Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹48.2 L+₹13.1 L (37.2%)Rejected-Finance KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Being other than lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
6 Jul 2024, 6:00 pmClosed
GE (I) 866 EWS Carnicobar
GE(I)866 EWS CARNICOBAR PIN-913866 C/O 99APO
PROVISION OF RING MAIN PIPE LINE ALONGWITH CONNECTED ITEMS AT MAIN PUMP HOUSE AT AF STN CARNICOBAR
2024_MES_650402_2
8689/E8
Open Tender
Civil Works
Item Wise
180 days
GE (I) 866 EWS Carnicobar
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) 866 EWS
₹78,000
Yes
7 Oct 2024
4 Jun 2024
13 Jul 2024
4 Jun 2024
6 Jul 2024
17 Jun 2024
Amount
Material, Labour and T&P for fabrication of MS Header system using MS pipe of dia 300 mm heavy duty of length 12 Mtrs, with flanged dead ends, including making provision for cutting of holes of suitable dia and welding MS tail pieces of 1.5 m length each suitable for various pipe sizes with one end flanged for incoming and outgoing connections, including testing for leakages, painting with two coats of synthetic enamel paint over a coat of red oxide zinc primer complete all as specified and directed by Engineer-in-Charge.
Incoming Connections:- (a) 150 mm dia - 02 Nos (b) 200 mm dia - 01 Nos Outgoing Connections:- (a) 150 mm dia - 05 Nos (b) 100 mm dia - 01 Nos (c) 80 mm dia - 01 Nos (d) 50 mm dia - 01 Nos Note :- 1. MS pipe for header system and pipes & fittings beyond 1.5m length of tail pieces shall be measured and paid separately under relevant items of BOQ. 2. Excavating earthwork and returning filling shall be measured and paid separately under relevant items of BOQ.
Supply and lay MS ERW Pipes heavy grade, 8 mm thickness with all fittings, welding branch connections, including painting with anti corrosive paint, laid in floors or fixed to walls as per site requirement of size 300 mm dia Conforming to IS: 1239 (part-I) 2004 & IS 3589 all as specified and directed.
All as per item No. 2.00 above but 200 mm dia, 8 mm thickness
All as per item No. 2.00 above but 150mm dia, 6 mm thickness
All as per item No. 2.00 above but 100mm dia, 6 mm thickness
All as per item No. 2.00 above but 80mm dia, 6 mm thickness
Supply, laying, jointing, commissioning & testing in repairs of ductile iron water mains with flanged ends centrifugally cast of class K-9, and wall thickness 6mm and conforming to IS "8329"(2000) complete all as specified and directed of following bore sizes :- (Note:- Rubber gasket joints and DI specials/fittings shall be measured and paid separately)
100 mm bore size
150 mm bore size
M&L for testing flanged pipe joints in repairs with 3mm thick rubber gasket (packing ring) including provision of suitable size bolts, nuts & washers complete for following bore pipe all as specified and directed by Engineer-in-Charge.
100 mm bore size
150 mm bore size
Supply and fixing nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type for new ductile iron water mains with flanged ends centrifugally cast of class K-9 complete all as specified and directed by Engineer-In-Charge
M & L for GI steel water tubing of 150 mm dia, medium grade, with all necessary fittings(socket, bends, elbows, tees, short pieces, connector, caps, plugs & union, fixing clips etc) laid in trenches/ fixed to walls/ on floors including taking down of existing unserviceable pipes complete all as specified and directed by Engineer-in-Charge.
All as per item No. 10.00 above but 100 mm dia
All as per item No. 10.00 above but 80mm dia
All as per item No 10.00 above but 50mm dia
All as per item No. 10.00 above but 25mm dia
Supply & fixing sluice valve class PN 1.6 250mm dia complete all as specified and directed by Engineer-in-Charge.
Supply & fixing sluice valve class PN 1.6 200mm dia complete all as specified and directed by Engineer-in-Charge.
Supply & fixing sluice valve class PN 1.6 150mm dia complete all as specified and directed by Engineer-in-Charge.
Supply & fixing sluice valve class PN 1.6 100mm dia complete all as specified and directed by Engineer-in-Charge.
Supply & fixing sluice valve class PN 1.6 80mm dia complete all as specified and directed by Engineer-in-Charge.
S&F Non Return Sluice Valve 100 mm diacomplete all as specified and directed by Engineer-in-Charge.
S&F Non Return Sluice Valve 150 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix of Gun-metal, globe or gate valves, of 50 mm dia, with iron wheel head, screwed both ends for iron pipe and fixed including taking down of old worn out valve complete all as specified and as directed .
All as per item No. 22.00 above but 25 mm dia
All as per item No. 22.00 above but 15mm dia
M&L for fittings such as bends (any type, radius and angle) tapers and type,(straight,bend,increaseing,decreasing or double socket etc) Tee pieces single branch 'Y' junctions, double branch, cross (all sockets/ flanged or socket and spigot/flanged) collars, caps and plugs etc including cutting of pipes at site for insertion of fitting complete as reqd at site from 50mm to 300mm bore all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5mtr depth and getting it out in soft/loose soil including forming bottom surface to required level for laying of GI pipe lines complete all as specified and as directed .
Returning, filling in excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 20cm complete all as specified and as directed .
Removing surplus soil to a distance not exc 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed .
M&L Pre-cast cement concrete block masonry with solid blocks of 1:3:6 type C1 using 20mm graded stone aggregate, exc. 10 cm in width and setting in mortar 1:4 complete all as specified & directed
M&L for rendering 15mm thick cement plaster in CM1:4 on block masonry surfaces finished even and smooth with using extra cement complete all as specified & directed
M&L for cement concrete 1:4:8 type D2 with 40mm graded aggregate in foundations, filling & mass concrete complete all as specified & directed.
M&L for cement concrete B1 1:2:4 (20mm graded aggregate) in sub base floor and paving etc 40mm thick including finishing complete all as specified & directed
M&L for chequered cement concrete coloured tiles with grey cement & pigments of size 25cmx25cmx25mm thick set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified and directed.
M&L for demolition of path/road in ground floors and paving exc 15cm thick below or above ground level road cutting all as specified and directed.
M&L for onsite fabricated structural steel sections including nut bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one undercoat and one finishing coat of paint all as specified and directed.
M&L for taking up or down steel tubing and connections including removal to store complete all as specified & directed 50 to 80 mm dia all as specified and directed.
M&L for taking up or down steel tubing and connections including removal to store complete all as specified & directed 100 mm dia all as specified and directed.
Kakolil Trade Agencies
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .