Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 22 2ND FLOOR HIMALAYA HOUSE 23 K G MARG CANNAUGHT PLACE NEW DELHI 110 001 | NEW DELHI | DELHI | 110001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical Bidder does not meet BEC Criteria |
Tender Value
Refer Docs
EMD Value
₹24.8 L
Closing Date
3 May 2023, 3:00 pmClosed
PROJECT MANAGER
PROJECT MANAGER PDIL NOIDA
SUPPLY CUM ERECTION OF ELECTRICAL AND INSTRUMENTATION WORKS ON ITEM RATE BASIS
2023_PDIL_744266_1
PNPM/PC-183/E/8003/NCB
Open Tender
Electrical Works
420 days
TALCHER
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹24.8 L
Yes
PDIL NOIDA
23 Aug 2023
9 Mar 2023
4 May 2023
9 Mar 2023
3 May 2023
29 Mar 2023
20 Mar 2023
Amount
SUPPLY OF ELECTRICAL ITEMS (SUPPLY: PART-A)
TRANSFORMERS
Supply of Transformers with all accessories, as specified in data sheets, Technical Specification - Electrical, Technical Specification Doc. No. PC183-TS-0802, etc. attached with the NIT.
2000 KVA, 11/0.433 kV, ONAN, Dyn11, 3 phase, 50 Hz, Oil immersed type transformer with externally operated off circuit tap changer with tapping range of + 5% in steps of 2.5% and Z=7.25% (zero negative tolerance) with all applicable fittings and accessories.
1600 KVA, 11/0.433 kV, ONAN, Dyn11, 3 phase, 50 Hz, Oil immersed type transformer with externally operated off circuit tap changer with tapping range of + 5% in steps of 2.5% and Z=6% (zero negative tolerance) with all applicable fittings and accessories.
1250 KVA, 11/0.433 kV, ONAN, Dyn11, 3 phase, 50 Hz, Oil immersed type transformer with externally operated off circuit tap changer with tapping range of + 5% in steps of 2.5% and Z=6% (zero negative tolerance) with all applicable fittings and accessories.
deleted
HT CAPACITOR BANK
Supply of Capacitor Bank alongwith VCB, RVT, series reactor, Control Panel, APFC Relay, HT vacuum contactor, HT Fuse, Relays etc. complete in all respect as per Technical specification - Electrical, Technical Specification - Capacitor (Doc. No. PC183-TS-0822) etc.
300 KVAR Capacitor bank (2 Steps of 100KVAR,200KVAR each), 3.3 KV Voltage Level
500 KVAR Capacitor bank (3 Steps of 100KVAR,200KVAR,200KVAR each), 11 KV Voltage Level
CABLES (HT & LT)
Supply of 11KV (UE) grade XLPE insulated, PVC inner sheathed, armoured, FRLS PVC (ST2) type outer sheath as per Technical specification - Electrical, Technical Specification - Cables (Doc. No. PC183-TS-0815) etc
Supply of 3.3KV (UE) grade XLPE insulated, PVC inner sheathed, armoured, FRLS PVC (ST2) type outer sheath as per Technical specification - Electrical, Technical Specification - Cables (Doc. No. PC183-TS-0815) etc.
Supply of1.1KV grade, XLPE insulated, PVC inner sheath, armoured, FRLS PVC (ST2) type outer sheath as per Technical specification - Electrical, Technical Specification - Cables (Doc. No. PC183-TS-0815) etc.
3.5C x 630 mm2 (Al)
3.5C x 400 mm2 (Al)
3.5C x 300 mm2 (Al)
3.5C x 240 mm2 (Al)
3.5C x 150 mm2 (Al)
3.5C x 120 mm2 (Al)
3.5C x 70 mm2 (Al)
3.5C x 50 mm2 (Al)
3.5C x 35 mm2 (Al)
3.5C x 25 mm2 (Al)
4C x 35 mm2 (Al)
4C x 25 mm2 (Al)
4C x 16 mm2 (Al)
3C x 120 mm2 (Al)
3C x 70 mm2 (Al)
3C x 50 mm2 (Al)
3C x 35 mm2 (Al)
3C x 25 mm2 (Al)
3C x 10 mm2 (Cu)
3C x 6 mm2 (Cu)
3C x 4 mm2 (Cu)
3C x 2.5 mm2 (Cu)
5C x 2.5 mm2 (Cu)
7C x 2.5 mm2 (Cu)
12C x 2.5 mm2 (Cu)
19C x 2.5 mm2 (Cu)
1Cx185 mm2 (Al) Unarmoured
1Cx16 mm2 (Al) Unarmoured
Supply of 6 Fiber multi mode FO Cable suitable for relay to relay distance of approx 2 kM for line differential protection with all aceessories for termination , this also inlude splicing, jointing as per requiremnt etc.
CABLE TRAYS:
Supply of prefabricated ladder type GI cable trays and their accessories i.e. supply of all hardware required i.e. J-hooks, GI Nut, Bolt, Washers, coupling plate etc. of following sizes as per Technical specification - Electrical, Technical Specification - Cables (Doc. No. PC183-TS-0816) etc.
Straight Run Cable Trays
600 mm wide
450 mm wide
300 mm wide
150 mm wide
Horizontal Bends
600 mm wide, 700 mm radius
450 mm wide, 700 mm radius
300 mm wide, 700 mm radius
150 mm wide
Vertical Inside Bends
600mm wide, 1000mm radius
450 mm wide, 1000mm radius
300 mm wide, 1000mm radius
150 mm wide
Vertical Outside Bends
600 mm wide, 1000 mm radius
450 mm wide, 1000 mm radius
300 mm wide, 1000 mm radius
150 mm wide
Reducer
600 mm / 450 mm wide
450/300mm wide
300/150mm wide
Regular Tees
600 mm wide , 700 mm radius
450 mm wide, 700 mm radius
Cross
600 mm wide , 700 mm radius
450 mm wide, 700 mm radius
EARTHING AND LIGHTNING PROTECTION
Supply of GI earth strip / Wire conductors of following sizes as per PDS attached with TS (with min. coating 610 gm / sq. m) of following sizes: -
75 mm x 10 mm
50 mm x 6 mm
35mm x 6mm
GI wire Rope (8 SWG)
Spares for Two Years Operation (Mandatory)
Supply of spares of following equipments
Capacitor Bank
Supporting insulators
Unit capacitor bank of each type & rating
PA system
Electronic card for central exchange
Electronic Amplifier card for FCS
WP speaker of each type`
FLP speaker
Transformer (2000 KVA, 11/0.433 kV Transformer)
Bushings complete with accessories for all 3 phase & neutral for all voltage grades.
Complete set of gaskets
Equaliser pipe and Explosion vent diaphragm
PRV with alarm and trip
Oil Level Gauge
Complete charge of Silica gel with breather
Gland packing / O-rings for every valve
Buchholz Relay
Analogue type OTI
Analogue type WTI
Radiator(one set of each type)
Complte set of valve(1 no. of each type)
Support insulator( HV Side)
Support insulator( LV Side)
Conservator gauge Glass/Sealing
Thermister with space heater for M.B
3 Pin switch & socket
CT for REF
CT for SBEF
Transformer (1600 KVA, 11/0.433 kV Transformer)
Bushings complete with accessories for all 3 phase & neutral for all voltage grades.
Complete set of gaskets
Equaliser pipe and Explosion vent diaphragm
PRV with alarm and trip
Oil Level Gauge
Complete charge of Silica gel with breather
Gland packing / O-rings for every valve
Buchholz Relay
Analogue type OTI
Analogue type WTI
Radiator(one set of each type)
Complte set of valve(1 no. of each type)
Support insulator( HV Side)
Support insulator( LV Side)
Conservator gauge Glass/Sealing
Thermister with space heater for M.B
3 Pin switch & socket
CT for REF
CT for SBEF
Transformer (1250 KVA, 11/0.433 kV Transformer)
Bushings complete with accessories for all 3 phase & neutral for all voltage grades.
Complete set of gaskets
Equaliser pipe and Explosion vent diaphragm
PRV with alarm and trip
Oil Level Gauge
Complete charge of Silica gel with breather
Gland packing / O-rings for every valve
Buchholz Relay
Analogue type OTI
Analogue type WTI
Radiator(one set of each type)
Complte set of valve(1 no. of each type)
Support insulator( HV Side)
Support insulator( LV Side)
Conservator gauge Glass/Sealing
Thermister with space heater for M.B
3 Pin switch & socket
CT for REF
CT for SBEF
415V LV SWITCHBOARD -
2500A, 50KA for 1 sec ACB / 800 A , 50KA for 1 sec ACB
Arc Chute assembly
Shunt trip coil.
Closing coil
Secondary isolating contact blocks.
CONTROL SWITCHES
Trip-Neutral-Close Control Switch
Push Button Element
Push Button Actuator of each type
Control Fuse
Fuse Link
Fuse Fitting
Microprocessor based numerical relay used in incomer ACB feeder
Microprocessor based numerical relay used in Motor / Outgoing ACB feeder
MCB of each type & rating)
CONTACTOR (of each type & rating )
Overload RELAYS (of each type & rating)
CT for breaker feeders (Each Rating)
CT for other outgoing feeders (Each Rating
MCCB / ELCB MCB
4P/TPN MCCB 400 A
4P/TPN MCCB 250 A
4P/TPN MCCB 160 A
4P/TPN MCCB 125 A
4 P/TPN MCCB 63 A
DP RCBO 63 A
DP MCB, 16 A
DP MCB, 32 A
LIGHTING FIXTURE
Reflector of each type
Heat resistant toughened glass cover of each type
Cable glands of each type
Allen keys of different sizes as applicable.
45W LED street light fixture
60W LED street light fixture
90 W LED street light fixture
INTERLOCKING SWITCH SOCKET & PLUG
Switch of each rating
Fuse base of each rating
Fuse of each rating
Plug Top
11 V ICOG Breaker Panel :BREAKER 11 kV - Trip bar spring and any other spring used in the circuit breaker mechanism
11 V ICOG Breaker Panel :BREAKER 11 kV - Shunt trip coil
11 V ICOG Breaker Panel :BREAKER 11 kV - Closing coil
11 V ICOG Breaker Panel :BREAKER 11 kV - Secondary Isolating contact blocks
11 V ICOG Breaker Panel :BREAKER 11 kV - Micro Switch for Spring Charging
11 V ICOG Breaker Panel :BREAKER 11 kV - Micro Switch for Service/Test position
11 V ICOG Breaker Panel :BREAKER 11 kV - Rack in/Rack out handle
11 V ICOG Breaker Panel :BREAKER 11 kV - Spring Charging handle
11 V ICOG Breaker Panel :BREAKER 11 kV - Door panel key
11 V ICOG Breaker Panel : CONTROL SWITCHES- Trip-Neutral-Close Control Switch
11 V ICOG Breaker Panel : Push Buttons-Push Button Element of each type
11 V ICOG Breaker Panel : Push Buttons- Push Button Actuator of each type
Indication Lamps (1 no. of each type)
Thermostat
MINIATURE CIRCUIT BREAKER (OF EACH RATING)
METERS: Ammeter
METERS: Voltmeter
PART-B : ERECTION, TESTING & COMMISSIONING OF ELECTRICAL ITEMS
415V Switchboard
Handling, installation including transportation from store to site of installation, erection, testing and commissioning of 415V power-control-centres and bus duct, motor control centres, soft starters, APFC panel etc. assembling as required, unpacking, inspection, fabrication and erection of foundation channel, installation on the foundation channels, welding, aligning, leveling, grouting, assembling, fitting of all accessories / instruments / relays, relay coordination, CT, PT, Numerical Relay, interconnection of shipping sections and inter panel wiring as necessary, inter bus bar jointing, bus bar connection, installation, erection, testing and commissioning of bus duct, as per drawing, specifications and directions of the Site Engineer/ Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including supply of WP double compression rolled aluminium cable glands & lugs (Al/Cu/Bimetalic), termination of all power, control cables, installation of thermistor controller, internal wiring, earthing of LT panels & bus duct, making holes for cable entries as required, shrouding, plugging/sealing of all unused cable entries and other holes for making the same dust and vermin proof etc. complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. This shall also include assembling as required, unpacking, inspection, fabrication and erection of foundation channel, installation on the foundation channels, welding, aligning, leveling, grouting, assembling, fitting of all accessories / instruments / relays, relay coordination, CT, PT, Numerical Relay, interconnection of shipping sections and inter panel wiring as necessary, inter bus bar jointing, bus bar connection, installation, as per drawing, specifications and directions of the Site Engineer/ Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including supply of WP double compression rolled aluminium cable glands & lugs (Al/Cu/Bimetalic), termination of all power, control cables, installation of thermistor controller, internal wiring, earthing of LT panels , making holes for cable entries as required, shrouding, plugging/sealing of all unused cable entries and other holes for making the same dust and vermin proof etc. complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
415V, 3 Ph & N, upto 3200 A, 50kA for 1 sec., Draw out type, Double front, indoor type Low Voltage switchboard (Power & Motor Control Centre, PMCC) approximately 14 Bay
415V, 3 Ph & N, upto 2500 A, 50kA for 1 sec., Draw out type, Double front, indoor type Low Voltage switchboard ( Power & Motor Control Centre, PMCC) approximately 12 Bay
415V, 3 Ph & N, upto 2500 A, 50kA for 1 sec., Draw out type, Double front, indoor type Low Voltage switchboard (Emergency Power & Motor Control Centre, EPMCC) approximately 10 Bay
TRANSFORMER
Handling, storage at site, transportation from store to site of installation, erection, installation, testing and commissioning of (outdoor type - ONAN cooled) transformer, erection of transformer over the rail and foundation channels, including transporting, unpacking, rigging, aligning, levelling, grouting, assembling, fitting and fixing all accessories/instruments/relays etc. supplied separately if any, etc., supply of WP double compression rolled aluminium cable glands & suitable lugs (Al/Cu/Bimetalic), making all the interconnections & termination of all power (HT/LT) cables, control cables / busbar etc. as per drawings, including earthing/grounding of transformer neutral as per drawing, equipments needed to completely install and commission the transformer Job complete in all respect including cost of all labour, tools and materials and all services rendered complete, installation of thermistor controller, internal wiring, earthing of LT panel etc. complete as per drawings and directions of the Site Engineer / engineer-in-Charge. Note: Commissioning assistance shall be provided by the supplier of the Transformer as and when required at site.
2000 KVA, 11/0.433 kV Transformer (ONAN), 50 Hz, Dyn11with off load tap changer
1600 KVA, 11/0.433 kV Transformer (ONAN), 50 Hz, Dyn11 with off load tap changer
1250 KVA, 11/0.433 kV Transformer (ONAN), 50 Hz, Dyn11 with off load tap changer
TRANSFORMER OIL :
Centrifuging,filtering and dehydrating of the transformer oil of transformer to improve insulation level to the value recommended as per the relevant ISS and the manufacturer's recommendations and as per specifications,and directions of the Site Engineer/Engineer-in-Charge including supply of labour, tools and materials and all services rendered complete.
Transformer Oil.
HT CAPACITOR BANK
Erection, Installation including within site transportation, testing and commissioning of HT capacitor bank along with all installation of all accessories including termination of all control cables, installation on foundation channels, drilling, cutting, welding, aligning, levelling, grouting, assembling and fitting all accessories / instruments / relays connection of 230 V Supply / battery bank 220 V DC supply, earthing of HT capacitor bank, making all the interconnections/ outgoing/incoming LT power & control cable connections including making holes for cable entries as required with materials i.e. WP double compression Cable glands, end lugs, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. Note: Commissioning assistance shall be provided by the supplier of the HT capacitor bank as and when required at site.
300 KVAR Capacitor bank (2 Steps of 100KVAR,200KVAR each), 3.3 KV Voltage Level
500 KVAR Capacitor bank (3 Steps of 100KVAR,200KVAR,200KVAR each), 11 KV Voltage Level
ELECTRIC HEATER WITH THYRISTOR CONTROL PANEL:
Handling, installation including transportation from owner's store to site of installation, erection, testing and commissioning of 690V/415 V, owner supplied electric heater alogwith thyristor control panels, J.B., LCS, etc. assembling as required, installation on the already made foundation channel, aligning, levelling, grouting, assembling, making all the inter connections / outgoing / incoming power & control cable / connection including making holes for cable entries as required as per drawing, specifications and directions of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all power, control cables, installation of thermistor controller, internal wiring, earthing of control panels, supply of FLP cable glands and suitable cable lugs (Al/Cu/Bimetalic) etc. complete as drawings, specification and directions of Site Engineer / Engineer-in-Charge etc.
TESTING & COMMISSIONING of MOTORS
HT MOTOR (11KV/3.3KV):
Testing & comissioing of owner supplied, 3-Phase Squirrel Cage, HT induction Motors. The job includes dehydration of motors, execution of terminal connections with HT power, LT power and control cables, earthing of Motor / Local speed controller, armour of all the cables etc., with materials i.e. FLP double compression rolled aluminium cable glands, Suitable end lugs(Aluminum/copper/Bi metalic), labour, tools and tackles, consumables etc. including dehydration of the following motors to improve the insulation resistance value of the winding to the required level as per direction of the site in-charge, as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
HT Motor rating below 500 KW and greater than 150 KW
HT Motor rating above 500 KW and below 1500 KW
HT Motor rating 1500 KW and above
Testing and commissioning of 3-Phase, 415V, Squirrel Cage, Hoseproof/Flameproof Induction Motors of following ratings excluding cable glanding, cable termination, dehydration of windings but including checking & replenishment/ replacement of bearing grease/ lubricant; checking of IR values between each winding & motor frame & checking of continuity of rotation, if required, by changing supply connections; trial runs on NO LOAD & ON LOAD; supply of approved grease/ lubricant & necessary hardware; all work, labour & materials complete as per specifications, documents, codes & standards & directions of engineer-in-charge. (Contractor to keep proper record of tests on motors for NO LOAD & ON LOAD runs)
Rating upto 5.5 KW
Rating above 5.5 KW but upto 11 KW
Rating above 11 KW but upto 22 KW
Rating above 22 KW but upto 45 KW
Rating above 45 KW but upto 75 KW
Rating above 75 KW but upto 150 KW
CABLES (HT & LT)
Handling, Laying (horizontal & vertical), testing and commissioning of 11KV(UE)/ 1.1 KV Grade, XLPE Insulated, PVC inner sheathed, armoured, FRLS PVC outer sheathed cables including its termination in new & readymade trenches, on pre-fabricated/ site-fabricated cable trays/ racks, on already installed risers, support, hangers,saddles / directly burried up to 700mm depth etc. pulling through pipes on walls/columns, steel structures including transportation of cable drums from storage yard to site, unrolling the drum, including supply & fixing of cable tags, Al clamps with all labour, consumable materials and necessary hardware to make installation complete in all respect as per direction of Site Engineer / Engineer-in-charge.
HT (11KV/3.3 KV) Power cables
Power cables HT (11kv/3.3KV) upto 400 sq. mm
LT (PVC / XLPE / Armoured / Unarmoured / Power / Control / Signalling) Cables
LT cables: OD upto 20 mm
LT Power cables: OD above 20 mm and upto 30 mm
LT cables: OD above 30 mm and upto 40 mm
LT cables: OD above 40 mm and upto 60 mm
LT cables: OD above 60 mm
Handling,laying of 6 Fiber multi mode FO Cable suitable for relay to relay distance of approx 2 kM for line differential protection with all aceessories for termination , this also inlude splicing, jointing as per requiremnt
EARTH STRIP / WIRE / ROPE / CABLE
Earthing strip/wire/rope/cable for completely making the earthing grid system by laying the GI strip / GI Wire enclosed in ready made concrete trenches or in floor slits, on brick / concrete wall under concrete floors, or paved areas, across pipe joints and valves, directly buried under ground at depth of 600 mm, including handling, transportation to erection site, bending, straightening, cutting to size, welding together of earth strips in overlapping manner, chipping in concrete floors / paved areas for laying the earth strips under floors / paved areas and making good by cement plastering concrete after laying of the strips; clamping and supporting of earth strips laid above ground, connecting the strips / wire at both ends to equipment or to earth bus / earth plates or to GI brackets fixed inside earthpit chamber, by bolting etc., Hessian tapes, all necessary GI hardware, GI clamps, civil masonry materials, etc. all work, labour as per specifications, codes and standards and directions of Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect. Note: The conductors shall be laid at a minimum depth of 600 mm from ground level.The excavation for the GI earth conductors / strips shall not be separately measured and the rates quoted to include the same.
75 mm x 10 mm
50 mm x 6 mm
GI wire Rope (8 SWG)
Handling,Installation, Testing and Commissioning of 35x6 GI strip on parapet of surface of wall for lightning conductor as required for vertical run including test link etc & horizontal run along wall,column,prapet etc complete with PVC fasteners,screws,Saddles, and welding/revetting and painting of joints etc as required.
CABLE TRAYS:
Handling, installation & fixing of prefabricated ladder GI cable trays and their accessories i.e. supply of all hardware required i.e. J-hooks, GI Nut, Bolt, Washers, coupling plate etc. of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr.) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc. as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. The rates shall be valid for all mounting heights.
Straight Run Cable Trays
600 mm wide
450 mm wide
300 mm wide
150 mm wide
Horizontal Bends
600 mm wide, 700 mm radius
450 mm wide, 700 mm radius
300 mm wide, 700 mm radius
150 mm wide
Vertical Inside Bends
600mm wide, 1000mm radius
450 mm wide, 1000mm radius
300 mm wide, 1000mm radius
150 mm wide
Vertical Outside Bends
600 mm wide, 1000 mm radius
450 mm wide, 1000 mm radius
300 mm wide, 1000 mm radius
150 mm wide
Reducer
600 mm / 450 mm wide
450/300mm wide
300/150mm wide
Regular Tees
600 mm wide , 700 mm radius
450 mm wide, 700 mm radius
Cross
600 mm wide , 700 mm radius
450 mm wide, 700 mm radius
PART-C : SUPPLY, ERECTION, TESTING & COMMISSIONING OF ELECTRICAL COMPOSITE ITEMS
DISTRIBUTION BOARDS:
Supply, unloading, Handling, Storage, transporation within site, Erection, Installation, testing and commissioning etc. of following floor / wall mounted Distribution Boards/Sub distribution board having minimum IP-54 protection, Copper Bus Bar with Color Coded Heat Shrinkable Sleeves, storage, handling, site trasporation from store to site of installation, including supply and fabrication of epoxy painted MS frame, operational and functional checking, drilling of gland plates with requisite holes, supply & fixing of suitable double compression nickel plated brass/rolled Al cable glands & suitable lugs, termination of all power and control cables, shrouding,plugging of all unused cable entries and other holes found in the boards to make the same dust and vermin proof with all labour and consumable materials to make installation complete of following Distribution Boards as specified in Technical Specification - Electrical,Technical Specification PC183-TS-0805 PC183-TS-0808 and attached SLD, data sheets, drawings, specifications and directions of engineer-in-charge :
415 V, 3 Ph & N, IP54 floor mounted sheet steel enclosed Main Lighting Distribution Board MLDB) consisting of 2 nos. incoming 250 A MCCB incomer with 200/1 CT, 250A contactor, MFM, voltmeter, VSS & RYB indications & 5 nos. 63 A TPN RCCB outgoing feeders on indoor bus and 4 nos. 125A TPN RCCB & 3 nos. 63A TPN RCCB outgoing feeders on outdoor bus with Photocell controlled (125A contactor with MCCB) as indicated in attached SLD enclosed with Technical specification
415 V, 3 Ph & N, IP54 floor mounted sheet steel enclosed Main Lighting Distribution Board MLDB) consisting of 2 nos. incoming 630 A MCCB incomer with 600/1 CT, 550A contactor, MFM, voltmeter, VSS & RYB indications & 3 nos. 63 A TPN RCCB /125 A TPN MCCB outgoing feeders on indoor bus and 6 nos. 250A TPN MCCBs & 3 nos. 63 A TPN RCCB /125 A TPN MCCB outgoing feeders on outdoor bus with Photocell controlled (500A contactor with 630 A MCCB) as indicated in attached SLD for MLDB enclosed with Technical specification
415 V, 3 Ph & N, IP52, floor mounted sheet steel enclosed Power Distribution board (PCC) consisting of 2 nos. incoming 2500A ACB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
415 V, 3 Ph & N, IP54,floor mounted sheet steel enclosed Power Distribution board (PDB-1 (N1) Workshop) of 1 nos. incoming 800A ACB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
415 V, 3 Ph & N, IP54,floor mounted sheet steel enclosed Power Distribution board (PDB-2 for Small Loads) of 1 nos. incoming 250A MCCB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
415 V, 3 Ph & N, IP54,floor mounted sheet steel enclosed Power Distribution board (PDB-4 for Small Loads) of 1 nos. incoming 250A MCCB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
415 V, 3 Ph & N, IP54,floor mounted sheet steel enclosed Power Distribution board (PDB-1 for Small Loads) of 1 nos. incoming 250A MCCB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
415 V, 3 Ph & N, IP54,floor mounted sheet steel enclosed Power Distribution board (PDB-3 for Small Loads) of 1 nos. incoming 250A MCCB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
415 V, 3 Ph & N, IP54,floor mounted sheet steel enclosed Power Distribution board (PDB-3 for Small Loads) of 1 nos. incoming 250A MCCB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
415 V, 3 Ph & N, IP54,floor mounted sheet steel enclosed Power Distribution board (PDB-2(E) Workshop) of 1 nos. incoming 250A MCCB Incomer & nos. of outgoing feeders as indicated in attached SLD enclosed with Technical specification.
WALL / STRUCTURE MOUNTED SUB DISTRIBUTION BOARDS / FEEDAR PILLAR BOXES
Supply,unloading,Handling, Storage,transporation within site, Installation, testing and commissioning of following floor / wall mounted Distribution Boards, including supply and fabrication of epoxy painted MS frame, operational and functional checking, drilling of gland plates with requisite holes, fixing of cable glands, plugging of all unused cable entries and other holes found in the boards to make the same dust and vermin proof with all labour and consumable materials to make installation complete of following wall / structure mounted Distribution Boards as specified in Technical Specification - Electrical, Technical Specification PC183-TS-0809., Single Line Diagrams, Specification Sheets, Specifications and directions of Engineer-in-Charge. All distribution boards incomers shall have phase indication light with MCB. All Distribution boards shall be provided with Aluminium Busbars.
415 V, 12-way, wall / structure mounted Sheet Steel enclosed Industrial Type Hose Proof and weatherproof (IP-55) Lighting Sub Distribution Boards having 1 No. Incoming (100 A 4PMCCB) and 3 nos. feeder circuit of 63A DP RCBO having 12 Nos. outgoing of 32 A DP MCB as indicated in attached SLD along with technical specifications, standards etc. (i.e.4 nos. 32 A DP MCB per circuit).
415 V, 12-way, wall / structure mounted Sheet Steel enclosed Industrial Type Hose Proof and weatherproof (IP-55) Lighting Sub Distribution Boards having 1 No. Incoming (125 A 4PMCCB) and 3 nos. feeder circuit of 63A DP RCBO having 12 Nos. outgoing of 32 A DP MCB as indicated in attached SLD along with technical specifications, standards etc. (i.e.4 nos. 32 A DP MCB per circuit).
415 V, 12-way, wall / structure mounted Sheet Steel enclosed Industrial Type Hose Proof and weatherproof (IP-55) Lighting Sub Distribution Boards having 1 No. Incoming (63 A 4PMCCB) and 3 nos. feeder circuit of 63A DP RCBO having 12 Nos. outgoing of 16 A DP MCB as indicated in attached SLD along with technical specifications, standards etc. (i.e.4 nos. 16 A DP MCB per circuit).
415 V, 9-way, wall / structure mounted Sheet Steel enclosed Industrial Type Hose Proof and weatherproof (IP-55) Lighting Sub Distribution Boards having 1 No. Incoming (63 A 4PMCCB) and 3 nos. feeder circuit of 63A DP RCBO having 9 Nos. outgoing of 16 A DP MCB as indicated in attached SLD along with technical specifications, standards etc.(i.e.3 nos. 16 A DP MCB per circuit).
415V Hose proof and weatherproof industrial type sheet steel enclosed, 18 way Lighting Distribution Board (LSDB) with IP-55 degree of protection having 1 no.(63 A 4PMCCB) and 3 nos. feeder circuit of 63A DP RCBO having 18 nos.16A DP MCBs outgoing as indicated in attached SLD along with technical specifications, standards etc.
415 V, 3 Ph & N, IP55, wall/structure mounted sheet steel enclosed Feeder pillar box consisting of 1 nos. incoming 125A TPN MCCB incomer with RYB indications and 4 nos. 63A TPN MCCB outgoing feeders as indicated in attached SLD for feeder pillar box enclosed with Technical specification EM251-TS-0803.
110 V, wall / structure mounted Sheet Steel enclosed Industrial Type Hose Proof and weatherproof (IP-55) DC Distribution Boards having 1 No. Incoming (32 A DP MCB and ELCB) and 12 Nos. outgoing feeders of 6 A DP DC MCB.
415V Hose proof and weatherproof industrial type sheet steel enclosed, 18 way Lighting Distribution Board (LSDB) with IP-55 degree of protection having 1 no.(125 A 4PMCCB) and 3 nos. feeder circuit of 63A DP RCBO having 12 nos.16A DP MCBs and 6 Nos. 32 A MCBs outgoing as indicated in attached SLD along with technical specifications, standards etc.
415V Hose proof and weatherproof industrial type sheet steel enclosed, 12 way Distribution Board (DB-D1) with IP-55 degree of protection having 1 no.(100 A 4PMCCB) and 8 nos.32A TPN MCBs & 12 Nos. 32 A SP MCBs outgoing as indicated in attached SLD along with technical specifications, standards etc.
415V Hose proof and weatherproof industrial type sheet steel enclosed, 12 way Distribution Board (DB-D2) with IP-55 degree of protection having 1 no.(100 A 4PMCCB) and 12 nos.32A TPN MCBs outgoing as indicated in attached SLD along with technical specifications, standards etc.
415V Hose proof and weatherproof industrial type sheet steel enclosed, 8 way Distribution Board (DB-D3) with IP-55 degree of protection having 1 no.(100 A 4PMCCB) and 4 nos.32A TPN MCBs & & 12 Nos. 32 A SP MCBs outgoing as indicated in attached SLD along with technical specifications, standards etc.
415V Hose proof and weatherproof industrial type sheet steel enclosed, 12 way Distribution Board (DB-D4) with IP-55 degree of protection having 1 no.(100 A 4PMCCB) and 9 nos.32A TPN MCBs & 9 Nos. 32 A SP MCBsoutgoing as indicated in attached SLD along with technical specifications, standards etc.
415V Hose proof and weatherproof industrial type sheet steel enclosed, 8 way Distribution Board (DB-D5) with IP-55 degree of protection having 1 no.(63 A 4PMCCB) and 2 nos.32A TPN MCBs & 18 Nos. 20/32 A SP MCBsoutgoing as indicated in attached SLD along with technical specifications, standards etc.
EMERGENCY PUSH BUTTON STATION FOR TRANSFORMER (Weatherproof)
Supply ,erection,testing and commissioning of Weather Proof push button(OFF) control station of approved make for emergency transformer tripping at field including connection and termination of copper control cable, fabricating, earthing the supporting structure,termination of cables painting the same, including supply & installation of cable glands & plugs for sealing all spare entries including the cost of all labour,tools, materials etc. complete in every respect as per the specification and directions of the Site Engineer / Engineer-in-charge.
LIGHTING
Supply, unloading, storage, handling, transporation within site from store to site of installation, installation, connection, earthing and testing of the following LED fittings, including supply and installation of drop pipes, hooks, JB/TB for looping of fixtures, fittings, fixtures, nuts, bolts, supports, on walls and all other required materials gland, lugs as required etc. as specified in Technical Specification and all hardware for fixing the lighting fittings with ceiling/wall pole including cable glanding, crimping of lugs on cable conductor & connecting cables at fixtures in looping and from lighting DB, earthing, junction boxes, etc., drawings and directions of the Site Engineer including cost of all labour, tools, materials as well as transportation from store to site of erection with all labour and material to make installation complete in all respect. Make of the fittings shall be as per approved make as metioned in Technical specification.
LED Tube light fitting industrial type of approved make suspension mounting suitable for 240V AC as per Technical specification complete with 2x18 W LED fixture with all accessories such as LED lamp/chip, electronic driver, Refelector, Terminal block etc.The fittings shall be provided with suspension accessory / wall mounting bracket depending upon directions by EIC / Site Engineer. The minimum degree of protection shall be IP 20.
LED Tube light fitting industrial type of approved make suspension mounting/wall mounting suitable for 240V AC as per Technical specification complete with 1x20 W LED fixture with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with suspension accessory / wall mounting bracket depending upon directions by EIC / Site Engineer. The minimum degree of protection shall be IP 20.
55 W LED Highbay Light Fixture of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
180 W LED Highbay Light Fixture of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
40 W LED Batton 4 Ft of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
15 W LED Surface Light of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
10 W LED Baton Mirror Light 2 Ft of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
34 W 2 x 2 Luminaire of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
Flame proof Light Fixture 40 W of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
120 W Fllod Light Fixture of approved make suitable for 240V AC as per Technical specification complete with all accessories such as LED lamp/chip, electronic driver, Refelector Terminal block etc etc.. The fittings shall be provided with mounting arrangement as per Site Enginner/ Enginner-in-charge.
Supply,unloading, storage, handling, transporation within site from store to site of installation, installation, connection, testing and commissioning of pre-wired 240V AC,1-Ph, WP outdoor,LED Lighting fixtures including LED lamp with driver and JB for looping of cables of following type which shall be suitable for use in safe area having IP-65 degree of protection complete with all accessories, double compression Ni-plated brass cable glangs & plugs, blanking plugs etc. as specified in Technical specification and all hardware for fixing the lighting fittings with structure/ lighting pole including cable glanding, crimping of lugs on cable conductor & connecting cables at fixtures, earthing, junction boxes, etc. including supply of all connecting materials like clamps, supports, conduits, down rods etc. as required as well as transportation from store to site of erection with all labour and material to make installation complete in all respect as per approved drawings, specifications and directions of Site Enginner / Engineer-in-charge. The rates shall be valid for all mounting heights.
90 W LED Flood light, WP type lighting fixturesof approve make as per technical specification as per technical specification with led lamp/chip, driver etc. complete with increased safety cable glands, plug suitable for 3 X 2.5mm2 XLPE-A-PVC cable and stopping plug.
60 W LED Flood light, WP type lighting fixturesof approve make as per technical specification as per technical specification with led lamp/chip, driver etc. complete with increased safety cable glands, plug suitable for 3 X 2.5mm2 XLPE-A-PVC cable and stopping plug.
45 W LED Flood light, WP type lighting fixturesof approve make as per technical specification with led lamp/chip, driver etc. complete with increased safety cable glands, plug suitable for 3 X 2.5mm2 XLPE-A-PVC cable and stopping plug.
Bulkhead type LED light fitting type of approved make wall mounting suitable for 110V DC as per Technical specification complete with 1 x 9 W LED fixture with all accessories such as LED lamp/chip, electronic driver , terminal block, Refelector etc.. The fittings shall be provided with suspension accessory / wall mounting bracket depending upon directions by EIC / Site Engineer. The minimum degree of protection shall IP 65.
Wiring
Point Wiring : One Light / Fan / Exhaust Fan Point shall controlled by one switch . Supply and Providing Point Wiring system for primary light point/ceiling fan point/exhaust fan point/ call bell point/light plug point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size. Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V grade with 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch, sockets, fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/ Wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate, board, switch, socket etc shall be as per approved Make .(Actual nos. shall be decided at site).
Point Wiring : TWO Light / Fan / Exhaust Fan Point shall controlled by one switch. Supply and Providing Point Wiring system for primary light point/ceiling fan point/exhaust fan point/ call bell point/light plug point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size. Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V grade with 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch,sockets,fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate,board switch, socket etc shall be as per approved Make. (Actual nos. shall be decided at site).
Point Wiring : THREE Light / Fan /Exhaust Fan Point shall controlled by one switch. Supply and Providing Point Wiring system for primary light point/ceiling fan point/exhaust fan point/ call bell point/light plug point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size. Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V grade with 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch,sockets,fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate,board switch, socket etc shall be as per approved Make. (Actual nos. shall be decided at site).
Point Wiring : TWIN controlled Light Point. Supply and Providing Point Wiring system for twin controlled lighting point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size.Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V grade with 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch, sockets, fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate, board switch, socket etc shall be as per approved Make. (Actual nos. shall be decided at site).
Point Wiring : Plug Point Supply and Providing Point Wiring system for 6A Plug points with single core multi stranded PVC insulated unsheathed copper conductor fire retardant wires of 1100V grade in recessed PVC conduit including providing and fixing PVC conduits of required size complete with accessories such as bends,JB, Pull Boxes etc with plate, switches,sockets,screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable sizes, embedded in wall, concealed and flush with walls including cutting and refilling the chases/ Wall etc and inclusive of 14 SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All Modular type switch & socket shall be of approved make.6 Amp 6 pin socket outlet with 6A switch mounted side by side with 2x2.5 sq.mm PVC copper wire with 14 SWG bare copper earth wire.(Actual nos. shall be decided at site).
Point Wiring : Secondary Plug Point from Primary Plug Point Supply and Providing Point Wiring system for 6A Plug points with single core multi stranded PVC insulated unsheathed copper conductor fire retardant wires of 1100V grade in recessed PVC conduit including providing and fixing PVC conduits of required size complete with accessories such as bends,JB, Pull Boxes etc with plate, switches,sockets,screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable sizes, embedded in wall, concealed and flush with walls including cutting and refilling the chases/ Wall etc and inclusive of 14 SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All Modular type switch & socket shall be of approved make.6 Amp 6 pin socket outlet with 6A switch mounted side by side with 2x2.5 sq.mm PVC copper wire with 14 SWG bare copper earth wire.(Actual nos. shall be decided at site).
Point Wiring : Power Plug Point Supply and Providing Point Wiring system for 16A /6A power plug point with following sizes PVC insulated unsheathed single core multi stranded copper conductor, fire retardant wires of 1100V grade in recessed PVC conduits of required size complete with accessories such as bends,JB,Pull boxes etc with plate switches,sockets,screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable size, embedded in wall concealed and flush with walls including cutting and refilling the chases/Wall etc, and inclusive of 14SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All modular type switch & socket shall be of approved make.16A, 6 Pin socket outlet with 16A switch mounted side by side with 2x4 sq.mm PVC copper wire with 14 SWG bare copper earth wire as an independent circuit from DB. (Actual nos. shall be decided at site).
Point Wiring : Secondary Power Plug Point from Primary Power Plug Point Supply and Providing Point Wiring system for 16A /6A power plug point with following sizes PVC insulated unsheathed single core multi stranded copper conductor, fire retardant wires of 1100V grade in recessed PVC conduits of required size complete with accessories such as bends, JB, Pull boxes etc with plate switches, sockets, screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable size, embedded in wall concealed and flush with walls including cutting and refilling the chases/Wall etc, and inclusive of 14SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All modular type switch & socket shall be of approved make.16A, 6 Pin socket outlet with 16A switch mounted side by side with 2x4 sq.mm PVC copper wire with 14 SWG bare copper earth wire as an independent circuit from DB. Two nos.power plug point shall be looped from one primary plug point.
Point Wiring : A.C. Point Supply and Providing Point Wiring system for 32A Industrial socket point (A.C. Point) with 2x4 sq.mm PVC insulated copper conductor FRLS cable in recessed PVC conduit along with 1x4 sq.mm. PVC insulated FRLS cable for earthing I/C, Providing & fixing 25A plug & socket unit complete with 32A DP MCB and 32A plug top including GI Box to be mounted on modular plate complete with connections, testing & commissioning etc (separate circuit for each point) : 32A DP MCB with Sockets for 1.5T AC
Supply, hanging, fixing, connecting 3-blade ceiling fan including provision of cable/wire from ceiling rose or connector to fan including supply and fixing hexagonal fan hook with 12 mm dia. MS rod bend to shape as reqd.
1400 mm sweep
1200 mm sweep
600 mm sweep
Supply, Installation, Testing & Commissioning of following single phase wall fan and exhaust fan with guards / louvres, along with necessary brackets, all required civil works, making good the walls after fixing the fans etc.
380 mm sweep heavy duty exhaust fan
Corrosion proof, flameproof 300mm sweep heavy duty exhaust fan for battery room
WP SWITCH CUM SOCKET :
Supply, erection, installation, testing and commissioning of flameproof/weatherproof switch cum socket/welding receptacle having IP65 protection of approved makes to be installed on walls, columns, structures, including handling, storage, transporation from store to site of installation, supply & installation of double compression cable glands, suitable lugs & WP/flame proof plugs for sealing all spare entries etc., including connection and termination of all power cables, earthing wire and conduits, etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect
415 V, 125 A switch cum socket with plug (Weatherproof)
415V, 63A, Switch & Socket with Plug (No. of Pins 3P +N+ E), (Weather proof)
415 V, 32 A switch cum socket with plug (Weatherproof)
250 V, 16 A switch cum socket with plug (Weatherproof)
EARTHING AND LIGHTNING PROTECTION
Supply, Installation, Testing & Commissioning of 100 NB, 3.8 M long G.I. pipe Earth Electrode in Earth pit as per PDS attached with TS Including handling, transportation to Erection site, Excavation of Earth pit in all types of soil, back filling of pit with common salt, charcoal / coke and loose Earth after installation of Electrode there in, removal of surplus Earth away from Erection site, consolidation of loose Earth on back filled pit, making of bricks work, Inspection chamber on back filled pit and cover of RCC, there of complete with lifting hook, fixing & connecting inside the chamber of G.I. Earth bracket and other accessories of the Earth Electrode, painting of Earth pit No. and Earthing symbol on the cover, supply of salt, charcoal / coke, bricks, sand, cement, stone chips, reinforcement rods, lifting hook, necessary stainless steel hardware, paints etc. (Excluding supply of G.I. Earth Electrode &its accessories), all works, labour & materials complete as per Drawings, specifications, code & standards and direction of consultant / owner.
Supply, Installation & Commissioning of GI Earth Bus bars (size: 390x50x12mm thick) as per PDS attached with TS Including handling, transportation, drilling of necessary holes/enlargement existing holes as required; all associated work for fixing the Bus bars in position e.g. cutting, leveling, aligning, chipping, grouting, welding bolting etc.; making good of broken/chipped portion on walls /columns by cement plastering. Supply of all necessary hardware (GI), paints, civil masonry materials etc. all work,labour complete as per drawings, specifications, codes and standards and directions of consultant /owner.Hot dip galvanized GI earth bus bar of size 390 x 50 x 12 thick (with min. coating 610gm/sq.m of zinc) with fixing materials as per specifications and direction of Site Engineer / Engineer-in charge
Supplying and laying of the stainless steel SS-304 air terminations, base plate & clamping of down Conductor complete with base plate, concrete coping fixing accessories and clamping with down Conductor
HT CABLE JOINT (11 KV)
Supply, Making straight-through joint on 11 KV Aluminium XLPE insulated armoured screened cable, including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem, materials, labour, tools and tackles, consumables etc., as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. For cables of size upto 3 core x 400 sq. mm Note: Lugs supplied with HT cable joint shall be Al/Cu/Bimetallic (as per cable/bus bar type).
11KV (UE) grade XLPE insulated, 3Cx240 (Al)
HT Cable Termination (11 /3.3KV):
11KV (UE) grade XLPE insulated, 3Cx240 (Al)
11KV (UE) grade XLPE insulated, 3Cx400 (Al)
3.3KV (UE) grade XLPE insulated, 3Cx240 (Al)
GI PIPE
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge.
HDPE PIPE
Supply, laying of HDPE 32mm dia 3mm thick as per IS 7238 grade 80, Pipe in trenches / walls / concrete structure / panels etc. as per specifications and drawings & blowing / laying of Optical Fibre Cable in HDPE pipe, carrying out end to end testing of laid Optical fibre cables by taking OTDR traces and submitting the OTDR trace printouts to Site Engineer / Engineer-in-charge. The job includes the supply and installation of required materials such as fixing clamps, screws, tags etc. as required to complete the job in all respects as per drawings and directions of Site Engineer / Engineer-in-charge including cost of all labour, tools & tackles, test instruments, materials etc. The job includes handing over the tested cables to the Telecom / Control System Works Contractor in commissioning of Local Area Network.
Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push button control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete and as per specifications and directions of site engineer/Engineer-in-Charge.
Supply, Fabrication & installation of 2 mm thick Al sheet for rain protective hood for outdoor equipment e.g. motors, switch sockets, junction boxes etc.
Supply, Fabrication and Installation of 8mm thick chequered plate in flooring, steps, covers over cable trenches in switch board room, painting with one coats of bitumen paint in the 50% thinner with two coats of black bitumen paints including supply of all consumables and paints.
WP JUNCTION BOX
Supply, erection, installation, testing and commissioning of flameproof & weather proof 240 V, 25A, junction box for providing cable termination, including connection and termination of earthing wire and conduits etc., including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect.
240V, 16A, 4 way junction box with 4 cable entries (4 x 3/4") at bottom & 20 nos. terminals.
Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc., as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Supply laying, sperading of Class B 9”x 4.25” x 3” bricks for cable trenches soling with sand filling in the interstices, in cable trenches for protection including the cost of all brick and sand, labour, load and lift charges, tools and tackles etc., as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, backfilling, materials, labour, tools and tackles, consumables etc., as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
EXCAVATION AND BACK FILLING
Excavation of 1700 mtr. length x 400/600 mm wide x 1200 mm deep a for laying of cables including disposal of excavated earth, lead up to 100 mtrs. and lift up to 1.5 mtrs., disposed earth to be levelled and neatly dressed
Back filling with excavated earth in trench including consolidating each deposited layer by ramming, dressing etc.
TERMINATION OF CABLES (LT)
End termination and subsequent testing of XLPE insulated single core/ multi core armoured cables of 1.1KV grade, Al/ Cu cable.,including supply of double compression rolled aluminium cable glands, suitable lugs (Al/Cu/Bimetallic)and lugs of all phases & neutral , all labour and consumable materials to make installation complete in all respect. Modification in existing switch board for accomodating the proposed cables. The rate shall include drilling, taping of cable insulation, crimping of lugs to the conductor, connection of the lugs to equipment terminal, supply and fixing of supports & clamps for cables, G.I. nuts, screws, bolts, washers and other necessary hardware, PVC tape of required grade for taping, making cable entries dust and vermin proof, earthing etc. as per instruction of manufacturer, approved drawings, specifications and directions of engineer-in-charge.
3.5C x 630 mm2 (Al)
3.5C x 400 mm2 (Al)
3.5C x 300 mm2 (Al)
3.5C x 240 mm2 (Al)
3.5C x 150 mm2 (Al)
3.5C x 120 mm2 (Al)
3.5C x 70 mm2 (Al)
3.5C x 50 mm2 (Al)
3.5C x 35 mm2 (Al)
3.5C x 25 mm2 (Al)
4C x 35 mm2 (Al)
4C x 25 mm2 (Al)
4C x 16 mm2 (Al)
3C x 120 mm2 (Al)
3C x 70 mm2 (Al)
3C x 50 mm2 (Al)
3C x 35 mm2 (Al)
3C x 25 mm2 (Al)
3C x 10 mm2 (Cu)
3C x 6 mm2 (Cu)
3C x 4 mm2 (Cu)
3C x 2.5 mm2 (Cu)
5C x 2.5 mm2 (Cu)
7C x 2.5 mm2 (Cu)
12C x 2.5 mm2 (Cu)
19C x 2.5 mm2 (Cu)
1Cx185 mm2 (Al) Unarmoured
1Cx16 mm2 (Al) Unarmoured
6 fiber, multi mode optical fiber cable along with all accessories like reciever, converter, transmiitor, patch card etc
Supply, Installation , testing and commissioning of 240V, 1-Ph, Wall Mounting Fans / Ceiling Fans (with Electronic Regulator) / Man Cooler Fans etc on wall / Ceiling / Steel Structure including supply, fabricating and grouting of MS Frame / Hooks and other hardware etc.
400 mm sweep heavy duty wall fan with string controlled regulator & rotation.
PUBLIC ADDRESS SYSTEM
Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturer's works, packing, delivery at site,Unloading, Handling, Storage, transportaion within site, Assembly and Erection,testing, Commissioning & guarantee test for final acceptance of Public Address System of the following, including supply of commissioning spares, special tools and tackles, all required installation material ,& Testing and commissioning at site ,documentation as per the enclosed Technical specification and other codes and standards attached or referred. Note:Installation & Commissioing shall be executed by PA system OEM.
WP (IP-65) Wall mounted/structure mounted FCS with 2 dual positions key with keypad and built-in 25W booster amplifier.
FLP & WP (IP-65) FCS with 2 dual positions key with keypad and built-in 25W booster amplifier for Gas Gr. IIC
WP (IP-65) 25W/12.5 paging loud speaker for FCS.
WP (IP-65) 15W paging loud speaker for FCS box type for installation in Substation/Building
FLP, WP (IP-65) 25W paging loud speaker for FCS suitable for Gas Gr. IIC .
FRP Acoustic Hood for Sound Protection.
FRP Glass Moulded Full Canopy for rain protection.
Cat-06 LAN cable in 16mm / 25mm / 32mm PVC conduit etc
Outdoor WP IP65 Junction box for PA system with all accessories
50 Pair X 0.8 mm Armored Cable with FRLS outer sheath overall un-screened cable from owner's exchange to PA Junction box
5 Pair X 0.8 mm Armored Cable with FRLS outer sheath overall un-screened cable for both Loudspeaker and Field call stations
Erection, testing and commssioing of complete PA system including MCS ,FCS, Hooters, canopy, accoustic hood,paging speaker,laying and termination of all power and signal cables including supply of consumeable, glands, lugs etc and interface and seamless integration with other PA system of plant.
WBM ROAD / CONCRETE BREAKING : WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
415 V MV BUS DUCT
Supply of 415 V Bus Duct as perspecified in data sheets, Technical Specification - Electrical, Technical Specification Doc. No. PC183-TS-0807, etc. attached with the NIT.
3200 A, 415 V, 50 Hz, 50kA for 1 second, Non-Segregated High Conductivity Copper TPN Bus Duct of 12.5 Mtr. length (From Transformer Flange Centre Line to Panel Flange Centre Line) including 2 nos. horizontal bends and 3 nos. vertical bends between 11 kV / 0.433 kV, 2 MVA Transformers and PMCC-1 with associated equipments and all other accessories as per enclosed Main Substation Equipment Layout , Technical Specification - Electrical, Technical Specification Doc. No. PC183-TS-0807, etc. attached with the NIT.
Supply,Installation, testing and commissioning of 240V room lighting boards along with required wiring (concealed in PVC conduit / on wall) having following features:-
1 no. Switch & Socket for 6 / 16 Amp 2 nos. 6 Amp switches with regulators for ceiling Fan 2 nos. 6 Amp switches for lighting
1 no. Switch & Socket for 6 / 16 Amp 5 nos. 6 Amp switches for lighting
1 no. Switch & Socket for 6 / 16 Amp
MISCELLANEOUS ITEMS
Supply and Fixing of Caution boards / dangers boards written in ENGLISH & HINDI of the following voltages.
Supply andFixing of shock treatment chart written in English and Local language duly framed and approved by engineer-in-charge.
Supply andFixing of Do & Don’t chart as per Indian Electricity Rules in Aluminum frame with glass
Supply and Fixing of S/S Single Line Diagram in Aluminum frame with glass.
Supply and Fixing of CPR (CARDIO PULMONARY RESUSCITATION) Charts.
Supply andFixing of High Voltage danger signage (Skull & bones).
Supply and Fixing of Exit Route / Emergency Exit Route Signage.
Supply and Fixing of First aid boxes.
Supplying the following Equipment as per directions of Site Engineer / Engineer-in-Charge
RUBBER HAND GLOVES : Rubber hand gloves suitable for 11/3.3 KV operation with ISI mark.
Supply of 11 KV Discharge Rod
INSULATING MATS:
Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elastomer mats as per specifications.
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B)
Supply and fixing of of fully charged portable CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 2878 latest)
DRY TYPE LIGHTING TRANSFORMER
Supply, storage at site, Transporation from store to site of installation, Handling, Installation, Testing and Commissioning of Dry Type Lighting Transformers including power and control cable termination, fabrication of base foundation, placing in fabrication of base foundation channel, position on MS base channel/flat, assembly of all accessories, supply & fixing of required no. & size of double compression nickelplated brass/rolled Al cable glands & suitable lugs (Aluminium/copper/Bi metallic), connection and termination of all power and control cables all labour and material complete as per drawings/specification and direction of the lighting transformer manufacturer with all accessories, as specified in Technical SpecificationPC183-TS-0829
11 kV PANEL : Supply, Handling, Installation, Testing and Commissioning of Incoming cum Outgoing 11kV 3Ph 50Hz 31.5kA 1250 A VCB Panel complete with metering and protection system free standing floor mounting cubical type as per SLD & Specification Sheet and Technical specification - Electrical System (Doc No. PC183-TS-0805) and SLD No. PC183-7411-0985E including transportation from owner’s stores, dressing of foundation, placing in position on MS base channel/flat, assembly of all accessories supplied loose, all labour and material complete as per drawings/specification and direction of the manufacturer.
SECTION A : INSTRUMENT WORKS (SUPPLY )
CCTV for OSBL facilites and Survillance Purpose of TFL Fertilizer complex : Design , Engineering & Supply
CCTV Complete system for whole fertiliser complex as per attached specification - Bidder shall engineering , supply, install, test and commissioning the ONVIF-IP based Closed circuit television (CCTV) Surveillance System,Complete CCTV System with all accessories like Cameras, power supply , JB , LIU, media convertor, OFC convertor, 22” LED workstation , server, VMS ,NAS for 365 days storage , one LED 72” ceiling mounted with 100 windows , software , license , surveillance software , analytical software , all cables, all mounting accessories , poles , civil works etc. (A at the TFL fertlizer complex . The purpose of the CCTV System is to monitor the facility operations & security surveillance from control room / Security room & Admin building to keep eye on facility covering Main gate entry /exit ,material gate exit / entry and other area of importance to the daily running of the complex by installing cameras to monitor resulting to enhancement in the Operational & Safety needs. It is intended to install CCTV system to track the Material movement, Recognition of persons and objects including vehicles through high quality images in and outside the plant by Security. The recording of the scene can be used in investigation, recreating the scene and establishing the truth.
Fixed Perimeter 1080p HD IP outdoor Cameras IP66 housing with Day/night fixed camera with advanced video analytics, Min 75 Mtrs IR range , Camera with 1/3" or better CMOS , 1920 (H) X 1080 (V); 2 MP or better , Inbulit Min 128 GB or higher GB SD Card Storage for local recording etc. as per attached specification
1080p HD IP Indoor / outdoor PTZ Cameras with 1/3" or better progressive scan Exmor CMOS , 1920 (H) X 1080 (V); 2 MP or better, 30 X optical Zoom (4.3 mm -129 mm) , 4X Digital Zoom,
Supply of Intelligent video operation, control, management, recording,processing software & Advanced Analytics Software for Perimeter Survillance as per specifications and instructions of Engineer in charge. This shall include 128 camera recording license and 128viewing license per site.
Supply of all erection and installation material like Industrial grade layer ethernet Switch . OFC accessories like 12/24 port LIU, splice trays, loaded adaptor and blank plates, UTP and optical patch cords, pigtails, FRP junction box, FRP cable trays, FRP canopy ,steel structure for installation , Octagonal pole ( 10/8/6 meter) power supply , media convertor, armoured power cables , communication cable ,12 core single mode steel armoured optical fibre cable etc. in all respect as per specifications and instructions of Engineer in charge. Its bidder responsibility to consider BOQ as per best engineering pracrice and complete in all respect to full fill tender specification mentioned elsewhere .
Complete EPBAX system, telephone network with telephone set , LAN Network and LAN system of Buildings of Fertililser complex : Design ,Engineering, Supply & Interface with other exchanges including main exchange
EPBAX exchange with 200 extensions lines and all the equipment shall conform with all relevant and the latest edition of Indian, International, OISD and CCITT/ ITU standards using field proven microprocessor based design techniques for all processing and control functions. The exchange shall be based on a robust, reliable, virus protected, IP based platform for connecting IP phones, Digital phones as well as Analog extensions as specified in technical specification
IP Phone with built in camera & TFT LCD display for video conferencing as well as capable to connect an external IP camera
Standard IP Phone with TFT LCD display with optional expansion module
IP Based Basic desktop phones
Telephone Cables 20 pair
Telephone Cables 5 pair
LAN cable
LAN items as per specification as usered mentioned
SUPPLY of impulse piping inclusive of pipe fittings, flanges , gasket , nut & bolts, Tube & tube fittings, Instrument valves, condensate pot,Syphon , Gauge valve , Gauge saver , Snubber etc. as per attached Hook-Ups drawing.
2480-MALE CONNECTOR, 3/4"NPTM x 1/2" OD, A182 F316
2464-MALE CONNECTOR , 1/2' NPTM x 1/2" OD, A182 F316
2467-MALE CONNECTOR , 1/2"NPTM X 1/4" OD, A182 F316
2466-MALE CONNECTOR , 1/4" NPTM X 1/4" OD, A182 F316
2473-FEMALE CONNECTOR , 1/2" NPTF X 1/2" OD, A182 F316
2563-LOCK NUT WITH PLUG , 1/2" OD,6000#, A182 F316
2506-STRAIGHT CONNECTOR , 1/2"OD x 1/2"OD, A182 F316
2501-STRAIGHT CONNECTOR, 1/4" OD X 1/4" OD, A182 F316
2460-SEAMLESS TUBE , 1 /2" x 0.065" THK, A182 F316
2457-SEAMLESS TUBE , 1/2" OD X 1MM THK, A269 TP316
2446-SEAMLESS TUBE , 1/4" OD X 1MM THK, A269 TP316
2266-GLOBE VALVE , 1/2" NPTFx1/2" NPTF, 6000#, A182 F316
2515-UNION TEE , 1/2" x 1/2" x 1/2" OD, A182 F316
SUPPLY MATERIAL FOR STRUCTRAL WORK & FEBRICATION FOR INSTRUMENT ITEMS LIKE TRAY SUPPORT, MOUNTING FRAMES FOR INSTRUMENTS, BASE FRAMES,CANOPY FOR JB , CANOPY FOR INSTRUMENT, ANY OTHER REQUIRED FOR SUPPORTING INSTRUMENT ITEMS ALONGWITH CANOPY
50 x 50 x 6THK ANGLE MS
100 x 50 x 6THK CHANNEL MS
FOUNDATION BOLTS, NUTS & WASHER 10MM X 150L MS
COVER PLATE 4 MMTHK MS
RIBS (PLATE) 250 X 250 X 6 THK MS PLATE
BASE PLATE 250 X 250 X 6 THK MS PLATE
2” MS PIPE FOR STAND PIPE, MEDIUM, AS PER IS:1239
SUPPLY OF FRP JUNCTION BOX , CABLE GLANDS , PLUG AS PER TECHNICAL SPECIFICATION AND AS MENTIONED IN TENDER ELSEWHERE
Junction Box, Please refer attached spec sheet for details
Cable Glands, M20 SS316 Cable Gland Double Compression Exd suitable for Cable OD "14.5+/- 2mm" with locknut & PVC Hoods(All JBs shall be plugged with SS Plug)
Cable Glands, M32 SS316 Cable Gland Double Compression Exd suitable for Cable OD "28.8+/- 2mm" with locknut & PVC Hoods (Both end JB & Control Room) (All JBs shall be plugged with SS Plug)
Cable Glands, M32 SS316 Cable Gland Double Compression Exd suitable for Cable OD "28.8+/- 2mm" with locknut & PVC Hoods (LCP & Control Room) (All JBs shall be plugged with SS Plug By Default.)
Cable Glands, M32 SS316 Cable Gland Double Compression Exd suitable for Cable OD "28.8+/- 2mm" with locknut & PVC Hoods (MCC & Control Room) ((All JBs shall be plugged with SS Plug By Default.)
SUPPLY of FRP PERFORATED CABLE TRAY with cover and SS installation accessories including joining, cutting, bendind, supporting etc. (Pls refer annex for details )
FRP CableTray ( Perforated) with flat Cover , 2500 x 600 x 150 mm,4mm thk
FRP CableTray (Perforated) with Cover, 2500 x 300 x 55 mm,4mm thk
FRP CableTray (Perforated), 2500 x 200 x 55 mm,4mm thk
FRP CableTray (Perforated), 2500 x 100 x 55 mm.4mm thk
FRP CableTray (Perforated), 2500 x 50 x 55 mm.4mm thk
FRPInside 90 Deg Vertical Bend with Cover ( for 600mm ladder), 600 mm (Bending Radius 600mm)
FRP Outside 90 Deg Vertical Bend with Cover ( for 600mm ), 600 mm(Bending Radius 600mm)
FRPHorizontal 90 Deg Bend with cover ( for 600mm ), 600 mm(Bending Radius 600mm)
FRP Horizontal TEE ladder fitting with Cover ( for 600mm ), 600 mm(Bending Radius 600mm)
FRP Horizontal Cross fitting with Cover ( for 600mm ), 600 mm(Bending Radius 600mm)
Reducer 600 to 300,
All SS mounting & installation material and other items to complete above cable tray laying ,
Canopy & Accessories ( Complete Canopy to cover instrument items properly), Pls refer Attached Spec Sheet
Supply of Instrumentation cable, Signal & Control, Power cable,OFC and T/c extension Cables data sheets/technical specification cover requirement for design, engineering, manufacturing, assembly, and supply, documentation, testing at manufacture’s works, packing and shipping of the Signal & Control , Power cable and T/c extension Cables .
12P x 1.5 SQMM
01P x 1.5 SQMM
06P x 1.5 SQMM
08T x 1.5 SQMM
01T x 1.5 SQMM
01P X 16 AWG
03C X 2.5 SQMM
02C X 1.5 SQMM shielded Modbus cable
OFC- Single Mode 8 Fiber
1C x 10 SQMM, Tinned Cu conductors min 10 sq.mm, Green outer sheath
SUPPLY of AIR DISTRIBUTION POT SS304
ADP - 10 TAKE OFFS
Deleted
Deleted
Deleted
Supply of instruments with all mounting accessories and license /software including Third Party Inspection
Supply of Pressure Gauge (PG) as per the technical specifications attached in the Tender. , 0 - 10 kg/cm2
Supply of Pressure Gauge (PG) as per the technical specifications attached in the Tender. , 0 - 20 kg/cm2
Pressure Transmitters with 2 way manifolds and Cable glands ; Smart type; accuracy 0.05% or better Installation: 2" Pipe Mounted including spares as Per Detailed Spec., 0-1 KG/CM2
Pressure Transmitters with 2 way manifolds and Cable glands , Smart type; accuracy 0.05% or better Installation: 2" Pipe Mounted including spares as Per Detailed Spec., 0-10 KG/CM2
Pressure Transmitters with 2 way manifolds and Cable glands, Smart type; accuracy 0.05% or better Installation: 2" Pipe Mounted including spares as Per Detailed Spec., 0-50 KG/CM2
Pressure Transmitters with 2 way manifolds and Cable glands , Smart type; accuracy 0.05% or better Installation: 2" Pipe Mounted including spares as Per Detailed Spec., 0-250 KG/CM2
Differential Pressure Transmitter with 3 way manifold valves and Cable Glands,Smart type; accuracy 0.050% or better including spares as Per Detailed Spec., 0-500 MMH2O
Differential Pressure Transmitter with 3 way manifold valves and Cable Glands,Smart type; accuracy 0.050% or better including spares as Per Detailed Spec., 0-2500MMH2O
Differential Pressure Transmitter with 3 way manifold valves and Cable Glands,Smart type; accuracy 0.050% or better including spares as Per Detailed Spec., 0-1200 MMH2O
Differential Pressure Transmitter with 3 way manifold valves and Cable Glands,Smart type; accuracy 0.050% or better including spares as Per Detailed Spec., 0-2000 MMH2O
FE-101,Flow Orifice , tappings 1set +1 set spare , flange Size ,rating & matl. 8" 300#RF, A105, plate material SS 316 ,2 Nos Gasket as Spare as per detailed Spec., 0-300 m3/hr
FE-102,Flow Orifice , tappings 1set +1 set spare , flange Size ,rating & matl. 8" 300#RF, A105, plate material SS 316 ,2 Nos Gasket as Spare as per detailed Spec., 0-300 m3/hr
FE-001,Flow Orifice , tappings 1set +1 set spare , flange Size ,rating & matl. 3" 300#RF, A105, plate material SS 316 ,2 Nos Gasket as Spare as per detailed Spec., 0-300 m3/hr
PCV-01 Spring loaded Self actuating pressure regulating globe valve for 3" ,150# RF line with its seat ,plug material SS316+Stellited,along with gasket ,spring set and packing seat as pares,
SECTION B 1 - INSTRUMENT WORKS (ERECTION/INSTALLATION OF INSTRUMENTS AS PER ATTACHED HOOK-UP DRAWING,INSTALLATION DRAWING. CABLE LAYING AND CABLE TRAY LAYING, INSTALLATION OF JUNCTION BOX , LOCAL CONTROL PANEL, SIGNAL TERMINATION GLANDING FOR ELECTROHYDRAULIC CONTROL VALVES ETC. , LOOP CHECKING , TESTING OF TRANSMITTERS / INSTRUMENTS ETC AS BELOW.
BRIEF SCOPE OF INST WORK AND SERVICES BUT NOT TO LIMITED 1) The BIDDER shall be responsible for the calibration & testing,installation, glanding ,termination, commissioning of the complete instrumentation and controls as defined in this Tender. In general, the scope of work and services of the BIDDER shall include the but not limited to; a). Taking delivery from the warehouse or from the places of storage OR BIDDER's alloted yard , tansportation, handling, storage, unpacking, assorting physical checking and testing of instruments, panels / cabinets, instrument accessories cables, junction boxes, cable glands, cable trays ducts and erection materials etc. b).Scope includes raising of store requisitions to OWNER/PDIL( if required) on prescribed formats for issue of free-issue-materials (FIMs)if any and maintaining record of the material issued at its site office. All works including Field fabrication / erection shall be done strictly in accordance with OWNER/PDIL specifications and standards. c).Scope includes return of Leftover free issue material to OWNER/PDIL with suitable return notes. d).BIDDER shall supply all required tools, tackels, equipment, skilled & unskilled manpower,managerial staff, consumables & whatever else may be necessary for competing the job within the project schedule. e) If it is necessary to maintain the project schedule, BIDDER shall extend the working hours,working days & whatever else may be necessary for maintaing the project schedule without any cost & time implication to purchaer/end user. f). BIDDER will be responsible for the protection & maintenance (both at BIDDER's stores and/or in the field) of instruments & accessories issued to him. Supply of the materials necessary for the said protection and/or maintenance is in BIDDER's scope. g).BIDDER shall inform site incharge for any material damaged and/or missing during erection. if it is proved that said material is damaged and/or missing by the BIDDER, the cost of the same shall charged to him. h) Transportation of unserviceable Instrument Scrap as defined in this tender. i). All the instruments & systems installed by the BIDDER as per contract shall be subject to inspection,checking, calibration & testing to prove their operational fitness.Testing & calibration shall be done by the BIDDER, all the required tools, tackels, calibration instruments,LAB, qualified skilled manpower for conducting these tests shall be provided by the BIDDER. j).Testing & calibration may be witnessed by representative OWNER/PDIL and/or manufacturer's representative.
2) LETTER WRITING : LETTER WRITING FOR ALPHA-NUMERIC TAGGING ( WITH SYNTHETIC ENAMEL). :- Letter writing of different sizes on Instrument Panels/misc. Instruments/ Equipments with synthetic enamel paints (Asian/ Jonson & Nicolson/ Berger /Nerolac Make) suitable for a temp. of 100 degree Celsius for writing of letters, figures etc. Job includes cleaning of surface on panels/instruments/misc. instruments etc. All complete with labour and materials as per drawings, specifications, Name plate schedule and directions of Engineer-in-Charge. (Supply of paints is in BIDDER scope). 3) PAINTING :- SPRAY PAINTING (PAINT IS IN BIDDER’S SCOPE) :- Cleaning of surface, rust, removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application of enamel paint by spray painting on instrumentation panels/instruments or any other metallic surface with one coat of ready mixed primer and two coats of approved quality/ apcolite Asian synthetic enamel paint including supply of paint suitable for a temp. of 100 degree C. All complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge. 4) bidder has topmake necessary arrangments for cable entry to control room all the civil, welding works , consumables, tools & tackles , manpower etc shall be in bidders scope.no seperate rate shall be allowded.
Erection/installation of electronic transmitter including unpacking, pre checking, calibration, termination, loop checking & commissioning. : [Erection material shall be supplied by BIDDER]. As installation drawing.
The job includes the following: Shifting of new instrument with its accessories from store to work site.Installation of pressure transmitters( Drilling of blind flanges of Vessels if requiredShall also be in the scope of BIDDER) with its accessories.Glanding, ferruling and termination of the signal cable of the instruments wherever required, including aluminium tagging, supply of ferrule, lugs and aluminium tag is in BIDDER’s scope of supply
Fabrication, installation and grouting of small supports for instrument . Laying and erection of perforated tray / angle iron for neatly laying of impulse line of the instrument.
All above jobs are inclusive of supply of all sorts of erection materials (including clamps, nuts bolts etc.) grouting material (cement, concrete, sand etc.) and consumables excepting the supply of Pipes, Pipe Fittings, Perforated Tray, Structural Material and Instruments. Hydraulic testing of manifold.
Painting of all erected structural items (excluding impulse line) inclusive supply of paint (Paint make shall be Asian/Berger/Nerolac).
Necessary skilled & unskilled manpower, supervision, tools & tackles, transporting vehicle, supply of all sorts of consumables shall be in BIDDER’s scope. The job shall be carried out as per specification and direction of Engineer-in-charge.
Pressure Gauge erection / installation (Including drilling of blind flange where ever required, impulse piping including staem tracing, glanding, and termination, erection of Statction & Supports Canopy etc)
PressureGauger -Hydrotest, PMI, DP tests
Pressure Gauge functional check, loop checking
Pressure Gauge calibration
Pressure transmitter erection / installation (Including drilling of blind flange where ever required, impulse piping including staem tracing, glanding, and termination, erection of Statction & Supports Canopy etc)
Pressure transmitter -Hydrotest, PMI, DP tests
Pressure transmitter functional check, loop checking
Pressure transmitter calibration
Differential pressure transmitter (FT, PDT) Erection / installation (Including impulse piping including staem tracing, glanding, and termination, erection of Statction & Supports Canopy etc)
Differential Pressure transmitter (FT, PDT) -Hydrotest, PMI, DP tests
Differential pressure transmitter (FT, PDT) -Functional check, loop checking
Differential pressure transmitter (FT, PDT) - Calibration
Differential pressure transmitter (LT) erection / installation (Including impulse piping including staem tracing, glanding, and termination, erection of Statction & Supports Canopy etc)
Differential Pressure transmitter (LT)-Hydrotest, PMI, DP tests
Differential pressure transmitter (LT) functional check, loop checking
Differential pressure transmitter (LT) calibration
Temperature transmitter Erection / installation( (Including glanding, and termination, erection of Statction & supports Canopy etc)
Temperature transmitter Functional check, loop checking
Temperature transmitter Calibration
Installation of level transmitter of all types (LT) ( except DP type)- Erection / installation (glanding, and termination, erection of Statction & Supports Canopy etc if any)
Installation of level transmitter of all types (LT) ( except DP type)- Functional check, loop checking
Installation of level transmitter of all types (LT) ( except DP type)- Calibration
Level Switch (LS)- Erection / installation (glanding, and termination, erection of Statction & Supports Canopy etc if any)
Level Switch (LS)- Functional check, loop checking
Level Switch (LS)- Calibration
Rotameter/all other types of flow meters except Mag flow meter -Erection / installation (glanding, and termination, erection of Statction & Supports Canopy etc if any)
Rotameter/all other types of flow meters except Mag flow meter - Functional check, loop checking
Rotameter/all other types of flow meters except Mag flow meter - Calibration
Glanding/Termination/ferruling of instrument /switches etc already erected by package vendor ( this covers skid mounted instruments/instruments already erected by vendor and provided at site )
Loop Checking of Package items which are not erected by bidder( this covers skid mounted instruments/instruments already erected by vendor and provided at site )
Erection / installation of pressure gauge on pipe line/ vessel/stand/ frame including small welding as per hookup diagram (preparation of gauge board if required). [as per attached hook-ups & installation drawing.]
The job includes the following: Shifting of new instrument with its accessories from store to work site ,Installation of pressure gauge / vacuum gauge / draught gauge with its accessories like snubber /gauge saver/ syphon etc.Fabrication and installation of manifold, syphon . Fabrication and installation of stanctions, canopy for instrument etc wherever necessary.
All above jobs are inclusive of supply of all sorts of erection materials (including clamps, nut bolt etc.) and consumables excepting the supply of Pipes, Pipe Fittings, Structural Material, and Instruments. providing Holes in Blind flange for veseel related tags, Hydraulic testing of manifold. impusle pipie, DP test,PMI test Painting of all erected structural items (excluding impulse line) inclusive supply of paint (Paint make shall be Asian/Berger/Nerolac). The installation shall be as per typical installation diagram.
Necessary skilled & unskilled manpower, supervision, tools & tackles, transporting vehicle, supply of all sorts of consumables shall be in BIDDER’s scope. The job shall be carried out as per specification and direction of Engineer-in-charge.
All types Pressure gauge erection / installation (includes impulse piping and necessary support fabrication & installation)
All types Pressure gauge calibration
The job includes the following: Receiving & shifting of Temperature instrument with Thermowell with its accessories from store/any other place inside OWNER campus & transport to work site.Fixing of thermowell with all accessories at any height. this includes impulse tubing, Glanding, ferruling,termination Installation of Analyzers at any height after taking proper clearance.
All above jobs are inclusive of supply of all erection materials, grouting material (cement, concrete, sand etc.) and consumables.
Necessary skilled & unskilled manpower, supervision, & tackles, transporting vehicle, consumables including Teflon tape etc. will be in BIDDER’s scope.
OWNER/PDIL/Others will be providing Analyzer system , The job shall be carried out as per specification and direction of Engineer-in-charge.
Dial type thermometers with thermowell erection / installation
Dial type thermometers with thermowell calibration
Temperature elements (Thermocouple / RTD) with thermowell erection / installation, Glanding ferruling & termination
Temperature elements (thermocouple / RTD) with thermowell functional check, loop checking
Temperature elements (thermocouple / RTD) with thermowell -calibration
Erection / installation / fixing of online PH & Conductivity/dew point/silica/ O2/CO Analyzers.
The job includes the following: Receiving & shifting of PH & Conductivity Analyzer its accessories from store/any other place inside OWNER campus & transport to work site.Fixing of PH & Conductivity and other Analyzers with all accessories on at any heigh after taking proper clearance.
All above jobs are inclusive of supply of all erection materials, grouting material (cement, concrete, sand etc.) and consumables.
Necessary skilled & unskilled manpower, supervision, & tackles, transporting vehicle, consumables including Teflon tape etc. will be in BIDDER’s scope.
OWNER/PDIL/Others will provide gasket sheet, however all gasket cutting for completing the job will be in BIDDER’s scope. The job shall be carried out as per specification and direction of Engineer-in-charge.
PH/Conductivity Analyzer Installation/erection ( includes Tubing, Glanding ,Ferruling &Termination)
Calibration of PH / Conductivity Analyzer System
PH/Conductivity Analyzer functional check, loop checking etc
Dew Point Analyzer Installation/erection ( includes Tubing, Glanding ,Ferruling &Termination)
Calibration of Dew Point Analyzer System
Dew Point Analyzer functional check, loop checking etc
O2 Analyzer Installation/erection ( includes Tubing, Glanding ,Ferruling &Termination)
O2 Analyzer System
O2 Analyzer functional check, loop checking etc
CO Analyzer Installation/erection ( includes Tubing, Glanding ,Ferruling &Termination)
CO Analyzer System
CO Analyzer functional check, loop checking etc
Erection of Control Valves /on-off/MOV valveshall be part of Mechanical Erection Tender and laying , galnding ,Termination of cables etc shall be bidders scope:bidder to note that necessary tubing from ADP to control valve shall be in bidders scope, there shall not be any seperate rate for tube works
Glanding, ferruling and termination of the cable wherever required, including supply of ferrule and lugs is in BIDDER’s scope of supply. Supplied lugs shall be Dowel make only (Applicable for any electrical device like limit switch, SOV,continuous position feedback etc. mounted on the control valve/MOV.)Fabrication, installation and grouting of support, if required. Grouting material (cement, concrete, sand etc.) shall be in BIDDER’s scope. Erection supervision of Electrohydraulic control valves/on-off valves/MOV is also in BIDDER's scope. (the job aalso includes but not limited to tubing frpm ADP to control valves including snecessary structural support)
Hot bolting of the flanges after charging of line, if required.Leakage testing, stroke checking and calibration of the control valve/MOV will be in BIDDER’s scope. Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive supply of paint and primer. (Paint and Primer make shall be Asian/Berger/Nerolac).
The installation shall be as per typical installation diagram as enclosed. Necessary skilled & unskilled manpower, supervision, tools & tackles, transporting vehicle, consumables including Teflon tape etc. required for the job will be in BIDDER’s scope.The job shall be carried out as per specification, direction of Engineer-in-charge.
Size of control valve: up to 2’’ Errection supervision Glanding ,ferruling termination of Signal cables ( includes continuous position f/band sov)
Size of control valve : up to 2’’ functional check, loop checking ( includes continuous position f/band sov)
Size of Control Valve : Up to 2’’ Calibration ( includes continuous position f/band sov)
Size of Control Valve : Above 2’’ and up to 4’’ Errection supervision Glanding ,ferruling termination of Signal cables ( includes continuous position f/band sov)
Size of Control Valve : Above 2’’ and up to 4’’ functional check, loop checking ( includes continuous position f/band sov)
Size of Control Valve : Above 2’’ and up to 4’’ Calibration ( includes continuous position f/band sov)
Size of Control Valve : Above 4’’ and up to 6’’Errection supervision Glanding ,ferruling termination of Signal cables ( includes continuous position f/band sov)
Size of Control Valve : Above 4’’ and up to 6’’ functional check, loop checking ( includes continuous position f/band sov)
Size of Control Valve : Above 4’’ and up to 6’’ Calibration ( includes continuous position f/band sov)
Size of Control Valve : Above 6’’ and up to 12’’Errection supervision Glanding ,ferruling termination of Signal cables ( includes continuous position f/band sov)
Size of Control Valve : Above 6’’ and up to 12’’ functional check, loop checking ( includes continuous position f/band sov)
Size of Control Valve : Above 6’’ and up to 12’’ Calibration ( includes continuous position f/band sov)
Size of MOV :above 8" and upto 10: Erection supervision Glanding ,ferruling termination of Signal cables ( includes continuous position f/band sov)
Size of MOV :above 8" and upto 10: functional check, loop checking ( includes continuous position f/band sov)
Size of MOV :above 8" and upto 10: Calibration ( includes continuous position f/band sov)
Size of MOV :above 10: Erection supervision Glanding ,ferruling termination of Signal cables ( includes continuous position f/band sov)
Size of MOV :above 10: functional check, loop checking ( includes continuous position f/band sov)
Size of MOV :above 10: Calibration ( includes continuous position f/band sov)
Erection supervision of flow element (orifice assembly with flanged connection).
Errection Is a Part of Mechanical Tender
Orifice assembly with Flanged Connection up to 3"
Orifice assembly with Flanged Connection above 3" to 12"
The job includes the following: Receiving & shifting of LG & its accessories from store/any other place inside OWNER/PDIL campus & transport to work site.Fixing of LG with all accessories on vessel/standpipe at any height. taking proper clearance.
Fabrication, installation and grouting of small supports for instrument if necessary, All above jobs are inclusive of supply of all sorts of erection materials (including clamps, nut bolt etc.) and consumables excepting the supply of Pipes, Pipe Fittings, Structural Material, and Instruments. providing Holes in Blind flange for veseel related tags, Hydraulic testing of manifold. impusle pipie, DP test,PMI test Painting of all erected structural items (excluding impulse line) inclusive supply of paint (Paint make shall be Asian/Berger/Nerolac). The installation shall be as per typical installation diagram.
Necessary skilled & unskilled manpower, supervision, & tackles, transporting vehicle, consumables including Teflon tape etc. will be in BIDDER’s scope.
calibration/Erection of level Gauges( ALL TYPES) on vessel/Stand pipe
Erection and Installation of Inline flowmeter (all types) on pipe as per attached hook-ups & installation drawing.
The job includes the following: Erection and installation, Glanding, ferruling and termination of the cable wherever required, including supply of ferrule and lugs is in BIDDER’s scope of supply Supplied lugs shall be Dowel make only Fabrication, installation and grouting of support, if required. Grouting material (cement, concrete, sand etc if required.) shall be in BIDDER’s scope.
Fabrication, installation and grouting of small supports for instrument if necessary, All above jobs are inclusive of supply of all sorts of erection materials (including clamps, nut bolt etc.) and consumables excepting the supply of Pipes, Pipe Fittings, Structural Material, and Instruments. providing Holes in Blind flange for veseel related tags, Hydraulic testing of manifold. impusle pipie, DP test,PMI test Painting of all erected structural items (excluding impulse line) inclusive supply of paint (Paint make shall be Asian/Berger/Nerolac). The installation shall be as per typical installation diagram.
Necessary skilled & unskilled manpower, supervision, & tackles, transporting vehicle, consumables including Teflon tape etc. will be in BIDDER’s scope.
Inline Flow Meter all types (FT)- Erection / installation (glanding, and termination, erection of Statction & Supports Canopy etc if any)
Inline Flow Meter all types (FT)- Functional check, loop checking
Inline Flow Meter all types (FT)- Calibration
Calibration,Erection supervision of TSV/Safety/Vaccum Relief Valves/Self Actuating Valve
Erection of TSV/Safety relief valves/Vaccum rlief valves/Self Actuating Valve shall be part of Mechanical Erection Tender
The job includes the following: Shifting of new instrument with its accessories from store to work site Calibration of Pressure safety/Pressure regulating Valve as per the instructions of Engineer incharge , bidder to note that necessary washing connection tubing & steam tracing tubing shall be included in this quote. there is no seperate price for tubing works
Necessary skilled & unskilled manpower, supervision, & tackles,PSV/PCV calibration bench, transporting vehicle, consumables including Teflon tape etc. will be in BIDDER’s scope.
PSV/TSV/VRV/PCV- Calibration
PSV/TSV/VRV/PCV- steam tracing , flushing connection tubing works
SECTION B-2 - INSTRUMENT WORKS (ERECTION OF CABLE DUCT , CABLE LAYING AND CABLE TRAY LAYING,CABLE DUCT LAYING, INSTALLATION OF JUNCTION BOX , LOCAL CONTROL PANEL , AIR DISTRIBUTION POT ETC. , AS PER INSTALLATION DRAWING)
Cable laying in Cable tray of Instrumentation cable inclusive of unpacking, Transportation from store, primary checking, testing, etc.
Horizontal and vertical laying of different instrument cables (Signal / Power / Control / Alarm / Thermocouple / RTD /OFC/CO-AXIALetc.) of different sizes and types (armoured/unarmoured) in Cable tray, including routing through MCT blocks, fixing of galvanized clamps and screws for fixing cables on to the supports in theTray/ structure etc., providing aluminium cable tags at both the ends of the cable, line testing and transportation from stores to site, unpacking, straightening, dressing of cable & returning the empty drums with unused cable, if any to stores complete with labour and materials as per the drawings, specifications and directions of the engineer-in-charge, Bidder to note that this work shall include price for Glanding at both sides ie; JB side and Panel side, there will not be any seperate Price ( Sand removal and filling for cable laying sall be in bidders scope , there wont be any seperate price for the same bidder to quote accodingly)
SOR (cable Laying)
Cable Size: Overall diameter upto 20 mm
Cable Size: Overall diameter > 20 mm upto 40 mm
CABLE GLANDING & TERMINATION WITH DOUBLE COMPRESSION SS316 GLANDS
Glanding & termination of signal/ control/triad/T/C and power cables with double compression type SS316 cable glands, restoration of insulation, clamping of the cable including supply of clamps. Tagging with aluminium tags, earthing of armour, connection to the equipment terminals etc. excluding supply of double compression brass / SS316 cable glands. All complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge.
Cable gland size 1/2" & 3/4"
Cable gland size 1" & 1.5"
Supply & laying of perforated FRP cable tray including joining, cutting, bending, supporting etc. Laying of MS/ GI / FRP Perforated cable trays / Cable duct (supply of tray, cable duct & structural steel in BIDDER’s scope) - refer layout.
The job includes the following: Shifting of tray /duct material from store to work site, fabrication and laying of perforated trays as per specifications & direction of Engineer in charge Supply of Perforated Trays & structural steel shall be in BIDDER’s scope.
All other material including grouting material (cement, concrete, sand etc.), clamps, bolts, nuts etc. required to complete the job shall be in BIDDER’s scope.Fabrication, installation and grouting of support wherever required, cutting and modification of existing support if required inclusive of supply of erection consumable materials.
Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive of supply of paint and primer. (Paint and Primer make shall be Asian/Berger/Nerolac).Necessary skill & unskill manpower, supervision, tools & tackles, transporting vehicle, consumables will be in BIDDER’s scope. The job shall be carried out as per specification and direction of Engineer-in-charge.( Sand removal and filling for cable laying sall be in bidders scope , there wont be any seperate price for the same bidder to quote accodingly)
CableTray (Perforated ) 2500 x 600 x 100 ( including bends/cross/tees and all other fittings and acceessories)
Cable Tray (Perforated) 2500 x 300 x 55 ( including bends/cross/tees and all other fittings and acceessories)
Cable Trays (Perforated) 2500 x 200 x 55 ( including bends/cross/tees and all other fittings and acceessories)
Cable Trays (Perforated) 2500 x 100 x 55 ( including bends/cross/tees and all other fittings and acceessories)
Cable Trays (Perforated) 2500 x 50 x 55 ( including bends/cross/tees and all other fittings and acceessories)
Installation of junction box with canopy / local control panel/emergency push button etc including structural welding, clamping etc. (supply of junction box & local control panel with push buttons in OWNER/PDIL's scope)
The job includes the following: Shifting of new Junction Box/LCP with pushbuttons (for reset,start stop at grade level ) with its accessories from store to work site. Fabrication and installation of supports and installation of junction box.Screwing, plugging of unused entries of Junction Box. Fabrication, installation with canopy and grouting of support. Grouting material (cement, concrete, sand etc.) shall be in BIDDER’s scope. Cutting and modification of existing support, if required.
Glanding of multicore & branch cables, aluminium tagging of the glands, supply of aluminium tag is in BIDDER’s scope of supply but cable gland shall be supplied free of cost by owner.
Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive supply of paint and primer. (Paint and Primer make shall be Asian/Berger/Nerolac).
Necessary skilled & unskilled manpower, supervision, tools & tackles, transporting vehicle, consumables will be in BIDDER’s scope.The job shall be carried out as per specification and direction of Engineer-in-charge.
Bidder to note that Suitable earthing using 10MMSQ eathing cable as per drawings or direction form engineer incahrge from panel to Earth Busbar shall be provided. there wont be any special rate for the same.
Explosion proof junction box suitable for 12 pair cable.
Installation of Pushbuttons
Structural work & fabrication for instrument items like tray support, mounting frames for instruments, base frames, canopy for jb & transmitters, any other required for supporting instrument items. (Structural & pipe material is in BIDDER's scope)
The job includes the following: Fabrication of yoke supports as per drawing for instruments of flow, pressure, level, temperature etc.as per installation drawing .Installation of the same on supports / wall / ground by welding / clamping / grouting as per requirement. Any other material if required shall be in BIDDER's scope.
Grouting material (cement, concrete, sand etc.) / welding material / clamping material shall be in BIDDER’s scope.Cutting and modification of existing support if required.
Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive supply of paint and primer. (Paint and Primer make shall be Asian/Berger/Nerolac).Necessary skilled & unskilled manpower, supervision, tools & tackles, transporting vehicle, consumables will be in BIDDER’s scope.The job shall be carried out as per specification and direction of Engineer-in-charge.bidder to note that there is no seperate rate is allowded for stanction supports.
50 x 50 x 6THK ANGLE MS
100 x 50 x 6THK CHANNEL MS
FOUNDATION BOLTS, NUTS & WASHER 10MM X 150L MS
COVER PLATE 4 MMTHK MS
RIBS (PLATE) 250 X 250 X 6 THK MS PLATE
BASE PLATE 250 X 250 X 6 THK MS PLATE
2” MS PIPE FOR STAND PIPE, MEDIUM, AS PER IS:1239
Erection/installation of Air Distribution Port as per AP layout ( will be provided later) any structural supports ,skilled manpower and consumables, tools & tackles for completeion of Job shall be in bidders scope
The job includes the following: Ferruling, Glanding, termination,Fabrication of supports,Installation of the same on supports / wall / ground by welding / clamping / grouting as per requirement. Any other material if required shall be in BIDDER's scope. Grouting material (cement, concrete, sand etc.) / welding material / clamping material shall be in BIDDER’s scope.Cutting and modification of existing support if required.Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive supply of paint and primer. (Paint and Primer make shall be Asian/Berger/Nerolac).Necessary skilled & unskilled manpower, supervision, tools & tackles, transporting vehicle, consumables will be in BIDDER’s scope.The job shall be carried out as per specification and direction of Engineer-in-charge. Bidder to note that Suitable earthing using 10MMSQ eathing cable as per drawings or direction form engineer incahrge from panel to Earth Busbar shall be provided. there wont be any special rate for the same.
AIR DISTRIBUTION PORT (AS PER ATTACHED DWNG)
Erection/installation of local control panel/ DCS/PLC panels
The job includes the following: Glanding , termination,Fabrication of supports,Installation of the same on supports / wall / ground by welding / clamping / grouting as per requirement. Any other material if required shall be in BIDDER's scope. Grouting material (cement, concrete, sand etc.) / welding material / clamping material shall be in BIDDER’s scope.Cutting and modification of existing support if required.Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive supply of paint and primer,. (Paint and Primer make shall be Asian/Berger/Nerolac).Necessary skilled & unskilled manpower, supervision, tools & tackles, transporting vehicle, consumables will be in BIDDER’s scope.The job shall be carried out as per specification and direction of Engineer-in-charge.( Sand removal and filling for cable laying sall be in bidders scope , there wont be any seperate price for the same bidder to quote accodingly) Bidder to note that Suitable earthing using 10MMSQ eathing cable as per drawings or direction form engineer incahrge from panel to Earth Busbar shall be provided. there wont be any special rate for the same.
CONTROL/MARSHALLING/LOCAL PANELS
Erection/installation & commissioning of Telephone network The job includes the following: Glanding , termination,Fabrication of supports,Installation of the same on supports / wall / ground by welding / clamping / grouting as per requirement. Any other material if required shall be in BIDDER's scope. Grouting material (cement, concrete, sand etc.) / welding material / clamping material shall be in BIDDER’s scope.Cutting and modification of existing support if required.Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive supply of paint and primer. (Paint and Primer make shall be Asian/Berger/Nerolac).Necessary skilled & unskilled manpower, supervision,Machines, tools & tackles, transporting vehicle, consumables will be in BIDDER’s scope.The job shall be carried out as per specification and direction of Engineer-in-charge.( Sand removal and filling for cable laying shall be in bidders scope , there wont be any seperate price for the same bidder to quote accodingly)
SOR for Erection/installtion-Erection/installation of CCTV system as Section--A INSTRUMENT WORKS (SUPPLY ) - CCTV for OSBL facilites and Survillance Purpose of TFL Fertilizer complex : Design , Engineering & Supply
Installation of Telepone system as Per detailed Specification ncluding JB/Terminal Box( no special rate for terminal box)
Cable laying (20 Pair & 5 Pair)
Deleted
Deleted
Erection/installation & commissioning CCTV System The job includes the following: This Job includes installation of GPS system in Urea bagging unit with asociated electronics, softweres and hooking up the same with the urea network. Glanding , termination,Fabrication of supports,Installation of the same on supports / wall / ground by welding / clamping / grouting as per requirement. Any other material if required shall be in BIDDER's scope. Grouting material (cement, concrete, sand etc.) / welding material / clamping material shall be in BIDDER’s scope.Cutting and modification of existing support if required.Painting of all erected structural items with one coat of ready mixed primer and two coats of approved quality synthetic enamel paint inclusive supply of paint and primer. (Paint and Primer make shall be Asian/Berger/Nerolac).Necessary skilled & unskilled manpower, supervision,Machines, tools & tackles, transporting vehicle, consumables will be in BIDDER’s scope.The job shall be carried out as per specification and direction of Engineer-in-charge,
Erection/installation commissioing of CCTV system as Section--A INSTRUMENT WORKS (SUPPLY ) - CCTV Complete system for whole fertiliser complex as per attached specification - Bidder shall engineering , supply, install, test and commissioning the ONVIF-IP based Closed circuit television (CCTV) Surveillance System,Complete CCTV System with all accessories like Cameras, power supply , JB , LIU, media convertor, OFC convertor, 22” LED workstation , server, VMS ,NAS for 365 days storage , one LED 72” ceiling mounted with 100 windows , software , license , surveillance software , analytical software , all cables, all mounting accessories , poles , civil works etc. (A at the TFL fertlizer complex . The purpose of the CCTV System is to monitor the facility operations & security surveillance from control room / Security room & Admin building to keep eye on facility covering Main gate entry /exit ,material gate exit / entry and other area of importance to the daily running of the complex by installing cameras to monitor resulting to enhancement in the Operational & Safety needs. It is intended to install CCTV system to track the Material movement, Recognition of persons and objects including vehicles through high quality images in and outside the plant by Security. The recording of the scene can be used in investigation, recreating the scene and establishing the truth.
Erection/installation commissioing Fixed Camera Section--A INSTRUMENT WORKS (SUPPLY ) - Fixed Perimeter 1080p HD IP outdoor Cameras IP66 housing with Day/night fixed camera with advanced video analytics, Min 75 Mtrs IR range , Camera with 1/3" or better CMOS , 1920 (H) X 1080 (V); 2 MP or better , Inbulit Min 128 GB or higher GB SD Card Storage for local recording etc. as per attached specification
Erection/installation commissioing PTZ Camera Section--A INSTRUMENT WORKS (SUPPLY ) - 1080p HD IP Indoor / outdoor PTZ Cameras with 1/3" or better progressive scan Exmor CMOS , 1920 (H) X 1080 (V); 2 MP or better, 30 X optical Zoom (4.3 mm -129 mm) , 4X Digital Zoom
Supply , Erection/installation & commissioning MISCELLANEOUS The job includes the following: Supply, erection/installation & commissioing , interface, all residual engineering to complete the Instrumentation works as per scope shall be in Bidder's scope
Supply, erection/installation & commissioing , interface, all residual engineering to complete the Instrumentation works as per scope shall be in Bidder's scope
Sterling and Wilson Private Limited
Konstelec Engineers Pvt. Ltd.
Bridge and Roof Co India Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid