The tenderer must have minimum average annual contractual turnover of V/N or 'V' which ever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years,ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange,incorporated /registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
23 conditions · 13 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Covering letter duly filled by the tenderer to be submitted on their letter head as per Section 4.2 Part-I of STD-2022
A copy of Authorization/Power of Attorney issued by the sole proprietor/partnership firm/LLP/ Society/JV/Company in favour of the individual to sign the tender on behalf of the sole proprietor/partnership firm/LLP/ Society/JV/company as per Annexure Section 4.4 of STD-2022 Part-I. In case of company power of attorney must be backed by the resolution of Board of Directors and create liability against the company.
Details of Plant and Machinery already available with the firm must be uploaded as per Annexure-IX of STD-2022
List of engineers/personnel already available/ proposed to be employed for deployment on this work must be uploaded as per Annexure-X of STD-2022
Details of Beneficiary for Electronic Transfer of Funds must be uploaded as per Annexure-XII of STD-2022
An undertaking by sole proprietor firm/all partners of the partnership firm/Power of attorney holder if company (as per Annexure-B/C uploaded with STD-2022)or LLP or Society/JV that he/they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 (Part-II) of the General Conditions of Contract (as per Annexure- B/C uploaded with STD-2022). (Detail instructions/condition may be seen on Tender Document)
Please submit the copy of the registration certificate of firm, PAN, GSTIN (if applicable)etc.
Tenderes are compulsorily required to upload undertaking (attached as Annexure-A uploaded with STD-2022) regarding Employment /Partnership of Retired Railway Employees attached as Annexure'A'. Otherwise the tenderer will give full information as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender. Note:- Tenders without undertaking or required information shall be summarily REJECTED.
The tenderer shall clearly specify whether the tender is submitted on his own or on behalf of a partnership firm/Company/Joint Venture (JV) /Registered Society/ Registered Trust/HUF etc. The Tenderer (s) who is/ are constituents of firm, company, Association or Society shall enclose self-attested copies of the constitution of their concern, Partnership Deed, copy of PAN Card and Power of Attorney along with their tender. Tender Documents in such cases shall to be signed by such persons as may be legally competent to sign them on behalf of the firm, Company, Association, Trust or Society, as the case may be. Following documents shall be submitted by the tenderer: (a)Sole proprietor Firm: (i) Affidavit of sole proprietorship firm. (ii) All documents in terms of explanatory notes in clause 3.5 PART-I of STD-2022 (b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of explanatory notes in clause 3.5 PART-I of STD-2022. (c) Partnership firm, as per Tender Form-2 (Annexure-I) Para 18.10 PART-I of STD-2022: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) All other documents in terms of TENDER FORM -2 of STD-2022 (d) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association)/AOA (Articles of Association) of the company. (ii) A copy of Certificate of Incorporation. (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms of explanatory notes in clause 3.5 PART-I of STD2022 (e) Limited Liability Society: (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation of LLP. (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender/MoU/JV on behalf of the LLP and create liability against the LLP. (iv) All other documents in terms of explanatory notes in clause 3.5 PART-I of STD2022 (f) Registered Society & Registered Trust: (i) A copy of the Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society. (v) All other documents in terms of explanatory notes in clause 3.5 PART-I of STD-2022 (g) Joint Venture: All documents as specified under Para 3.7.7 PART-I of STD-2022
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suomoto post tender letters of the tenders shall be treated as NULL & Void as per Para 4.6 of STD- 2022
This tender will govern under "Indian Railway Standard General Condition of contract - 2022 or latest. Tenderers are requested to read GCC and tender document very carefully before submitting their Bid.
Performance Guarantee- The successful bidder shall submit PG as per procedure Mentioned in clause 5.1A of Northern Railway standard Tender Document 2022, The successful bidder shall submit the performance Guarantee(PG) amounting to 5% of the contract value
The tenderer shall submit along with the tender document, documents in support of his/their claim to fulfill the eligibility criteria as mentioned in the tender document. Each page of the copy of documents/certificates in support of credentials, submitted by the tenderer, shall be self-attested/digitally signed by the tenderer or authorized representative of the tendering firm. Self attestation shall include signature, stamp and date (on each page). Only those documents which are declared explicitly by the tenderer as "documents supporting the claim of qualifying the laid down eligibility criteria", will be considered for evaluating his/their tender
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
Undertakings by Partnership Firm- In case the Letter of Acceptance (LOA) is issued to a partnership firm, the undertakings as per clause 18.10 of Annexure -VIII of Northern Railway Standard Tender Document 2022 shall be furnished by all the partners through a notarized affidavit, before signing of contract agreement.
As per Railway board letter No. 2018/CE-1/CT/4 dt. 17.10.2018 contractor shall mandatorily update the labour data on Railway Sharmik kalyan portal on monthly basis. The detailed guidelines are given in Clause 5.4 of PART-I of Standard Tender Document- 2022.
Provision of SSDAC/MSDAC in lieu of overaged Universal axle counters in CH-BE section of Moradabad Division.
05-SNTRT-Sig-SSDAC-MSDAC2~NR
05-SNTRT-Sig-SSDAC-MSDAC2
Open
Works - General
12 Months
Moradabad, Uttar Pradesh
₹0
₹2.2 L
8 Jan 2026
16 Dec 2025
25 Dec 2025
105 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,45,52,199.59 | ||
| — | 2.00 | — | — | ||
| Installation and commissioning of SSDAC complete as per RDSO specification RDSO/SPN/177/2012(ver3) or latest The axle counter will be SSDAC section type with 2 or more detection point and it is possible to install without trolley protection track circuit. Installation to be done by OEM authorised Engineer as per the installation manual of the OEM. This include supply and installation of HDPE Pipe, GI pipe, shielded cable/wires masonry & wood work in location box, relay room, ASM Room it also include of fixing of resetting box in ASM office with all wooden and masonry work. Work to be done as per TAN STS/E/TAN/7010 or latest. Inspection: Consignee | — | — | — | 1,08,517.66 | |
| — | 8.00 | — | — | ||
| Installation, wiring, testing and commissioning of one Multi Section Digital Axle Counters Indoors Set comprising of processors/central evaluators for section/station/Relay Hut including its associated Indoor Equipment and wiring of the same to integrate with existing EI/PI/Local Signalling circuits. Work to be done as per TAN STS/E/TAN/7010 or latest Inspection: Consignee | — | — | — | 94,400 | |
| — | 48.00 | — | — | ||
| Installation and commissioning of Detection point Installation of complete assembly of Track device unit for entry or exit and track side electronic equipment (if applicable) along with Earthing (as detailed in special conditions) with all materials including drilling of required size holes on rails( if required) for fixing the track devices, taking the cable lead through anti rodent, anti- oxidant and non-flammable propagating type DWC pipe as per IS 14930 Part I or II or latest from track device to location box/mushroom and terminating it on terminals including digging of trench under track up to location/track side unit. (All material required for installation of above equipment are to be supplied by the firm.) Work to be done as per TAN STS/E/TAN/7010 or latest Inspection: Consignee | — | — | — | 6,79,680 | |
| — | 40.00 | — | — | ||
| Concreting unscheduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. It also includes the excavation of earth as required at site and as per instruction of site incharge. The volume in cubic meters shall include the volume occupied by any CI foundation, trstle, MS angle or flat or GI pipe required to be embedded in the casting, Cement coarse sand and aggregate 25mm are to be supplied by the contractor Inspection: Consignee | — | — | — | 1,07,093.28 | |
| — | 300.00 | — | — | ||
| Supply of G.I. pipe 50mm dia and fixing on wall tunnel/culverts/ bridges(suitably concreted at both ends) as per specification, drawing No: NR/S&T/CON/1.4/97 & instruction of Railway Engineer at site. Clamps of M.S. flats bolts and nut, to be supplied by the contractor and pipes should be fixed by clamps at average 1 meter intervals (Inspection by Consignee) | — | — | — | 52,171.8 | |
| — | 3500.00 | — | — | ||
| Supply of terminal block M-6 (ARA terminal-25mm) as per IRS:S75/2006(REV.2) and Drg.SA- 23741A,SA23745,SA-23746,SA23748,SA23756. or latest. This material will be procured by RDSO approved firm. inspected by RDSO | — | — | — | 2,57,092.5 | |
| — | 3000.00 | — | — | ||
| Termination of all the cores of all type of outdoor cable after its laying on both end. This also includes preparation of test report for core to core & core to earth on prescribed Performa for each core of the cable separately. This also includes dressing & lacing of cables on both ends. Performa for testing & material for lacing to be supplied by the contractor Inspection by Consignee | — | — | — | 34,926 | |
| — | 1600.00 | — | — | ||
| Boring & Trenchless cabling along with supply & insertion of self-lubricated HDPE pipe as per IS 4984:2016 of 110 mm outer dia with 6mm wall thickness in the bore for laying of Signalling / Telecom /Power cable under track/road/culvert at the depth of 1.5mtrs etc. cable laying covered separately. Inspection: Consignee | — | — | — | 23,15,441.6 | |
| — | 38000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per drg. No. (NR/S&T/CON/1. 1/97) and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to railways Inspection by Consignee | — | — | — | 2,80,668 | |
| — | 16000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.(NR/S&T/CON/1. 1/97-A) so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable route plan in all type of soil, It also includes clearance of routes of trees & bushes. Inspection by Consignee | — | — | — | 13,01,760 | |
| — | 128000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/CON/1.1/97) as per instructions of the site Engineer. Inspection by Consignee. | — | — | — | 9,46,688 | |
| — | 500.00 | — | — | ||
| Excavating & refilling of trench 0.3 Mts wide & 0.8 Mts deep on pitched/Stone/bricks paved surface, road crossing/platform etc. and restoring the surface to its original conditions Inspection by Consignee | — | — | — | 48,099 | |
| — | 8.00 | — | — | ||
| Supply of single app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. sketch no.RE/S&T/ALD/SK/219/82 and 221/82 with Alt.B. Inspection by Consignee | — | — | — | 1,67,593.92 | |
| — | 32.00 | — | — | ||
| Supply of Half app. case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. sketch no. RE/S&T/ALD/SK/220/82 with Alteration 'A' and 221/82 with alteration 'B'. Inspection by consignee. | — | — | — | 4,60,689.73 | |
| — | 8.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Cases (Single) as per drg. No. DRG NO NR/S&T/D&D/02/2024. All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor App. Case single will be supplied by railway. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. Inspection by consignee | — | — | — | 37,330.87 | |
| — | 32.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Cases (Half) as per drg. No.(NR/S&T/CON/2.7/97). All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. App. Case single will be supplied by railways. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination Inspection by consignee | — | — | — | 1,28,586.27 | |
| — | 8.00 | — | — | ||
| Preparation & fixing of bakelite hylum sheet 910x800x6 mm and bakelite shelf 900x450x25 mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts. Fixing of fuses, ARA terminal, plug in type Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the wood plank & all cable entry point on location boxes, location huts. JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Description for terminal drawing of circuits, inside app. Case. painting from outside as will inside with red oxide and aluminium paint is covered separately. Size of lettering will be 100 mm or as per instructions of Engineer at site. All material including bakelite shilf, hylum board, wood plank, angle iron square bar, wire and wiring material as per the IRS specn. nuts and bolts and other items shall be supplied by the contractor . Relays. ARA terminals & fuse only shall be supplied by the railway. (i)App. case single not involving wiring of relays.. Inspecton by Consignee | — | — | — | 35,938.1 | |
| — | 32.00 | — | — | ||
| Provision, preparation & fixing of Bakelite hylum sheet 450 x 600 x 6 mm. Hylum board shall be fixed on angle iron frame of 25 mm x 25 mm x 3 mm. Angle iron frame will be fixed in location box secured by nuts & bolts. This includes fixing of fuses, ARA terminals fixing & jamming of cable with 2 inches salwood plank provided at the bottom. i) This includes opening, passing & jamming armour of each cable in the hole drilled separately for each cable through salwood plank & all cable entering points on location boxes, location huts, JBs, relay room/battery room to be closed with suitable masonry works covered with sand and plastering, wiring description of terminals, drawing of circuits inside app. case. Painting from inside as well as outside with red oxide & Aluminium paint is covered separately. Size of lettering to be 100 mm & as per the engineer's instruction. All materials such as teakwood shelf, hylum board, salwood plank, angle iron, square bar, NDT/HRC fuse bases, nuts & bolts etc. shall be supplied by the contractor. ARA terminal will be supplied by the Railway. (i)App. Case half not involving wiring of relays Inspecton by Consignee | — | — | — | 1,00,993.73 | |
| — | 50.00 | — | — | ||
| "Supply & burying of earth electrodes pipe of 3-meter length and 50 mm dia pointed on lower end by tapering for a length of 150mm as per Drg No. RE/S&T/SIG/Tender/SK/26A/85 and connecting with lightning arrester or signalling gears as per standard practices. The item includes digging of pit in earth 3-meter-deep & fixing earth electrode pipe in it. Earth pipe shall be buried to about the length of 2.7 Mts after welding 6 SWG wire at the lower end and fixing through nut & bolt at the top. This includes casting of cement concrete enclosures as per Drg. No.NR/S&T/CON/6.4/97. The enclosure is to be plaster on all sides with cement & sand mixture of 1:4 ratio. The soil treatment shall be done as per standard practices. The item includes provision of earth lead wires and soldering of lead wires. The other end of the earth wire to be connected to block instruments/cable sheath/power equipment/apparatus case/ relay racks or any other equipment as per the instructions of site Engineer & as per IRSEM. The earth resistance should be less than 10 ohm. Inspection by Consignee. | — | — | — | 1,22,334.05 | |
| — | 250.00 | — | — | ||
| Drill bit size 7.14/14 mm HSS parallel shank twist drill(jobber series.) make-Addison similar or better Inspection by consignee. | — | — | — | 56,371.25 | |
| — | 2.00 | — | — | ||
| Supply of Digital Insulation Tester (Megger) 100V/500V, Motwani, Philips or equivalent make similar or better. Material to be supplied as per specifications in Annexure-A. Inspection by consignee. | — | — | — | 11,955.11 | |
| — | 5.00 | — | — | ||
| Self-propelled motorized rail drilling machine suitable for 52KG/60KG rail and compatible for drilling 7.1 mm to 32 mm diameter holes. Accepted make: Roshan or similar or better. Inspection by consignee. | — | — | — | 2,34,690.9 | |
| — | 4.00 | — | — | ||
| Digital earth tester 4 Terminal, range 0-10/100 ohm with Ni-cd rechargeable battery with accessories kit and other required accessories TEC spec no.GR/TIE-10-April or latest Inspection: Consignee) | — | — | — | 28,037.42 | |
| — | 30000.00 | — | — | ||
| Loading, leading & unloading of released material from site to the AMV store at Lucknow or to any other store of Moradabad Division by contractor. Loading, leading & unloading of material, to be supplied by railway from a store located more than 100 Km from the concerned consignee of the work. Inspection: Consignee | — | — | — | 2,38,830 | |
| — | 10.00 | — | — | ||
| Supply of maintenance mechanical tool kit which includes: - (a) Hammer hand medium (500 gms) = 01 Nos , (b) Goti Handle 12" socket = 01 Nos , (c) Socket in goti 19 mm= 01 Nos ,(d) Socket in goti 30 mm= 01 Nos ,(e) Socket in goti 16 mm= 01 Nos ,(f) Socket in goti 13 mm = 01 Nos ,(g) Socket in goti 10 mm = 01 Nos ,(h) Wire cutter 6" = 01 Nos ,(i) Nose plier 6" = 01 Nos , (j) Screw driver 6" = 01 Nos , (k) Plier electric 6" = 01 Nos , (l) Screw driver kit (6PC) = 01 Nos ,(m) Spanner D/E (30x32)= 01 Nos , (n) Spanner D/E (17x19)= 01 Nos , (o) Spanner D/E (32x36) = 01 Nos , (p) Spanner S/E (45) = 01 Nos , (q) Adjustable Key (12-300mm)= 01 Nos , (r) Screw Driver 16"= 01 Nos . All the items should be of reputed make Tapiria , Pie or similar or better. Inspection by consignee. | — | — | — | 51,031.45 | |
| — | 10.00 | — | — | ||
| Supply of Electric tool kit which include:- (a) Spanner D/E round end 8 key set (6x22) = 01 Nos , (b) Spanner D/E open end 8 key set (6x22) = 02 Nos , (c) Plier electric 8" = 01 Nos (d) Plier electric 7" = 01 Nos (e) Wire cutter stipper = 01 Nos , (f) Screw driver 12"= 01 Nos , (g) Hammer (500 gm) = 01 Nos , (h) Soldering iron = 01 Nos. All the items should be of reputed make Tapiria, Pie or similar or better. Inspection by consignee. | — | — | — | 31,876.61 | |
| — | 1000.00 | — | — | ||
| Supply of wiring material as per IRS Spec No. IRS-S 76/89 with amendment No.3 or latest dulyinspected by RDSO, Copper wire PVC sheated & PVC insulated sizes as under: (i) Indoor cable of 40x1 mm. Inspecton by Consignee | — | — | — | 3,85,443 | |
| — | 10.00 | — | — | ||
| Supply of cable/wire indoor copper conductor single/multi core plain annealed high conductivity PVC insulated unamoured as per Spec. no. IRS-S/76/89 (Amd 3) or latest amendment of the following sizes :- (i) Wire 16x0.2mm. Inspection : RDSO | — | — | — | 76,558.86 | |
| — | 3.00 | — | — | ||
| Supply of power wires IS2465/1984 & IS 694/1990 or latest & As per IRS Spec No. 76/89(Amd.3 ) or latest of the following sizes :- (i)1x6sqmm. (Red & black). Inspection : RDSO | — | — | — | 1,76,901.52 | |
| — | 50.00 | — | — | ||
| Supply Installation and commissioning of maintenance free earthing system which consists of supply of earthing kit-1 set consisting of (1) Earth Electrodes of copper clad steel alloy of 10 feet (3mts) long, 17mm dia and copper thickness of 250 microns- 1Nos. (II) RDSO approved Earth enhancing compound in 30 kg. Pack - 01 Nos. (III) Copper tape of 25mm x 6mm x 300mm with 99% purity - 02 Nos. and another of 25 mm x 6mm x 150mm to terminate on earth electrode. (iv). This include supply of 35 Sq.mm/16 Sq. mm/10Sq.mm multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to the equipment. The Earthing material shall be supplied as per RDSO specification RDSO/SPN/197/2008 or latest. Material to be procured through RDSO approved sources Inspection by Consignee. | — | — | — | 8,37,409.85 | |
| — | 2.00 | — | — | ||
| Supply of TDR Based cable fault locator for metalic cables Viz LV Power cable/ Control cables/Signalling cables fault location capability 15 km (45000ft) accuracy: Plus/minus 3 ft at 10,000 ft. One step step configurable for any cable type and VP (0.300 to 1000) measures distance to fault in feet meter or time , two pair test capability , Automatic instrument control mode, splash and drip proof, pair comparison mode, splits/coss talk lit display , input protection plus/minus 200 VDC Plus peak AC to a maximum of 440 Hz, battery operated , including :Test loads (Min 2 pair) carrying case battery use manual & free demo at consignee premises model TS 90 of Tempo (Stanley) or similar of make / Green less/ Megger (As per enclosed technical compliance) Material to be supplied as per specifications in Annexure-A . Inspection by Consignee. | — | — | — | 2,91,540.71 | |
| — | 100.00 | — | — | ||
| Wiring of relays in relay room/relay huts etc. as per appd wiring diagrams. All wiring material including resistances and condensers etc. except cables/wires to be supplied by contractor (Supply of cables & wires covered separately). It also includes dressing, bunching, lacing and fixing of relay bases. Inspection by Consignee | — | — | — | 52,807.1 | |
| — | 20.00 | — | — | ||
| Supply & Installation of VF transformer (1120/470) as per IRS Spec. No. TC-22-76 or latest) with suitable fixtures and wiring Inspection by Consignee | — | — | — | 41,041.18 | |
| — | 2.00 | — | — | ||
| Supply of SM/SI/ESM furniture of Godrej or similar make consisting of the following:- 1. Executive revolving bearing series low back floating chair with normal arms cushioned chair:1 no. 2. Executive table size 72""x36""x30"" with 3 drawers one side, Lockers cabinet on other side:1 no. 3. Visitors chair seat & back cushion with high density foam with plastic PVC handle capsul type flat pipe duly painted black: 3 nos. 4. Almirah steel with locking arrangement size 1277mmx765mmx440mm=1no . Inspection by consignee | — | — | — | 75,167.91 | |
| — | 2.00 | — | — | ||
| : Supply of remote fault diagnostic system configuration Intel core I7 operating system, window 8.1 or better or similar. (acer tmp 246 or better or similar). Material to be supplied as per specifications in Annexure-A Inspection by consignee | — | — | — | 1,26,158.31 | |
| — | 2.00 | — | — | ||
| Supply of laser printer make HP/CANON/SAMSUNG/XEROX HP 1020 plus Monochrome Laser printer or better or similar. Material to be supplied as per specifications in Annexure-A. Inspection by Consignee | — | — | — | 15,900.87 | |
| for details. | Breakup | — | — | ||
| Supply of disconnect terminal Wago or similar as per spec. No. RDSO/SPN/189/2004 Ver 3.0 or latest as below Inspection by RDSO. | — | — | — | 83,380.5 | |
| — | 20.00 | — | — | ||
| Supply and installation of IPS module of capacity 24-32 Volt DC O/P 05Amp Suitable work on existing IPS of concerned stations. (make as per requirement of site Engineer) (IRS:S 96- 2000). Inspection: RDSO | — | — | — | 3,12,924.62 | |
| — | 5.00 | — | — | ||
| Standard Tool Kit for Installation Testing and maintenance of Digital Axle counter system consisting of :(i) Pure sine wave Digital multimeter Kusam MECO make or similar model no.859 CF or equivalent= 01No. (ii) Train simulator (Model TS 267 P)=01 No. (iii) Extender card no. 557=01 No. (iv) Dummy wheel = 01No. (v) Spanners: (a) Ring spanner 17-19,24-26=01 No. each (b) open End spanner 17-19,24-26=01no. each (c) Socket spanner with handle=01 no. (vi) Screw driver no.902=01 no. (vii) Screw driver no.935=01 no. (viii) Marking jig for drilling=01 No. (ix) Torque wrench=01 No. (x) Dummy Load=01 No. Inspection by RITES | — | — | — | 5,49,975.02 | |
| — | 1.00 | — | — | ||
| Supply and testing of the cable route tracer and marker locator and Integrated cable route tracer and marker locator 2273 M or similar or superior. Material to be supplied as per specifications in Annexure-A. Inspection: Consignee | — | — | — | 2,57,565.08 | |
| — | 10.00 | — | — | ||
| Supply of AC/DC digital clamp meter to Motwane model No. DCM 39 A or equivalent in extech , Fluke , Rishabh or similar or better. Material to be supplied as per specifications in Annexure-A. Inspection: Consignee | — | — | — | 1,38,955.54 | |
| — | 50.00 | — | — | ||
| Supply & Installation of Thermo shrink jointing kit for 6-Quad cable for straight through joints as per IRS: IRS: TC 77-2012 (Rev.3) with latest amendments. Inspection: RDSO | — | — | — | 3,22,104.35 | |
| — | 8.00 | — | — | ||
| Supply of 1U height TDM multiplexer V.21/V.23 to E1, standard 19' rack mountable device consisting of one E1 port and two V.21 interface with changeover Quad ports: unit to support Potential free contacts four numbers can be linked with data logger/RTU for E1 status, Quad status & Power supply status units supports DC power supply 18 VDC to 72 VDC range & AC vide DC to AC adaptor one number provided: Make: Team Engg/Lantana/Waves/FABIO, accepted make :- TEAM LINK FABIO 1CX batter or similar. Material to be supplied as per specifications in Annexure-A. Inspection by RITES | — | — | — | 5,84,096.63 | |
| — | 4.00 | — | — | ||
| Supply of Auto battery charger input 230V AC output 24V DC, 40//60Amp. For signalling purpose to IRS-S-86-2000, with amendment no. 4 or latest. Inspection: Consignee | — | — | — | 3,07,293.31 | |
| — | 500.00 | — | — | ||
| Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS : S - 78 / 92 with latest amendments, 2A / 4A / 6A / 8A / 10A rating capacity. Inspection: RDSO | — | — | — | 43,876 | |
| — | 500.00 | — | — | ||
| Supply of electric fuse complete with fuse block made of PBT for Railay signaling as per IRS-S-75 /2006 Rev. 2 or latest fuse non -deteriorating type low voltage to suit specification no. IRS. S-78/92 or latest Fuse 2/4/10/16 Amp, fuses . Fuse block shall be suitable for round head type fuse. Inspection: RDSO | — | — | — | 1,15,299 | |
| — | 8.00 | — | — | ||
| UPort 1110 Moxa 1 Port USB-to-Serial Adaptor, RS-232. Material to be supplied as per specifications in Annexure-A. Inspection: Consignee | — | — | — | 33,040 | |
| — | 5.00 | — | — | ||
| Multifunction Machines Mfm, On Site OEM Warranty 1 Year Brother DCP-T820DW or similar. Material to be supplied as per specifications in Annexure-A. Inspection by Consignee | — | — | — | 92,207.8 | |
| — | 2.00 | — | — | ||
| Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/4.1/97A made of angel iron size 45mmx45mmx6mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors & fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection : Consignee | — | — | — | 42,954.48 | |
| — | 3.00 | — | — | ||
| Tool Kit for High Availability Single Section Digital Axle Counter as per Specification No. RDSO/SPN/177/2012(Version - 3) or latest, consisting of :- (i) Portable Data Analyser (Downloading Event Logger Data for analysis and report generation) - 1 No. (ii) Pure Sine Wave Digital Multi-meter Fluke Make (Model-1871) or Rishab Make (Model-28S) - 1 No. (iii) Extender Card - 1 No.(iv) Dummy Wheel -1 No. (v) Ring Spanner (17-19, 24-26) - 1 No. each (vi)Open End Spanner (17-19, 24-26) - 1 No. each (vii) Socket Spanner with Handle - 1 No. (viii) Torque Wrench (JaicomJPR or equivalent 88 NM_ - 1 No. (ix) Screw Driver No. 902or as directed by Engineer-in-Charge - 1 No. (x) ScrewDriver No. 935 or as directed by Engineer-in -Charge - 1No. (xi) Marking Jig for Drilling - 1 No. (xii) Dummy Load to check Power Supply (Resistive) - 1 No. and any other additional specialized Tools suggested by RDSO Approved OEM required for Trouble Shooting and Maintenance of Equipment. Material to be supplied as per specifications in Annexure-A. Inspecton by RITES | — | — | — | 6,81,255.36 | |
| — | 5.00 | — | — | ||
| DC-DC 24-32V/10A CONVERTERS SUITABLE FOR IPS SYSTEMS AND CONFORMING TO RDSO SPEC NO. RDSO/SPN/165/2012 VER 3.0 OR LATEST. (make as per requirement of site Engineer). Inspection: RDSO | — | — | — | 1,12,100 | |
| — | 32.00 | — | — | ||
| : Supply and installation of 60-66V, 5A DC-DC converter as per RDSO/SPN/165/2012 Ver.3.0 or latest (make as per requirement of site Engineer). Inspection: RDSO | — | — | — | 8,63,445.34 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .