| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹34.6 L+₹3.9 L (12.6%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹39.1 L+₹8.3 L (27.0%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Aug 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
WELCOME MAINTENANCE OF INTERNAL WIRING AND ACCESSORIES GEYSERS FANS ETC OF MD ACCN AND OTM ACCN OF OFFICERS JCOS AND ORS AT TB II AND DUNKRIK LINES AND MAINTENANCE OF SUMMER APPLIANCES UNDER AGE EM I AT GE CENTRAL KIRKEE.
2022_MES_536400_1
8669/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
TB2 AND DUNKRIK LINE area
Class D Category b(i) and c(i)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹90,000
Yes
28 Aug 2022
7 Jul 2022
4 Aug 2022
7 Jul 2022
2 Aug 2022
21 Jul 2022
7 Jul 2022 - 20 Jul 2022
Amount
NOTE :- Contractor has to submit two years manufacturer's Guarantee certifcate from the certified date of completion for all the light fittings catered in this BoQ.
Material and labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sq.mm (nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories along with one single core green colour PVC insulated 1100 volts grade multi stranded FRLSH copper conductor cable of size 1.5 sq.mm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc including dismantling / taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
Material and labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sq.mm (nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories along with one single core green colour PVC insulated 1100 volts grade multi stranded FRLSH copper conductor cable of size 1.5 sq.mm as earth lead and connected to earth dolly for one 5 Amps socket point on independent board including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket including dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
Material and labour for surface point wiring with two single core PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 1.5 sq.mm (nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories along with one single core green colour PVC insulated 1100 volts grade multi stranded FRLSH copper conductor cable of size 1.5 sq.mm as earth lead and connected to earth dolly for one 5 Amps socket point on same board with other switches including dismantling / taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and as directed.
Material and labour for surface point wiring with two single core PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 1.5 sq.mm (nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH Copper conductor cable of size 1.5 sq.mm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 Nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch etc including dismantling / taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and as directed.
Material and labour for surface point wiring with two single core PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 2.5 sq.mm (nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 2.5 sq.mm as earth lead and connected to earth dolly for one 16 Amps socket power point on independent board including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 Nos cadmium coated screws and cup washer on existing MS concealed box for mounting of switch, socket all as specified and as directed.
Material and labour for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 1.5 sq.mm (nominal area) drawn through in and including PVC casing caping / PVC conduit of suitable size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 1.5 sq.mm as earth lead and connected to earth dolly including dismantling / taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed. NOTE:- Two runs of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Material and labour for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sq.mm (nominal area) drawn through in and including PVC casing caping/PVC conduit of suitable size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 2.5 sq.mm as earth lead and connected to earth dolly including dismantling / taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed. NOTE:- Two runs of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Material and labour for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sq.mm (nominal area) drawn through in and including PVC casing caping/PVC conduit of suitable size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 4.0 sq.mm as earth lead and connected to earth dolly including dismantling / taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed. NOTE:- Two runs of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Material and labour for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sq.mm (nominal area) drawn through in and including PVC casing caping/PVC conduit of suitable size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 6.0 sq.mm as earth lead and connected to earth dolly including dismantling / taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed. NOTE:- Two runs of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Material and labour for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sq.mm (nominal area) drawn through in and including PVC casing caping/PVC conduit of suitable size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 10.0 sq.mm as earth lead and connected to earth dolly including dismantling / taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed. NOTE:- Two runs of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Material and labour for surface submain wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 10.0 sq.mm (nominal area) drawn through in and including PVC casing caping/PVC conduit of suitable size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volts grade multi stranded FRLSH copper conductor cable of size 10.0 sq.mm as earth lead and connected to earth dolly including dismantling / taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed. NOTE:- Four runs of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Supply and fix 5 Amps switch Piano type single pole one way including dismantling and taking down un serviceable one all as specified and as directed.
Supply and fix 5 Amps switch Piano type two way including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix bell push Piano type one way 240 volt including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix socket flush type 6 Amps, 5 pin, 230 volts including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix switch socket combination multipurpose 2-in-1 flush type, 3 pin, 5 Amps, 230 volts including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix switch socket combination multipurpose 2-in-1, flush type, 3 pin 16 Amps and 3 pin 6 Amps, 230 volts including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix lamp holder, insulated body with back plate for batten fitting including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix LED lamp 12 Watt, CDL, B-22 cap, (pin type), 230 volts, PF-0.95 (min) including dismantling / taking out un serviceable one all as specified and as directed.
Supply and fix ceiling rose surface bakelite three terminal including dismantling taking down un serviceable one all as specified and as directed.
Supply and fix call bell electric, ding dong, AC 240 volts, 50 Hz, including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix flush type electronic fan regulator with 5 step type,100 Watts, AC 240 Volts, 50 Hz including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix MCB, single pole, 6 to 32 Amps, 240 volts, 10 KA breaking capacity, ‘’C” curve including dismantling / taking down un serviceable one all as specified and directed.
Supply and fix MCB, SPN 6 to 32 Amps, 415 Volts, 10 KA breaking capacity, ‘’C” curve including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix MCB, four pole, 40 to 63 Amps, 415 Volts including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix sheet metal enclosure two way, including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix MCB distribution board, double door, metal enclosure, SPN, 230 volts, 4 way including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix MCB distribution board, double door, metal enclosure, SPN, 230 Volts, 8 way including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix MCB distribution board, double door, metal enclosure, SPN, 230 Volts,12 way including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix MCB distribution board, double door, metal enclosure, TPN, 415 Volts, 4 way including dismantling taking down un serviceable one all as specified and as directed.
Supply and fix metal plug and socket board with MCB SP 20 Amps, 16 KA including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix PVC rectangular switch board of size 300mmx 250mm x50mm with necessary cutting of slots for mounting switch sockets etc including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix PVC rectangular switch board of size 200mmx 150mm x50mm with necessary cutting of slots for mounting switch sockets etc including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix PVC rectangular switch board of size 175mmx 100mm x50mm with necessary cutting of slots for mounting switch sockets etc including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix PVC rectangular switch board of size 100mmx 100mm x50mm with necessary cutting of slots for mounting switch sockets etc including dismantling / taking down un serviceable one all as specified and as directed.
Supply and fix Hylam sheet 3mm thick on existing concealed MS / CI ractangular or square or round box with 04 Nos cadmium coated screws and cup washer including cutting slots for mounting switch/socket/fan regulator/ batten holder etc including dismantling taking down un serviceable one all as specified and as directed.
Supply and fix round shaped recess mounted LED flat panel, PDC aluminium housing and PMMA difuser 12 watt suitable for POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sq.mm two core copper flexible conductor cable including dismantling / taking down un serviceable fitting any type all as specified and directed. MAKE:- Wipro Cat No. LD95-141-XXX-65-G1 or its techno commercially equivalent in Philips/C&S.
Supply and fix square shaped 2'x2' recess mounted LED flat panel, PDC aluminium housing and PMMA difuser 36 Watt suitable for POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sq.mm two core copper flexible conductor cable including dismantling taking down un serviceable fitting any type all as specified and as directed. MAKE:- Wipro Cat No. CRCO24R036HP65G1 or its techno commercially equivalent in Philips/C&S
Supply and fix LED batten 2 feet long, 10 watt, 230 volts, complete with all accessories internally pre wired and including connecting up to ceiling rose with 0.5 sq.mm two core copper flexible conductor cable with mounting casing box 2 nos including dismantling / taking down un serviceable fitting of any type all as specified and as directed. MAKE:- Wipro Cat No. LL20-111-XXX-65NE3 or its techno commercially equivalent in Philips/C&S
Supply and fix LED tube light fitting, 36 watt, durable LED batten with decorative end caps, 230 volts, 4 feet long, complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sq.mm twin core copper flexible conductor cable including LED lamp and mounting casing box 2 Nos including dismantling taking down un serviceable fitting any type all as specified and as directed. MAKE:- Wipro Cat No. LL22-511-XXX-65-G1 or its techno commercially equivalent in Philips/C&S
Supply and fix LED tube light fitting, 20 watt, integrated LED batten with aluminium housing, 230 Volts, 4 feet long, complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sq.mm twin core copper flexible conductor cable including LED lamp and mounting casing box 2 nos including dismantling / taking down un serviceable fitting any type all as specified and as directed. MAKE:- Wipro Cat No. LL20-281-XXX-65AL1 or its techno commercially equivalent in Philips/C&S
Supply and fix LED batten suitable for 1 x 18 / 20 watts LED tube rod with decorative end caps, white powder coated CRCA body 230 Volts, 4 feet long, complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sq.mm twin core copper flexible conductor cable including LED lamp and mounting casing box 2 nos including dismantling / taking down un serviceable fitting any type all as specified and directed. MAKE:- Wipro Cat No. WIO921208P or its techno commercially equivalent in Philips/C&S
Supply and fix LED tube 18 / 20 watt to LED batten, surface mounted, rewiring with 0.5 sq.mm copper flexible conductor FRLSH to holder and including connecting up to ceiling rose with 0.5 sq.mm two core flexible copper conductor cable all as specified and as directed. MAKE:- Wipro Cat No. LL13-181-65-T5 or its techno commercially equivalent in Philips/C&S.
Supply and fix LED building security light 25 watt, 230 volts complete with all accessories and including connecting up to ceiling rose with 0.5 sq.mm three core copper flexible conductor cable, one GI medium grade 32 mm dia bracket of total length 60cm and fixed to wall with 2 Nos MS clamp and fasteners including dismantling / taking down un serviceable fitting any type all as specified and as directed. MAKE:- Wipro Cat No. LR-02-291-XXX-57-XX or its equilvalent in Philips/C&S.
REPAIRS TO FANS WITH FOLLOWING ITEMS OF WORK :- Material and labour for rewinding of ceiling fan 1200 mm / 1400 mm sweep after dismanting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, varnishing, replacement of un serviceable bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete all as specified and as directed. NOTE:- (i) Contractor will collect fans from the complaint cell of specified area and bring back to complaint cell after repairs. Cost of transportation will be deemed to be included in the quoted rate. (ii) Spares required for replacement such as bearing, bushing, capacitor shall be measured and paid separately under relevent items as supply and fixing. (iii) Cost of connector bock and capacitor holder will be deemed to be included in the quoted rate.
All as per Sl Item No. 48 here-in-before but for exhaust fan 250 / 300 mm sweep industrial type.
Supply and fix ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC complete all as specified and as directed.
Supply and fix gun metal bush bearing for ceiling fan as per existing pattern complete all as specified and as directed.
Supply and fix capacitor AC for 230 volts 50 Hz of capacity 1.5/2.0 Mfd complete all as specified and as directed.
Supply and fix capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd complete all as specified and as directed.
Supply and fix capacitor AC for 230 volts 50 Hz of capacity 4.00 Mfd complete all as specified and as directed.
Material and labour for painting of ceiling fan 1200/1400 mm sweep including scraping, cleaning and removing dust from the blades and body, applying two coats of synthetic enamel paint over one coat of primer by spray painting all as directed.
Supply and fix in repairs of exhaust fan 200mm sweep, PVC body with louvers, 230 volts including dismantling / taking down un serviceable fan of any type all as specified and as directed. MAKE :- Bajaj / Havells / Usha.
Supply and fix in repairs of exhaust fan 250mm / 300 mm sweep, PVC body with louvers, 230 volts including dismantling / taking down un serviceable fan of any type all as specified and as directed. MAKE :-Bajaj / Havells / Usha.
Supply and fix in repairs of exhaust fan 300 mm sweep, metal body with louvers, 230 volts including dismantling / taking down un serviceable fan of any type all as specified and as directed. MAKE:- Bajaj / Havells / Usha.
Supply and fix PVC insulated PVC sheathed, copper flexible cable with multi stranded copper conductor of 4 sq.mm 3 core, ISI marked all as specified and as directed.
Supply and fix in repairs thermostat ISI marked suitable for geysers 25 ltrs to 50 ltrs capacity all as specified and as directed. MAKE :- Bajaj/Venus/Recold
Supply and fix in repairs fusible plug marked suitable for 25 and 50 ltrs capacity Geysers all as specified and as directed.
Supply and fix in repairs heating element ISI marked, round/triangular base, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and as directed.
Supply and fix in repairs innner water container made of stainless steel, vertical or horizontal type for 25/50 ltr capacity gyser all as specified and directed.
Supply and fix in repairs of aparatus plate suitable for vertical/horizintal type Geyser 25 or 50 ltr capacity all as specified andas directed.
Supply and fix in repairs heavy duty copper connection pipe with brass hexagonal adopters at both side 15mm dia and 450mm long for hot water applications all as specified and as directed.
Supply and fix in repairs heavy duty PVC connection pipe with brass hexagonal adopters at both sides, 15mm dia and 450mm long for hot /cold water all as specified and as directed.
Supply and fix PVC meter box made out of 5 mm thick PVC sheet with hinged doors,glass viewer suitable to accommodate up to 10 energy meters and distribution board mounted on wall with provision for incoming and outgoing cable entry all as specified and as directed.
Supply and fix PVC meter box made out of 5 mm thick PVC sheet with hinged doors,glass viewer suitable to accommodate up to 5 energy meters and distribution board mounted on wall with provision for incoming and outgoing cable entry all as specified and as directed.
Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 4 mm dia all as shown in Electrical plate No-2 of SSR Part I, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI lead, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning, filling in and removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion all as specified and as directed.
Material and labour for servicing/maintenance of split type air conditioner 1.5/2.0 ton cap in situ by cleaning of complete outdoor unit and indoor unit, air blower units, air filter, grills with required chemical solution and using forced air blower or vaccuum cleaner, complete checking serviceability of electrical circuit of outdoor and indoor unit, electronic circuit, airblower unit, condenser, remote control unit, including replacement of unserviceable spares such as relays, capacitors, wiring kit, screws, nuts, bolts & washers, remote control unit and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit. Note: (i) Spares require for replacement for minor repair as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate and no extra measurement shall be made. (iii) Items require for major repair shall be measured and paid as Material and labour under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item.
Material and labour for servicing / maintenance of window type air conditioner 1.5 / 2.0 ton capacity in situ by cleaning of complete cooling coil, condenser unit, air blower units, air filter, grills with required chemical solution and using forced air blower or vaccuum cleaner, complete checking the serviceability of electrical circuit of unit, air blower unit, condenser, cooling coil, thermostat, copper tubings, including replacement of unserviceable spares such as relays, capacitors, thermostat, wiring kit, screws, nuts, bolts & washers,and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit all as specified and as directed. NOTE :- (i) Spares required for replacement for minor repairs as mentioned shall be measured and paid as supply only under relevant items of this BoQ and labour charges shall deemed to be included in the quoted rate of this item. (ii) Screws, nuts, bolts and washers shall be inclusive of quoted rate and no extra measurement shall be made. (iii) Items required for major repairs shall be measured and paid as Material and labour under relevant items of this BoQ and rate shall be exclusive of quoted rate of this item.
Supply only following (Sl Item No. 70 to 81) company recommended spares of split / window type air conditioner of 1.5 /2.0 ton capacity suitable for AC of make Blue Star, LG, Hitachi, Voltas, Samsung, Shriram Usha, Feeder Lloyed & Carrier whichever applicable complete all as specified and as directed. (a) Running capacitor 45 to 60 mfd
(b) Starting capacitor 120-150mfd / 150-200 mfd.
(c) Starting relay suitable for reciprocating compressor.
(d) Thermostat switch for window type AC.
(e) Condenser fan blade for window/split type AC made of plastic/aluminium
(f) Remote control unit as per original make complete with 2 Nos Duracell battery.
(g) Plastic grill with louvers front panel for window AC as per original make and model,
(i) Air filter suitable for indoor unit of split type AC 1.5 /2.0 TR capacity
(j) Air filter suitable for window type AC 1.5 /2.0 TR capacity.
(k) Flexible PVC drain pipe 15/20mm bore.
Supply and fix new company sealed rotary compressor unit suitable for split type AC 1.5 TR capacity with required nuts, bolts and washers, connecting necessary copper tubing by gas welding, gas charging with R-22, replacement of capilary tube and drier filter after dismantling / taking out existing unserviceable / burnt compressor unit from the split type air conditioner 1.5 ton capacity in situ and testing after completion to entire satisfaction of Engr-in-Charge. MAKE:- Blue Star/ LG/ Hitachi/ Voltas/Samsung. NOTE:- (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate items of this BoQ. (iii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply & fix new company sealed rotary compressor unit suitable for split type AC 2 TR Cap with required nuts, bolts & washers, connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of capilary tube and drier filter after dismantling/taking out existing unserviceable/burnt compressor unit from the split type airconditioner 2.0 Ton cap in situ and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE:- Blue Star/ LG/ Hitachi/ Voltas/Samsung . NOTE :- (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (iii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix new company sealed reciprocating compressor unit suitable for window type AC 1.5 TR capacity with required nuts, bolts & washers, connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of capilary tube and oil filter after dismantling / taking out existing unserviceable / burnt compressor unit from the window type air conditioner 1.5 ton capacity in situ and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- Blue Star/Voltas/ Feeder Lloyd/ Shriram/ Usha/Carrier. NOTE :- (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (iii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix new company sealed reciprocating compressor unit suitable for window type AC 2 TR capacity with required nuts, bolts and washers, connecting necessary copper tubing by gas welding, gas charging with R-22, replacement of capilary tube and oil filter after dismantling / taking out existing unserviceable / burnt compressor unit from the window type air conditioner 2.0 TR capacity in situ and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- Blue Star/Voltas/ Feeder Lloyd / Shriram / Usha / Carrier. NOTE :- (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (iii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix new blower motor with required nuts, bolts and washers, connecting necessary wires, fixing of fan complete after dismantling / taking out existing unserviceable / burnt blower motor unit from the window type air conditioner 1.5 / 2.0 ton capacity in situ suitable for window type AC of any make and testing after completion to entire satisfaction of Engr-in-Charge.
Supply and fix new blower motor, 230 volts, 950 to1350 RPM with required nuts, bolts and washers, connecting necessary wires, fixing of fan complete after dismantling / taking out existing unserviceable / burnt blower motor unit from the outdoor unit of split type air conditioner 1.5 / 2.0 ton capacity in situ of any make and testing after completion to entire satisfaction of Engr-in-Charge.
Supply and fix electronic circuit board (PCB) suitable for 1.5/2.0 ton window type AC as per existing one after dismantling / taking out un servioceable PCB and testing complete suitable for window type AC of any make complete all as specified and as directed. NOTE:- (i) PCB unit shall be compitable model and make as recommended by the manufacturer of AC. (ii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix electronic circuit board (PCB) suitable for 1.5/2.0 ton split AC as per existing one after dismantling taking out un serviceable PCB and testing complete suitable for split type AC of any make complete all as specified and as directed. NOTE:- (i) PCB unit shall be compitable model and make as recommended by the manufacturer of AC. (ii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix condenser coil unit of window type AC of 1.5 ton capacity in situ as per existing make and competable model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling / taking out existing unserviceable condenser unit suitable for AC of Make :- Blue Star, Voltas, Feeder Lloyed, Shriram, Usha and Carrier whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- Gas charging shall be measured and paid separately under appropriate item of this BoQ.
Supply and fix condenser coil unit of window type AC of 2.0 ton capacity in situ as per existing make and compatible model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling / taking out existing unserviceable condenser unit suitable for window type AC of any make and testing after completion to entire satisfaction of Engr-in-Charge. NOTE:- Gas charging shall be measured and paid separately under appropriate item of thisBoQ.
Supply and fix cooling coil unit of window type AC of 1.5/2.0 ton capacity in situ as per existing make and compatible model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling / taking out existing unserviceable cooling coil unit suitable for window type AC of any make and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- Gas charging shall be measured and paid separately under appropriate item of this BoQ.
Supply and fix outdoor unit of split type AC of 1.5 ton capacity in situ as per existing make and compatible model without compressor but including blower motor and fan, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :--Blue Star, LG, Hitachi, Voltas & Samsung. NOTE:- (i) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (ii) Compressor unit shall be measured and paid separately under appropriate item of this BoQ
Supply and fix outdoor unit of split type AC 2.0 Ton capacity in situ as per existing make and compatible model without compressor but including blower motor, fan connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling / taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge. MAKE:- Blue Star, LG, Hitachi, Voltas & Samsung. NOTE:- (i) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (ii) Compressor unit shall be measured and paid separately under appropriate item of this BoQ.
Supply and fix indoor unit of split type AC of 1.5 ton capacity complete with cooling unit, PCB, blower unit with motor, swing motor, remote unit in situ as per existing make and compatible model complete, connecting necessary electrical connections and copper tubings by gas welding, gas charging with R-22, after dismantling / taking out existing unserviceable indoor unit suitable for split type AC of Make :- Blue Star, LG, Hitachi, Voltas & Samsung and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Gas charging shall be measured and paid separately under appropriate item of this BoQ.
Supply and fix indoor unit of split type AC of 2.0 ton capacity complete with cooling unit, PCB, blower unit with motor, swing motor, remote unit in situ as per existing make and compatible model complete, connecting necessary electrical connectons and copper tubings by gas welding, gas charging with R-22, after dismantling / taking out existing unserviceable indoor unit suitable for AC of Make :- Blue Star, LG, Hitachi, Voltas & Samsung and testing after completion to entire satisfaction of Engr-in-Charge. NOTE:- (i) Gas charging shall be measured and paid separately under appropriate item of this BoQ.
Supply and fix louvers swing motor suitable for window type AC of capacity 1.5 / 2.0 ton capacity in situ as per existing make and compatible model, necessary electrical connection and conection with louvers, after dismantling / taking out existing unserviceable unit suitable for AC of MAKE :- Blue Star, Voltas, Feeder Lloyed, Shriram, Usha & Carrier whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge.
Supply and fix louvers swing motor suitable for indoor unit of split type AC of 1.5/2.0 ton capacity in situ as per existing make and compatible model, necessary electrical connections after dismantling / taking out existing unserviceable unit suitable for AC of make :- Blue Star, LG, Hitachi, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge.
Material and labour for servicing / maintenance of water cooler of cooling capacity 40/ 60/ 80/ 120 LPH any storage capacity in situ by cleaning of complete cooling coil, condenser unit, air blower units, grills, external body surface, internal body surface with required chemical solution and using forced air blower or vaccuum cleaner, cleaning of water storage tank, checking serviceability of electrical circuit of unit, airblower unit, condenser, cooling coil, thermostat, copper tubings, operating knobs, push cocks, drain trays, drain pipes, float valves, relays, OL protector including replacement of unserviceable spares such as relays, OL protector, capacitors, thermostat, wiring kit, operating knobs, push cocks, float valves, screws, nuts, bolts & washers of water cooler of any make and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Spares required for replacement on minor repairs as mentioned shall be measured and paid as supply only under appropriate item of this BoQ and labour charges shall be deemed to be included in the quoted rate of this item. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate and no extra measurement shall be made. (iii) Items required for major repairs shall be measured and paid as material and labour under appropriate item of this BoQ and cost of the same shall be exclusive of quoted rate of this item.
Supply only following (Sl item No. 99 to 108) company recommended spares of water cooler of capacity 40 / 60 / 80 / 120 LPH suitable for make- Usha, Voltas, Blue Star complete all as specified and as directed. (a) Over load protector (OLP)
(b) Starting relay
(c) Thermostat
(d) Starting capacitor 40/60 mfd
(e) Starting capacitor 80-100 mfd
(f) Running capacitor 4 to 25 mfd
(g) Drain hose pipe 20mm to 30mm dia plastic
(h) CP push cock 15 mm dia
(i) PVC float valve 15mm dia
(j) PVC/aluminium fan for condenser blower motor
Supply and fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of capilary tube and oil filter after dismantling / taking out existing unserviceable / burnt compressor unit from the water cooler 40LPH / 80LPH (cooling/storage) capacity in situ and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- Usha, Voltas & Blue Star NOTE :- (i) Compressor unit shall be 1st quality with compatible model and make of compressor shall be as recommended by the manufacturer of water cooler. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (iii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of capilary tube and oil filter after dismantling / taking out existing unserviceable / burnt compressor unit from the water cooler 120 LPH / 150 LPH (cooling/storage) capacity in situ and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- Usha, Voltas & Blue Star NOTE :- (i) Compressor unit shall be 1st quality with compatible model and make of compressor shall be as recommended by the manufacturer of water cooler. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (iii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix condenser coil unit of water cooler 40/80L capacity as per existing make and compatible model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling / taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge suitable for water cooler of any make. NOTE :- (i) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (ii) Make of item shall be as recommended by OEM.
Supply and fix condenser coil unit of water cooler 120/150L capacity as per existing make and compatible model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling / taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge suitable for water cooler of any make. NOTE :- (i) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (ii) Make of item shall be as recommended by OEM.
Supply and fix new condenser fan motor with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismantling / taking out existing unserviceable / burnt fan motor unit from the water cooler of cooling capacity 40/80L to 120/150L in situ and testing after completion to entire satisfaction of Engr-in-Charge suitable for water cooler of Make-Usha, Voltas or Blue Star. NOTE :- Make of item shall be as recommended by the OEM
Supply and fix drain tray made stainless steel with required nuts, bolts or screws suitable for any capacity of water cooler including dismantling / taking out unserviceable one complete all as specified and as directed. MAKE :-Usha, Voltas or Blue Star. NOTE :- Make and size of item shall be as recommended by OEM.
Material and labour for base frame as per sample suitable for 40/80 Ltrs water cooler made out of MS angle iron, flats, cut to required length, making necessary shape, screw holes, fixing with necessry electric welding, painting with one coat of red oxide and two coats of synthetic enamel paint at all sides of the steel member complete all as specified and as directed.
Material and labour for base frame as per sample suitable for 80/120 Ltrs,120/150 ltrs water cooler made out of MS angle iron, flats, cut to required length, making necessary shape, screw holes, fixing with necessry electric welding, painting with one coat of red oxide and two coats of synthetic enamel paint at all sides of the steel member complete all as specified and as directed.
Supply only following( Sl item No. 118 to 125) spares of desert cooler of any capacity after dismantling / taking out un serviceable of Make -Simphony/ Voltas whichever is applicable all as specified and as directed. (a) Wiring kit.
(c) PVC float valve 15mm dia.
(d) Natural grass pad (set of 3)
(e) Blower motor of suitable capacity including necessary electric connections, mounting nuts, bolts and washers.
(f) PVC fan blade for blower motor
(g) Water spray pump
(h) PVC flexible pipe 6mm to 10mm dia.
Material and labour for servicing / maintenance of refrigerator of any capacity in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete checking serviceability of electrical circuit of unit, thermostat knob, fans if provided in frost free model, relays, thermostat, trays including replacement of unserviceable spares such as relays, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge for any make of refrigerator complete all as specified and as directed. NOTE :- (i) Spares required for replacement on minor repairs shall be included in quoted rate (ii) Items required for major repairs shall be measured and paid as separately under relevant items of BoQ .
Supply only Starting relay for refrigerator of any capacity after dismantling / taking out un serviceable one complete all as specified and as directed. MAKE :- Godrej/Whirlpool/Videocon/LG .
Supply only Thermostat for refrigerator of any capacity after dismantling / taking out un serviceable one complete all as specified and as directed. MAKE :- Godrej/Whirlpool/Videocon/LG .
Supply and fix new company sealed reciprocating compressor unit for refrigerator of capacity 165 ltr to 310 ltr with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismantling / taking out existing unserviceable / burnt compressor unit from the refrigerator in work shop and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :-Godrej/Whirlpool/Videocon/LG. NOTE :- (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ.
Supply and fix new condenser unit for refrigerator of capacity 165 ltr to 310 ltr with required nuts, bolts & washers, connecting necessary copper tubings by gas welding / brazing, gas charging with R-134A after dismantling / taking out existing unserviceable unit from the refrigerator in situ and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :-Godrej/Whirlpool/Videocon/LG. NOTE :- (i) Condenser unit shall be compatible model and make shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ.
Material and labour for servicing/maintenance of deep freezer of capacity 300L / 310L / 450L of any make in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete and checking serviceability of electrical circuit of unit, condenser unit, relays, thermostat, trays including replacement of unserviceable spares such as relays, capacitors, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Spares required for replacement on minor repairs as mentioned shall be measured and paid as supply only under appropriate item of this BoQ and labour charges shall deemed to be included in the quoted rate of this item. (ii) Items required for major repairs shall be measured and paid separately under relevant items of BoQ.
Supply only following (Sl No. 132 to 140) spares of deep freezer of capacity 300/310/450 Ltr of Make:- Honeydew or Voltas complete all as specified and as directed. (a) Over load protector.
(b) Starting relay
(c) Thermostat
(d) Starting capacitor 40/60 mfd
(e) Starting capacitor 80-100 mfd
(f) Running capacitor 4 to 25 mfd
(g) Sliding trays small as per existing make & model
(h) Sliding trays large as per existing make & model
(g) PVC fan for blower motor
Supply and fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings by gas welding / brazing, gas charging with R-22, replacement of capilary tube and oil filter after dismantling / taking out existing unserviceable / burnt compressor unit from the deep freezer 300/310/450L capacity and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- -Honeydew/Voltas/Bluestar. NOTE :- (i) Compressor unit shall be 1st quality with compatible model and make of compressor shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (iii) Company test certificate and warantee certificate shall be submitted to Dept.
Supply and fix condenser coil unit of deep freezer 300 / 310 / 450 Ltr as per existing make and compatible model, connecting necessary copper tubings by gas welding, gas charging with R-22 after dismantling / taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Gas charging shall be measured and paid separately under appropriate item of this BoQ. (ii) Make of item shall be as recommended by the OEM.
Supply and fix new blower motor with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismantling / taking out existing unserviceable / burnt blower motor unit from the deep freezer of capacity 300/310/450L and and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- Make of item shall be as recommended by the OEM.
Material and labour for refrigerant gas charging for split type AC of cap 1.5 TR/2 TR with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge.
Material and labour for refrigerant gas charging for window type AC of capacity 1.5 / 2 TR with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attain proper cooling level to entire satisfaction of Engr-in-Charge.
Material and labour for refrigerant gas charging for water cooler of cap 40/80 to 120/150 LPH with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attain proper cooling level to entire satisfaction of Engr-in-Charge.
Material and labour for refrigerant gas charging for deep freezer of capacity 300/310/450L with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attain proper cooling level to entire satisfaction of Engr-in-Charge.
Material and labour for refrigerant gas charging for refrigerator of capacity 165 L to 310 l with R-134A gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attain proper cooling level to entire satisfaction of Engr-in-Charge.
Material and labour for painting water cooler body of any capacity by spray painting after preparation of surface with existing colour complete all as specified by Engr -in-charge.
Material and labour for painting of outdoor unit of split A/C of any capacity by spray painting after preparation of surface with existing colour complete all as specified and as directed by Engr -in-charge.
Material and labour for numbering of cooling appliances( window/split A/C's, water coolers, deep freezers, fridge etc in situ up to 10 mtr installed height with the help of ladder etc with white colour in black back ground up to 10 cm width and height all as directed by the Engr-In-Charge.
Material and labour for dismantling un serviceable voltage stabiliser for repairs including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, varnishing and testing after repair complete for capacity 1 KVA to 2 KVA of any make all as specified and as directed.
Material and labour for dismantling un serviceable voltage stabiliser for repair including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, vernishing and testing after repair complete for capacity 3 KVA to 5 KVA of any make all as specified and as directed.
ASHWAMEDH ENGINEERS
ONKAR ELECTRIC AND GENERAL STORE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .