Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
26 Feb 2024, 10:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
je1
Drilling of Borewell and installation of pumpmotor at Anchepalya in CMC Madanayakanahalli Limits
DMA/2023-24/WS/WORK_INDENT14866
DMA/2023-24/WS/WORK_INDENT14866
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
DMA City Municipal Council Madanayakanahalli
9 documents required · 9 mandatory
Satisfactoriy completed (atleast 80%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
similar work done certificate issued by officer not below the executive engineer
Form 7A
Annual Turnover inshould have in the last five years at least two financial years an minimum annual financial turnover Certificate issued by Chartered Accountant
KPWD/CPWD/GovtLicence/ ELECTRICAL Contractor Registration Certificate
Banker Details for reference
MSME Certificate
Line of credit 30 PERCENT of the estimate amount of tender from the nationalized/scheduled bank duly mentioning the name of work
Upload difference amount DD/FDR
NONE
NONE
Contact Address and Phone Number
GST certificate
₹750
₹60,000
11 Feb 2024
11 Feb 2024
27 Feb 2024
17 Feb 2024
Drilling of Borewell and installation of pumpmotor at Anchepalya in CMC Madanayakanahalli Limits
Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner o...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Logging / scanning of borewell at any depth continuously with the help of Logger unit including the cost of transportation charges, crew charges, stationery charges and cost of consumables etc. (sl n...
Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, m...
Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensi...
Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum)....
Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per ne...
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. (sl no ...
Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar...
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well cap...
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog ...
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm (sl no13.25.1 page no 154 Vol-5 Schedule of Rates For 2...
Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any For 50 mm dia GI Union (sl no 11.12.6 page no 131 Vol-5 Schedule of...
Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for: For 50 mm dia GI elbow (sl no11.7.6 page no 129 Vol-5 Schedul...
Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., com...
Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. (sl no13.36 pa...
Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of sa...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( Sl no: ...
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. ( PWD Ele SR 2-23-24 page no 19 of 105 item no 5.35)
Aluminium End Terminal (Lug) 16 Sqmm ( ESCOMs SR 2023-24 page no : 27 of 81 Slno: 470 item no: 60.02 Material Code: 288631
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint...
Supply of PPR Ball Valve Plastic (Heavy Body) confirming to IS 15801- 2008 and DIN Standards 8077/809 PPR Ball Valve Plastic (Heavy Body) 50mm ( Sl no 2.72.5 Schedule of Rates For 2023-24)
Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 63mm dia PVC couplers ( sl no 10.8....
Supply and delivery at site special moulded variety PVC reducer as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 63 mm dia PVC REDUCER (sl no 10.13.5 pa...
Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 63mm dia PVC Tee (sl no 10.10.5 page no 11...
Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 63 mm dia PVC BEND (sl no 10.11.5 page no ...
Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 63 mm dia PVC Elbows ( sl no 10.9.5 page...
Chemical & Reagents Required for Taluka & District Water Quality Testing Laborotary Chemical/ Reagents- STD Fluoride Solution 100 ppm, eagent RD7, NIST trasable standard ( sl no 6.4.7 page no 78 volu...
Chemical & Reagents Required for Taluka & District Water Quality Testing Laborotary pH Buffer solution (Himedia/Merckfor normal pH meter) 7-100 Capsules/500ml ( sl no 6.5 page no 79 volume 5 common SR...
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantle...
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Materia...
Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), c...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW2 30 2.doc
Tender Document • 1.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .