| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹53.0 L+₹2.1 L (4.19%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹53.0 L+₹2.1 L (4.20%)Rejected-Finance VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹54.7 L+₹3.8 L (7.54%)Rejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Other than L1 Bidder |
| Sl No | Description | Qty | Unit | SANJOLI CONSTRUCTION COMPANY L2 | M/S PRASHANT BENIWAL L4 | NAGEL ENTERPRISES L3 | AUTOMATION AND SWITCHGEAR PANELS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply,installation,testing & commissioning of 11 KV Outdoor type extensible RMU floor mounted with internal eletrolytic grade copper bus bars, consisting of combinations of 630 Amp 2 Nos. fixed manual Load Break Switch as outgoing & 1 Nos. fixed type manual Vacuum Circuit Breaker as incommer. All live parts, bus bars, LBSs connections of RMU shall be enclosed to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown.RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings,if applicable shall be bolted type top mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes . RMU should be The unit shall be internal arc proof 21kA for 1 sec. for tank+Cable Box ,and tested and totally safe for human beings. The gas release & personnel safety with internal arc proof shall not depend on plinth design in and incuding the following :- | 6 | Each Set | 6,11,100 ₹36,66,600 | 5,61,000 ₹33,66,000 | 5,51,000 ₹33,06,000 Lowest | 5,80,000 ₹34,80,000 |
| 1.01The configuration of the RMU will be 1 VCB (One VCB) as incomer and 2 LBS (Two LBS) as outgoing | |||||||
| 1.02(a) The Vacuum Bottle shall be of same make as that of RMU to ensure better life cycle optimization for the RMU. | |||||||
| 1.03(b) The Manufacturer shall furnish performance Certificate for similar kind of RMUs in their own legal Name . Any Joint venture certificates / partnership with other firms shall not be considered. | |||||||
| 1.04(c ) RMUs, VCB Panels,Outdoor PCVCBs,CRP shall be from one same Manufacturer to ensure ease of maintanance after expiry of warranty period. | |||||||
| 1.05(d) The unit shall include the following with all necessary standard fitting required at site. | |||||||
| 1.06(e) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity Short time withstand current - 21KA/ 3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38kV Impulse withstand voltage - 95kV Nominal operating gas pressure - 1.2 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Fault Passage Indicator-01 Set Snap action mechanism for manual operation and pad-lockable Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 1 Set (R,Y,B) | |||||||
| 1.07(f) 630A VCB module for making & breaking of fault current alongwith Earth Swicth of full making capacity Manual operated 630 A Vacuum circuit breaker having spring stored mechanism.Three position disconnector/earthing switch downstream vacuum circuit-breaker with pad-locking feature. | |||||||
| 1.08(g) Three position single spring mechanism for disconnector/earthing switch with pad-locking feature. | |||||||
| 1.09(h) “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. | |||||||
Tender Value
₹47.6 L
EMD Value
₹95,114
Closing Date
30 Jan 2026, 6:00 pmClosed
CWE (AF) Jaisalmer
HQ CWE (AF) Jaislmer
Special repairs conversion of 4 pole structure to RMU and allied works in Tech area at AFS Jaisalmer
2026_MES_747043_1
80379
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Jaisalmer
₹95,114
10 Jun 2026
2 Jan 2026
31 Jan 2026
2 Jan 2026
30 Jan 2026
23 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,installation,testing & commissioning of 11 KV Outdoor type extensible RMU floor mounted with internal eletrolytic grade copper bus bars, consisting of combinations of 630 Amp 2 Nos. fixed manual Load Break Switch as outgoing & 1 Nos. fixed type manual Vacuum Circuit Breaker as incommer. All live parts, bus bars, LBSs connections of RMU shall be enclosed to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown.RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings,if applicable shall be bolted type top mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes . RMU should be The unit shall be internal arc proof 21kA for 1 sec. for tank+Cable Box ,and tested and totally safe for human beings. The gas release & personnel safety with internal arc proof shall not depend on plinth design in and incuding the following :- | 6 | Each Set | - | - |
| 1.01 | The configuration of the RMU will be 1 VCB (One VCB) as incomer and 2 LBS (Two LBS) as outgoing | - | - | - | - |
| 1.02 | (a) The Vacuum Bottle shall be of same make as that of RMU to ensure better life cycle optimization for the RMU. | - | - | - | - |
| 1.03 | (b) The Manufacturer shall furnish performance Certificate for similar kind of RMUs in their own legal Name . Any Joint venture certificates / partnership with other firms shall not be considered. | - | - | - | - |
| 1.04 | (c ) RMUs, VCB Panels,Outdoor PCVCBs,CRP shall be from one same Manufacturer to ensure ease of maintanance after expiry of warranty period. | - | - | - | - |
| 1.05 | (d) The unit shall include the following with all necessary standard fitting required at site. | - | - | - | - |
| 1.06 | (e) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity
Short time withstand current - 21KA/ 3 sec
Making Capacity - 52.5kAp
Auxiliary contacts - 1NO + 1NC
Power frequency withstand voltage - 38kV
Impulse withstand voltage - 95kV
Nominal operating gas pressure - 1.2 Bar abs.
Front cover mechanism - IP2X
Cable covers - 3X Fault Passage Indicator-01 Set
Snap action mechanism for manual operation and pad-lockable
Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable
Right angle non-touch proof Termination boots - 1 Set (R,Y,B) | - | - | - | - |
| 1.07 | (f) 630A VCB module for making & breaking of fault current alongwith Earth Swicth of full making capacity Manual operated 630 A Vacuum circuit breaker having spring stored mechanism.Three position disconnector/earthing switch downstream vacuum circuit-breaker with pad-locking feature. | - | - | - | - |
| 1.08 | (g) Three position single spring mechanism for disconnector/earthing switch with pad-locking feature. | - | - | - | - |
| 1.09 | (h) “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_836544.xls
BOQ • 0.31 MB
Tender.pdf
Tender Documents • 0.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .