Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.4 L+₹2.4 L (11.0%)Rejected-Finance JYOTINAGAR WEST NEAR HOLLY CHILD SCHOOL GUWAHATI 7810212 ASSAM | KAMRUP METRO | ASSAM | 781021 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹26.2 L+₹4.2 L (19.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹26.3 L+₹4.3 L (19.5%)Rejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹24.1 L
EMD Value
₹48,300
Closing Date
21 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Narangi
GE Narangi C/o 99 APO
PROVN OFLADIES TOILET FOR WMPS AND SPL REP TO BLDG NO T 12 UNDER GE NARANGI
2023_MES_624433_1
8915/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹48,300
Yes
11 Dec 2023
21 Oct 2023
23 Nov 2023
21 Oct 2023
21 Nov 2023
3 Nov 2023
Amount
Excavation in trenches n.exc 1.5m wide and not exceeding 1.5 m in depth for foundation etc, or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil etc complete all as specified and as directed.
M&L surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft / loose soil etc complete all as specified and as directed.
Removing of surplus excavated material not exc 50m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and as directed.
M&L for hardcore of broken or boulders of gauge not exceeding 63mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed.
M&L for hardcore of broken or boulders of gauge exceeding 63mm but not exceeding 100mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed.
M/L PCC 1:3:6 type C-2 ( 40mm graded aggregate) as in concrete bed to drain pipe 110 mm dia including packing under , and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L Precast RCC1:2:4 Type B-1 ( Using 20mm graded stone aggregate) as in landings, cover slabs ( for manhole etc) chullah hoods, chajjas , water toughs, mangers, shelves and similar articles with plain faces set in CM 1:6 complete all as specified and directed.
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundation filliing and mass concrete complete all as specified and as directed.
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundation filliing and mass concrete complete all as specified and as directed.
M&L PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) in surface channel and drain including form work complete all as specified and as directed.
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) in coping/benching including form work complete all as specified and as directed.
M&L for RCC 1:2:4 type B1(20mm graded stone aggregate) nominal mix as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete etc complete all as directed.
M&L for RCC 1:2:4 type B1(20mm graded stone aggregate) nominal mix as in Columns, pillars, piers, posts and struts etc.complete all as specified as directed.
M&L for RCC 1:2:4 type B1(20mm graded stone aggregate) nominal mix as in beams, seimic bands, cantilevers, bressumers and lintels complete all as specified as directed.
M&L RCC 1:2:4 type B1(20mm graded stone aggregate) nominal mix as in slabs supported on walls , beams and columns in floors, roofs, landings, balconies, casnopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete etc complete all as directed.
M&L for reinforced cement concrete M-25 design mix as in beams, seimic bands, cantilevers, bressumers and lintels complete all as specified as directed.
M&L for reinforced cement concrete M-25 design mix as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in chajjas complete all as specified and directed.
M & L for 75 mm thick PCC 1:4:8, type D2 (using 40 mm graded stone aggregates) as in sub base complete all as specified and as directed.
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified as directed.
M&L Formwork to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified as directed.
M&L Formwork to chajjas, chullahoods, troughs and similar items including edges complete all as specified as directed.
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for mild steel TMT bars 6 mm dia and over upto and including 8mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillar including coping etc. complete all as specified and as directed.
M&L for brick work with old size sub class 'B' bricks straight or curved on plan exc. 6m mean radius and built in CM 1:6 etc complete all as specified as directed.
All as per item No. 31 above but except bricks. complete all as specified as directed. Note : Serviceable bricks shall be obtained from demolition of old bricks here in before
M & L for half brick work with sub class 'B' bricks old size (locally available best quality) straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and as directed.
M & L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:- (i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 mixed with water ptoofing compound @ 3% of weight of cement or as per manufactures instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (ii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (iv) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm.
Dismantling timber fillets, rails, posts, rafters, purlins etc. under 40 sqcm in section in any position complete all as specified and directed
Dismantling timber scantlings 40 sq. cm and over in section (unframed work), in any position complete all as specified & as directed.
S&F 20mm thick second class hardwood boarding planed one side with butt joints complete all as specified & as directed.
M&L second class hardwood weather boarding clean sawn, plain 20mm thick or feather edged 15mm to 20mm thick fixed with 30mm laps complete all as specified & as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each including builders hardware complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed.
M&L for 1.25mm thick factory made pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including and providing PCC 1:3:6 type C-0 as in filling the hollow portion of the frame complete all as specified and directed.
S&F factory made single extruded WPC( Wood Polymer Composite) solid plain flush door shutter of 30mm thick comprising of virgin PVC polymer of K value 58-60 ( Suspension grade), calcium carbonate and natural fibres ( Wood powder/Rice husk/Wheat husk) and non toxic additives ( maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum, screw withdrawl strength of 1800N ( Face) and 900N ( Edge) , minimum compressive strength of 50N/sqmm modules of elasticity 850N/sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water / moisture proof and fire retardent and fixed with SS butt hinge of required size with necessary full body threaded star headed counter sunk SS screws. ( SS buttt hinge and necessary SS screws shall be measured and paid seperately) .
S & F Factory made single extruded WPC ( Wood polymer composite) solid door/window/ ceosetory windows and other frames/chowkats of size 50X100mm comprising of virgin PVC polymer of K value 58-60 ( Suspension grade), calcium carbonate and natural fibres ( wood powder/rice husk/wheat husk) and non toxic additives ( maximum toxicity index of 12 for 100 gms) febricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawl strength of 2200 N ( face) and 1100 N ( Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardent and fixed in position with MS hold fast/lugs/SS desh fastener of required dia and length complete . ( Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be admissible. Variation of profile dimension on plus side shall be accepted with ny price adjustment. MS hold fast/Lugs or SS dash fastener shall be measured and paid seperately).
S & F steel ventilators and windows fixed type , with glazing bars dovetailed or welded ready for wire mesh/glass pan fixing complete all as specified and as directed.
S&F steel window with side hung shutters glazed shutter including both side openable ( Out side glazed window and inside flyproof window) including projecting type hinges with steel handle and steel peg stay with glazing bars and 12 mm square bar or round bar of approved design welded to steel window frame dovetailed or welded complete all as specified & as directed .
S&F 35mm thick flush shutter, solid core construction with block board core and plywood face panel, commercial type on both side complete all as specified and directed.
S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed.
S&F mild steel Framed work such as grills, gratings, angle iron, mild steel sheets, mild steel round bar, MS flat iron etc.. for chowkhats or doors shutters or windows etc with ends of bars shouldered and/or riveted, wlded or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F 100mm size stainless steel butt hinges, medium weight, and fixed etc complete all as directed.
S & F Mild Steel butt hinges 100 mm size, medium weight cold rolled and fixed complete all as specified and as directed.
S&F 150 mm size aluminum anodised, barrel tower bolts of extruded section etc complete all as directed.
S&F 200 mm size aluminum anodised, barrel tower bolts of extruded section etc complete all as directed.
S&F 100 mm extruded aluminum alloy handles, febricated type, anodized all as specified and directed.
S&F 150 mm extruded aluminum alloy handles, febricated type, anodized all as specified and directed.
S&F stain less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or aluminum wire staples complete all as specified and directed.
S & F4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane frosted on both sides complete all as specified and as directed.
Taking down roof trusses, coupled rafters of clear span above 4.00m and upto 8.00m complete all as specified and as directed.
Dismantling of asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridge complete all as specified & as directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated galvalume trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated galvalume plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and directed. Note: To be executed for provision of ridges and hips.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified & as directed.
Demolition of cement concrete ( unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M & L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded stone aggregates) as in path / paving / hard standing / floor and finished the surface even and smooth without using extra cement complete all as specified and as directed.
M & L for 100 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregates) as in sub base complete all as specified and as directed.
M & L for 40 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregates) as in sub base complete all as specified and as directed.
M & L for coloured Non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 450x300x7mm/200X300X7mm thick / 300X450X7mm thick set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
M&L for 18 to 20 mm thick granite (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and the like including pointing in white cement 1:2 using granite dust with admixture of pigment to match with the shade of granite work including rounding of exposed edges of granite over and including 15mm thick backing coat in cement mortar 1:4 complete all as specified and as directed.
M&L Prepolished cement concrete chequrred tiles coloured of size 30cmx30cmx25mm thick machine pressed , set and jointed and pointed in neat cement slurry with grey cement and pigments including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for 18-20mm thick Kota stone slab flooring laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for 18-20mm thick Kota stone slab in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 10 mm thick screed bed in CM 1:3 complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on fair faces of RCC concrete surfaces and including applying cement slurry in bottom of slab, chajjas, fin, facias etc. complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M&L for 15 mm thick rendering in CM 1:4 on brick/ concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer including a coat of wall care putty of minimum average thickness 1mm complete all as specified and as directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
S&F powder coated aluminium alloy 20mm dia tubular curtain rod including brackets, stops, rollers etc. complete all as specified and as directed
S&F in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F GI tubing 20 mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
M/L cutting chases , pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc. and making good , cutting not exceeding 10cm girth complete all as specified and directed.
Cutting into existing manholes for connecting new drain pipe of any size making good to pipe and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 th section) in cement concrete 1:2 :4 type B-1 smooth finished and reforming benching as required for 100mm dia ( internal ) pipe complete all as specified and directed.
S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed.
S&F Bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F two way Bib taps 15mm dia cast copper alloy chromium plated, with operating knob and wall flange screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S & F stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed.
S & F 15 mm bore brass chromium plated pillar taps swan neck, with fittings complete all as specified and as directed.
S & F vitreous china, table top wash hand basin, round 430mm dia including waste pipe and CP coupling etc.complete all as specified and as directed
S&F brass chromium plated tubular towel ring with brass chromium plated brackets complete all as specified and as directed.
S&F brass chromium plated tubular towel rail of 20mm dia and 60cm in length, D shaped, with brass chromium plated brackets complete all as specified and as directed.
S&F stainless steel grating doom 100mm dia with waste hole complete all as specified and as directed.
S&F stainless steel grating doom 100mm dia complete all as specified and as directed.
S&F CI floor trap 100mm outlet with grating including jointing to waste pipe fixed in cement concrete type B-1 ( 1:2:4). complete all as specified and directed.
S&Fhealth faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connection and fixing in position complete all as specified & as directed.
S & F toilet paper holder chromium plated fixed to wall with chromium plated bracket complete all as specified and as directed.
S&F PVC low level flushing cistern 10 litres capacity with inlet ball valve, float and handles including brackets complete all as specified and directed.
S & F vitreous china wash down water closet (pedestal pattern) including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws etc complete all as specified and as directed
S&F glass shelf of size 500 X 125mm with chromium plated guard rail below mirror for keeping soap box complete all as directed.
S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed
S&F 110mm dia PVC (SWR) bends of any radius complete all as specified and as directed.
Taking down carefully aluminium/ copper point wiring for light/fan/ socket/bell or power point including . all fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete removing materials to store for keeping in safe custody site or handed over to contractor as schedule of credit and making good disturbed surfaces of walls, floors, etc complete all as directed.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 laid and fixed including PVC rigid conduit( concealed) with all accessories including febricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screws for mounting switches, sockets, regulators etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 110 here-in-before but for one 3 pin 5 Amp switch socket outlet on same board with other switches.
All as per item No 110 here-in-before but for one 3 pin 5 Amp switch socket outlet on independent board
All as per item No 110 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F switch piano, flush type single pole one way 5 Amps 240 volt complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F lamp holder insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F LED light fitting of approved make 1X 20 W, 220V, AC decorative batten type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F in repair LED light fitting of approved make 1X 20 W, 220V, AC decorative batten type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F LED 35 W building security light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed .
S&F in repair LED 35 W building security light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed .
M&L for building secruity light bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape for fixing street light luminaries all as directed, length of GI Pipe shall not be less than 2.0 mtrs complete all as specified and directed.
S&F in repair LED luminaire 600X600mm, 35/36 Watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamps suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size complete all as directed.
S&F in repair LED light fitting of approved make mirror type with high output diffuser 2 feet, 10 W, 220V, AC decorative type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F LED light fitting of approved make mirror type with high output diffuser 2 feet, 10 W, 220V, AC decorative type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F in repair Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED 9/10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed.
S&F Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED 9/10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed.
S & F SPN DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.
S & F in repair SPN DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F MCBs, SPN 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
Supply, fixing and testing in repair of vertical wall mounted Storage type electric water heater of capacity 25 ltrs with BEE 5 star rated, 230 V, maximum power consumption 2 KW, Drypowder Fero Glass coating Technology for inner container with Heavy Duty seamless Incoloy 800 Glass lined heating element, and 2 Nos PVC connecting pipe of whirl technology 15 mm bore 450mm long for hot and cold water supply complete with all accesories and all as specified and directed .
S&F in repair ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep minimum air delievery 210 CFM with service value 6.. BEE five star rated with brushless direct current motor ( BLDC) complete all as specified and directed.
S&F of Exhaust fan made of sturdy Engineeering plastic complete with louver shutter, 230V, 50 Hz, RPM 1200 300mm sweep copper winding complete all as specified and directed.
S&F in repair Exhaust fans AC single phase 230/ 240 V ,50 Hz metallic heavy body of size 450 mm sweep, 1400 RPM with louver fixing with 4 no hold fastener nut and bolt with washer and connecting with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm including civil work opening on wall of suitable size and 400x400x6mm thick BWR graded plywood making suitable hole for fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and writing MES No. with black synthetic enamel paint with 2cm high letter and making good surface complete all as specified and directed.
Supply, laying and testing of XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 4 core laid in trenches / floor or fixed on wall /pole with brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply, laying and testing of XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches / floor or fixed on wall /pole with brass compression cable glands, terminal lugs etc, complete including taking up/down old cable of any size and description all as specified and as directed.
Supply and spreading fine dry river sand for cushing to UG cable including spreading levelling and hand punning etc complete all as specified and directed.
M&L for sub class 'B' old size bricks laid in trenches for cable protection laid flat width wise along the length of cable complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 .
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including demolition of old earthing.
Rana Kr Phookan
R S TRADERS
S. R. TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .