Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
25 Mar 2022, 11:15 amClosed
EE EnM M-3
DELHI JAL BOARD MU BLOCK PITAMPURA DLEHI-34
Maintaining water supply by replacement of LT Electric supply system at A-1 Sector 17 Rohini BPS.
2022_DJB_218999_7
NIT NO. 20(M-3)
Open Tender
Miscellaneous Works
Item Rate
15 days
EE EnM M-3
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹7,500
Yes
29 Mar 2022
16 Mar 2022
25 Mar 2022
16 Mar 2022
25 Mar 2022
16 Mar 2022
Supply / Fabrication of L T Panel Board cubical type, floor mounted stand, dust & vermin preventing construction, of the minimum size 1600 X 1500 X 350 mm, suitable for indoor fixing, made out of 16 SWG CRCA sheet (frame of 14 SWG), with provisions for cable entry from bottom and having chambers as- two incomer chambers (one each for the changeover and incomer MCCB), one metering chamber for the main incomer MCCB, two outgoing chambers for the star delta starters for 40 HP motors, one outgoing chamber for two nos. of lighting MCBs, 1 No. for Charging pump-set and 1 No. for de-watering pump set. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 300 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should be complete in all respect along with painted through powder coating process and with complete provisions suitable for all the switchgears as below to be fitted/ installed properly so as to make two incomers, one main metering module, one for lighting supply, one each for charging pump and dewatering pump set, two star delta starters with complete mounting accessories as per site requirement with complete internal connections of switchgears and control gears with the main bus bars in the Panel through copper cable or bus bars along with Making all the required wiring connections for all measuring and indicating instruments with all the accessories, thimbles, ferrules etc. complete in all respect as per requirement.
S/o Changeover, Switch, 250 Amp, 4 Pole, 415V AC. Make: -L&T/Schneider/HPL BCH/C&S/ Havells
S/o Moulded Case Circuit Breaker (MCCB) of rating 250 Amp, Triple Pole, 415V, AC of breaking capacity of 50 KA or more. Make:- L&T/Schneider/BCH/C&S
S/o Moulded Case Circuit Breaker (MCCB) of rating 125 Amp, Triple Pole, 415V, AC of breaking capacity of 36 KA or more. Make: -L&T/Schneider/BCH/C&S
S/o Moulded Case Circuit Breaker (MCCB) of rating 63 Amp, Triple pole, 415 V, AC of breaking capacity of 36 KA or more. Make: -L&T/Schneider/BCH/C&S
S/o spreader link 100 A triple pole 3 phase. Make L&T
S/o Power Contactor, 70 A, TP, 220V / 415V AC Make:-L&T/Schneider/BCH/C&S
S/o Power Contactor, 18 A, TP, 220V / 415V AC Make:-L&T/Schneider/BCH/C&S
S/o Power Contactor, 50 A, TP, 220V / 415V AC Make:-L&T/Schneider/BCH/C&S
S/O Motor protection Relay MPR 300 32-88 AMP Make: -L&T/Schneider/BCH/C&S
S/o Delay Timer for starter Make: -L&T/Schneider/BCH/C&S
S/o Add on block 1 No + 1 NC Make: -L&T/Schneider/BCH/C&S
S/o overload Relay for 40 HP motor, 30 – 50 Amp Make: L&T/Schneider/BCH/C&S
S/o overload Relay for 5HP motor 9-15 Amp Make:-L&T/Schneider/BCH/C&S
S/o Single Phase Preventer Make: -L&T/Schneider/BCH/C&S
S/o Push Buttons with contact Block Make:-L&T/Schneider/BCH/C&S
S/o Ampere Meter Digital type. Make: -L&T/Schneider/AE
S/o Volt Meter Digital type. Make: -L&T/Schneider/AE
S/o Indicating Lamp, LED type Make: -L&T/Schneider/BCH/C&S
S/o MCB, 6 Amps, SP, ‘C’ Curve. Make: -L&T/Schneider/BCH/C&S
S/o MCB, 63 Amps, FP, ‘C’ Curve. Make: -L&T/Schneider/BCH/C&S
S/o MCB, 32 Amps, TP, ‘C’ Curve. Make: -L&T/Schneider/BCH/C&S
S/o Current Transformer 300/5 ampere. Make: -AE/ Kuppa/ Matrix
S/o Current Transformer 100/5 ampere. Make: -AE/ Kuppa/ Matrix
S/O PVC insulated Single core Unsheathed industrial flexible cable confirming to IS 694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volt 16sq mm Make: - Gloster, Grandlay, Finolax, Polycab, Havells &Aproved in DJB SOR 43.1.6
4x35 sq. mm PVC insulated & PVC sheathed Aluminumarmored conductor cable confirming to IS: 1554 (Part-i) complete as required. Make: Make: - Gloster, Grandlay, Havells, Plaza, ICC, ICL, Universal & CCI. SOR 18.6.6
Dismantling of old panel board/ starters etc. and disconnecting all the old incoming and the outgoing connection and shifting the panel/ starters from the site to the JE stores.
Fixing of new base frame at the site with the help of fasteners / welding and grouting of nut bolts and including all other work as per site requirements and Fixing the new L T Panel at the newly fixed base frame by lifting the panel board and placing it at the base frame properly and fixing it to the frame by nut bolts as requirement. Fabrication and supply of base frame made out of Angle Iron of suitable size for fixing the above Panel and suitable for making outgoing/ incoming cable entries in the panel. It should be duly painted and ready with provisions for installing at the site.
Dismantling the existing Kit Kat fuse Board after disconnecting the cable connections. supply and fixing of kit kat board suitable for fixing the kit kat. Also providing the new Kit Kat of suitable rating and fixing the same by providing nut/ bolts/ fasteners etc. for the job as required.
Making the connection from the metering cubicle to the Kit Kat after laying of cable and, proper thimbling and tapping/ making end terminations etc. including providing & fixing of all the material & consumables as required at site.
Making the incoming connections to the Panel by connecting the existing cables after proper thimbling etc. including providing & fixing of consumables as per requirement. Making the outgoing connections of starters by Connecting outgoing starters to their respective pumps etc. Through existing cables as per site requirement after relaying of the cables as required, proper thimbling and tapping etc. including providing & fixing of material as per requirement. Making the outgoing connections of lighting DB by Connecting outgoing MCBs to the DBs etc. through the existing cables as per site requirement after relaying of the cables as required, proper thimbling and tapping etc. including providing & fixing of material as per site requirement.
Testing and Commissioning of the Panel Board first at NO LOAD and then at ON LOAD and Operation of pump sets and other E&M equipment to the satisfaction of engineer in charge. Loading, Unloading, Cartage and Transportation charges for the above Panel up to the site including charges of heavy labour etc.
JMD ASSOCIATES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .