Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.0 Cr+₹2.9 L (3.02%)Rejected-Finance CHATRA RAMTARAK HAT CHATRA RAMTARAK HAT | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.0 Cr+₹3.9 L (4.00%)Rejected-Finance LAKE ROAD LAKE TOWN WEST SILIGURI 734007 | SILIGURI | DARJEELING | WEST BENGAL | 734007 | L3 | Rejected-Finance L3 | |
| 4 | L4₹1.0 Cr+₹5.6 L (5.73%)Rejected-Finance 389 A DHOOP COMPANY ROAD PRADHAN NAGAR SILIGURI 734 003 | SILIGURI | DARJEELING | WEST BENGAL | 734003 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
27 Sept 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NIRANJAN KUMAR DAS/SE/NBDD
Annex Building, Uttarkanya, Fulbari, Jalpaiguri
AMC of whole Electrical Infrasturecutre of the Cooch Behar Government Engineering College Campus
2024_NBDD_746634_1
NBDD/BS/SE /NIQ-04 - (EL) of 2024-2025
Open Tender
Electrical Work/ Equipment
Item Rate
365 days
Coochbehar
Please refer Tender documents.
6 documents required · 6 mandatory
₹1 L
Yes
7 Jan 2025
6 Sept 2024
30 Sept 2024
6 Sept 2024
27 Sept 2024
6 Sept 2024
Amount
Maintenance of Electrical Installations at Coochbehar Govt. Engineering College premises for 4 nos Boys Hostel and Girls Hostel following persons for duty required in Monthly basis. 01 (one) No Skilled- alongwith 01 (one) no. Semi-skilled worker Round the clock operation (24 hours in a day)
Supply of following type materials for manetenance pourpose like- Wire,conduict, casing- capping, modular switches,Socket,Plug top,Starter and modular type box.MCB Enclosure 2-way
MCB Enclosure 4-way
20 mm dia PVC Conduit
25 mm dia PVC Conduit.
PVC casing-capping of size 20x12mm
PVC casing-capping of size 25x12mm
32mm heavy gauge Polythene Pipe
1.5 sq.mm 'FR' stranded Copper Wire
2.5 sqmm'FR' stranded Copper Wire
4.0 sqmm 'FR' stranded Copper wire
6.0 sqmm 'FR' stranded Copper wire
10 sqmm 'FR' stranded Copper wire
2 module GI box
4 module GI box
6 module GI box
2 row 12 module GI box
2 row 18 module GI box
2 module Cover plate
3 module Cover plate
4 module Cover plate
6 module Cover plate
2 row 12 module Cover plate
2 row 18 module Cover plate
6A Modular type Switch
16A Modular type Switch
6A Modular type 5 pin Plug Socket
16A Modular type 6 pin Plug Socket
Modular socket type 2 module regulator
20/25A starter
20/25A plug top
50mm GI pipe (ISI-Medium)
Red led / Zinc Oxied primar
Synthetic Enamel Paint Gr.II
RO primar
Alum. Paint
MS Clamp (380x25x3mm)
MS Clamp (380x40x6mm)
200A - 400 A HRC Fuse
100A-160A HRC Fuse
32A-63 A HRC Fuse
Fixing only TPN switch fuse units in Sheet Steel enclosure with HRC fuses on angle iron frame on wall for 32A to 400A
Supplying of 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / djustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make-Legrand) 250 A MCCB-35 ka
Supplying of 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make-Legrand) 6-32A SP MCB
6-32A DP MCB
40A DP MCB
63A TP MCB
63A FP MCB
Supply of 1.1 KV grade PVC/ Aluminium armouredcable of following sizes: 3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
4 core 16 sqmm
2 core 6 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
4 core 16 sqmm
2 core 6 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
4 core 16 sqmm
2 core 6 sqmm
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC) 2 core 4-10 sqmm cable
3½ / 4 core 10-16 sqmm cable
3½ / 4 core 50 sqmm cable
3½ / 4 core 25-35 sqmm cable
3½ / 4 core 120-150 sqmm cable
3½ / 4 core 240 sqmm cable
Repairing of existing ceiling fans,wall fans,exhaust fans ,including overhauling and winding of coils
Repairing of existing fire pumps and water supply pumps,including overhauling and winding of coils.
Repairing or replacement of existing internal and external light fittings including lamp ,batten, driver and all other accessories.
Electronics LED driver of branded make for the following indoor/outdoor LED downlights/Street light luminaires. 36 Watt LED Flat panel
18 Watt LED downlights
6 Watt LED downlights
150 Watt LED Flood Light
172 Watt LED Flood Light
supply of condenser/Capacitor for 900/1200/1400 mm ceiling fan.
Electrical Maintenance Charges for Two nos 750KVA indoor Dry type transformer and 1no 11KV VCB and 1600Amps 2 nos LT Pannel as per attached Terms & condition and as per direction of E-I-C. Providing 1 (one) no Highly Skilled in Day Shift (i.e. 10 am to 6.00 pm) with 01 (one) no. Skilled licensed Electrician Round the clock operation (24 hours in a day) at Sub-Station building for maintain the above electrical equipments.[Shift may be changed as per derection of E-I-C or as per requirement for emergency basis].
Maintenance of Electrical Installations at Coochbehar Govt. Engineering College premises for Substation Building ,2nos. Workshop, Central facility and Library Building,Principal Quarters, Gymnecium including for Operation of the Diesel Generator set-200KVA and 160 KVA and 4 nos 6 HP Pump as Generator, Compound light and Pump operator around the whole campus following persons for duty as required in one Shift ( i.e. 02.00 PM to 10.00 PM) Per Month.a)Skilled-01No alongwith 1 (one) no. Semi-skilled worker Morning Shift( i.e. 06 AM to 02.00 PM) including 1 (one) no. Semi-skilled worker Night Shift( i.e. 10.00 PM to 06.00 AM) [Shift may be changed as per derection of E-I-C or as per requirement for emergency basis].
Weekly Checkup Cleaning, Tightening nuts, bolts with washers, Sockets, Glands, terminals of All types of SPN, TPN, VTPN DBs, Distribution Pannels and sub pannels of all buildings including Main LT Pannels installed in Sub-station and Clening and Checking of 2 nos 750 KVA Transformers, 11 KV 3 pannel VCB Pannel with expert Electrical Engineer on hire basis as a highly Skilled employee and 2nos Skilled and 2 nos Unskilled to be provided.(1 shift=8 hours)
Annual Maintenance Contract Service Charge (Eletro-Mechanical) for Kirloskar Make 160KVA Silent Generator Set ESN No: F6.8618/1620041 Engine Model No: 6SL150TA G2
Annual Maintenance Contract Service Charge (Eletro-Mechanical) for Kirloskar Make 200KVA Silent Generator Set ESN No: 6H.8404/1620200 Engine Model No: 6K1080TA G2
Inspection Fees of Manufracturer Authorised Sevice for 160 KVA and 200 KVA DG SET
Supply and fixing of Fule Filter Kit (Pack of 3) for 160 KVA and 200 KVA DG SET
Supply and fixing of LUB OIL (10Ltr Jar) of 160 KVA and 200 KVA DG SET
Supply and fixing of LUB OIL Filter Kit for 160 KVA and 200 KVA DG SET
Supply and fixing of AIR Filter Kit (Primary & Secondary) for 160 KVA and 200 KVA DG SET
Supply and fixing of Koolant of 160 KVA and 200 KVA DG SET
Supply of following type materials for manetenance pourpose like- Wire,conduict, casing- capping, modular switches,Socket,Plug top,Starter and modular type box. MCB Enclosure 2-way
MCB Enclosure 4-way
Multitune Call Bell (Anchor)
20 mm dia PVC Conduit
25 mm dia PVC Conduit.
PVC casing-capping of size 20x12mm
PVC casing-capping of size 25x12mm
32mm heavy gauge Polythene Pipe
1.5 sq.mm 'FR' stranded Copper Wire
2.5 sqmm'FR' stranded Copper Wire
4.0 sqmm 'FR' stranded Copper wire
6.0 sqmm 'FR' stranded Copper wire
10 sqmm 'FR' stranded Copper wire
2 module GI box
4 module GI box
6 module GI box
2 row 12 module GI box
2 row 18 module GI box
2 module Cover plate
3 module Cover plate
4 module Cover plate
6 module Cover plate
2 row 12 module Cover plate
2 row 18 module Cover plate
6A Modular type Switch
16A Modular type Switch
6A Modular type 5 pin Plug Socket
16A Modular type 6 pin Plug Socket
Modular socket type 2 module regulator
20/25A starter
20/25A plug top
50mm GI pipe (ISI-Medium)
Red led / Zinc Oxied primar
Synthetic Enamel Paint Gr.II
RO primar
Alum. Paint
MS Clamp (380x25x3mm)
MS Clamp (380x40x6mm)
200A - 400 A HRC Fuse
100A-160A HRC Fuse
32A-63 A HRC Fuse
Fixing only TPN switch fuse units in Sheet Steel enclosure with HRC fuses on angle iron frame on wall for 32A to 400A
Supplying of 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / djustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make-Legrand) 250 A MCCB-35 ka
Supplying of 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make-Legrand) 6-32A SP MCB
6-32A DP MCB
40A DP MCB
63A TP MCB
63A FP MCB
100A FP MCB
125A FP MCB
Supply of 1.1 KV grade PVC/ Aluminium armouredcable of following sizes: 3.5 Core 240 sqmm
3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 95 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
3.5 Core 25 sqmm
4 core 16 sqmm
4 core 10 sqmm
2 core 10 sqmm
2 core 6 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. 3.5 Core 240 sqmm
3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 95 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
3.5 Core 25 sqmm
4 core 16 sqmm
4 core 10 sqmm
2 core 10 sqmm
2 core 6 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 3.5 Core 240 sqmm
3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 95 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
3.5 Core 25 sqmm
4 core 16 sqmm
4 core 10 sqmm
2 core 10 sqmm
2 core 6 sqmm
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC) 2 core 4-10 sqmm cable
3½ / 4 core 10-16 sqmm cable
3½ / 4 core 25-35 sqmm cable
3½ / 4 core 50 sqmm cable
3½ / 4 core 95 sqmm cable
3½ / 4 core 120-150 sqmm cable
3½ / 4 core 240 sqmm cable
Repairing of existing ceiling fans,wall fans,exhaust fans ,including overhauling and winding of coils
Repairing of existing fire pumps and water supply pumps,including overhauling and winding of coils.
Repairing or replacement of existing internal and external light fittings including lamp ,batten, driver and all other accessories.
Electronics LED driver of branded make for the following indoor/outdoor LED downlights/Street light luminaires. 36 Watt LED Flat panel
18 Watt LED downlights
6 Watt LED downlights
150 Watt LED Flood Light
172 Watt LED Flood Light
supply of condenser/Capacitor for 900/1200/1400 mm ceiling fan.
Maintenance of Electrical Installations at Coochbehar Govt. Engineering College premises for Academic and Administrative Building following persons for duty required in Monthly basis. 01 (one) No Highly Skilled and 01 (one) No Skilled- alongwith 01 (one) no. Semi-skilled worker.
Annual Comprehensive Maintenance Charges for attending 2.0 TR Wall Mounted Split type Air-Conditioning Machines with cordless remote at Administrative and Academic Building of Coochbehar government Engineering College with Co's own tools and tackles and devices as per terms and conditions enclosed.
Preventive and corrective comprehensive annual Maintenance of- A. Entire Fire Detection system including Fire detection pannel, i) Fire detectors -208 nos,ii) MCP- 22 nos, iii) Hooters- 23 nos etc.with Non comprehensive annual Maintenance of- B) Entire fire detection system including i) 55HP Main pump with motor 3ph.415V,50Hz. ii) 7.5HP Jockey pump with motor 3ph,415V,50Hz. iii)Diesel Pump. iv)Total Hydrant line of 80mm to 150mm dia from Underground Reservour to Academic Building and Administrative Building with hydrant post incluiding all valves and other all accessories related to fire fighting system at Coochbehar Govt. Engineering College premises considering two visit per month and as when required during troble/ fault condition.
Supply of following type materials for manetenance pourpose like- Wire,conduict, casing- capping, modular switches,Socket,Plug top,Starter and modular type box.MCB Enclosure 2-way
MCB Enclosure 4-way
20 mm dia PVC Conduit
25 mm dia PVC Conduit.
PVC casing-capping of size 20x12mm
PVC casing-capping of size 25x12mm
32mm heavy gauge Polythene Pipe
1.5 sq.mm 'FR' stranded Copper Wire
2.5 sqmm'FR' stranded Copper Wire
4.0 sqmm 'FR' stranded Copper wire
6.0 sqmm 'FR' stranded Copper wire
10 sqmm 'FR' stranded Copper wire
2 module GI box
4 module GI box
6 module GI box
2 row 12 module GI box
2 row 18 module GI box
2 module Cover plate
3 module Cover plate
4 module Cover plate
6 module Cover plate
2 row 12 module Cover plate
2 row 18 module Cover plate
6A Modular type Switch
16A Modular type Switch
6A Modular type 5 pin Plug Socket
16A Modular type 6 pin Plug Socket
Modular socket type 2 module regulator
20/25A starter
20/25A plug top
50mm GI pipe (ISI-Medium)
Red led / Zinc Oxied primar
Synthetic Enamel Paint Gr.II
RO primar
Alum. Paint
MS Clamp (380x25x3mm)
MS Clamp (380x40x6mm)
200A - 400 A HRC Fuse
100A-160A HRC Fuse
32A-63 A HRC Fuse
Fixing only TPN switch fuse units in Sheet Steel enclosure with HRC fuses on angle iron frame on wall for 32A to 400A
Supplying of 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / djustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make-Legrand) 250 A MCCB-35 ka
Supplying of 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make-Legrand) 6-32A SP MCB
6-32A DP MCB
40A DP MCB
63A TP MCB
63A FP MCB
100A FP MCB
125A FP MCB
Supply of 1.1 KV grade PVC/ Aluminium armouredcable of following sizes: 1 Core 400 sqmm
3.5 Core 300 sqmm
3.5 Core 240 sqmm
3.5 Core 95 sqmm
3.5 Core 25 sqmm
4 core 10 sqmm
2 core 10 sqmm
3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
4 core 16 sqmm
2 core 6 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. 1 Core 400 sqmm
3.5 Core 300 sqmm
3.5 Core 240 sqmm
3.5 Core 95 sqmm
3.5 Core 25 sqmm
4 core 10 sqmm
2 core 10 sqmm
3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
4 core 16 sqmm
2 core 6 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 1 Core 400 sqmm
3.5 Core 300 sqmm
3.5 Core 240 sqmm
3.5 Core 95 sqmm
3.5 Core 25 sqmm
4 core 10 sqmm
2 core 10 sqmm
3.5 Core 150 sqmm
3.5 Core 120 sqmm
3.5 Core 50 sqmm
3.5 Core 35 sqmm
4 core 16 sqmm
2 core 6 sqmm
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC) 2 core 4-10 sqmm cable
3½ / 4 core 10-16 sqmm cable
3½ / 4 core 50 sqmm cable
3½ / 4 core 25-35 sqmm cable
3½ / 4 core 120-150 sqmm cable
3½ / 4 core 240 sqmm cable
Repairing of existing ceiling fans,wall fans,exhaust fans ,including overhauling and winding of coils
Repairing of existing fire pumps and water supply pumps,including overhauling and winding of coils.
Repairing or replacement of existing internal and external light fittings including lamp ,batten, driver and all other accessories.
Electronics LED driver of branded make for the following indoor/outdoor LED downlights/Street light luminaires. 36 Watt LED Flat panel
18 Watt LED downlights
6 Watt LED downlights
150 Watt LED Flood Light
172 Watt LED Flood Light
supply of condenser/Capacitor for 900/1200/1400 mm ceiling fan.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80mm dia MS Pipe
100mm dia MS Pipe
150mm dia MS Pipe
Basic cost of 4 mm thick Anti Corrosive Pipe Protection Bituminous Tape,
Basic cost of anticorrosive Black paint
Single head gunmetal hydrant valve
Gunmetal short branch pipe
150mm dia butterfly valve
100mm dia butterfly valve
80mm dia butterfly valve
NON RETURN VALVE cast Iron double flange as per IS/5312 PN 1.6 rating complete with Bronze body & wedge Stainless Steel spindle, Gland packing, Rubber gasket 150mm dia Non Return Valve
100 mm dia Non Return Valve
80mm dia Non Return Valve
Cost of 150 mm dia Flanges
Cost of 100 mm dia Flanges
Cost of 80 mm dia Flanges
Cost of 8 Nos. Nut Bolt fastner & packing gaskets
Cost of welding rod
Repairing of 3 nos OTIS Make 8 Passenger lift for make in working Condition including the following materials - a) 3 nos Emergency light, b) 2 nos Encoder, c) 1 no.LVPB PCB Power supply 230V AC, d) 1 no. Ultra Drive UD402[ACD5], e) 3 nos ARD Battery.
Annual Maintenance Contract Service Charge for OTIS Make 2 Nos 8 Passenger Lift installed at Academic Building and 1 No. Passenger Lift installed at Administrative Bulilding in the Premises of Coochbehar Government Engineering college.
A.M.CONSTRUCTION (BID ID -5641680)
M/S. KRISHNA COMMERCIAL CORPORATION (BID ID -5640101)
SUPER BUILDERS (BID ID -5645113)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .