| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹8.6 L+₹1.7 L (25.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹8.7 L+₹1.8 L (26.7%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹11.1 L+₹4.2 L (61.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹12.5 L+₹5.6 L (81.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Sept 2023, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
DAY TO DAY MAINTENANCE OF EM ITEMS INCLUDING CONNECTED WORK IN RESIDENTIAL AND HOSPITAL AREAS AT 7 AFH KANPUR CANTT
2023_MES_616871_1
GE(AF) BR/CHK/T-19 OF 2023-24 8873/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
7 AFH Kanpur Cantt
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri
₹30,000
Yes
10 Nov 2023
4 Sept 2023
7 Oct 2023
4 Sept 2023
30 Sept 2023
18 Sept 2023
Amount
Fixing only in repair fluorescent tube light fitting complete energy efficient T-8 LED batten and integerated type single tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten rtc and all accessories pre wired and connecting up with and including three core flexible cord of minimum size 0.5 sqmm and PVC connector etc including provisions of hanging and well mounting complete all as directed by Engineer-in-Charge.
S & F in repair switch piano type 240 V, 5 Amp , SP one way flush type complete all as specified and directed by Engineer-in-charge.
S & F in repair bell push 240 V, 5 Amp , SP one way flush type complete all as specified and directed by Engineer-in-charge.
S&F in repair socket out let combination multipurpose 3 Pin 5 amp, 240 volt and with 2 pin 5 amp out let also flush type (non shuttered) complete all as specified and directed by Engineer-in-charge.
S&F in repair of switch socket outlet combination 3 pin 15 Amp, 3 Pin 5 Amp out let also flush type (non shuttered) complete all as specified and directed by Engineer-in-charge.
S&F in repair socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed.
S&F in repair ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed .
S&F repair lamp holder metal cased body of brass with back plate complete all as specified and directed by Engineer-in-charge.
S&F in repair sheet metal enclosure for MCB DB TPN double door, 4 way complete with 200 Amps rated Bus bar complete all as specified and directed .
S&F in repair sheet metal enclosures for MCCB distribution board TPN, 4 way double door type with and including MCCB 4 Pole, 100 Amps, 16 KA fixed type as incomer with 200 amp rated bus bar complete all as specified and directed by Engineer-in-charge.
S&F in repair sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed by Engineer-in-charge.
S&F in repair sheet metal enclosures for MCB distribution board SPN 4 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed by Engineer-in-charge.
S&F in repair Isolator TPN , 63 Amp 4 pole Isolator, 415 Volt in existing DBs complete all as specified and directed by Engineer-in-charge.
S&F in repair Isolator SPN , 63 Amp , 240 Volt complete all as specified and as directed by Engineer-in-charge.
S&F in repair MCB SP upto 32 Amp ,240 Volt ' C' series complete all as specified and as directed.
S&F in repair MCCB 4 Pole 16KA 100 Amps fixed type complete all as specified and as directed.
S&F in repair Isolator SPN , 20 to 40 Amp , 240 Volt complete all as specified and as directed.
S&F in repair bell electric , 240 Volt , single pole complete all as specified and as directed.
S&F in repair fan regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete all as specified and as directed.
M&L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC rigid conduit 20 mm dia with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and as directed. Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run complete all as specified .
All as per item No. 20.00 here in before but 6 Sqmm, 2 single core with PVC FRLS insulated, unsheathed stranded copper conductor cable and one run of size 6 Sqmm as earth lead complete.
M&L for sub main wiring with three runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC casing N Capping with all necessary fittings and accessories and 02xrun of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 6 Sqmm as continuous nuetral and earth wire (green in colour ) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly complete all as specified and as directed. (Note. Four run of cable and one run of PVC casing and capping and one run of earth continuity wire shall be measured as one run complete all as specified.)
S & F in repair bulk head fitting of any tyupe with LED bulk fitting with 9 watt LED complete connectionm with copper wire 23/.0076 two core from ceiling rose to bulk head fitting complete all as specified and direcrted by the Engineer -in-charge.
S & F in repair Mirror light fitting with LED type surface mounted decorative bed light fitting 10 Watt LED complete with all accessories such as LED driver, LED bulb/rod and LED batten with cover etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as directed.
S&F in repair fluorescent tube light fitting complete energy efficient T-8 LED batten and integrated type signle tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as directed. Make Cormpton Greaves Cat Part No DMLN1LT8-16 and LTT8-20 or equivalent of C&S/Philips/Wipro/Havells.
S&F in repair recessed mounted lumanaire with energy efficient 36 watt LED type including making connection to ceiling rose with copper flexible wire of size 23/0076 all as specified and directed by Engineer-in-Charge..
S&F in repair modular switch 1 way 6 Amp, 1 module, 240 V flush type complete all as specified and directed by Engineeer -in-charge.
S&F in repair modular switch 1 way 16 Amp, 1 module, 240 V flush type complete all as specified and directedby Engineer-in-charge
S & F in repair modular bell push, flush type, 6 Amp, 1 module, 240 V complete all as specified and directed by Engineer-in-charge.
S&F in repair modular socket, 6A-2/3 pin combined, 2 module, 240 V complete all as specified and directed by Engineer-in-charge.
S&F in repair modular socket, 6Amp / 16Amp-2/3 pin combined, 2 module, 240 V complete all as specified and directed by Engineer-in-charge.
S&F in repair modular fan step regulator, 120 W, 2 module, 240 V complete all as specified and directed by Engineer-in_charge.
S&F in repair modular white cover plate with frame, 3 module, complete all as specified and directed by Engineer-in-charge.
S&F in repair modular white cover plate with frame, 4 module, complete all as specified and directed by Engineer-in-charge.
S&F in repair modular white cover plate with frame, 6 module, complete all as specified and directed by Engineer-in-charge.
S & F in repair modular white cover plate with frame, 8 module, complete all as specified and directedby Engineer-in-charge.
S & F in repair modular white cover plate with frame, 12 module, complete all as specified and directed by Engineer-in-charge.
S & F in repair modular metal flush box, 3 module, complete all as specified and directed by Engineer-in-charge.
S & F in repair modular metal flush box, 4 module, complete all as specified and directed by Engineer-in-charge.
S & F in repair modular metal flush box, 6 module, complete all as specified and directed by Engineer-in-charge.
S & F in repair modular metal flush box, 8 module, complete all as specified and directed by Engineer-in-charge.
S & F in repair modular metal flush box, 12 module, complete all as specified and directed .
S&F in repair Isolator TPN , 100 Amp, 4 pole, 415 Volt complete all as specified and directed
S & F in repairLED integrated pattern T8, indoor decorative aluminium extruted LED fitting 36 wtt, 4 feet complete including connection from ceiling rose to T8 LED light fitting with three core PVC flexible wire 23/0076 copper conductor all as specified and directed
S & F in repair flexible wire 23/0076 copper conductor from ceiling rose to fitting/fixture complete all as specified and directed .
S & F in repair Metal clad single pole and a neutral enclosure with a two pin and earth plug and socket with one single pole MCB SP 20 Amp,240V complete all as specified and directed .
S & F in repair Metal clad triple pole and a neutral enclosure with a two pin and earth plug and socket with one single pole MCB TP 32 Amp,240V complete all as specified and directed .
S & F in repair round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
S & F in repair LED smart bright street light fitting 45 watt of IP 66 peotection with 70% energy efficient finless design complete including testing complete fixing on wall etc along with connection with copper wire 1.5 sqmm three core along with suitable bracket nut bolts wahsers complete all as specified and directed by Engineer-in-Charge.
S & F in repair heating element 1500 watts push type with gasket ISI marked all as specified and directed. Make- Theetha/Bajaj/Racold
All as per item No. 50.00 here-in-above but for 2000 watts
S & F in repair thermostatic switch suitable for Geysers of any make/ type with temperature range adjustable type 25 to 80 degree centigrade superior quality 20 Amps 220 Volts AC Supply complete all as directed. Make-Theetha/Bajaj/Racold
S&F in repair non return valve, cast copper alloy ISI marked horizontal/vertical position suitable for any make any type Geysers complete all as specified and directed.
S & F in repair indicator lamp 220 Volt AC supply rectangular/circular type as per sample superior quality with neon type lamp of red indicator complete all as specified.
S & F in repairs PVC insulated and sheathed copper conductor flexible cable of size 2.5 Sqmm for electrical connection complete all as specified and directed.
S & F in repair pressure release valve with inlet coupling ISI marked complete all as specified and directed .
S & F in repair PVC connection of 450 mm long & 15 mm dia with brass nut at both end suitable for Geysers complete all as specified and directed
S & F in repair chromium plated copper pipe connection 450 mm long & 15 mm dia suitable for Geysers complete all as specified and directed
S & F in repair capacitor 4 MFD complete all as specified and directed.
S & F in repair Plug top 3 pin 15 Amp 240 Volts complete all as directed.
S & F in repair capacitor 2.5 mfd complete all as directed by Engineer-in-Charge
Notes:- 1. The unit rate quoted for above items are also includes to provide the following workers to execute the above work as well as to attend the complaint assigned by concerned JE :- Two Electrician alongwith helper daily (except holiday & sunday) (ii) Contracotr will also deploy more man power if required to execute the above work. 2. Contractor shall ensure that materials required for attending complaint for a period of one week shall always be availabe at site. The labour as indicated in Note No 1 above shall be supervise by a supervisor of the contractor who will manage all the working labour till the time from 8.30 AM to 5.30 PM. 3. The labour as indicated in Note No 1 above shall report to the complaint cell at 8.30 AM and shall be left at 5.30 PM after handing over the receipt obtained from the unsers regarding attending the complaints. 4. The complaint shall be attended in the same day failing which a recovery of Rs. 500/- per day per complaint shall be made from the contractor's dues.
M/s A S Electrical
santosh electronics
Preetpowercontrol
M/S Asian Engineers
S B ENTERPRISES
commercial construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .