| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-Finance | L1 | Accepted-Finance Accepted as 1st Lowest Bidder for the execution of subjected work | |
| 2 | L2₹3.9 L+₹14,935 (4.03%)Accepted-Finance | L2 | Accepted-Finance Accepted as 2nd Lowest Bidder for the subjected work | |
| 3 | L3₹3.9 L+₹20,838 (5.63%)Accepted-Finance | L3 | Accepted-Finance Accepted as 3rd Lowest Bidder for the subjected work | |
| 4 | L4₹3.9 L+₹20,995 (5.67%)Accepted-Finance | L4 | Accepted-Finance Accepted as 4th Lowest Bidder for the subjected work | |
| 5 | L5₹4.1 L+₹41,693 (11.3%)Accepted-Finance | L5 | Accepted-Finance Accepted as 5th Lowest Bidder for the subjected work |
Tender Value
₹4.4 L
EMD Value
₹8,700
Closing Date
6 Oct 2022, 4:00 pmClosed
Executive Engineer, KPDCL, ED2nd, Rajbagh,Srinagar
Office of the Executive Engineer, KPDCL, ED2nd, Rajbagh, Srinagar
Creation of 25 kVA, 11/0.433 KV Dedicated Sub-Station at M/S United Service Station (Dealer -BPCL), Tengpora Byepass, Bemina, Srinagar -(Sub-Division Hazuribagh) - on SITC Basis
2022_PDD_189249_1
ED-II/09 of 2022-23 Dated 20/09/22
Open Tender
Electrical Works
Turn-key
15 days
M/S United Service Station, Tengpora Byepass, Sgr
Please refer Tender documents.
7 documents required · 7 mandatory
₹200
Ex. Engineer,KPDCL, ED2nd Credited to MH0801 Power
₹8,700
31 Oct 2022
21 Sept 2022
7 Oct 2022
21 Sept 2022
6 Oct 2022
22 Sept 2022
21 Sept 2022 - 22 Sept 2022
Amount
Supply, Installation, Testing and Commissioning of 25 kVA 11/0.433kV, 3-phase Distribution Transformer (Aluminium Wound) with Bimetallic Terminal Connectors (HT / LT side both) - (Energy Efficiency Level 1 as per Amendment 4 to IS:1180 (Part -1) : 2014), with LV Cable Box having detachable Aluminium Gland plate. The Job shall also include loading, carriage and unloading upto site. All test certificates as mandated as per amendment 4 to IS-1180 (Part-I) : 2014 are to be provided by the bidder
Providing and Erection of ST Pole 9 mtr (ST 410 SP-33) including its loading, carriage and unloading upto site.
Providing and Erection of ST Pole 8 mtr (ST 410 SP15) including its loading, carriage and unloading upto site.
Supply, Laying, Testining and Commissioning of 0.03 ACSR Conductor
Providing and Fixing of 0.05 ACSR conductor for tapping/ jumpering
Supply, Laying, Testining and Commissioning of 50 mm² three & half Core Cable,1.1K V Grade, AL Conductor XLPE Insulated Stranded Conductor FRLS type (Armoured)
Supply, Installation, Testing and Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type comprising of 9 No. insulators, pipes and lock pad etc complete job
Supply, Installation, Testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply, Installation, Testing and Commissioning of 11 kV Gapless Surge Arrestor, 9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing, Fabrication and Fixing of Transformer Base Channels G.I (100X50 ISMC) 2.74 metre long (2 Nos)
Providing, Fabrication and Fixing of Top Channels G.I (100X50 ISMC) 2.7 metre long (2 Nos)
Providing, Fabrication and Fixing of G.I channels (75X40 ISLC) 2.72 mtr long (2 Nos) for AB switch mounting
Providing, Fabrication and Fixing of G.I Channel (75X40 ISLC) 2.74 meter long (1 No) for DO-Fuse Mounting
Providing, Fabrication and Fixing of G.I Channel (65X65X6 ISLC) for LTDB & LT- meter fixing angle 2.76 metre long (2 Nos)
Providing, Fabrication and Fixing of Channel Support for TRMO Op-Rod Top and Bottom (75X40 ISLC) 0.515 meter long (2 No)
Providing, Fabrication and Fixing of Transformer Belting Angles (75X40 ISLC) 2.73 metre long (2 Nos)
Providing, Fabrication and Fixing of Bracing support for operating handle (50X80 ISLC) 500 mm (1 No)
Providing, Fabrication and Fixing of Channel Support For Operating Handle Top (75X40 ISLC) 0.515 m long (1 No)
Providing, Fabrication and Fixing of LT DB (MCCB Box) and meter fixing angles 2 Nos (65x65x6mm)
Providing, Fabrication and Fixing of Bracing support (50X80 ISLC) 500 mm (1 No) for operating handle
Providing and Fixing of GI Pole collars 50x8 mm (Back Clamps Dimensions as per Drawing attached) for D.O/Fuse/Operating handle/ AB Switch/Belting Angle etc (1.44 kg weight per Clamp)
Providing and Fixing of Galvanised Nuts and bolts with washers
Providing and Fixing of 11 kV Polymeric composite Pin Insulator 12 kV, 5 kN, Lighting Impulse 75 kV Positive and 80kV Negative, creepage distance 320mm
Supply, Installation, Testing and Commissioning of 3-Ø, 4-Wire Trivector Meter (complete)
Providing and Fixing of Aluminium Solderless Clamps for 25 kVA transformer
Providing and Fixing of Aluminium Lugs 50 sq mm
Providing and Laying of Earthing of substation Complete with all accessories --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. Interconnection of 3 earthing pipes by 50x60 mm GI Flat. GI Strip of size 25 mm x 3 mm for neutral earthing (Two distinct connections) / connection of transformer body and LA. besides 8 sgw GI Wire conncetions for Transformer body , LT Distribution Box (2 connections) , AB Switch Handle (2 distinct conncetions) and earthing terminal of Poles (Description as per Approved Drawing Titled Earthing for 100/63 KVA DTR on 9 mtr Poles -CE/P&P/Drg/2022DTR007)
Supply, Installation, Testing and Commissioning of MCCB 40 Amps MCCB TPN with enclosure (1.6 mm Tick CRCA Sheet made) and two earthing bolts
Providing and Fixing of 11 KV Danger Plates with clamps
Providing and Fixing of GI Barbed wire for Anticlimbing with end Clamps
Providing and Fixing of Wedge Connectors / PG Clamps
Providing, Fabrication and Fixing of Galvanized V Cross-Arms duly fabricated of size 75x40x6mm Channel Iron Cross Arm with 04 No. (50x50x6mm) welded flat iron plates (Total Wt. 10.5 Kg) as per Drg. No. CE/P&P/DRG/2022/11KVL001)
Providing and Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fittings
Providing and Fixing of GI Muki Clamp of 50x8 mm galvanized flat iron (0.75 Kg per No.) having end inner dia 18 mm for Shackle Insulators suitable for ST Pole with back clamp and galvanized nuts and bolts
Providing and Fixing of 16 kN Polymer Shackle Insulators
Providing and Laying of Earthing of ST Pole 9 mtr long (Complete) by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Providing and Laying of Earthing of ST Pole 8 mtr long (Complete) by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Providing and Painting of ST poles 9 mtr long with 2 coats of Red Oxide & 1 coat of Aluminium Paint
Providing and Painting of ST poles 8 mtr long with 2 coats of Red Oxide & 1 coat of Aluminium Paint
Providing and Laying of Cement Bottoming of ST Pole 9 mtr long in the ratio 1:2:4 mix as per REC standards 0.5cum/pole
Providing and Laying of Cement Bottoming of ST poles 8 mtr long in the ratio 1:2:4 mix as per REC standards 0.45cum/pole
M/S QADRI ELECTRICALS
UBAID SUPPLIERS AND CONTRACTORS
M/S POWER PROS ELECTRICAL CO
Alamdar Electricals
M/S NEW MIR ELECTRICALS WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .