| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | ₹13.7 L Quoted ₹11.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹12.2 LRejected-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | ₹12.2 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | - | Rejected-Technical All documents found OK |
| Sl No | Description | Qty | Unit | M/s Kiran Electrical works L2 | Vedant Enterprises L1 |
|---|---|---|---|---|---|
| 1.01 | Supply and Providing of top Spout bushing insulator 11 kv grade with complete studs bushing and nuts and washer suitable to breaker design standrad | 18 | no | 7,000 ₹1.3 L | 6,750 ₹1.2 L |
| 1.02 | Supply and Providing of spring charging motor 230 volt operated 14000 rpm | 4 | no | 15,000 ₹60,000 | 13,500 ₹54,000 |
| 1.03 | Supply and Providing of complete gear teeth for charging of spring 3 mechanism. | 4 | no | 22,500 ₹90,000 | 22,500 ₹90,000 |
| 1.04 | Replacement of moving contact 800 amps grade | 16 | no | 5,000 ₹80,000 | 4,750 ₹76,000 |
| 1.05 | Replacement of tripping coil and closing coil 110 volt dc. operated. | 20 | no | 3,500 ₹70,000 | 3,500 ₹70,000 |
| 1.06 | Replacement of copper bus bar of 2 inch thickness of rated capacity of 400 6amps and peak withstand of 800 amps for bus connection. | 15 | kg | 1,000 ₹15,000 | 1,000 ₹15,000 |
| 1.07 | Complete cleaning and indoor painting with double coat enamel paint | 10 | no | 5,000 ₹50,000 | 4,500 ₹45,000 |
| 1.08 | Replacement of master trip relay 110volt operating. | 9 | no | 7,000 ₹63,000 | 6,500 ₹58,500 |
| 1.09 | Supoly and Providing of compiete wiring harness for 11 ky circuit breakerl for both operating and tripping for mechanical and electrical operation. | 3 | no | 17,500 ₹52,500 | 16,500 ₹49,500 |
| 1.10 | ISupply and Providing of complete wiring harness for 3.3 ky circuit breaker for both operating and tripping for mechanical and electrical operation. | 3 | no | 15,000 ₹45,000 | 15,000 ₹45,000 |
Tender Value
Refer Docs
EMD Value
₹17,200
Closing Date
25 Aug 2025, 9:00 amClosed
PE ENM
PE EM, AKKOCP
Onsite Repairing of 12 Nos of 11 kv and 3.3 kV grade 400 amps grade HT Circuit Breaker for control of different installed at 33 kv main sub station AKKOCP , BnK Area.
2025_CCL_341646_4
PE(EnM)/AKK OCP/e-tender/25-26/24
Open Tender
Electrical and Maintenance Works
7 days
AKKOCP
Please refer Tender documents.
3 documents required · 3 mandatory
₹17,200
11 Mar 2026
16 Aug 2025
26 Aug 2025
16 Aug 2025
25 Aug 2025
16 Aug 2025
16 Aug 2025 - 25 Aug 2025
Amount
Supply and Providing of top Spout bushing insulator 11 kv grade with complete studs bushing and nuts and washer suitable to breaker design standrad
Supply and Providing of spring charging motor 230 volt operated 14000 rpm
Supply and Providing of complete gear teeth for charging of spring 3 mechanism.
Replacement of moving contact 800 amps grade
Replacement of tripping coil and closing coil 110 volt dc. operated.
Replacement of copper bus bar of 2 inch thickness of rated capacity of 400 6amps and peak withstand of 800 amps for bus connection.
Complete cleaning and indoor painting with double coat enamel paint
Replacement of master trip relay 110volt operating.
Supoly and Providing of compiete wiring harness for 11 ky circuit breakerl for both operating and tripping for mechanical and electrical operation.
ISupply and Providing of complete wiring harness for 3.3 ky circuit breaker for both operating and tripping for mechanical and electrical operation.
Replacement & fixing of Vaccum interrepture 11 kv 400 amps grade with short circuit capacity of 3200 amps
Replacement & fxing of fixed sliding contact 11 kv 400 amps & 3.3 kv 400 amps
]Replacement of Potential transformer 11kv 110 volt operating
Supply and Providing of roller bearing
Replacement of Ampere meter and Volt meter digital type (0-9999V)
Supply and Providing of HRC Fuse with base 63 amps grade with three replacement back up fuse per unit.
Supply and Providing of Power pack unit 110V Ac/Dc with battery bank with input 110Vac out put 110v dc -12 v dc.
Replacement & fxing of current transformer 400/200-5-5-5
Repairing and Rectification of operating mechanism and control circuit Using lugs clips and washer etc. As when and attending of breakdown urgent basis to maintain optimum power supply
Keplacement of main charging spring mechanism for meditron complete Jassembly with motorised spring charge.
supply and Providing of interrepture bushing housing cover 11 kv & 3.3 kv grade
Total impact of GST for the purpose of CTC
M/s Kiran Electrical works (BID ID -1177839)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid