Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹3.4 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹4.2 Cr+₹77.7 L (22.8%)Rejected-Finance 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹4.2 Cr+₹77.7 L (22.8%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹4.3 Cr+₹91.3 L (26.7%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹4.3 Cr+₹91.3 L (26.7%) | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹4.5 Cr+₹1.1 Cr (32.2%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹4.5 Cr+₹1.1 Cr (32.2%) | L4 | Rejected-Finance Being other than lowest |
| 5 | L5₹5.4 Cr+₹2.0 Cr (58.0%)Rejected-Finance NORTH SITE TROMBAY MUMBAI 400 085 | MUMBAI SUBURBAN | MAHARASHTRA | 400085 | ₹5.4 Cr+₹2.0 Cr (58.0%) | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹4.2 Cr
EMD Value
₹5.0 L
Closing Date
7 May 2021, 6:00 pmClosed
SR DDG AND CE
DGNP BUILDING,S B MARG, LION GATE , NAVAL DOCKYARD MUMBAI 400023
PROVN OF 07 NOs EOT CRANES AND AUGUMENTATION FACILITY TO AST(AUXILIARIES AND STEAM) DEPT BLDG NO P-187 AT NAVAL DOCKYARD MUMBAI
2021_MES_435147_1
8507_1
Open Tender
Civil Works
Item Rate
540 days
MUMBAI
REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
DGNP MUMBAI
₹5.0 L
Yes
15 Jun 2021
8 Apr 2021
14 May 2021
8 Apr 2021
7 May 2021
23 Apr 2021
Amount
SCHEDULE 'A' PART-I (Building Addition/ Alteration )
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Rrendering cement plaster 1:4, on external wall, 20 mm thick (in two coats 10mm + 10mm) with water proofing compound on second coat, on fair faces of brick work or concrete surfaces and finished even and smooth (without using extra cement) all as specified and directed. (Note : Water proofing compound will be measured and paid separately)
Supply only integral water proofing compound
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 even and smooth without using extra cement all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and all as specified and directed.
Demolition of un reinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed.
25 mm thick wearproof topping @ 8.27 Kg of hardener and 33.06 Kg of cement per square metre (incorporating an approved metallic hardener),laid on concrete floors and pavings,and finished even and smooth all as specified .(except metallic hardner) (Note : Metallic floor hardener will be measured and paid separately)
Supply only metallic floor hardener
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ in 100 mm thick concrete slab all as specified and directed
Forming contraction joints 100 mm deep x 10 mm wide, filled with sealing compound, Grade A all as specified and directed
Cutting out concrete blocks, slabs, brickwork (in alter nate course), forming toothings for and bonding new work in mortar into old work, including new materials entering old wall set in CM 1:6 PCC Type B1 1:2:4 (20 mm graded aggregate) all as specified and directed
Preparation of new or previously untreated steel surface of any description, not otherwise described over 10 cm width or girth and priming with one coat of red oxide zinc chrome primer and applying two coats of synthetic enamel paint to all as specified and directed.
Preparing plastered or unplastered old surfaces of ceiling and applying one coats of white washing all as specified and directed.
Demolition of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and directed.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed including 06 nos FI hold fasts per wooden door frame with tarring of hold fast and back of chowkats with bed block 1:2:4 PCC,all as specified and directed.
Second class hard wood rail and style plain, framed, panelled shutters 35 mm thick, with one panel rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneered on both faces. The size of the rail and stile as per IS : 1003 (part I), kiln seasoned and chemically pressure treated all as specified and directed .
Dismantling structural steel work including doors, windows, gates but excluding framed truss etc all as specified and directed .
MS rolled section of grade Fe 410-W ( Gde E-250 ) quality A as in main and cross beams hip and jack rafters, purlins where connected to common rafter and running rails guides for sliding doors fixed with cleats or other connecting plates as per Sketch 'B' and all as specified and directed.
Welded steel wire fabric exc 4Kg weight per Sqm fix to wood or steel members all as specified and directed .
Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed..
Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
12 mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination , fixed with screws to aluminium frame work all as specified and directed.
200 mm aluminium anodised, barrel tower bolts of extruded section and fixed all as specified and directed.
250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed.
150 mm extruded aluminium alloy handles, fabricated type, anodised all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor (overall length of the cover plate is 150 mm) all as specified and directed.
Virified ceramic light shade tiles 10 mm thick (square/ rectangular) of first quality, classified under group B1a of international standard of ceramic tiles ISO: 13006, polished, area of each tiles not exceeding 0.36 sqm over screed bed or bedding layer of cement mortar 1:4, 15 mm thick for laying floor finishes. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
Virified ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm over cement mortar backing coat in vertical surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
10 mm thick backing coat in cement mortar 1:4, to receive tiles in skirting and dado all as specified and directed .
Framed steel work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed.
1.25 mm thick steel rolling shutters, gear operated type with chain wheel and hand chain, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as specified and directed .
Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections Fe 410 -W (GdeE- 250) quality A, as per Sketch 'B' and all as specified and directed.
Mild steel rail stopper and welding with rail track at the positions all as specified and directed.
Motorized rolling shutters of size 5.6 mtr x 7 mtr made of GI laths of convex corrugation complete with one piece construction, side guides 6” x 1 “ made of 2 mm and bottom rail made of 2 mm with bracket made of 2 mm thick material, door suspension shaft with springs, locking arrangements on both sides (HASPS), electric motor of 230V/415V with suitable mechanism, direct drive option, provision of push button control with minimum 3 buttons, limit switch, provision for remote operation for shutter powered with rechargeable battery. One spare remote transmitter and two no.s of batteries along with chargers, painted with one coat of red oxide paint on MS part with 0.9 mm top cover. Shutter accompanied with motor and mechanical gear arrangement, arrangement for emergency mechanical operation in the event of equipment/ electricity failure shall be operated by an auxiliary chain wheel drive all as specified/ directed.
Preparing new surfaces of plastered or unplastered walls, priming plastered and other surfaces with alkali resistant priming paint and applying two coats of acrylic emulsion paint, exterior grade over a coat of primer all as specified/ directed.
Taking down aluminium sliding window frames exc 1.5 sq.m but not exc 4 sq.m each but with shutters all as specified and directed.
Exposing the existing loose / damaged RCC pilasters in the gallery by means of hand held electric chiesel hammers so as to expose the reinforcement as per the requirement etc, as directed the debris should be removed and carted away from the premises and disposed of as directed at the cost of the contractor, cleaning the exposed RCC elements like columns / beam / slabs surface using water jet, wire brush removing rust scales from the old reinforcement rods and allowing to dry all as specified and directed.
Applying primer on the exposed reinforcement rods as per manufacturers specifications etc including necessary scaffolding/working platform as per site requirement complete all as specified and as directed .
Epoxy resin concrete bonding agent of make as specified for old and new concrete at the rate of 2.6 sqm per litre complete all as per manufacture's instruction all as specified and directed.
Free flowing, non-shrink, high strength M-50 grade micro concrete for lintel beam / various openings of window/ gate all as specified & directed by Engineer- in-Charge.
6 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600 mm grid with anodised aluminium snap grid frame work of size 605 mm x 605 mm for false ceiling and hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long using complete all as specified
Taking down chowkats or frames ( withouttaking off shutters from the frame) exc 1.5 sq.m but n. exc 4 sqm each all as specified and directed.
100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as specified and directed.
75mm thick cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate in floor etc finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Brushing neat cement slurry with 3.0 kg of cement per sq meter all as specified and directed.
Sheet glass 4 mm thick, ordinary quality and glazing with oil putty / rubber gasket, in square exc 0.5 sq.m in each pane all as specified and directed.
Alumimium grill powder coated of DG 103 with frame fixed to aluminium windows including all necessary fixing arrangements and all as specified and directed.
Aluminium powder coated sliding windows with 4 mm thick glass sheet (ordinary quality and glazing with rubber gasket in square exc 0.5 sq.m in each pane including taking down old glass panes) including shutters, window frame, handles, cleat rubber packing aluminium beading, screws, locking arrangement etc complete all as specified and directed.
Preparing new plastered or unplatered surface of walls and applying 2 coats of oil bound distemper over 3mm wall care putty complete all as specified and directed.
75 mm thick Cement concrete 1:2:4 , type B-1,using 20 mm graded stone aggregate in floor etc complete all as specified and directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed.
RCC type B0 1:2:4 (12.5 mm graded aggregate) for beams, cantilevers, bressummers, lintels over 1.5 m span all as specified and directed.
Aluminium powder coated window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
Preparing new plastered or unplatered surface of walls priming plastered surface with alkali resistant primimg paint and applyingtwo coats of acrylic emulsionpaint ,exterior grade all as specified and directed.
Material and Labour for preparation of old painted steel surface of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint all as specified and directed.
Total amount of Sch 'A' Part I C/o to Grand Summary on Ser Page No. 62
SCHEDULE 'A' PART-II (Internal Electrification)
Point wiring for one 6 Amps socket outlet point on same board, controlled by one switch with other switches, 1100 Volt grade single core confirming to IS 694 (1990) PVC insulated unsheathed 1.5 Sq mm multi stranded copper conductor cable (FRLSH) for phase and neutral, ISI marked with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated-unsheathed with proper color coding of Phase, Neutral & Earth, including all fittings and accessories complete all as specified and as directed by Engineer in Charge.
Point wiring for one light point controlled by one switch with 1100 Volt grade single core confirming to IS 694 (1990) PVC insulated unsheathed 1.5 Sq mm multi stranded copper conductor cable (FRLSH) ISI marked with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated-unsheathed, drawn in and including surface Stove enamelled steel conduit medium grade with fitting (ISI) marked ) not less than 20 mm dia,{ color coding of wires shall be for Phase , neutral and earth wire all as specified } sunken MS/ pressed steel boxes painted with black bituminous paint outside and two coat of aluminum paint inside for housing switches, socket, fan regulator etc.’ covered with 2.8 mm thick hylem laminated sheet ( ISI Marked ) with screws, including making good disturbed surfaces of wall/ ceiling/floor complete all as specified and as directed . Note:Cost of cutting /leaving forming chases for conduits,sinking for boxes and making good shall deemed to be included in quoted rate.
All as mentioned in item No 2.02 here in above but for one fan /exhaust fan/wall fan point controlled by one switch.
Point wiring for one 16 Amps socket outlet point on independent board , controlled by one switch with 1100 Volt grade single core confirming to IS 694 (1990) PVC insulated unsheathed 2.5 Sq mm multi stranded copper conductor cable (FRLSH) for phase and neutral, ISI marked with continuous earth wire of 2.5 Sqmm stranded copper conductor cable (FRLSH) ISI marked PVC insulated-unsheathed with proper colour coding of Phase, Neutral & Earth, drawn in and including surface Stove enameled steel conduit medium grade with fitting (ISI) marked not less than 20 mm dia with concealed sunken MS/ pressed steel boxes thickness not less than 1.6 mm painted with black bituminous paint from outside and two coat of aluminum paint inside for housing switches, socket, fan regulator etc’ covered with 2.8 mm thick white laminated Bakelite sheet ( ISI Marked ) complete all as specified and as directed.
Switch piano, flush type, single pole, one way 5 amps,230 volts, ISI marked complete all as specified and directed by Engineer in Charge.
Socket outlet 2 in 1, 2 & 3 pin 6 Amps, flush type. 230 volts complete all as specified and directed by Engineer in Charge.
Switch socket combination 3 pin 15/06 amps flush type, ISI marked complete all as specified and directed by Engineer in Charge.
Ceiling rose, 3 terminal polycarbonate, isolated body complete all as specified and directed ..
MCB SP 6-32 Amps, 240 volts AC , "C" curve ,10 KA,50Hz, ISI marked complete all as specified and as directed.
Ceiling fan five star rating with double ball bearing, 350 rpm, 1200 mm sweep 140-285 Volts AC, 50 Hz, p.f 0.99 with super energy efficient BLDC motor & power consumption shall not be more than 32W under standard test condition along with down rod, canopy and all accessories, along with smart remote controlled all as supplied by manufacturer and making necessary electrical connection with 3 core flexible copper conductor 1100 volts grade of suitable size ( not less than 1.5 Sq mm ) and length including and making necessary electric connection etc. all as specified and as dircted. Note : Contractor shall submit the guarantee from manufacturer for ceiling fan for minimum 03 years for any defects developed during the period.
Taking down copper/aluminium point wiring (light, fan , socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed by Engineer in Charge.
Taking down LT UG Cable 25sq mm 4 core including all as apecified and directed by Engr In Charge.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X 6 mm GI strip as earth lead by means of brass nuts and bolt,thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm ,15 mm thick plaster in CM 1:4,funnel with wire mesh ,RCC pit cover of 320 x 320 x 80 mm size (1:2:4) Type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all as shown in electrical plate No 3 of MES SSR Part -1 (2009) and specified including and provision of GI strip
upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade ,including all excavation and earth work and connecting the earthing strip to an earthing test point/panel including testing on completion complete all as specified and directed. by Engr-In-Charge.Note: (1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover. (2) Cost of additional GI strip more than 7.5 meter will be measured and paid seperately under relevant item
Exhaust fan,450 mm Sweep ,1400 RPM ,single phase, 230 volts AC,50 Hz with louver including cutting 450 mm hole through wall and making good disturbed surface, including PVC insulated three core flexible copper conductor 1.5 sq mm drawn through flexible pipe connecting with ceiling rose all as specified and as directed
Wall fan, 600 mm sweep ,single phase, 230 volts AC,50 Hz,oscillating type including PVC insulated three core flexible copper conductor 1.5 sq mm drawn through flexible pipe connecting with ceiling rose all as specified and as directed .
LED highbay luminaire, 150 Watt,230 volts, Make: Bajaj, Cat Part No : BGHBM 150W LED XE or equivalent make of Philips/Crompton all as specified and as directed by Engineer in Charge.
LED light fitting luminaire,40 Watt,230 volts, Make: Bajaj, Cat Part No : BIPC40W LED XE or equivalent make of Philips/Crompton all as specified and as directed by Engineer in Charge.
Surface rigid non- metallic PVC conduit 25 mm dia including tees, bends, elbows, reducers , bell mouth tebe ends and fixing accessories such as couplers , lock nuts, saddle , pipe , hooks for LAN & telephone all as specified and as directed by Engineer in Charge.
Rigid non- metallic PVC junction box 25 mm size suitable for telephone / LAN all as specified and as directed by Engineer in Charge.
Point wiring complete as specified with 1100 Volts grade 1.5 sqmm single core, PVC insulated, multi stranded copper conductor, FRLSH,drawn through in and including rigid steel conduit,stove enameled of suitable size with all accessories on wall/ceiling/floor/roof surface including cutting of wall etc and finishing with existing surface, sunk pressed steel or cast iron terminal boxes 16 SWG thick with 3mm thick Bakelite sheet top cover complete as specified with 1.5 sqmm multi stranded PVC insulated copper conductor, FRLSH as earth continuity conductor for one switch socket outlet,5 amps on independent board complete all as specified and directed by Engineer - In - Charge.
Sheet metal enclosures for DBs when MCBs to be used, Single pole and neutral 8 way with 200 Amps rated bus bar, 240 Volts double door , including necessary fixing arrangement such as clamp nut bolt etc all as specified and directed by Engr-In-Charge.
Sheet metal enclosures for DBs when MCBs to be used, Single pole and neutral 6 way with 200 Amps rated bus bar, 240 Volts double door , including necessary fixing arrangement such as clamp nut bolt etc all as specified and directed by Engr-In-Charge.
Sheet metal enclosures for DBs when MCBs to be used, Single pole and neutral 4 way with 200 Amps rated bus bar, 240 Volts double door , including necessary fixing arrangement such nut bolt etc all as specified and directed by Engr-In-Charge
MCB SPN, 6-32 Amps 240 volts AC , ,"C" curve,10 KA,50 Hz, ISI marked all as specified and as directed by Engineer in Charge. .
MCB SPN, 40 Amps, 230 Volts AC, 50 Hz, breaking capacity 10 KA, ISI marked all as specified and as directed by Engineer in Charge.
LT panel board, CPRI approved, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLS cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for grouting, PCC foundation etc with and including following :- (Main LT Panel)
BUSBAR CHAMBER: Busbar should be electrically grade Copper shrouded as fixed on insulators and of capacity equal to 1.5 times of rated incoming control
OUTGOING: (a) MCCB 63 Amp, 10 KA 4 pole,thermal magnetic release, adjustable overload setting 0.8 to 1.0,adjustable short circuit setting 6-10,quantity - 07 No ( outgoing for 06 No lathe Machine and 01 No spare ) (b) MCCB 40 Amp, 10 KA 4 pole,thermal magnetic release, adjustable overload setting 0.8 to 1.0,adjustable short circuit setting 6-10,quantity - 05 No ( outgoing for 04 lathe m/c and 01 No EOT crane of vikramaditya bay) (c) MCCB 20 Amp, 10 KA 4 pole,thermal magnetic release, adjustable overload setting 0.8 to 1.0,adjustable short circuit setting 6-10,quantity - 05 No ( outgoing rolling shutter 02 No & battery charger 3 phase 03 No.)
Notes: 1. All MCCBs shall have spreader link, phase separator and adjustable rotary handle and MCB shall be of 'C' Series. 2. Panel manufacturers should have in house powder coating plant with minimum 8 tanks pre-treatment of MS sheet facilities, dust free spray paint booth. 3. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel. 4. The panel manufacturer should have following certification: (i) CPRI certification, Degree of protection IP-54 (should have IEC:60439-1 & IEC:60529 tests). (ii) CPRI certification short circuit withstand strength should be 50 KA rms for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 6000 A with rated insulation voltage 660v. (iv) All the electrical switch gear like MCCBs, MCBs shall be of same make. (v) Drawing of LT panel board shall be got approved from GE before fabrication. (vi) LT panel board shall be compartmentalized in accordance to form 4b of IEC 61439 1-2
Supply & Lay Cable XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm,3.5 Core with terminating lugs all as specified and directed by Engineer in Charge.
Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with multistrand aluminium conductor of size 6 Sqmm 4 core( for lathe machine 32A) laid on walls/floor/trenches complete all as specified and as directed.
Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with multistrand aluminium conductor of size 10 Sqmm 4 core (for lathe machine 63A) laid on walls/floor/trenches complete all as specified and as directed.
Telephone socket outlet, modular socket on the modular plate & metal box including connections and modular plate etc as required complete all as specified and directed .
Multicore telephone cable conductor size 0.50 mm, two pair telephone wire, bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect and as directed by the Engr-in-charge.
Modular socket on the modular plate & plastic surface box including connections and modular plate etc as required. PCB based information Outlet (I/O) RJ45, category - 6, termination of category-6 UTP cable, shall support network line speed upto 1 Gbps, shall have RJ-45 type connector complete all as specified and directed by Engineer in charge.
One run of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required complete all as specified and directed.
Taking down ceiling fan, cable end, dismantling blades and removing fan and blades and handing over to user all as specified and as directed .
Sub main wiring with two runs of 4 sqmm nominal area with 1100 Volt grade confirming to IS 694 (1990) PVC insulated unsheathed with one run of 4 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including heavy duty PVC conduit not less than 20 mm dia medium grade with fitting (ISI) marked including cutting, chasing, for conduit and making good of walls etc complete all as specified and as directed . Note : Two runs of cable and one run of earth cable in PVC conduit shall be measured as one length.
All as mentioned in item No 2.40 here in above but two runs of 6 sq mm alongwith one run of 6 sq mm as earth wire complete all as specified and directed.
Sheet metal enclosure for provision and including of 63 A three pin and earth plug with socket complete with one triple pole MCB 63 A . 415 Volts, 50 Hz,10 KA,'C' series and ISI marked complete all as specified and as directed .
Sheet metal enclosure for provision and including of 32 A three pin and earth plug with socket complete with one triple pole MCB 32 A 415 Volts, 50 Hz,10 KA,'C' series and ISI marked complete all as specified and as directed .
Sheet metal enclosure for provision and including of 20 A three pin and earth plug with socket complete with one triple pole MCB 20 A 415 Volts, 50 Hz,10 KA,'C' series and ISI marked complete complete all as specified and as directed by Engineer in Charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 32x6 mm galvanised iron strip complete all as specified and directed by Engineer in Charge.
Total amount of Sch 'A' Part II C/o to Grand Summary on Ser Page No. 62
SCHEDULE 'A' PART-III ( LP AIR SUPPLY )
Galvanized iron pipe "Heavy duty including all fittings of size 65 mm dia laid in trenches/duct/floor all specified and directed.
All as mentioned in item No 3.01 here in before but size of 40 mm bore dia.
All as mentioned in item No 3.01 here in before but size of 15 mm bore dia
Gate valve,forged,Brass micro finish of size 65 m dia,flanged ends confirming to IS 3658 all as specified and directed
Gate valve,forged,Brass micro finish of size 50 m dia,flanged ends confirming to IS 3658 all as specified and directed.
Gate valve,forged,Brass micro finish of size 25 m dia,flanged ends confirming to IS 3658 all as specified and directed.
Gate valve,forged,Brass micro finish of size 15 m dia, screwed end confirming to IS 3658 all as specified and directed.
MS work Joist,channel,angle,or tee sections,fixed independently,without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated of Fe 410-W,Gde E-250),quality A all as specified and as directed.
Taking up/down existing GI pipe line 15 mm dia with all fittings and accessories such as valve,GI fittings,joists,channel,angle etc and kept at site complete all as specified and directed.
All as mentioned in item No 3.09 here in before but of size 40 mm dia all as specified and directed.
.All as mentioned in item No3.09 here in before but of size 65 mm dia all as specified and directed.
Material and labour for Anti corrosive and anti marine growth painting with two coat over a coat of primer on surface of GI pipe of size 15/40/65 mm bore dia including necessary preperation all as specified and directed.
Total amount of Sch 'A' Part III C/o to Grand Summary on Ser Page No. 62
SCHEDULE 'A' PART-IV (EOT CRANE )
Taking down EOT crane of 05 ton capacity from mounting including all connected accessories, power supply DBs etc with manual or mechanical power and without causing hindrance to existing system at site and stacking at a place inside naval dockyard (within 3km radius) for handing over to user all as specified and as directed.
Factory made indoor type wall mounted cubicle enclosure fabricated out of 2 mm thick CRCA sheet with weather proof powder coating suitable for and including MCCB 40 Amps,4 pole,16 KA,50 Hz, totally enclosed with all accessories such cable alleys,cable lugs/thimbles,nut,bolt etc all as specified and directed .
Indoor type double girder EOT crane, 05 ton safe working capacity, Long Travel - 30 metre for 01 crane, 42 metre for 01 crane & 60 metre for 05 cranes , span 11 meter and Main Hoist lift height 6 meter, operation through Radio Remote Control Pendant push Button type (RRC PB) design standard - IS: 3177 -1999, IS:807 2006 other relevant standards, duty of crane : Class III M 7, shrouded / M S angle type Down Shop Lead (DSL),Civil / grouting work, cable from Power Distribution Box (PDB) to DSL,cable tray, isolator switch, power supply : 415 V AC,50 Hz. complete all as specified and directed. Note : MS rail shall be measured and paid seperately under respective Item of Sch 'A' Part I Note: (i) Contractor is required to measure necessary dimensions i.e span , long travel, height of lift, clearance between rail center to the existing column at site before starting of the crane design/manufacturing. (ii) Dismantling/Erection of cranes shall be carried in consultation with user dept without causing hindrance to the existing sytem at site. (iii) Any items/additional acessories required for safely operation of the crane shall be deemed to be included in the quoted rate.
LT cable XLPE insulated PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor of size 4 core 16 sqmm using suitable GI saddles & clamps for fixing the cable on wall surface/through ducts and connected to existing panel aa as directed and specified.
Total amount of Sch 'A' Part IV C/o to Grand Summary on Ser Page No. 62
Garima Construction Co
SOOD ASSOCIATES PVT LTD
Idustrial products India
RENJIN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .