Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAdmitted-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹36.4 L | L1 | Admitted-Finance |
| 2 | L2₹39.0 L+₹2.6 L (7.07%)Admitted-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹39.0 L+₹2.6 L (7.07%) | L2 | Admitted-Finance |
| 3 | L3₹47.7 L+₹11.3 L (31.0%)Admitted-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | ₹47.7 L+₹11.3 L (31.0%) | L3 | Admitted-Finance |
| 4 | L4₹49.4 L+₹12.9 L (35.5%)Admitted-Finance 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹49.4 L+₹12.9 L (35.5%) | L4 | Admitted-Finance |
| 5 | L5₹58.0 L+₹21.5 L (59.1%)Admitted-Finance | ₹58.0 L+₹21.5 L (59.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Top Mind Industries Pvt Limited L5 | national engineering L2 | VIMAL TRADERS AND SUPPLIERS L4 | M/S NANCY ENTERPRISES L1 | S S BUILDERS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only along with T&P for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare parts like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line any where about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in- Charge complete all as directed at site.
Note :- (i) Flap motor and display circuit required will be measured and paid under respective items.
(ii) Attending any number of complaints of same unit relating to FCU of different nature will be considered as one job.
(iii) Replacement of major items shall be measured and paid for separately under respective item of schedule 'A'.
(iv) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc. will be completed round the clock by suitable trademen, Welder with suitable T & P including portable heating materials-01 No, Skilled Mechanic of CHS - 01 No, Plumber/Fitter - 01 No and Supervisor - 01 No as per direction of Engr-in-Charge.
(v) Job slip will be maintained by the Contractor Supervisor under supervision of concerned JE E/M and suitable communication shall be maintained through JE incharge round the clock.
(vi) On not attending complaint within 48 Hours (2 days), a recovery of Rs 2000.00 will be effected. In addition, the expenditure incurred for rectification of complaint/ defect by any other means will also be recovered from the payment due to the Contractor. | 300 | Each Job | 100 ₹30,000 Lowest | 1,500 ₹4,50,000 | 500 ₹1,50,000 | 200 ₹60,000 | 250 ₹75,000 |
| 1.01 | Supply only flap motor compatible for FCU of capacity upto 6000 KCal/Hr. | 50 | Each | 100 ₹5,000 Lowest | 1,500 ₹75,000 | 450 ₹22,500 | 2,000 ₹1,00,000 | 3,000 ₹1,50,000 |
| 1.02 | Supply only display circuit compatible for FCU of capacity upto 6000 KCal/Hr. | 120 | Each | 150 ₹18,000 Lowest | 800 ₹96,000 | 750 ₹90,000 | 1,000 ₹1,20,000 | 1,500 ₹1,80,000 |
| 2.00 | Dismantling of burner assembly of CHS and removing side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 6.00 lakh KCal/Hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by means of welding and packing the burner sides with asbestos/rope to avoid leakage of burn gases or any other repair required at site and reassembling/ testing the same, complete all as specified and/ or as directed by Engr-in-Charge.
Note :- New sequence controller, ignition rod, ignition transformer, temp controller, photo cell electrode, burner nozzle, thermostat and bridge rectifier shall be measured and paid under repsective item as supply only and labour element included in the quoted rate of this item. | 5 | Each Job | 35,000 ₹1,75,000 | 15,000 ₹75,000 Lowest | 20,000 ₹1,00,000 | 20,000 ₹1,00,000 | 25,000 ₹1,25,000 |
| 3.00 | All as per Srl Item No. 2.00 above, but for 3.0-4.0 Lakh KCal/Hr. | 4 | Each Job | 35,000 ₹1,40,000 | 15,000 ₹60,000 Lowest | 20,000 ₹80,000 | 20,000 ₹80,000 | 20,000 ₹80,000 |
| 4.00 | All as per Srl Item No. 2.00 above, but for 0.5-2 Lakh KCal/Hr. | 8 | Each Job | 35,000 ₹2,80,000 | 15,000 ₹1,20,000 Lowest | 15,000 ₹1,20,000 Lowest | 20,000 ₹1,60,000 | 20,000 ₹1,60,000 |
| 5.00 | Supply only sequence controller as per existing model suitable for burner of capacity 6 lakh KCal/Hr including testing. | 2 | Each | 5,500 ₹11,000 | 6,000 ₹12,000 | 1,500 ₹3,000 Lowest | 10,000 ₹20,000 | 5,500 ₹11,000 |
| 6.00 | Supply only sequence controller as per existing model suitable for burner of capacity 3-4 lakh KCal/Hr including testing. | 2 | Each | 5,500 ₹11,000 | 4,000 ₹8,000 | 1,200 ₹2,400 Lowest | 10,000 ₹20,000 | 4,500 ₹9,000 |
| 7.00 | Supply only sequence controller as per existing model suitable for burner of capacity 0.5 to 2.0 lakh KCal/Hr including testing. | 4 | Each | 5,000 ₹20,000 | 3,800 ₹15,200 | 1,500 ₹6,000 Lowest | 10,000 ₹40,000 | 3,500 ₹14,000 |
| 8.00 | Supply only ignition rod as per existing model suitable for burner of capacity 6 lakh KCal/Hr. | 3 | Pair | 10 ₹30 Lowest | 200 ₹600 | 2,500 ₹7,500 | 1,000 ₹3,000 | 2,500 ₹7,500 |
Tender Value
₹82 L
EMD Value
₹1.5 L
Closing Date
5 Sept 2026, 6:00 pmClosed
CWE, HQ 138 WE
CWE, HQ 138 WE
MAINTENANCE/SERVICING AND ATTENDING DAY TO DAY COMPLAINTS OF CENTRAL HEATING PLANTS, HOT WATER BOILERS, STANDALONE ALONG WITH ACCESSORIES AT SECTOR C UNDER AGE E/M-I OF GE 865 EWS
2026_MES_782191_1
138WE/L-76/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.5 L
Yes
16 Sept 2026
1 Aug 2026
12 Sept 2026
1 Aug 2026
5 Sept 2026
22 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour only along with T&P for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare parts like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line any where about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in- Charge complete all as directed at site.
Note :- (i) Flap motor and display circuit required will be measured and paid under respective items.
(ii) Attending any number of complaints of same unit relating to FCU of different nature will be considered as one job.
(iii) Replacement of major items shall be measured and paid for separately under respective item of schedule 'A'.
(iv) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc. will be completed round the clock by suitable trademen, Welder with suitable T & P including portable heating materials-01 No, Skilled Mechanic of CHS - 01 No, Plumber/Fitter - 01 No and Supervisor - 01 No as per direction of Engr-in-Charge.
(v) Job slip will be maintained by the Contractor Supervisor under supervision of concerned JE E/M and suitable communication shall be maintained through JE incharge round the clock.
(vi) On not attending complaint within 48 Hours (2 days), a recovery of Rs 2000.00 will be effected. In addition, the expenditure incurred for rectification of complaint/ defect by any other means will also be recovered from the payment due to the Contractor. | 300 | Each Job | - | - |
| 1.01 | Supply only flap motor compatible for FCU of capacity upto 4500 KCal/Hr. | 50 | Each | - | - |
| 1.02 | Supply only display circuit compatible for FCU of capacity upto 4500 KCal/Hr. | 120 | Each | - | - |
| 2 | Dismantling of burner assembly of CHS and removing side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 6.00 lakh KCal/Hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by means of welding and packing the burner sides with asbestos/rope to avoid leakage of burn gases or any other repair required at site and reassembling/ testing the same, complete all as specified and/ or as directed by Engr-in-Charge.
Note :- New sequence controller, ignition rod, ignition transformer, temp controller, photo cell electrode, burner nozzle, thermostat and bridge rectifier shall be measured and paid under repsective item as supply only and labour element included in the quoted rate of this item. | 5 | Each Job | - | - |
| 3 | All as per Srl Item No. 2.00 above, but for 3.0 Lakh KCal/Hr. | 4 | Each Job | - | - |
| 4 | All as per Srl Item No. 2.00 above, but for 0.5-2 Lakh KCal/Hr. | 8 | Each Job | - | - |
| 5 | Supply only sequence controller suitable for burner of capacity 6 lakh KCal/Hr including testing. | 2 | Each | - | - |
| 6 | Supply only sequence controller suitable for burner of capacity 3 lakh KCal/Hr including testing. | 2 | Each | - | - |
| 7 | Supply only sequence controller suitable for burner of capacity 0.5 to 2.0 lakh KCal/Hr including testing. | 4 | Each | - | - |
| 8 | Supply only ignition rod suitable for burner of capacity 6 lakh KCal/Hr. | 3 | Pair | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TENDERL762627.pdf
Tender Documents • 1.10 MB
BOQ_876287.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .