| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹50.7 LAccepted-AOC 1 OPP SUGAR MILL KARNAL ROAD KAITHAL 136027 | KAITHAL | HARYANA | 136027 | 1 | Accepted-AOC Award Contract to L1 | |
| 2 | 2₹54.2 L+₹3.5 L (6.84%)Rejected-Finance RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | 2 | Rejected-Finance L2 | |
| 3 | 3₹60.1 L+₹9.3 L (18.4%)Rejected-Finance KARNAL ROAD KAITHAL | 3 | Rejected-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical JIND | JIND | HARYANA | 126101 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical 2418 19 URBAN ESTATE JIND 126102 | JIND | JIND | HARYANA | 126102 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Jan 2024, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Exective Officer
Vita Milk Plant Jind
CONSTRUCTION OF BLAST AND CIP ROOM VITA MILK PLANT JIND
2023_HBC_335523_1
CONSTRUCTION OF BLAST AND CIP ROOM VITA M P JIND
Open Tender
Civil Works - Buildings
Works
90 days
Jind
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹1 L
Yes
Meeting Hall Vita Milk Plant Jind
20 Mar 2024
18 Dec 2023
9 Jan 2024
18 Dec 2023
8 Jan 2024
19 Dec 2023
22 Dec 2023
Civil work for Construction of CIP Room
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including Dewatering and getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. All Kinds of soil
Filling available excavated earth (excluding rock) in trenches, cum plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Supplying and filling earth/soil including compaction,ramming,etc in 20 cm layers.
Dismantling C.I.tiles works
Demolishing cement concrete manually/ mechanically means including disposal of materials within 50 M lead as per direction of engineer-in-charge nominal concrete 1:2:4
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Removing mortar bricks and cleaning bricks including stacking within a lead of 50 m
Shuttering:- Centering and shuttering including strutting, propping etc. and removal of formwork for
Foundations, footings, bases for columns
Columns, piers, abutments, pillars, posts and struts
Centering and shuttering including strutting, propping etc. and removal of formwork for Suspended floors, roofs, landings, balconies
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Concrete work
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: : 1:4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works up to plinth level
All works above plinth level up to floor IV level
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) 40 mm thick
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Thermo-Mechanically Treated bars of grade Fe-500D kgor more.
Thermo-Mechanically Treated bars of grade Fe-500D kgor more.
Brick work
Brick work with common burnt clay non- modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) upto 3rd Storey
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand)
Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level. cement mortar 1:4 (1 cement: 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of half brick masonry.
Roofing
Painting top of roofs with bitumen of approved quality @ 17kg per 1 O sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete With residual type petroleum bitumen of grade VG -1 O
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class sqm designation 10
Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 150 mm diameter
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler 150 mm
Single push fit Coupler 150 mm
Single tee with door 150 mm
Single tee without door 150 mm
Bend 87.5 150 mm
Shoe (Plain) 150 mm
Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1 :4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 150 mm diameter
Flooring
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling.
Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying of screed of 50 mm thick cement concrete 1 :8:16 to be laid below the topping.
Mandana Stone Flooring 34 mm to 40 mm thick in my pattern as specified over 12 mm thick base of cement coarse sand mortar 1 :3 and jointed with epoxy resin compound keeping 6 mm to 10 mm joint all around with pigment to match the shade of stone including rubbing and polishing ass per specificaiton. The joint be raked 12 mm to 19 mm deep.
Mandana Stone Skirting over 12 mm thick bed of cement mortar 1:3 and jointing with matching pigment
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Plastering
12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) Up to 3rd Storey
15 mm cement plaster on the rough side of single or half brick wall of mix :1 :4 (1 cement: 4 fine sand)
10 mm thick cement plaster 1 :3 (1 cement: 3 fine sand) Up to 3rd Storey
Painting
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and mooth finish including cost and carriage of all material , labour harges, scaffolding, sundries etc. complete
provding and applying POP Putty of 2mm thickness over plaster surface to prepare the surface even and smooth complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
Aluminium fittings
Providing and fixing Aluminuim Glazing in Specified door the Glazing to include section of frame of 4'' x 1.75'' and that of door shutter shall be 3''x1.5'' and 5 mm thick glass of saint goban/modiflote /aadalin with proctective lineing film over it or ACP sheet 2mm as per design including all necessory hardware like hangers stays bolt etc. The aluminium section to be used 16 gauge.
Providing and fixing Aluminuim Glazing in Specified window the Glazing to include section of frame of 2.25'' x 1.50'' and that of in frame shall be 1.5''x1.5'' and 5 mm thick glass of saint goban/modiflote /asahi with proctective lineing film over it or ACP sheet 2mm as per design including all necessory hardware like hangers stays bolt etc. The aluminium section to be used 16 gauge.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Electrical Work for Construction of CIP Room
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.
1 run of Size 1.50 Sqmm(1/1.40mm)
1 run of Size 2.50 Sqmm(1.1.80mm)
1 run of Size 4 Sqmm(1/2.24mm)
1 run of Size 6 Sqmm(1/2.80mm)
2 run of Size 1.50 Sqmm(1/1.40mm)
2 run of Size 2.50 Sqmm(1.1.80mm)
2 run of Size 4 Sqmm(1/2.24mm)
3 run of Size 1.50 Sqmm(1/1.40mm)
3 run of Size 2.50 Sqmm(1.1.80mm)
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT
Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as .required Group B
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B
Erection of exhaust fan in existing opening, complete with necessary earthling of fan including carriage from PWD store to the site of work.
Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work.
Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
Supply, erection and fixing of 12 mm thick ply wood board having a circular sqft 141 /rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labour etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required
Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling including cutting/making hole in ceiling including making connections etc as required
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc.
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.
Double pole MCCB 16 to 63 Amp, 25 Ka
6 amp. to 32 amp Double POLE
MISCELLANEOUS
Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):-
Size 15 mm dia
Size 20 mm dia
Size 25 mm dia
CEILING FAN/ EXHAUST FAN
Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge
Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge.
Provding And Supply of Led Tube Light. Make-Philips/wipro/havells/syska
Provding And Supply of Wipro Wall Light. Make -Philips/wipro/havells/syska
Description of Work / Item(s)
Civil work for Construction of BLAST Room
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including Dewatering and getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. All Kinds of soil
Filling available excavated earth (excluding rock) in trenches, cum plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Supplying and filling earth/soil including compaction,ramming,etc in 20 cm layers.
Dismantling C.I.tiles works
Demolishing cement concrete manually/ mechanically means including disposal of materials within 50 M lead as per direction of engineer-in-charge nominal concrete 1:2:4
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Removing mortar bricks and cleaning bricks including stacking within a lead of 50 m
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge.
Demolishing mud phaska in terracing and disposal of material within 50 metres lead.
Demolishing brick tile covering in terracing including stacking of sqm serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge.
Shuttering:- Centering and shuttering including strutting, propping etc. and removal of formwork for
Foundations, footings, bases for columns
Columns, piers, abutments, pillars, posts and struts
Centering and shuttering including strutting, propping etc. and removal of formwork for Suspended floors, roofs, landings, balconies
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Concrete work
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: : 1:4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works up to plinth level
All works above plinth level up to floor IV level
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) 40 mm thick
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Thermo-Mechanically Treated bars of grade Fe-500D kgor more.
Thermo-Mechanically Treated bars of grade Fe-500D kgor more.
Brick work
Brick work with common burnt clay non- modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) upto 3rd Storey
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand)
Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level. cement mortar 1:4 (1 cement: 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of half brick masonry.
Roofing
Painting top of roofs with bitumen of approved quality @ 17kg per 1 O sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete With residual type petroleum bitumen of grade VG -1 O
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class sqm designation 10
Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 150 mm diameter
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler 150 mm
Single push fit Coupler 150 mm
Single tee with door 150 mm
Single tee without door 150 mm
Bend 87.5 150 mm
Shoe (Plain) 150 mm
Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1 :4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 150 mm diameter
Flooring
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling.
Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying of screed of 50 mm thick cement concrete 1 :8:16 to be laid below the topping.
Mandana Stone Flooring 34 mm to 40 mm thick in my pattern as specified over 12 mm thick base of cement coarse sand mortar 1 :3 and jointed with epoxy resin compound keeping 6 mm to 10 mm joint all around with pigment to match the shade of stone including rubbing and polishing ass per specificaiton. The joint be raked 12 mm to 19 mm deep.
Mandana Stone Skirting over 12 mm thick bed of cement mortar 1:3 and jointing with matching pigment
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) :25 mm thick
Plastering
12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) Up to 3rd Storey
15 mm cement plaster on the rough side of single or half brick wall of mix :1 :4 (1 cement: 4 fine sand)
10 mm thick cement plaster 1 :3 (1 cement: 3 fine sand) Up to 3rd Storey
Painting
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and mooth finish including cost and carriage of all material , labour harges, scaffolding, sundries etc. complete
provding and applying POP Putty of 2mm thickness over plaster surface to prepare the surface even and smooth complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
Aluminium fittings
Providing and fixing Aluminuim Glazing in Specified door the Glazing to include section of frame of 4'' x 1.75'' and that of door shutter shall be 3''x1.5'' and 5 mm thick glass of saint goban/modiflote /aadalin with proctective lineing film over it or ACP sheet 2mm as per design including all necessory hardware like hangers stays bolt etc. The aluminium section to be used 16 gauge.
Providing and fixing Aluminuim Glazing in Specified window the Glazing to include section of frame of 2.25'' x 1.50'' and that of in frame shall be 1.5''x1.5'' and 5 mm thick glass of saint goban/modiflote /asahi with proctective lineing film over it or ACP sheet 2mm as per design including all necessory hardware like hangers stays bolt etc. The aluminium section to be used 16 gauge.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Electrical Work for Construction of Blast Room
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.
1 run of Size 1.50 Sqmm(1/1.40mm)
1 run of Size 2.50 Sqmm(1.1.80mm)
1 run of Size 4 Sqmm(1/2.24mm)
1 run of Size 6 Sqmm(1/2.80mm)
2 run of Size 1.50 Sqmm(1/1.40mm)
2 run of Size 2.50 Sqmm(1.1.80mm)
2 run of Size 4 Sqmm(1/2.24mm)
3 run of Size 1.50 Sqmm(1/1.40mm)
3 run of Size 2.50 Sqmm(1.1.80mm)
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT
Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as .required Group B
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B
Erection of exhaust fan in existing opening, complete with necessary earthling of fan including carriage from PWD store to the site of work.
Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work.
Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
Supply, erection and fixing of 12 mm thick ply wood board having a circular sqft 141 /rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labour etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required
Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling including cutting/making hole in ceiling including making connections etc as required
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc.
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.
Double pole MCCB 16 to 63 Amp, 25 Ka
6 amp. to 32 amp Double POLE
MISCELLANEOUS
Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):-
Size 15 mm dia
Size 20 mm dia
Size 25 mm dia
CEILING FAN/ EXHAUST FAN
Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge
Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge.
Provding And Supply of Led Tube Light. Make-Philips/wipro/havells/syska
Provding And Supply of Wipro Wall Light. Make -Philips/wipro/havells/syska
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .