Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹53.8 L
Closing Date
27 Oct 2026, 3:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
SE (Purchase) SSTPP MPPGCL Dongali
O/o Addl. C.E.(PandW), SSTPP
Procurement of Schneider Electric make Current Transformers (CTs) installed in 11KV/6.6KV HT switchgears of BTG and BOP area at 2X660MW SSTPP, Stage-II, MPPGCL, Khandwa.
2026_MPPGC_542332_1
PT-3921
Single
Miscellaneous Goods
Item Wise
60 days
O/o Addl. C.E.(PandW), SSTPP
As per tender documents
15 documents required · 15 mandatory
₹0
Exempted
13 Oct 2026
13 Oct 2026
30 Oct 2026
13 Oct 2026
27 Oct 2026
13 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Current Transformer: CT SCALE CT Ratio: 3150/1,1A; Freq. 50Hz, BIL:12/35/75 kVp, Ins. Class: E, STC 40kA/1SEC, Conform to IEC 61869-1&2, RCT≤23.5 Ohms at 75˚C (Core-1, 2)
VA & ClASS: CORE-1: Class: PS, Vk≥1550V, I0≤20mA at VK/2. CORE-2: Class: PS, Vk≥1550V, I0≤20mA at VK/2. TYPE: BAR Make- Schneider Electric; Model- GBP-1/1
SR.NO. 38930N948/331454
Panel Sr.No.:7505142283/12/1S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 2 | Current Transformer: CT SCALE CT Ratio: 3150/1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class: B, Ith 40kA/1SEC, conform to IEC 61869-1&2
VA & Class: CORE-1: Class:5P20; Burden :15 (VA),
CORE-2: Class:0.2; Burden :15 (VA); ISF: ≤5;
TYPE: BAR Make- Schneider Electric
Model- GBP-1/1
SR.NO. 16/01068
Panel Sr.No.:7505142283/12/1S
1 Set (R,Y,B ph.) = 3 Nos. | 1 | Nos | - | - |
| 3 | Current Transformer: CT SCALE CT: Ratio: :1250/1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: Class: PS, VK=≥57(RCT+2) V, R. SEC=≤11Ω, Iexe=≤20mA@VK/2
CORE-2: Class: PS, VK=≥57(RCT+2) V, R. SEC=≤11Ω, Iexe=≤20mA@VK/2
TYPE: WINDOW Make- Schneider Electric
Model- ARE1
SR.NO. 16/009187
Panel Sr.No.: 7505142283/02/1S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 4 | Current Transformer: CT SCALE CT: Ratio: Ratio: 1250/1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: Class:5P20; Burden :15 (VA),
CORE-2: Class:0.2; Burden :15 (VA); ISF: ≤5;
TYPE: WINDOW Make- Schneider Electric
Model- ARE2
SR.NO. 16/014336
Panel Sr.No.: 7505142283/01/15S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 5 | Current Transformer: CT SCALE CT: Ratio: 1250/1,1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: Class: PS, VK-≥260V, R RSEC- ≤5Ω, Iexe-≤20mA@VK/2
CORE-2: Class:5P20; Burden :15 (VA),
CORE-3: Class:0.2; Burden :15 (VA); ISF: ≤5;
TYPE: WINDOW Make- Schneider Electric
Model- ARE3
SR.NO.16/008964
Panel Sr.No.: 7505142283/12/10S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 6 | Current Transformer: CT SCALE CT: Ratio: 400/1,1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: Class: PS, VK=≥183V, R. SEC=≤2.6Ω, Iexe=≤20mA@VK/2
CORE-2: Class:5P20; Burden :15 (VA),
CORE-3: Class:0.2; Burden :15 (VA); ISF: ≤5;
TYPE: WOUND Make- Schneider Electric
Model- GWP5/1
SR.NO. 16/009190
Panel Sr.No.: 7505142283/02/15S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 7 | Current Transformer: CT SCALE CT: Ratio: 400/1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: Class:5P20; Burden :15 (VA),
CORE-2: Class:0.2; Burden :15 (VA); ISF: ≤5;
TYPE: WOUND Make- Schneider Electric
Model- GWP6/1
SR.NO. 16/008946
Panel Sr.No.: 7505142283/12/7S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 8 | Current Transformer: CT SCALE CT: Ratio: 300/1,1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: VK=≥183V, R. SEC=≤ 2.6Ω, Iexe=≤20mA@VK/2 CORE-2: Class:5P20; Burden:15 (VA),
CORE-3: Class:0.2; Burden:15 (VA); ISF: ≤5;
TYPE: WOUND Make- Schneider Electric
Model- GWP5/1
SR.NO. 16/009131
Panel Sr.No.: 7505142283/02/13S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 9 | Current Transformer: CT SCALE CT: Ratio: 200/1,1,1A; Freq. 50Hz, Insulation level:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: VK=≥183V, R. SEC=≤ 2.6Ω, Iexe=≤20mA@VK/2 CORE-2: Class:5P20; Burden:15 (VA), CORE-3: Class:0.2; Burden:15 (VA); ISF: ≤5;
TYPE: WOUND Make- Schneider Electric
Model- GWP5/1
SR.NO. 16/009126
Panel Sr.No.: 7505142283/02/10S
1 Set (R,Y,B ph) = 3 Nos. | 1 | Nos | - | - |
| 10 | Current Transformer: CT SCALE CT: Ratio:150/1,1A; Freq. 50Hz, HSV/IL:12/35/75 kVp, Insulation Class:B, Ith 40kA/1SEC, Conform to IEC 61869-1&2
VA & ClASS: CORE-1: Class:5P20; Burden:15 (VA),
CORE-2: Class:0.2; Burden:15 (VA); ISF: ≤5;
TYPE: WOUND Make- Schneider Electric
Model- GWP6/1
SR.NO. 16/009082
Panel Sr.No.: 7505142283/02/4S
2 Set (R,Y,B ph) = 6 Nos. | 2 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.41 MB
Tendernotice_2.pdf
PDF • 0.39 MB
annexures3921.pdf
Tender Documents • 0.56 MB
DetailedNIT.pdf
Tender Documents • 0.39 MB
Tenderschedule.pdf
Tender Documents • 0.37 MB
ShortNIT.pdf
Tender Documents • 0.44 MB
NEWSBD2.pdf
Tender Documents • 19.94 MB
Checklist.pdf
Tender Documents • 0.39 MB
BOQ_652935.xls
BOQ • 0.26 MB
Credentials.xls
Additional Documents • 0.09 MB
ModelCertificate.pdf
Additional Documents • 0.17 MB
TCBid.xls
Additional Documents • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .