Drilling (HDD) Method for laying, termination/jointing, erection of underground 11 KV grade 3-Core 185 Sqmm XLPE power cable as per TS / approved drwaings
Digging of Trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 KV XLPE cables including cost of Bricks, sand, clamps etc.
Supply & Erection of Aluminium lugs-185 Sq.mm
Pipe HDPE having 160 mm dia for for laying UG below the National Highway by HDD Method.
Supply & erection of 11 KV single core 95 sqmm XLPE Aluminium cable for jumpering
Testing & Commissioning of 11 KV grade 3-core 185 sqmm XLPE power underground cable
Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings.
8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
MS Danger board with Back calmps & nuts and bolts as per Technical specification
Anti-climbing device-1.5 kgs with supporting clamp, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS
Numbering and scheme details on each pole as per Technical specification and scope of work
11 KV Polymer Disc insulator 45 KN (B&S type) along with suitable hardware fittings
PG clamp for Rabbit conductor
National Highway crossing documentation and approval fee etc. as per Actual
G.I. Pipe 6" dia. with Clamps
Road Restoration Charges etc. as per actual on submission on requiste documents of concern department.
Distribution transformers
9 M / 400 kgs WL PCC Poles (PCC Pole as per state practice)
Foundation of PCC Supports as per scope of works, cement concreting (1:3:6) (0.268 Cmt for each support)
Stone pad for supports as per scope of works & drawing (300x300x75 mm )
Transformer Top channel MS (100x50x6mm) 2800 mm long with supporting back clamps and nut-bolts
AB switch mounting channel (100x50x6mm) 2800 mm long with nuts & bolts
Back clamp for AB switch mounting channel(50x8mm)- (weight-1.8 kg) with nuts & bolts
DO fuse mounting channel (75x40x6mm) 2800 mm long with nuts & bolts
Back clamp for DO fuse mounting channel(50x8mm)- (weight-1.9 kg) with nuts & bolts
Tapping horizontal cross arm (100x50x6 mm) of length 1020 mm along with calmps (50x8) and nut and bolts
Tapping bottom channel (100x50x6 mm) of length 256 mm along with calmps(50x8) and nut and bolts
PG clamp for Rabbit conductor
Transformer mounting channel (100x50x6mm) 2800 mm with nuts & bolts
Transformer mounting channel support (50x50x6mm) 500 mm long with Nuts & bolts.
Transformer Belting angle (50x50x6mm) 2800 mm long with nuts & bolts
Transformer Belting angle support (35x35x6 mm) 500 mm long with nuts & bolts
11 KV polymer Disc insulator 45 KN (T&C type) along with suitable hardware fittings
11 KV Polymer Pin Insulators 5 KN with nuts
11/0.4 kV Distribution Transformer 25 KVA Three Phase aluminum wound DTR with high grade CRGO Core (Energy Efficiency Level-1 specified in IS 1180 (Part-1):2014 as per latest amendment 4 March 2021)
Tree Cutting Compensation
ACSR weasel counductor for Jumpering
Bimetallic connector for HT & LT side of the transformer
T clamp & PG clamp for jumpering
E Bracket MS flat (50X8mm) with nuts & bolts
LT Distribution box polyester sheet moulding compound (SMC) for 25 kVA Distribution transformer with arrangement of suitable bus-bars & MCCB's, DB with suitable Back clamp support (2 Nos) for LTDB ( 65x8 mm) as per scope of works of SBD
1Cx35 sqmm 1.1KV XLPE cable with suitable lugs and glands and cable ties
Suitable clamps for LT service cable support
9 kV, 5 KA distribution class LA
11 kV, 3-ph, 200 A, 3 Pin type Vertical Mounting type AB Switch along with Support Insulators, Base Channel, down Pipe, operating handle and support, etc. complete as per technical specifications, scope of works and approved drawings
11 kV, 3-ph, Drop Out fuse Set (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
GI Earthing pipe of 40 mm dia & 3000 mm long as per IS 1161
GI flat (25x3 mm)
Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings.
8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
MS Danger board with Back calmps & nuts and bolts as per Technical specification
Anti-climbing device-1.5 kgs, 2.5mm dia (12 SWG) galvanized barbed wire on each 11 kV support as per scope of works & TS
Numbering and scheme details on each pole as per Technical specification and scope of work
LT line
8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
Foundation of PCC Supports as per scope of works, cement concreting (1:3:6) (0.268 Cmt for each support)
Stone pad for supports as per scope of works & drawing (300x300x75 mm )
Aerial Bunched XLPE Cable 3X50 (Ph) + 1X35 ( Bare messenger cum neutral) + 1x16 (insulated Street lighting) sqmm
LT pole clamp (50x8mm) (2.56 kg) with Nut and bolts for laying of ABC
Dead end clamp with Eye hook
suspension clamp with Eye hook
PG clamp for (For line to line jumpering of bare messenger cum neutral wire of LT Aerial Bunched Cable (ABC) & energizing DB Neutral)
LT Insulation Piercing connectors type-II of 16-95 sqmm size for energizing distibution Kiosk/box (AB cable to Service cable)
Insulation Piercing connectors/Connector type-I (AB cable to AB cable)
2Cx25 sqmm XLPE aluminium conductor cable for single phase DB incomer
4Cx35 sqmm XLPE aluminium conductor cable for Three phase DB incomer
Single phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with calmps (40x3 mm) and nut & bolts
Three phase Glass Fiber Reinforced Polyester Sheet Moulding Compound (SMC) Pole top distribution box with calmps (40x3 mm) and nut & bolts
Earthing of poles using spike type 20 Ø G.I earthing Rod of 2500 mm as per approved drawings.
8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
Stay Set (Galvanised) with 50x8 mm stay clamps, guy insulator , anchor plate (200x200x6mm) , nut bolts, 1 Nos turn-buckle, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work including foundation of stay support in each stay set as per scope of works
Stay Rod 16x1800 mm complete as per Technical specification, scope of work and tender drawing
Stay Wire 7/10 SWG
Stay Clamp- (Flat-50x8 mm) (weight-1.5 kg)with bolts and nuts
Stay Guy insulator LT
Stay Guy insulator HT (11 KV)
Stay thimble
Hellically formed end fitting
Concreting of Stay Rod (0.2 cmt cement concreting in mixture (1:3:6)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid