GARRISON ENGINEER ABOHAR
GARRISON ENGINEER ABOHAR PIN 152116
SPL REPAIR OF SEWAGE LINE BEHIND COOK HOUSE FROM BLDG NO P-143 TO P-148 OF THE INF BN-II AND BLDG NO P-15, P-14, P-59 TO P-62, P-37 TO P-42, P-65 AND P-66 AT MILITARY STATION ABOHAR.
2024_MES_662869_1
TOKEN NO GE ABH-29/24-25
Open Tender
Civil Works
Item Rate
180 days
ABOHAR MIL STN
AS PER NIT
7 documents required · 7 mandatory
₹500
GE ABOHAR
₹61,460
Yes
1 Jan 2025
29 Jun 2024
5 Sept 2024
29 Jun 2024
3 Sept 2024
13 Jul 2024
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations etc or manholes, cesspits, pipes and cables etc. not exc 10 Sqm on plan and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 01 here in before but exceeding 1.5m and not exceeding 3m in depth all as specified and directed by Engineer - in – Charge.
Excavating over areas, n.exc 1.5m deep in any type of soil and getting out.
Excavating over areas, exc 1.50 m but n.exc 3.00 m deep in any type of soil and getting out.
Excavating over areas, exc 3.00 m but n.exc 4.50 m deep in any type of soil and getting out.
Returning, filling in, including spreading, levelling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge .
M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer - in - Charge
Demolition of cement concrete (reinforced) in roof slab ,manhole cover, floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work all as specified and directed by Eng-in-Charge.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole set in cm (1:6) complete all as specified & directed . ( Note : Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor & reinforcement shall be measured & paid Separately.)
M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc complete all as specified and directed by Engr in Charge..
S&F TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified .
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc .
M&L for Old size burnt clay Brickwork with sub class 'B' straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Labour only for Brick work built in CM (1:6) with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius with Reusing the old bricks obtained
Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge.
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
Demolition and breaking upto 150mm bore drain pipes, salt glazed ware or AC pipe set in cement mortar and taking out from trenches all as specified and directed by Engineer - in – Charge.
Reinforced concrete pipes 150mm bore class NP-3, laid and jointed complete with collars, all as specified and directed by Engineer - in - Charge.
Demolition and breaking up 200mm bore drain pipes, salt glazed ware or AC pipe set in cement mortar and taking out from trenches all as specified and directed by Engineer - in – Charge.
Reinforced concrete pipes 200mm bore class NP-3, laid and jointed complete with collars, all as specified and directed by Engineer - in - Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benches for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm internal dia for pipe all as specified and directed by Engineer - in - Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benches for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200mm internal dia for pipe all as specified and directed by Engineer - in - Charge.
Removing the manhole cover (CI or RCC) for opening of septic tank of various capacities and taking out sludge / solid contents / night soil with manual labour or by mechnical pumping (at contractor's discretion) making it fully functional and cleaning the internal surfaces with water to the entire satisfaction of Engineer-in-Charge including removal of sludge / solid contents / night soil outside the defence land and refixing the manhole cover to its original position complete all as specified and directed by Engineer in Charge.
All as per item above but interceptiing chambers of size 1.5mx1.00m
Cleaning of existing sewage pipe line 200/150/100mm internal dia by rodding / manually as required at site from man holes and well flushing after cleaning including getting out sludge if any and liquid materials from connecting man holes, deposited in lines removing the solids and sludge to any distance place outside the defence land at their own cost and the cost of removal shall be included in this rate all as specified and directed by Engineer - in - Charge. Note : (i) The night soil and sediments including liquid removed form septic tank are to be taken away from the recpective vicinities on covered conveyance and disposed off out side defence area. (ii) Volume of septic tank will be worked out based on the depth excluding free board or actual depth of sludge, whichever is less.
Dismantling of cast iron pipes jointed in cement mortar and taking out from trenches walls etc upto 100 mm bore all as specified and directed by Engineer - in - Charge .
S & F PVC(SWR) 110 mm bore Pipes single socketed in any length with pressure rating not less than 6kgf/sqcm ,rubber ring joints,laid in trenches or in floors all as specified and directed by Engineer - in - Charge.
S & F PVC(SWR) 75 mm bore Pipes single socketed in any length with pressure rating not less than 6kgf/sqcm rubber ring joints,laid in trenches or in floors all as specified and directed by Engineer - in - Charge.
S&F PVC (SWR)branch pieces single /double (equal or unequal) ordinary or inverted with parallel branches 110mm bore
Ditto all as above but 75 mm bore.
S&F PVC(SWR) bend ( any radius) dimenshing pieces or tappers ( large bore measured) 110mm bore with access door
-ditto- all as above but 75 mm bore with access door
S & F PVC(SWR) Vent cowls 110mm bore all as specified and directed by Engineer - in - Charge.
P.K ENTERPRISES (BID ID -3068126)
SHRI SHYAM CONSTRUCTION CO. (BID ID -3071916)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .