Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Qualified | Qualified |
| 2 | Qualified | Qualified |
Tender Value
Refer Docs
EMD Value
₹5 Cr
Closing Date
21 Nov 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
KUMAR SIDDHANT DY MANAGER
Power Grid Corporation of India Limited Saudamini 3rd Floor Plot No 2 Sector 29 Gurgaon Haryana 122001
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh.
CC/NT/W-TW/DOM/A06/23/07696
Open
Power/Energy Projects/Products
Works
LADAKH
₹5 Cr
23 Nov 2023
25 Aug 2023
23 Nov 2023
25 Aug 2023
21 Nov 2023
25 Aug 2023
1 Sept 2023
Package Name Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
Package Code Package: TL02 Bought-out
NIT/RFB No NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696
1 Fill up only green shaded cells in Schedule-1 and Schedule-2
2 All the cells in Schedule are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated automatically at the rate mentioned by the bidder here.
● Segregate and fill up the amount on which Sales Tax shall be applicable out of Ex-works supply items mentioned as direct in the mode of transaction in Schedule-1. Applicable Excise Duty on this amount will be calculated automatically at the rate mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of Sales Tax shall be automatically calculated on the amount mentioned by the bidder as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the Bidder.
● Difference of total amount quoted by the bidder as Direct Transaction and the amount mentioned by him subjected to Sales Tax shall be considered as the amount on which VAT shall become applicable and the same shall be calculated & displayed automatically. Applicable Excise Duty on this amount at the rate mentioned by the bidder shall also be calculated & displayed automatically. Fill up the rate of applicable VAT. The amount of VAT shall be calculated automatically on the amount considered to be subjected to VAT plus applicable Excise Duty at the rate mentioned by the bidder here.
● Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be added to the grand total and shall be considered as applicable.
● Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes & Duties one by one.
● Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Fill the description, amount and rate of applicable Octroi. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
Other Taxes & Duties :
● Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid form 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Sole Bidder 1
JV (Joint Venture) Other Partner
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 1 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Schedule-1
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED, 0
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon 0
Address : JOINT VENTURE OF 0 & 0
Supply of Plant (including Mandatory Spare Parts)
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code GST payable on the price quoted if Contract is awarded (%) Description of Goods Unit Qty. Unit Ex- works price Total Ex-Works Price (excluding GST) Unit Price for inland transportation and other services required in India to convey the Goods to their final destination Total Price for inland transportation and other services required in India to convey the Goods to their final destination (excluding GST) GST payable on the price quoted if Contract is awarded Total Price per line item #REF!
Transmission Line Package TL02 GST on Ex works GST on F&I Total Ex works (exc GST) Total F&I (exc GST) Rounded off UnitPrice Total Corrected Price (excl. GST) GST rate GST @12% GST @18% GST @28% GST amount @12% GST amount @18% GST amount @28%
TL02 Pkg for 66kV Himya-Mudh Nyoma part2 0 0 0.00 0.00 0 #REF! 0.00 0.00 #REF! 0.00 0.00 0.00 #REF! #REF! #REF! #REF! #REF! #REF! #REF!
1 7000024509 2660 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 316 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
2 7000024509 2670 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 424 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
3 7000024509 2680 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 252 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
4 7000024509 2690 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 230 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
5 7000024509 2700 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
6 7000024509 2710 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
7 7000024509 2720 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
8 7000024509 2730 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
9 7000024509 2740 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
10 7000024509 2750 STUB FAB SUPPLY 1000069045 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
11 7000024509 2760 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
12 7000024509 2770 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
13 7000024509 2780 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 27 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
14 7000024509 2790 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 7 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
15 7000024509 2800 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 27 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
16 7000024509 2810 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 249 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
17 7000024509 2820 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
18 7000024509 2830 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 307 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
19 7000024509 2840 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 307 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
20 7000024509 2850 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 307 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
21 7000024509 2860 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 307 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
22 7000024509 2870 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 307 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
23 7000024509 2880 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 79 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
24 7000024509 2890 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 152 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
25 7000024509 2900 CONDUCTOR & Earthwire 1000030840 18 7/3.15 G.S. EARTHWIRE KM 51 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
26 7000024509 2910 INSULATOR 1000006183 18 90 KN AC Disc Insulator EA 30453 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
27 7000024509 2920 INSULATOR 1000005023 18 70 KN AC Disc Insulator EA 2392 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
28 7000024509 2930 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 1371 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
29 7000024509 10 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 237 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
30 7000024509 2940 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 463 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
31 7000024509 2950 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 80 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
32 7000024509 2960 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 1361 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
33 7000024509 2970 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 28 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
34 7000024509 2980 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 536 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
35 7000024509 2990 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 3221 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
36 7000024509 3000 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 28 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
37 7000024509 3010 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 93 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
38 7000024509 3020 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 15 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
39 7000024509 3030 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 8 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
40 7000024509 3040 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
41 7000024509 3050 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 56 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
42 7000024509 3060 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
43 7000024509 3070 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 23 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
44 7000024509 3080 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
45 7000024509 3090 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 127 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
46 7000024509 3100 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 67 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
47 7000024509 3110 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
48 7000024509 3120 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 24 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
49 7000024509 3130 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
50 7000024509 3140 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 117 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
51 7000024509 3150 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 14 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
52 7000024509 3160 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
53 7000024509 3170 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 46 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
54 7000024509 3180 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 47 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
55 7000024509 3190 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 307 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
56 7000024509 3200 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
57 7000024509 3210 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 109 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
58 7000024509 3220 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 55 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
59 7000024509 3230 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 65 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
60 7000024509 3240 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 76 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
61 7000024509 3250 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 58 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
62 7000024509 3260 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 64 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
63 7000024509 3270 FAB SUPPLY TOWERS 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 107 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
64 7000024509 3280 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 79 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
65 7000024509 140 TOWER STUB EXTENSION 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
66 7000024509 150 TOWER STUB EXTENSION 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
67 7000024509 160 TOWER STUB EXTENSION 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
68 7000024509 170 TOWER STUB EXTENSION 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
69 7000024509 180 TOWER STUB EXTENSION 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
70 7000024509 190 TOWER STUB EXTENSION 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
71 7000024509 200 TOWER STUB EXTENSION 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
72 7000024509 210 TOWER STUB EXTENSION 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
73 7000024509 220 TOWER STUB EXTENSION 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
74 7000024509 230 TOWER STUB EXTENSION 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
75 7000024509 240 TOWER STUB EXTENSION 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 6 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
76 7000024509 250 TOWER STUB EXTENSION 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
77 7000024509 260 TOWER STUB EXTENSION 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
78 7000024509 270 TOWER STUB EXTENSION 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
79 7000024509 280 TOWER STUB EXTENSION 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
80 7000024509 290 TOWER STUB EXTENSION 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
81 7000024509 300 TOWER STUB EXTENSION 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
82 7000024509 310 TOWER STUB EXTENSION 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
83 7000024509 320 TOWER STUB EXTENSION 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
84 7000024509 330 TOWER STUB EXTENSION 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
85 7000024509 340 TOWER STUB EXTENSION 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
86 7000024509 350 TOWER STUB EXTENSION 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
87 7000024509 360 TOWER STUB EXTENSION 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
88 7000024509 370 TOWER STUB EXTENSION 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
TL02 Pkg for 66kV Mudh Nyoma-Koyul 0 0 0.00 0.00
1 7000024509 380 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 476 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
2 7000024509 390 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 632 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
3 7000024509 400 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 380 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
4 7000024509 410 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 346 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
5 7000024509 420 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
6 7000024509 430 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
7 7000024509 440 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
8 7000024509 450 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
9 7000024509 460 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
10 7000024509 470 STUB FAB SUPPLY 1000069045 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
11 7000024509 480 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
12 7000024509 490 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 5 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
13 7000024509 500 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 41 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
14 7000024509 510 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
15 7000024509 520 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 41 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
16 7000024509 530 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 374 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
17 7000024509 540 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 46 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
18 7000024509 550 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 461 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
19 7000024509 560 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 461 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
20 7000024509 570 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 461 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
21 7000024509 580 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 461 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
22 7000024509 590 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 461 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
23 7000024509 600 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 119 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
24 7000024509 610 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 228 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
25 7000024509 620 CONDUCTOR & Earthwire 1000030840 18 7/3.15 G.S. EARTHWIRE KM 77 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
26 7000024509 630 INSULATOR 1000006183 18 90 KN AC Disc Insulator EA 45595 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
27 7000024509 640 INSULATOR 1000005023 18 70 KN AC Disc Insulator EA 3606 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
28 7000024509 650 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 2052 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
29 7000024509 660 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 357 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
30 7000024509 670 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 693 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
31 7000024509 680 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 121 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
32 7000024509 690 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 1627 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
33 7000024509 700 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 43 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
34 7000024509 710 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 803 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
35 7000024509 720 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 4830 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
36 7000024509 730 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 42 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
37 7000024509 740 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 140 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
38 7000024509 750 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 23 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
39 7000024509 760 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 12 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
40 7000024509 770 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 46 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
41 7000024509 780 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 82 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
42 7000024509 790 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
43 7000024509 800 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
44 7000024509 810 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 20 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
45 7000024509 820 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 193 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
46 7000024509 830 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 103 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
47 7000024509 840 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
48 7000024509 850 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 36 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
49 7000024509 860 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 49 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
50 7000024509 870 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 178 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
51 7000024509 880 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
52 7000024509 890 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 19 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
53 7000024509 900 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 66 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
54 7000024509 910 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
55 7000024509 920 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 462 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
56 7000024509 930 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
57 7000024509 940 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 164 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
58 7000024509 950 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 80 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
59 7000024509 960 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 100 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
60 7000024509 970 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 116 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
61 7000024509 980 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 87 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
62 7000024509 990 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 96 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
63 7000024509 1000 FAB SUPPLY TOWERS 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 159 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
64 7000024509 1010 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 119 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
TL02 Pkg for 66kV Mudh Nyoma-Korzok
1 7000024509 1140 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 284 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
2 7000024509 1150 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 378 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
3 7000024509 1160 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 229 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
4 7000024509 1170 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 205 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
5 7000024509 1180 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 4 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
6 7000024509 1190 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
7 7000024509 1200 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
8 7000024509 1210 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
9 7000024509 1220 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
10 7000024509 1230 STUB FAB SUPPLY 1000069045 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
11 7000024509 1240 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
12 7000024509 1250 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
13 7000024509 1260 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
14 7000024509 1270 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 8 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
15 7000024509 1280 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 25 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
16 7000024509 1290 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 224 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
17 7000024509 1300 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 28 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
18 7000024509 1310 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
19 7000024509 1320 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
20 7000024509 1330 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
21 7000024509 1340 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
22 7000024509 1350 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 277 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
23 7000024509 1360 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 71 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
24 7000024509 1370 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 137 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
28 7000024509 1410 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 1236 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
29 7000024509 1420 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 213 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
30 7000024509 1430 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 419 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
31 7000024509 1440 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 72 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
32 7000024509 1450 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 980 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
33 7000024509 1460 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 26 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
34 7000024509 1470 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 483 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
35 7000024509 1480 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 2910 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
36 7000024509 1490 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 26 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
37 7000024509 1500 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 84 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
38 7000024509 1510 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 14 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
39 7000024509 1520 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 7 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
40 7000024509 1530 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 28 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
41 7000024509 1540 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 50 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
42 7000024509 1550 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
43 7000024509 1560 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
44 7000024509 1570 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
45 7000024509 1580 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 116 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
46 7000024509 1590 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
47 7000024509 1600 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
48 7000024509 1610 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
49 7000024509 1620 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
50 7000024509 1630 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 108 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
51 7000024509 1640 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
52 7000024509 1650 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
53 7000024509 1660 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 44 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
54 7000024509 1670 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 45 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
55 7000024509 1680 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 274 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
56 7000024509 1690 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 8 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
57 7000024509 1700 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 100 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
58 7000024509 1710 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 48 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
59 7000024509 1720 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 60 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
60 7000024509 1730 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
61 7000024509 1740 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 52 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
62 7000024509 1750 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 58 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
63 7000024509 1760 FAB SUPPLY TOWERS 1000069047 28 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 96 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 28.00 0.00 0.00 0.00 0 0 0
64 7000024509 1770 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 71 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
TL02 Pkg for 66kV Mudh Nyoma-Hanle
1 7000024509 1900 STUB FAB SUPPLY 1000069035 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.) EA 348 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
2 7000024509 1910 STUB FAB SUPPLY 1000069036 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.) EA 462 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
3 7000024509 1920 STUB FAB SUPPLY 1000069037 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.) EA 278 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
4 7000024509 1930 STUB FAB SUPPLY 1000069050 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS INCLUDING BOLTS & NUTS, PACK WASHER ETC. FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FORHILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.) EA 254 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
5 7000024509 1940 STUB FAB SUPPLY 1000069039 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 4 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
6 7000024509 1950 STUB FAB SUPPLY 1000069040 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
7 7000024509 1960 STUB FAB SUPPLY 1000069041 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 1.5M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
8 7000024509 1970 STUB FAB SUPPLY 1000069043 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DB (UP TO +9M EXTN.) EA 2 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
9 7000024509 1980 STUB FAB SUPPLY 1000069044 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DC (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
10 7000024509 1990 STUB FAB SUPPLY 1000069045 18 FABRICATION, GALVANISING AND SUPPLY OF STUB & CLEATS (PER LEG) FORVARIOUS TYPE OF TOWERS SUITABLE FOR 3.0M RAISED CHIMNEY INCLUDINGBOLTS & NUTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600MFOR 5 MM ICE ; TOWER TYPE DD (UP TO +9M EXTN.) EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
11 7000024509 2000 EARTHING OF TOWERS 1000019718 18 Supply of Shieldwire EarthingincludingPG clamps, downlead clampsbutexcluding Earthwire bits for Pipetypeearthing EA 1 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
12 7000024509 2010 EARTHING OF TOWERS 1000045873 18 PIPE TYPE CHEMICAL EARTHING EA 3 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
13 7000024509 2020 EARTHING OF TOWERS 1000017587 18 Supply of Pipe Type Earthing EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
14 7000024509 2030 EARTHING OF TOWERS 1000057380 18 Supply of Shieldwire Earthing Counterpoise (4X30M) Type including PGclamps, downlead clamps but excluding Earthwire bits. EA 8 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
15 7000024509 2040 EARTHING OF TOWERS 1000048808 18 SUPPLY OF CHEMICAL EARTHING: COUNTERPOISE TYPE (120M LENGTH) EA 30 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
16 7000024509 2050 EARTHING OF TOWERS 1000010003 18 Supply of Counterpoise type (120 mlength) EA 274 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
17 7000024509 2060 EARTHING OF TOWERS 1000038340 18 ROD TYPE EARTHING EA 34 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
18 7000024509 2070 TOWER ACCESSORIES 1000017508 18 Phase Plate (Set of three) SET 338 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
19 7000024509 2080 TOWER ACCESSORIES 1000009119 18 Circuit Plate (Set of two) SET 338 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
20 7000024509 2090 TOWER ACCESSORIES 1000006779 18 Supply of Anti-Climbing Devices ofBarbedWire Type SET 338 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
21 7000024509 2100 TOWER ACCESSORIES 1000032563 18 DANGER PLATE FOR 66 KV EA 338 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
22 7000024509 2110 TOWER ACCESSORIES 1000034828 18 NUMBER PLATE FOR 66 KV TOWER EA 338 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
23 7000024509 2120 TOWER ACCESSORIES 1000007735 18 Bird Guard (Set of Three) SET 87 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
24 7000024509 2130 CONDUCTOR & Earthwire 1000030861 18 ACSR PANTHER CONDUCTOR KM 167 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
25 7000024509 2140 CONDUCTOR & Earthwire 1000030840 18 7/3.15 G.S. EARTHWIRE KM 56 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
26 7000024509 2150 INSULATOR 1000006183 18 90 KN AC Disc Insulator EA 33463 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
27 7000024509 2160 INSULATOR 1000005023 18 70 KN AC Disc Insulator EA 2636 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
28 7000024509 2170 HARDWARE FITTINGS 1000062512 18 HARDWARE FITTINGS FOR 66KV AC WITH ACSR PANTHERCONDUCTOR-DOUBLETENSION STRING SET 1506 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
29 7000024509 2180 HARDWARE FITTINGS 1000069346 18 HARDWARE FITTINGS FOR 66KV WITH SINGLE ACSR PANTHER-SINGLESUSPENSIONSTRING SET 261 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
30 7000024509 2190 CONDUCTOR & Earthwire ACCESSORIES 1000020990 18 Tension clamp -7/3.15mm Earth Wire EA 510 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
31 7000024509 2200 CONDUCTOR & Earthwire ACCESSORIES 1000020446 18 Suspension clamp -7/3.15mm Earth Wire EA 88 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
32 7000024509 2210 CONDUCTOR & Earthwire ACCESSORIES 1000022419 18 Vibration damper -7/3.15mm Earth Wire EA 1194 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
33 7000024509 2220 CONDUCTOR & Earthwire ACCESSORIES 1000015517 18 Mid Span Compression Joint -7/3.15mm Earth Wire EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
34 7000024509 2230 CONDUCTOR & Earthwire ACCESSORIES 1000034136 18 FLEXIBLE ALUMUNIUM BOND EA 589 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
35 7000024509 2240 CONDUCTOR & Earthwire ACCESSORIES 1000022432 18 Vibration Damper for Conductor-ACSR Panther EA 3546 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
36 7000024509 2250 CONDUCTOR & Earthwire ACCESSORIES 1000018444 18 Repair Sleeve for Conductor-ACSR Panther EA 31 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
37 7000024509 2260 CONDUCTOR & Earthwire ACCESSORIES 1000015514 18 Mid Span Compression Joint for Conductor-ACSR Panther EA 103 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
38 7000024509 2270 SUPPLY OF AVIATION 1000016663 18 Supply of Obstruction Lights (as perIS5613)-1 Medium Intensity + 2LowIntensity SET 17 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
39 7000024509 2280 SUPPLY OF AVIATION 1000016664 18 Supply of Obstruction Lights (as per IS5613)-1 Medium Intensity + 4 LowIntensity SET 9 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
40 7000024509 2290 SUPPLY OF AVIATION 1000019903 18 Supply of Span Marker for Aviation EA 34 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
41 7000024509 2300 FAB SUPPLY TOWERS 1000069070 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
42 7000024509 2310 FAB SUPPLY TOWERS 1000069069 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
43 7000024509 2320 FAB SUPPLY TOWERS 1000069068 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 26 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
44 7000024509 2330 FAB SUPPLY TOWERS 1000069067 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 15 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
45 7000024509 2340 FAB SUPPLY TOWERS 1000069066 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 140 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
46 7000024509 2350 FAB SUPPLY TOWERS 1000069065 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 74 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
47 7000024509 2360 FAB SUPPLY TOWERS 1000069064 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
48 7000024509 2370 FAB SUPPLY TOWERS 1000069063 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 26 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
49 7000024509 2380 FAB SUPPLY TOWERS 1000069062 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 39 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
50 7000024509 2390 FAB SUPPLY TOWERS 1000069061 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 128 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
51 7000024509 2400 FAB SUPPLY TOWERS 1000069060 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
52 7000024509 2410 FAB SUPPLY TOWERS 1000069059 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 14 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
53 7000024509 2420 FAB SUPPLY TOWERS 1000069058 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 49 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
54 7000024509 2430 FAB SUPPLY TOWERS 1000069057 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 50 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
55 7000024509 2440 FAB SUPPLY TOWERS 1000069056 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 339 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00
56 7000024509 2450 FAB SUPPLY TOWERS 1000069055 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
57 7000024509 2460 FAB SUPPLY TOWERS 1000069054 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 120 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
58 7000024509 2470 FAB SUPPLY TOWERS 1000069053 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 60 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
59 7000024509 2480 FAB SUPPLY TOWERS 1000069052 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 72 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
60 7000024509 2490 FAB SUPPLY TOWERS 1000069051 18 FABRICATION, GALVANISING AND SUPPLY OF LEG EXTENSIONS INCLUDING BOLTS&NUTS, STEPBOLTS, PACK WASHER ETC. FOR FOR 66KV DC (SINGLE PANTHER ,WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO5600M FOR 5 MM ICE: +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASICTOWER BODY, PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OFONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 84 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
61 7000024509 2500 FAB SUPPLY TOWERS 1000069049 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DD . EA 64 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
62 7000024509 2510 FAB SUPPLY TOWERS 1000069048 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DC . EA 70 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
63 7000024509 2520 FAB SUPPLY TOWERS 1000069047 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DB . EA 117 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
64 7000024509 2530 FAB SUPPLY TOWERS 1000069046 18 FABRICATION, GALVANISING AND SUPPLY OF BASIC TOWER BODY INCLUDINGÂCOMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS,D-SHACKLES, PACK WASHER ETC. AND EXCLUDING STUB FOR 66KV DC (SINGLEPANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREAALTITUDE UP TO 5600M FOR 5 MM ICE; TOWER TYPE DA . EA 87 INCLUDED INCLUDED 0.00 INCLUDED 0 0 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0.00 18.00 0.00 0.00 0.00 0 0 0
Total Ex-Works Price 0.00 0.00 0.00 0.00 0.00 #REF! #REF! #REF! #REF!
Total Price for inland transportation and other services required in India to convey the Goods to their final destination (excluding GST) 0.00
GST payable on the price quoted if Contract is awarded 0.00 #REF! #REF! #REF! #REF!
Total Ex-Works Price including GST 0.00
Date Printed Name
Place Designation
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Schedule - 2
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Supply of Installation Services :
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable (in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit price GST payable on the price quoted if Contract is awarded (%) Total Price per line item (excluding GST) GST payable on the price quoted if Contract is awarded (Amount) Total Price per line item (including GST) GST Before Discount Discount Total Price after discount GST After Discount
Transmission Line Package TL02 Rounded off UnitPrice Total Corrected Price (excl. GST) GST rate GST Amount
TL02 Pkg for 66kV Himya-Mudh Nyoma part2
1 7000024509 20 100 10 SURVEY 100001243 Check survey KM 50 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024509 20 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 50 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024509 30 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024509 30 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024509 30 110 30 SOIL INVESTIGATION 100001246 Detailed soil investigation: Hard Rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024509 40 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 6 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024509 40 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044199 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024509 40 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100044227 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024509 40 120 90 WORK ASSOCIATED WITH TOWER FOUNDATION 100044224 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024509 40 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044221 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024509 40 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024509 40 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024509 40 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024509 40 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024509 40 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024509 40 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 23 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024509 40 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024509 40 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 17 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024509 40 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 6 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024509 40 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044204 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024509 40 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024509 40 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024509 40 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 316 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024509 40 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 424 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024509 40 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 252 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024509 40 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 230 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024509 40 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024509 40 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024509 40 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024509 40 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024509 40 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024509 40 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044261 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024509 40 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024509 40 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 23 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024509 40 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044181 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024509 40 120 470 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024509 40 120 480 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024509 40 120 490 WORK ASSOCIATED WITH TOWER FOUNDATION 100044184 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024509 40 120 500 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 17 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024509 40 120 510 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024509 40 120 520 WORK ASSOCIATED WITH TOWER FOUNDATION 100044187 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024509 40 120 530 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 17 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024509 40 120 540 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024509 40 120 570 WORK ASSOCIATED WITH TOWER FOUNDATION 100044192 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024509 40 120 580 WORK ASSOCIATED WITH TOWER FOUNDATION 100044193 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024509 40 120 590 WORK ASSOCIATED WITH TOWER FOUNDATION 100044194 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024509 40 120 600 WORK ASSOCIATED WITH TOWER FOUNDATION 100044195 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024509 40 120 610 WORK ASSOCIATED WITH TOWER FOUNDATION 100044196 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024509 40 120 640 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 6 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024509 40 120 660 WORK ASSOCIATED WITH TOWER FOUNDATION 100044177 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024509 40 120 670 WORK ASSOCIATED WITH TOWER FOUNDATION 100044176 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024509 40 120 680 WORK ASSOCIATED WITH TOWER FOUNDATION 100044175 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024509 40 120 690 WORK ASSOCIATED WITH TOWER FOUNDATION 100044174 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024509 40 120 700 WORK ASSOCIATED WITH TOWER FOUNDATION 100044173 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024509 40 120 710 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024509 40 120 740 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 36 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024509 40 120 750 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 143 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024509 40 120 760 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024509 40 120 770 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 51 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024509 40 120 780 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 145 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024509 40 120 790 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024509 40 120 800 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 76 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024509 40 120 810 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 251 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024509 40 120 820 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024509 40 120 830 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 183 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024509 40 120 840 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 69 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024509 50 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024509 50 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024509 50 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 117 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024509 50 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024509 50 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 24 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024509 50 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024509 50 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 67 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024509 50 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 127 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024509 50 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024509 50 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 23 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024509 50 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024509 50 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 56 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024509 50 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 46 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024509 50 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 47 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024509 50 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 307 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024509 50 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024509 50 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 109 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024509 50 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 55 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024509 50 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 65 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024509 50 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 76 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024509 50 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 58 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024509 50 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 64 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024509 50 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 107 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024509 50 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 79 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024509 60 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024509 60 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024509 60 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024509 60 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 27 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024509 60 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 31 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024509 60 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 249 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024509 60 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 27 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024509 70 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 307 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024509 70 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 307 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
100 7000024509 70 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 307 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
101 7000024509 70 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 307 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
102 7000024509 70 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 307 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
103 7000024509 70 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 79 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
104 7000024509 80 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 50 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
105 7000024509 90 190 10 PAINTING 100001285 Painting of towers MT 310 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
106 7000024509 100 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 31 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
107 7000024509 100 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
108 7000024509 100 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
109 7000024509 110 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 6058 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
110 7000024509 110 210 20 BENCHING 100001253 Benching: Fissured Rock M3 1656 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
111 7000024509 110 210 30 BENCHING 100001254 Benching:Hard Rock M3 413 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
112 7000024509 120 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 7684 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
113 7000024509 120 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 77 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
114 7000024509 120 220 40 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 768 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
115 7000024509 130 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
TL02 Pkg for 66kV Mudh Nyoma-Koyul
1 7000024509 1020 100 10 SURVEY 100001243 Check survey KM 75 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024509 1020 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 75 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024509 1030 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024509 1030 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024509 1030 110 30 SOIL INVESTIGATION 100001246 Detailed soil investigation: Hard Rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024509 1040 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024509 1040 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044199 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024509 1040 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100044221 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024509 1040 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024509 1040 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024509 1040 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024509 1040 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024509 1040 120 80 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024509 1040 120 90 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 36 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024509 1040 120 100 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024509 1040 120 110 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024509 1040 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044201 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024509 1040 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024509 1040 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044204 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024509 1040 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024509 1040 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044207 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024509 1040 120 170 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024509 1040 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 476 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024509 1040 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 632 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024509 1040 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 380 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024509 1040 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 346 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024509 1040 120 220 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024509 1040 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024509 1040 120 240 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024509 1040 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044258 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 0.01 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024509 1040 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024509 1040 120 270 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024509 1040 120 280 WORK ASSOCIATED WITH TOWER FOUNDATION 100044261 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024509 1040 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024509 1040 120 300 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024509 1040 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044181 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024509 1040 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 48 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024509 1040 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024509 1040 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044184 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024509 1040 120 350 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024509 1040 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024509 1040 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044187 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024509 1040 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024509 1040 120 390 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024509 1040 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044192 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024509 1040 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044194 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024509 1040 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044195 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024509 1040 120 430 WORK ASSOCIATED WITH TOWER FOUNDATION 100044196 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024509 1040 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024509 1040 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044177 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024509 1040 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044175 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024509 1040 120 470 WORK ASSOCIATED WITH TOWER FOUNDATION 100044174 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024509 1040 120 480 WORK ASSOCIATED WITH TOWER FOUNDATION 100044173 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024509 1040 120 490 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024509 1040 120 500 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 52 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024509 1040 120 510 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 216 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024509 1040 120 520 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024509 1040 120 530 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 76 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024509 1040 120 540 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 220 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024509 1040 120 550 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024509 1040 120 560 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 108 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024509 1040 120 570 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 376 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024509 1040 120 580 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 22 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024509 1040 120 590 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 276 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024509 1040 120 600 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 104 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024509 1050 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 19 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024509 1050 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 21 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024509 1050 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 178 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024509 1050 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 49 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024509 1050 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 36 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024509 1050 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024509 1050 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 103 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024509 1050 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 193 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024509 1050 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024509 1050 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 35 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024509 1050 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 18 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024509 1050 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 82 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024509 1050 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 66 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024509 1050 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024509 1050 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 462 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024509 1050 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024509 1050 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 164 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024509 1050 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 80 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024509 1050 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 100 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024509 1050 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 116 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024509 1050 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 87 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024509 1050 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 96 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024509 1050 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 159 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024509 1050 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 119 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024509 1060 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024509 1060 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 5 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024509 1060 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024509 1060 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 41 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024509 1060 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 46 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024509 1060 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 374 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024509 1060 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 41 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024509 1070 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 461 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024509 1070 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 461 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024509 1070 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 461 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
100 7000024509 1070 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 461 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
101 7000024509 1070 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 461 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
102 7000024509 1070 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 119 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
103 7000024509 1080 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 75 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
104 7000024509 1090 190 10 PAINTING 100001285 Painting of towers MT 460 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
105 7000024509 1100 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 46 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
106 7000024509 1100 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 23 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
107 7000024509 1100 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
108 7000024509 1110 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 9087 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
109 7000024509 1110 210 20 BENCHING 100001253 Benching: Fissured Rock M3 2483 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
110 7000024509 1110 210 30 BENCHING 100001254 Benching:Hard Rock M3 620 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
111 7000024509 1120 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 11525 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
112 7000024509 1120 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 115 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
113 7000024509 1120 220 30 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 1153 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
114 7000024509 1130 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
TL02 Pkg for 66kV Mudh Nyoma-Korzok 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
1 7000024509 1780 100 10 SURVEY 100001243 Check survey KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024509 1780 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024509 1790 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024509 1790 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024509 1790 110 30 SOIL INVESTIGATION 100001246 Detailed soil investigation: Hard Rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024509 1800 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024509 1800 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044227 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024509 1800 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100044224 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024509 1800 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024509 1800 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024509 1800 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024509 1800 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024509 1800 120 80 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024509 1800 120 90 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024509 1800 120 100 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024509 1800 120 110 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024509 1800 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044201 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024509 1800 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024509 1800 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044204 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024509 1800 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024509 1800 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024509 1800 120 170 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 284 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024509 1800 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 378 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024509 1800 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 229 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024509 1800 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 205 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024509 1800 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024509 1800 120 220 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024509 1800 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024509 1800 120 240 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024509 1800 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024509 1800 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044261 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024509 1800 120 270 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024509 1800 120 280 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024509 1800 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024509 1800 120 300 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024509 1800 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044184 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024509 1800 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024509 1800 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024509 1800 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044187 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024509 1800 120 350 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024509 1800 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024509 1800 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044192 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024509 1800 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044193 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024509 1800 120 390 WORK ASSOCIATED WITH TOWER FOUNDATION 100044196 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024509 1800 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024509 1800 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044177 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024509 1800 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044176 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024509 1800 120 430 WORK ASSOCIATED WITH TOWER FOUNDATION 100044175 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024509 1800 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044174 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024509 1800 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044173 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024509 1800 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024509 1800 120 470 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 32 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024509 1800 120 480 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 128 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024509 1800 120 490 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024509 1800 120 500 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024509 1800 120 510 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 132 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024509 1800 120 520 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024509 1800 120 530 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 72 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024509 1800 120 540 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 224 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024509 1800 120 550 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024509 1800 120 560 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 168 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024509 1800 120 570 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 68 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024509 1810 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 10 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024509 1810 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024509 1810 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 108 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024509 1810 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 31 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024509 1810 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024509 1810 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024509 1810 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024509 1810 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 116 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024509 1810 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 11 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024509 1810 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 22 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024509 1810 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024509 1810 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 50 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024509 1810 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024509 1810 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024509 1810 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 274 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024509 1810 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024509 1810 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 100 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024509 1810 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 48 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024509 1810 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 60 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024509 1810 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 68 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024509 1810 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 52 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024509 1810 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 58 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024509 1810 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 96 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024509 1810 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 71 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024509 1820 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024509 1820 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024509 1820 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024509 1820 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 25 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024509 1820 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024509 1820 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 224 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024509 1820 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 25 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024509 1830 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024509 1830 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024509 1830 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024509 1830 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024509 1830 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 277 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024509 1830 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 71 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
100 7000024509 1840 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 45 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
101 7000024509 1850 190 10 PAINTING 100001285 Painting of towers MT 280 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
102 7000024509 1860 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
103 7000024509 1860 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
104 7000024509 1860 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 7 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
105 7000024509 1870 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 5460 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
106 7000024509 1870 210 20 BENCHING 100001253 Benching: Fissured Rock M3 1492 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
107 7000024509 1870 210 30 BENCHING 100001254 Benching:Hard Rock M3 372 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
108 7000024509 1880 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 6925 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
109 7000024509 1880 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 69 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
110 7000024509 1880 220 30 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 693 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
111 7000024509 1890 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
TL02 Pkg for 66kV Mudh Nyoma-Hanle
1 7000024509 2540 100 10 SURVEY 100001243 Check survey KM 55 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
2 7000024509 2540 100 20 SURVEY 100001242 Detailed survey including route alignment, profiling and tower spotting KM 55 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
3 7000024509 2550 110 10 SOIL INVESTIGATION 100001244 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
4 7000024509 2550 110 20 SOIL INVESTIGATION 100001245 Detailed soil investigation: Fissured Rock EA 10 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
5 7000024509 2550 110 30 SOIL INVESTIGATION 100001246 Detailed soil investigation: Hard Rock EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
6 7000024509 2560 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100044200 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
7 7000024509 2560 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100044220 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
8 7000024509 2560 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100044219 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
9 7000024509 2560 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100044218 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
10 7000024509 2560 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100044217 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
11 7000024509 2560 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100044215 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
12 7000024509 2560 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100044214 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
13 7000024509 2560 120 80 WORK ASSOCIATED WITH TOWER FOUNDATION 100044213 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
14 7000024509 2560 120 90 WORK ASSOCIATED WITH TOWER FOUNDATION 100044212 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
15 7000024509 2560 120 100 WORK ASSOCIATED WITH TOWER FOUNDATION 100044202 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
16 7000024509 2560 120 110 WORK ASSOCIATED WITH TOWER FOUNDATION 100044204 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
17 7000024509 2560 120 120 WORK ASSOCIATED WITH TOWER FOUNDATION 100044205 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
18 7000024509 2560 120 130 WORK ASSOCIATED WITH TOWER FOUNDATION 100044208 DESIGN & INSTALLATION OF HR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
19 7000024509 2560 120 140 WORK ASSOCIATED WITH TOWER FOUNDATION 100044262 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DA (UP TO+9M EXTN.). EA 348 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
20 7000024509 2560 120 150 WORK ASSOCIATED WITH TOWER FOUNDATION 100044263 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 462 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
21 7000024509 2560 120 160 WORK ASSOCIATED WITH TOWER FOUNDATION 100044264 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 278 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
22 7000024509 2560 120 170 WORK ASSOCIATED WITH TOWER FOUNDATION 100044265 INSTALLATION OF STUB (PER LEG) INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 254 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
23 7000024509 2560 120 180 WORK ASSOCIATED WITH TOWER FOUNDATION 100044255 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
24 7000024509 2560 120 190 WORK ASSOCIATED WITH TOWER FOUNDATION 100044256 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
25 7000024509 2560 120 200 WORK ASSOCIATED WITH TOWER FOUNDATION 100044257 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 1.5 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
26 7000024509 2560 120 210 WORK ASSOCIATED WITH TOWER FOUNDATION 100044259 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DB (UP TO+9M EXTN.). EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
27 7000024509 2560 120 220 WORK ASSOCIATED WITH TOWER FOUNDATION 100044260 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3 M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DC (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
28 7000024509 2560 120 230 WORK ASSOCIATED WITH TOWER FOUNDATION 100044261 INSTALLATION OF STUB (PER LEG) SUITABLE FOR 3M RAISED CHIMNEY INCLUDING CLEATS, BOLTS AND NUTS FOR 66KV DC (SINGLE PANTHER , WZ6)TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE ; TOWER TYPE DD (UP TO+9M EXTN.). EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
29 7000024509 2560 120 240 WORK ASSOCIATED WITH TOWER FOUNDATION 100044179 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
30 7000024509 2560 120 250 WORK ASSOCIATED WITH TOWER FOUNDATION 100044180 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 28 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
31 7000024509 2560 120 260 WORK ASSOCIATED WITH TOWER FOUNDATION 100044181 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
32 7000024509 2560 120 270 WORK ASSOCIATED WITH TOWER FOUNDATION 100044182 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 36 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
33 7000024509 2560 120 280 WORK ASSOCIATED WITH TOWER FOUNDATION 100044183 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
34 7000024509 2560 120 290 WORK ASSOCIATED WITH TOWER FOUNDATION 100044184 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
35 7000024509 2560 120 300 WORK ASSOCIATED WITH TOWER FOUNDATION 100044185 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
36 7000024509 2560 120 310 WORK ASSOCIATED WITH TOWER FOUNDATION 100044186 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
37 7000024509 2560 120 320 WORK ASSOCIATED WITH TOWER FOUNDATION 100044188 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 20 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
38 7000024509 2560 120 330 WORK ASSOCIATED WITH TOWER FOUNDATION 100044189 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 4 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
39 7000024509 2560 120 340 WORK ASSOCIATED WITH TOWER FOUNDATION 100044192 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
40 7000024509 2560 120 350 WORK ASSOCIATED WITH TOWER FOUNDATION 100044196 DESIGN & INSTALLATION OF DRY FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
41 7000024509 2560 120 360 WORK ASSOCIATED WITH TOWER FOUNDATION 100044211 DESIGN & INSTALLATION OF WFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
42 7000024509 2560 120 370 WORK ASSOCIATED WITH TOWER FOUNDATION 100044177 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
43 7000024509 2560 120 380 WORK ASSOCIATED WITH TOWER FOUNDATION 100044175 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
44 7000024509 2560 120 390 WORK ASSOCIATED WITH TOWER FOUNDATION 100044174 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
45 7000024509 2560 120 400 WORK ASSOCIATED WITH TOWER FOUNDATION 100044173 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;3 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 2 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
46 7000024509 2560 120 410 WORK ASSOCIATED WITH TOWER FOUNDATION 100044172 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;1.5 M RAISED CHIMNEY FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
47 7000024509 2560 120 420 WORK ASSOCIATED WITH TOWER FOUNDATION 100044169 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( +1.5 TO +9 M LEG EXTN ) EA 44 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
48 7000024509 2560 120 430 WORK ASSOCIATED WITH TOWER FOUNDATION 100044168 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +0 M LEG EXTN ) EA 156 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
49 7000024509 2560 120 440 WORK ASSOCIATED WITH TOWER FOUNDATION 100044167 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DD ( -3 TO +9 M LEG EXTN ) EA 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
50 7000024509 2560 120 450 WORK ASSOCIATED WITH TOWER FOUNDATION 100044166 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( +1.5 TO +9 M LEG EXTN ) EA 60 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
51 7000024509 2560 120 460 WORK ASSOCIATED WITH TOWER FOUNDATION 100044165 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +0 M LEG EXTN ) EA 160 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
52 7000024509 2560 120 470 WORK ASSOCIATED WITH TOWER FOUNDATION 100044164 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DC ( -3 TO +9 M LEG EXTN ) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
53 7000024509 2560 120 480 WORK ASSOCIATED WITH TOWER FOUNDATION 100044163 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( +1.5 TO +9 M LEG EXTN ) EA 80 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
54 7000024509 2560 120 490 WORK ASSOCIATED WITH TOWER FOUNDATION 100044162 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +0 M LEG EXTN ) EA 272 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
55 7000024509 2560 120 500 WORK ASSOCIATED WITH TOWER FOUNDATION 100044161 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH UNEQUALLEGS AS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DB ( -3 TO +9 M LEG EXTN ) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
56 7000024509 2560 120 510 WORK ASSOCIATED WITH TOWER FOUNDATION 100044160 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( +1.5 TO +9 M LEG EXTN ) EA 204 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
57 7000024509 2560 120 520 WORK ASSOCIATED WITH TOWER FOUNDATION 100044159 DESIGN & INSTALLATION OF DFR FOUNDATION (PER LEG) INCLUDING ALL ASSOCIATED WORKS AS SPECIFIED IN TS UPTO 3.5 M FOUNDATION DEPTH FOR66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE WITH EQUAL LEGSAS PER IS 802-2015 FOR HILLY TERRAIN ;FOR TOWER TYPE DA ( -3 TO +0 M LEG EXTN ) EA 76 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
58 7000024509 2570 130 10 ERECTION 100044242 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 14 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
59 7000024509 2570 130 20 ERECTION 100044243 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 16 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
60 7000024509 2570 130 30 ERECTION 100044244 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 128 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
61 7000024509 2570 130 40 ERECTION 100044245 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 39 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
62 7000024509 2570 130 50 ERECTION 100044246 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 26 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
63 7000024509 2570 130 60 ERECTION 100044247 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
64 7000024509 2570 130 70 ERECTION 100044248 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DC ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 74 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
65 7000024509 2570 130 80 ERECTION 100044249 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 140 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
66 7000024509 2570 130 90 ERECTION 100044250 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 15 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
67 7000024509 2570 130 100 ERECTION 100044251 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 26 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
68 7000024509 2570 130 110 ERECTION 100044252 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 13 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
69 7000024509 2570 130 120 ERECTION 100044253 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DD ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 62 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
70 7000024509 2570 130 130 ERECTION 100044241 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 49 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
71 7000024509 2570 130 140 ERECTION 100044240 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 50 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
72 7000024509 2570 130 150 ERECTION 100044239 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DB ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 339 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
73 7000024509 2570 130 160 ERECTION 100044238 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; -3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 12 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
74 7000024509 2570 130 170 ERECTION 100044237 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +9 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 120 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
75 7000024509 2570 130 180 ERECTION 100044236 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +6 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 60 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
76 7000024509 2570 130 190 ERECTION 100044235 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +3 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 72 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
77 7000024509 2570 130 200 ERECTION 100044234 ERECTION OF LEG EXTENSIONS INCLUDING BOLTS & NUTS, STEPBOLTS, PACK WASHER ETC. FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED ASPER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5 MM ICE; +0 M LEG EXTN FOR TOWER TYPE DA ( EXCLUDING BASIC TOWER BODY,PLAN AT BASIC LEVEL AND STUB BUT INCLUDING ALL PARTS OF ONE QUADRANT OF TOWER BEYOND BASIC TOWER) EA 84 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
78 7000024509 2570 130 210 ERECTION 100044233 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DD (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DD . EA 64 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
79 7000024509 2570 130 220 ERECTION 100044232 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DC . EA 70 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
80 7000024509 2570 130 230 ERECTION 100044231 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DB . EA 117 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
81 7000024509 2570 130 240 ERECTION 100044230 ERECTION OF BASIC TOWER BODY INCLUDINGÂ COMMON PLAN AT BASIC LEVEL, BOLTS & NUTS, STEPBOLTS, HANGERS, D-SHACKLES, PACK WASHER ETC.AND EXCLUDING STUB FOR 66KV DC (SINGLE PANTHER , WZ6) TOWERS DESIGNED AS PER IS 802-2015 FOR HILLY AREA ALTITUDE UP TO 5600M FOR 5MM ICE; TOWER TYPE DA . EA 87 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
82 7000024509 2580 150 10 INSTALLATION OF EARTHING OF TOWERS 100002202 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/ counterpoisetype)-Pipe type EA 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
83 7000024509 2580 150 20 INSTALLATION OF EARTHING OF TOWERS 170002471 Installation of Chemical earthing of towers: Pipe Type . EA 3 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
84 7000024509 2580 150 30 INSTALLATION OF EARTHING OF TOWERS 100018257 Installation of Shieldwire Earthing Counterpoise (4X30M) type including PG clamps, Downlead clamps and Earthwire bits. Shieldwireearthing (Pipe Type/counterpoise type) shall be an in addition to Tower Earthing (Pipe type/counterpoise type) EA 8 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
85 7000024509 2580 150 40 INSTALLATION OF EARTHING OF TOWERS 100008105 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 30 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
86 7000024509 2580 150 50 INSTALLATION OF EARTHING OF TOWERS 100004928 ROD TYPE EARTHING EA 34 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
87 7000024509 2580 150 60 INSTALLATION OF EARTHING OF TOWERS 100001270 Installation of earthing of towers: Counterpoise type (120 m length) EA 274 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
88 7000024509 2580 150 70 INSTALLATION OF EARTHING OF TOWERS 100001269 Installation of earthing of towers: Pipe Type EA 31 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
89 7000024509 2590 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 Installation of tower accessories : Danger Plate EA 338 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
90 7000024509 2590 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 Installation of tower accessories: Number Plate EA 338 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
91 7000024509 2590 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 Installation of tower accessories: Phase Plate (Set of three) SET 338 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
92 7000024509 2590 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 Installation of tower accessories: Circuit Plate (Set of two) SET 338 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
93 7000024509 2590 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 Installation of tower accessories: Anti-Climbing Devices EA 338 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
94 7000024509 2590 160 60 INSTALLATION OF TOWER ACCESSORIES 100001279 Installation of tower accessories: Bird Guard (Set of Three) SET 87 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
95 7000024509 2600 180 10 STRINGING 100044268 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing ofconductorincludingfixing of conductor accessories, installing and stringing of earthwire/OPGW including fixing of earthwire/OPGWaccessories for 66 kV double circuit towers (one ckt out of two ckts) with single PANTHER conductor. KM 55 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
96 7000024509 2610 190 10 PAINTING 100001285 Painting of towers MT 340 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
97 7000024509 2620 200 10 AVIATION 100001282 Installation of Span Markers for aviation requirements EA 34 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
98 7000024509 2620 200 20 AVIATION 100001283 Installation of Obstruction Lights for Aviation requirements 1 Medium Intensity Plus 2 Low Intensity SET 17 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
99 7000024509 2620 200 30 AVIATION 100001284 Installation of Obstruction Lights for Aviation requirements: 1 Medium Intensity + 4 Low Intensity SET 9 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
100 7000024509 2630 210 10 BENCHING 100001252 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 6662 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
101 7000024509 2630 210 20 BENCHING 100001253 Benching: Fissured Rock M3 1821 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
102 7000024509 2630 210 30 BENCHING 100001254 Benching:Hard Rock M3 454 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
103 7000024509 2640 220 10 PROTECTION OF TOWER FOOTING 100001264 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 8450 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
104 7000024509 2640 220 20 PROTECTION OF TOWER FOOTING 100001267 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 85 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
105 7000024509 2640 220 30 PROTECTION OF TOWER FOOTING 100001265 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 845 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
106 7000024509 2650 330 10 CAMP 100023085 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 18 INCLUDED INCLUDED INCLUDED 0 0 0.0000000000 0 0 0.00 0.00 0.00 0 0.00
Total Total Installation / Erection Charges (excluding GST) 0.00
Total GST payable on the price quoted if Contract is awarded (Amount) 0.00
Total Total Installation / Erection Charges (including GST) 0.00 0.00 0.00 0.00 0.00 0.00
Total Corrected Price (excl. GST) GST Amount
Date Printed Name
Place Designation
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Schedule - 5
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST on Goods 0.00 Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00 Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Schedule - 5
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Schedule - 3
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Total Ex-Works Price + price for inland transportation and other services required in India to convey the Goods to their final destination (including GST)
2 TOTAL SCHEDULE NO. 2 0.00
Total Installation / Erection Charges (including GST)
GRAND TOTAL [1+2]
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Schedule - 6 After Discount
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3
Installation Charges
4 TOTAL SCHEDULE NO. 4
Training Charges
5 TOTAL SCHEDULE NO. 5
Taxes and Duties
6 TOTAL SCHEDULE NO. 7
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5]
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Schedule - 6
Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : POWERGRID CORPORATION OF INDIA LIMITED,
Name : Saudamini, Plot No. 2, Sector - 29, Gurgaon
Sl. No. Description Total Price (INR) From Sch-6 Discount Factors
1 TOTAL SCHEDULE NO. 1 0.00 0.00 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 #REF! 0.00 #REF!
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 #REF! #REF! 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
NIT/RFB No.: CC/NT/W-TW/DOM/A06/23/07696 Letter of Discount
LETTER OF DISCOUNT
Contract Services Schedule 1 0.00
Power Grid Corporation of India Ltd., Schedule 2 #REF!
"Saudamini", Plot No.-2 Schedule 3 0.00
Sector-29, (near IFFCO Chowk) Total #REF!
Gurgaon (Haryana) - 122001
Subject : Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch-1 Sch-2 Sch-3
1 Discount on lum-sum basis on total price quoted by us without GST. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4 & Sch-7] In Rs. 0.00 #REF! 0.00
2 Discount on percent basis on total price quoted by us without GST. [The discount shall be applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%) 0.00 #REF! 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Rs. 0.00
Schedule-3 : Installation Charges In Rs. 0.00
Schedule-4 : Training Charges In Rs.
Schedule-7 : Type Test Charges In Rs.
4 Discount on percent basis on the Schedules as given below : [The discount shall be applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Percent (%) #REF!
Schedule-3 : Installation Charges In Percent (%) 0.00
Schedule-4 : Training Charges In Percent (%)
Schedule-7 : Type Test Charges In Percent (%)
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation. #DIV/0! #REF! #DIV/0! #DIV/0! #REF!
[Discount will not be calculated authometrically. However, the same shall be considered during evaluation.]
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain, 0.00 #REF! 0.00
Yours faithfully, 0.00000000 #REF! 0.00000000 Discount Factors
For and on behalf of
Date : #REF! Printed Name : 0.00
Place : #REF! Designation : 0.00
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
STATEMENT OF QUOTED / CORRECTED PRICES
ALL FIGURES ARE IN INDIAN RUPEES
SL. PRICE COMPONENT QUOTED PRICE CORRECTED PRICE
1 Price of Plant and Equipment (including Mandatory Spares Parts) to be supplied [Schedule-1] 0.00 #REF!
2 Local Transportation, In-transit Insurance, loading and unloading charges [Schedule-2] #REF! #REF!
3 Installation Charges [Schedule-3] 0.00 0
4 Type Test Charges [Schedule-7] Not Applicable Not Applicable
5 Total Bid Price excluding GST (1+2+3+4) #REF! #REF!
6 Discount NIL NIL
7 Total Bid Price excluding GST (1+2+3+4) #REF! #REF!
8 Taxes & Duties:
GST on Supply of Goods @5% 0.00 0 total GST on supply 291545315.52
GST on Supply of Goods @12% 0.00 0
GST on Supply of Goods @12% 0.00 #REF!
GST on Supply of Goods @18% #REF!
GST on Supply of Goods @28% #REF!
GST on Supply of Installation Services @ 18% 0.00 0
GST on Type Test Charges Not Applicable Not Applicable
9 Total Taxes & Duties 0.00 #REF!
10 Total Bid Price (including Taxes & Duties) #REF! #REF!
Note-1: It may be mentioned that KEC in Schedule-1 & 3 of their bid, have confirmed/deemed confirmed HSN/SAC code. Also, KEC have confirmed/ deemed confirmed rate of GST for all the items/services in Schedule-1 & 3. Hence the GST tax rate as quoted by KEC has been considered to arrive at their total evaluated bid price, in line with the provisions of the Bidding Documents.
Note-2: It may be mentioned that KEC in Schedule-3 of their bid, have quoted unit prices in more than 2 place of decimals. Accordingly, to work out the total corrected price, unit rates quoted by KEC are rounded off to 2 place of decimals.
Transmission line Tower Package TW03 for 765 kV D/C Navasari (New) (South Gujarat) - Padghe line (Gujarat portion) associated with Transmission Network Expansion in Gujarat to increase its ATC from ISTS: Part B; Spec. No.: 5002002154/TOWER/DOM/A04-CC CS -5
Total Ex-Works Price Direct 0.00
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
^ If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under “Direct transaction” by the bidder, then the taxes and duties on such items shall be paid/reimbursed by POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the rates prevailing on date of Bid opening.
Place : Printed Name : --
Total F&I Price (=SUM(I16:I27))
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Total Installaiton Charges #REF!
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Date : (=IF('Sch-1'!B43=0,"", 'Sch-1'!B43)) (="Printed Name : " & IF('Sch-1'!E44=0,"",'Sch-1'!E44))
Place : (=IF('Sch-1'!B44=0,"", 'Sch-1'!B44)) (="Designation : " & IF('Sch-1'!E45=0,"",'Sch-1'!E45))
TOTAL TYPE TEST CHARGES (=SUM(I17:I18))
Date : (='Sch-1'!B43) (="Printed Name : " & 'Sch-1'!E44)
Place : (='Sch-1'!B44) (="Designation : " & 'Sch-1'!E45)
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
#REF! 0.00 #REF! #REF! #REF!
#REF! #REF! #REF! #N/A
#REF! #REF! 0 #REF! #REF! #REF! #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 0 0 #REF! plus
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 0 1 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 1 0 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 1 1 #REF!
#REF! 0 1 0 0 #REF!
1 One 1 One 1 One 1 One #REF! 0 1 0 1 #REF!
2 Two 2 Two 2 Two 2 Two #REF! 0 1 1 0 #REF!
3 Three 3 Three 3 Three 3 Three #REF! 0 1 1 1 #REF!
4 Four 4 Four 4 Four 4 Four #REF! 1 0 0 0 #REF!
5 Five 5 Five 5 Five 5 Five #REF! 1 0 0 1 #REF!
6 Six 6 Six 6 Six 6 Six #REF! 1 0 1 0 #REF!
7 Seven 7 Seven 7 Seven 7 Seven #REF! 1 0 1 1 #REF!
8 Eight 8 Eight 8 Eight 8 Eight #REF! 1 1 0 0 #REF!
9 Nine 9 Nine 9 Nine 9 Nine #REF! 1 1 0 1 #REF!
10 Ten 10 Ten 10 Ten 10 Ten #REF! 1 1 1 0 #REF!
11 Eleven 11 Eleven 11 Eleven 11 Eleven #REF! 1 1 1 1 #REF!
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen #REF! 0 0 0 0 #REF! +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen #REF! 0 0 0 1 #REF! /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen #REF! 0 0 1 0 #REF! /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen #REF! 0 0 1 1 #REF!
20 Twenty 20 Twenty 20 Twenty 20 Twenty #REF! 0 1 0 0 #REF!
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One #REF! 0 1 0 1 #REF!
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two #REF! 0 1 1 0 #REF!
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three #REF! 0 1 1 1 #REF!
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four #REF! 1 0 0 0 #REF!
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five #REF! 1 0 0 1 #REF!
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six #REF! 1 0 1 0 #REF!
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven #REF! 1 0 1 1 #REF!
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight #REF! 1 1 0 0 #REF!
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine #REF! 1 1 0 1 #REF!
30 Thirty 30 Thirty 30 Thirty 30 Thirty #REF! 1 1 1 0 #REF!
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One #REF! 1 1 1 1 #REF!
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Letter of Bid – Technical Part
Date of this Bid submission: [insert date (as day, month and year) of Bid submission]
NIT/RFB No.: [insert number of Bidding process] CC/NT/W-TW/DOM/A06/23/07696
Title of Procurement/ Contract: [Insert here the title] Transmission line package TL02 for implementation of Distribution Infrastructure works of LPDD under Revamped Distribution Section Scheme (RDSS) in the districts of Leh & Kargil of UT of Ladakh
To: POWER GRID CORPORATION OF INDIA LIMITED, GURUGRAM
1.0 We, the undersigned Bidder, hereby submit our Bid, in two parts, namely:
(a) the Technical Part, and
(b) the Financial Part.
2.0 In submitting our Bid we make the following declarations:
(a) No reservations: We have examined and have no reservations to the bidding document (ITB5), including addenda issued in accordance with Instructions to Bidders (ITB 7);
(b) Eligibility: We meet the eligibility requirements and have no conflict of interest in accordance with ITB 3 and Section 3;
(c) Bid/Proposal-Securing Declaration: We have not been suspended nor declared ineligible by the Purchaser based on execution of a Bid Securing Declaration by the Purchaser in accordance with ITB 10.2.2;
(d) Conformity: We offer to supply in conformity with the bidding document and in accordance with the Delivery Schedules specified in the Schedule of Requirements the all the Goods and Related Services as per the scope mentioned in Part 2, Section 6.;
(e) Bid Validity Period: Our Bid shall be valid for the period specified in BDS 17.1 (as amended if applicable) from the date fixed for the deadline for submission of Bids (specified in BDS 21.1 (as amended if applicable), and it shall remain binding upon us and may be accepted at any time before the expiration of that period;
(f) Performance Security: If our Bid is accepted, we commit to obtain a performance security in accordance with the bidding document;
(g) One Bid per Bidder: We are not submitting any other Bid(s) as an individual Bidder, and meet the requirements of ITB 4.2;
(h) Suspension: We, along with any of our subcontractors, suppliers, consultants, manufacturers, or service providers for any part of the contract, are not subject to, and not controlled by any entity or individual that is subject to, a temporary suspension or a blacklist or a debarment or banned as specified in Section 2, Clause 1.3. Further, we are not ineligible under the Purchaser’s country laws or official regulations or pursuant to a decision of the United Nations Security Council;
(i) Binding Contract: We understand that this Bid, together with your written acceptance thereof included in your Letter of Acceptance, shall constitute a binding contract between us, until a formal contract is prepared and executed;
(j) Not Bound to Accept: We understand that you are not bound to accept the lowest evaluated cost/price Bid, the Most Advantageous Bid or any other Bid that you may receive;
(k) Fraud and Corruption: We hereby certify that we have taken steps to ensure that no person acting for us, or on our behalf, engages in any type of Fraud and Corruption;
(l) (applicable only if the bidder is a Joint Venture as per Section 2 of RFB/ bidding document) We have bid as a Joint Venture as per Section 2 of RFB/ bidding document) and in accordance with Clause 2.2.7 of Section 2 we declare and confirm that all partners of the joint venture shall be liable jointly and severally for the execution of the contract in accordance with the contract terms;
(m) We submit appended herewith, as integral part of the Technical Part of our bid, the details/ documents as listed in the table below in the Forms duly filled, as prescribed, along with supporting documentary evidence as required/ specified. We understand and confirm that we would be solely responsible for any errors or omissions in our Bid and your decision in regard to sufficiency and/ or adequacy of the details/ documents comprising our Bid for determining its completeness shall be final and binding.
(n) We have read and understood the provisions of Order no. F.No.6/18/2019-PPD(Order Public Procurement no.1) dated 23/07/2020 regarding “Restriction under Rule 144(xi) of General Financial Rules” and F.No.6/18/2019-PPD (Order Public Procurement no.2) dated 23/07/2020 regarding “Exclusions from Restriction under Rule 144(xi) of General Financial Rules” issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India [hereinafter collectively “DoE Order’’] and any subsequent modifications/Amendments, if any. Particularly, we, the Bidder, have read the clause regarding restrictions on procurement from a ‘Bidder of a country which shares a land border with India’ and on sub-contracting to contractors from such countries. We certify that we, the bidder is not from such a country or, if from such a country, has been registered as per provisions of the Bidding Documents with the Competent Authority and will not subcontract any work to a subcontractor/sub vendor from such countries unless such subcontractor/sub vendorfulfils all requirement in this regard and is eligible to be considered. We further declare that any misrepresentation or submission of false/forged document/information in this regard shall be dealt with as per the provisions of Integrity Pact and/or Bidding Documents and/or POWERGRID’s policy and procedures
Sr. Document Status (Submitted/ Not Submitted/ Not Applicable)
1 This Letter of Bid as per format prescribed in Form 1 given in Section 4 of RFB/ bidding document
2 Bidder Information as per the format prescribed in Form 2 given in Section 4 of RFB/ bidding document Submitted
3 Bid Security or Bid Securing Declaration , as may be specified in ITB 18 Section 3 of RFB/ bidding document, in the form of specified in ITB . Bid Securing Declaration in format prescribed in Form 3A given in Section 4 and Bid Security in the form of Bank Guarantee in format prescribed in Form 3B given in Section 4 of RFB/ bidding document. Not Submitted
4 Power of Attorney by Lead Joint Venture Member/ Sole Bidder authorizing an Individual Designated Representative for the Joint Venture Bidder/ Sole Bidder as per the format prescribed in Form 4 given in Section 4 of RFB/ bidding document Not Applicable
4A List of Special Maintenance Tools & Tackles included in bid price in Form 4A given in Section 4 of RFB/ bidding document
4B List of Special Maintenance Tools & Tackles not included in bid price in Form 4B given in Section 4 of RFB/ bidding document
5 Declaration of conformance of the Bidder and the Facilities offered, to the specified eligibility requirement specified in Section 2 and Section 3, as per the format prescribed in Form 5 given in Section 4 of RFB/ bidding document
6A Local Content Certificate for Class I Local Supplier, as specified in Clause 1.5 of Section 2 of RFB/ bidding document, Affidavit of Self certification as per the format prescribed in Form 6A given in Section 4 of RFB/ bidding document or by certificate (format not specified) of Statutory Auditor, as may be applicable
6B Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order and MoP order, if applicable [to be submitted on the letter head of the issuer.], in line with specified in Clause 1.5 of Section 2 of RFB/ bidding document as per the format prescribed in Form 6B given in Section 4 of RFB/ bidding document
7 Power of Attorney by each member/ partner of the Joint Venture in favour of Lead member/ partner as per format prescribed in Form 7 given in Section 4 of RFB/ bidding document (applicable only for Joint Venture Bidder)
8 (A) Joint Deed of Undertaking (JDU) signed by each member/ partner of the Joint Venture, as per format prescribed in Form 8 given in Section 4 of RFB/ bidding document (applicable only for Joint Venture Bidder)
8 B Joint Venture Agreement entered amongst all the partners/ members of the Joint Venture in their own format but without violating any of the requirements of the bidding documents and necessarily including the confirmation as specified in Clause 2.2.7 of Section 2 of RFB/ bidding document (applicable only for Joint Venture Bidder)
9 Details/ Data and documentary evidence in support of meeting the Qualification Requirement specified in Section 2 of RFB/ bidding document, as per the format prescribed in Form 9 given in Section 4 of RFB/ bidding document
10 The details of all major items of Plant and Installation Services proposed to be subcontracted in case of award, indicating name and nationality of the proposed subcontractor/sub-vendor for each item, as per the format prescribed in Form 10 given in Section 4 of RFB/ bidding document as per the format prescribed in Form 1 given in Section 4
11 Form of Undertaking on Compliance of Terms & Conditions of the RFB/ bidding document including Scope of Work and other related requirements, as per the format prescribed in Form 11 given in Section 4 of RFB/ bidding document, subject to Sl No. 12 below of this table
12 Statement of Deviation from the requirements specified in the RFB/ bidding documents including Conditions of Contract, Employer’s Requirement/ Specification and Drawings etc, including, inter alia, the cost of withdrawal thereof, as per the format prescribed in Form 12 given in Section 4 of RFB/ bidding document
13 Work Completion Schedule, as per the format prescribed in Form 13 given in Section 4 of RFB/ bidding document
14 Guarantee Declaration, as per the format prescribed in Form 14 given in Section 4 of RFB/ bidding document
15 Information regarding ex-employees of Employer in our firm, as per the format prescribed in Form 15 given in Section 4 of RFB/ bidding document
16 Filled up information regarding Price Adjustment Data, as per the format prescribed in Form 16 given in Section 4 of RFB/ bidding document
17 Option for Interest bearing Initial Advance payment and Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises, as per the format prescribed in Form 17 given in Section 4 of RFB/ bidding document
18 Declaration for tax exemptions, reductions, allowances or benefits, as per the format prescribed in Form 18 given in Section 4 of RFB/ bidding document
19 Bank Guarantee verification checklist, as per the format prescribed in Form 19 given in Section 4 of RFB/ bidding document
20 Additional Information, if any, as per the format prescribed in Form 20 given in Section 4 of RFB/ bidding document
21 Integrity Pact, duly signed on each page by the person signing the bid, as per the format prescribed in Form 21 given in Section 4 of RFB/ bidding document
22 Declaration regarding events encountered pursuant to ITB Clause 1.8, as per the format prescribed in Form 22 given in Section 4 of RFB/ bidding document
23 Declaration of Key Managerial Person jointly with Power of Attorney holder, as per the format prescribed in Form 23 given in Section 4 of RFB/ bidding document
(n) We are also submitting herewith the Financial Part of our Bid, online separately, as per the prescribed Forms given in Section 5 of RFB/ bidding document, complete in all respects in electronic form only, as per the requirements of RFB/ bidding document. We confirm that the same does not contain any deviation, reservation or omission, failing which it is liable to be rejected.
(O) Contact Person
Details of the contact person representing us supported by the Power of Attorney, as prescribed, are furnished as under:
Designation: ………………………………………………….
For a joint venture, the lead partner of the joint venture shall furnish and declare the above Letter of Bid - Technical Part
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Price_schedule.xlsx
xlsx • 0.99 MB
Part-3.docx
docx • 0.58 MB
Annexure-A (BDS).docx
docx • 0.03 MB
FORM-1_Letter of Bid-TL02.xlsx
xlsx • 0.02 MB
Part-1.docx
docx • 0.41 MB
132kV-765kV DC std hw (Part-5).pdf
pdf • 8.03 MB
132kV-765kV DC std hw (Part-1).pdf
pdf • 9.30 MB
132kV-765kV DC std hw (Part-3).pdf
pdf • 7.94 MB
132kV-765kV DC std hw (Part-4).pdf
pdf • 8.39 MB
132kV-765kV DC std hw (Part-2).pdf
pdf • 10.32 MB
132kV-765kV DC std hw (Part-6).pdf
pdf • 3.53 MB
pile earthing Drawing.pdf
pdf • 0.30 MB
Revised Bird Guard Sheet 1 of 2.pdf
pdf • 0.10 MB
Revised Bird Guard Sheet 2 of 2 .pdf
pdf • 0.11 MB
Rod Type Earthing.pdf
pdf • 0.15 MB
Standard drum Drawing Conductor & Earth Wire.pdf
pdf • 0.71 MB
Steel Drum Drawing (HTLS Conductor).pdf
pdf • 0.25 MB
Tower & Access R1.pdf
pdf • 2.86 MB
Wooden Drum Drawing (HTLS Conductor).pdf
pdf • 0.22 MB
08_2Section VIII(Disc Insulator) .pdf
pdf • 0.66 MB
132kV and 220kV Typical Tower.pdf
pdf • 0.04 MB
220 KV SISP WITH BALANCING WT Model (1).pdf
pdf • 0.08 MB
220KV DT.pdf
pdf • 0.11 MB
220kV fittings with deer conductor.pdf
pdf • 0.38 MB
500HVDC- 765SC string drg.pdf
pdf • 0.86 MB
66KV STD FITTINGS.pdf
pdf • 2.24 MB
800kV HVDC string drg.pdf
pdf • 1.63 MB
BFD DRAWING.pdf
pdf • 0.52 MB
bird gurad for V String.pdf
pdf • 0.35 MB
Chemical Counterpoise.pdf
pdf • 0.10 MB
Chemical Pipe Type.pdf
pdf • 0.10 MB
Covered grading Ring Drawing.pdf
pdf • 0.62 MB
Extension application scheme.pdf
pdf • 0.06 MB
GA_A_PROP TYPE SST Model (1).pdf
pdf • 0.17 MB
HARD ROCK EARTHING.pdf
pdf • 0.19 MB
Individual Leg SST.pdf
pdf • 0.58 MB
Insulator Packing drawing PVC type.pdf
pdf • 0.88 MB
Insulator Packing drawing.pdf
pdf • 0.09 MB
12_Section XII FAQ.pdf
pdf • 0.37 MB
06_1 Section VI A Hardware Fittings Clamp and Accessories for Conductor & Earthwire Rev-2(Jan'22).pdf
pdf • 4.24 MB
07_1 Section VII A Conductor,Rev-2(Jan'2022).pdf
pdf • 1.15 MB
07_2 Section VII A (SMQP of Conductor).pdf
pdf • 4.76 MB
04_5 Section IVC Appendix II(Part-B) Precommissioning Formats, Rev-1 (Sept'2021).pdf
pdf • 2.38 MB
04_6 Section IVC Appendix III (SMQP of Trasnmission Line Tower.pdf
pdf • 3.40 MB
04_7 Section IVD Foundation (Contractor design),Rev-5(March'2023).pdf
pdf • 0.84 MB
05_1 Section V Earthwire.pdf
pdf • 0.37 MB
05_2 Section V (MQP for Earthwire).pdf
pdf • 0.90 MB
01_1 Section IA (standard)ScopeRev-6 (Feb'2023).pdf
pdf • 0.56 MB
01_2 Section IB General InformationRev-7(May 2023).pdf
pdf • 1.00 MB
02 Section II General Tehnical Conditions,Rev-2(Feb'2022).pdf
pdf • 0.84 MB
03_1 Section III Survey & Soil Investigation,Rev-3(March'2023).pdf
pdf • 0.91 MB
03_2 Section III Annexure-A(Format for site BOQ).pdf
pdf • 1.70 MB
03_3 Section III Annexure B-C-D-E(Formats for other site data).pdf
pdf • 0.48 MB
04_1 Section IVA Tower Design,Rev-4(Apr'2022).pdf
pdf • 0.33 MB
04_2 Section IVB Tower Testing,Rev-2(Mar'2023).pdf
pdf • 0.47 MB
04_3 Section IVC Fabrication, Erection & Stringing,Rev-6(APR'2023).pdf
pdf • 1.30 MB
04_4 Section IVC Appendix I (List of T&P).pdf
pdf • 0.83 MB
04_5 Section IVC Appendix II(Part-A) Precommissioning procedure, Rev-1 (Sept'2021).pdf
pdf • 1.89 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
OBD_EXTN_LETTER.pdf
pdf • 0.05 MB
REVISED 01_1 Section IA (standard)ScopeRev-6 (Feb'2023).pdf
pdf • 0.43 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
Clarification-I.pdf
pdf • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .