Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical REJECT |
Tender Value
₹94.9 L
EMD Value
₹95,000
Closing Date
12 Oct 2023, 12:00 pmClosed
SE, EUDC, MATHURA
SE, EUDC OFFICE, NEAR TANK CHAURAHA, MATHURA
Carrying out various electric works on Semi Turn Key Basis for System Strengthening in Business Plan Scheme in the area of EE, EUDD I, Mathura under the jurisdiction of SE, EUDC, Mathura
2023_DVVNL_840225_3
44/EUDC(M)/2023-24
Open Tender
Electrical Works
Turn-key
90 days
EE, EUDD I
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
dvvnl.org
₹95,000
10 Nov 2023
3 Oct 2023
12 Oct 2023
3 Oct 2023
12 Oct 2023
3 Oct 2023
Cartage of following material from Store centre, Mathura to work site.
ST Pole (11 mtr. Long) (SP-55) Bottom portion galvanized
ST Pole (13 mtr. Long) (SP-70) Bottom portion galvanized
11/0.4 KV 400 KVA T/F
11/0.4 KV 250 KVA T/F.
11/0.4 KV 100 KVA T/F.
LT XLPE/PVC cable 1cx630 sq.mm.
LT XLPE cable of size 3.5x240 Sq. mm.
LT XLPE cable of size 3.5x150 Sq. mm.
LT XLPE cable of size 3.5x70 Sq. mm.
2Cx10 Sq.mm. armoured Cable
4x10 Sq.mm. armoured Cable
33 KV XLPE Cable 3x300 Sq.mm.
11 KV XLPE Cable 3x185 Sq.mm.
11 KV XLPE Cable 3x120 Sq.mm.
11 KV VCB for O/G CTR 200/100/5A, 350 MVA
33 KV Control Panel for Double T/F
ACSR Dog conductor
ACSR Ins. Weasel conductor
33 KV Ligtening Arrestor
33 KV Fuse Set
33 KV Line Isolator 800 Amp.
33 KV Post Insulator
G.I. Wire for Guarding Angle
Cable Jointing Kit 33 KV 3x300 Sq.mm. O/D
Cable Jointing Kit 33 KV 3x300 Sq.mm. S/T
Cable Jointing Kit 11 KV 3x120 Sq.mm. O/D
Cable Jointing Kit 11 KV 3x120 Sq.mm. S/T
Cable Jointing Kit 11 KV 3x185 Sq.mm. O/D
Cartage of above material like various size 33 KV, 11 kv cable, dog/weasel conductor, Jointing kit, vaccume interrupter, distribution transformers, ST/PCC Pole, insulator, control panel, pin insulator, bus isolator, brass glands, channel, clamps etc. from Store Center, Mathura to work site and dismentled material from site to dvvnl store.
Digging of pit & erection of new single support ST Pole (13/11 mtr. long) including grouting of pole and fixing of all clamps, cross arm, pin/disc insulator & other accessories with providing stone pad as per relevant drawings. Any fabrication if required for above support.
Digging of pit & erection of new Double Pole Structure ST Pole (13/11 mtr. long) including grouting of pole and fixing of all Sturucture accessories, clamps, cross arm, pin/disc insulator & other accessories with providing stone pad as per relevant drawings. Any fabrication if required for above support.
Grouting of ST Pole with cement, sand, concrete, (CC will be of cement, coarse sand & brick balleast Grouting will be done with the help of wooden/steel formers in a block of size 900mm X 450mm X 1/3 of the full of the support in the CC 1:4:8 as per relevant drawing including back filling & proper ramming.
Providing & Fixing/Installation of 33/0.4 KV, 250 KVA S/S
Providing & Fixing of M.S. Top Channel (125x65x3200 mm)
Providing & Fixing of M.S. Top Channel (125x65x2240 mm)
Providing & Fixing of M.S. Dropper Channel (100x50x2028 mm)
Providing & Fixing of MS Angle (65x65x6x3800 mm) Bracing Set with 04 No. Clamp
Providing & Fixing of MS Angle (65x65x6x2700 mm) Bracing Set with 04 No. Clamp
Providing & Fixing of M.S. Angle for T/F Base
Providing & Fixing of M.S Tee Chanel with Clamp & Nut Bolts, Washer's.
Fixing/Installation of 33 KV L.A.
Fixing/Installation of 11 KV VCB for O/G CTR 200/100/5A, 350 MVA
Earthing of ST/PCC pole/Body earthing of T/F. by M.S earth rod.
Providing & Fixing of MS Nut, Bolt and Washer's
Painting of ST pole.
Digging of pit & erection of Stay rod with grouting cement sand and brick ballast including Nuzzling, binding Complete. (Stay Insulator providing by contractor)
Overhauling of 08 MVA Power T/F at 33/11 KV S/S Cannt, Mathura including following works with required accessories.
Opening of all connection of 08 MVA Power Transformer
Drain Out of Transformer Oil for Replacement of Damaged Packing
Lifting of Top Cover by the help of Crain for replaceement of damaged packing of Top Cover, Inspection Plate including removal damage packing and surface after then fixing of New Packing and Top Cover, Inspection Plate including tighting of Nut & bolts.
Replacement of LT Side Rod
Opening of radiator and removal of damage packing
Fixing of new packing radiator and fixing of radiator of 08 MVA T/F
Opening of the Conservator Tank by the help of Crain removal of damage packing cleaning of surface fixing of new packing and fitting of Conservator Tank
Opening of 33 KV, 11 KV bushing rod very carefully and removal of damage packing and replacement of new packing and fixing of 33 KV, 11 KV Bushing Rod Complete.
Filling of Transformer Oil
Making of All Connection of 08 MVA Power Transformer
Connection of 33 KV Isolator, Post Insulator, Fuse Set, Transformer by the fitting of connecting clamp
Water Level Earthing Complete
Laying of 2Cx10 Sq.mm. amoured Cable
Laying of 4x10 XLPE amoured cable with catenary
Providing & fixing of PVC Pipe 2" diameter
Providing & fixing of PVC Pipe 3" diameter
Providing & fixing of 10 sq.mm. aluminium thimble
Providing & fixing of 16 sq.mm. aluminium thimble
Providing & Laying of 33 KV XLPE Cable 3x50 Sq.mm.
Providing & Fixing of 33 KV XLPE Cable J/K. 3x50 Sq.mm. O/D & I/D
Special Plinth for 630 KVA T/F Construction of Distribution T/F foundation and plinth on RCC pillar as per mentioned and provided dimensions drawing structure and specified details for the same. Due to exception case to be taken food suumerzed area world level monumentle temple situation and safety purpose.
Sagging of 33/11KV line on Dog conductor on erected poles.
Jumpering/Fixing by ACSR Ins. Weasel Conductor on T/F, D/P, T/P, F/P. Etc.
Laying of LT XLPE/PVC cable 1cx630 sq.mm.
Laying of LT XLPE/PVC cable 3.5cX400/240/150/70 sq.mm.
Stringing & Sagging of G.I. Wire for Guarding (6&10 SWG)with biding the arrows (tilli distance appr. 02 Mtr.)
Providing & fixing of Guarding Angle for 33/11 KV Line
Providing & fixing of I Bolt for Guarding
Providing & fixing of Aluminium Biding Wire for Guarding
Providing & fixing of Aluminium Biding Wire 6 SWG
Providing & fixing of clamp for guarding angle for 11 KV line
Installation of Distribution box on ST Pole/PCC Pole for LT Line.
Providing & fixing of Earth Wire Clamp
Providing & fixing of Armoured Rod with ferules for 33 KV (Dog)
Providing & fixing of Danger Board
Providing & fixing of Barbed Wire
Providing & fixing of Stone Pad
Providing & fixing of P.G. Clamp for 33 KV & 11 KV Line
Painting of Subsation structure
Providing for Clamp for HDPE Pipe
Providing & fixing/Installation of LT Protection for 250 KVA T/F (as per Technical Specification)
Providing & fixing of Number Plate for Yard Equipment of nomeclature
Providing & fixing of buchholz relay for control panel
Fixing/Installation of 33 KV Fuse Set
Providing of Structure for 33 KV Fuse Set
Fixing/Installation of 33 KV Line Isolator
Providing of Structure for 33 KV Line Isolator
Fixing/Installation of 33 KV Post Insulator
Providing of Structure for 33 KV Post Insulator
Providing, fixing/filling of Breather for Power T/F with silca gel
Providing & fixing of G.I. Pipe with capping
Providing & fixing of G.I. Pipe Clamp
Fixing of 33 KV V type Steel Cross Arm
Fixing of 11 KV V type Steel Cross Arm
Fixing of 11 KV Pin Insulator with pin
Fixing of 33 KV Pin Insulator with pin
Fixing of Disc Insulator 45 KN & 70 KN (T&C/B&S)
Fixing of Disc fitting 45 KN & 70 KN (T&C/B&S)
Providing & fixing of 33 KV KV F Bracket
Providing & fixing of 11 KV KV F Bracket
Providing & fixing of Packing Piece Clamp for 33 KV/11 KV/Guarding with nut & bolts
Providing & fixing of Aluminium Lug 630 Sq.mm.
Providing & fixing of Aluminium Lug 240 Sq.mm.
Providing & fixing of Aluminium Lug 150 Sq.mm.
Providing & fixing of ST Pole Clamp
Providing & fixing of Hot Dip Galvanized cable support clamp for cable
Filling & fixing of Cable Jointing Kit 33 KV 3x300 Sq.mm. Outdoor type
Fixing of 33 KV Straight Through of size 3x300 Sq.mm.
Filling & fixing of Cable Jointing Kit 11 KV 3x120 Sq.mm. Outdoor type
Fixing of 11 KV Straight Through of size 3x120 Sq.mm.
Filling & fixing of Cable Jointing Kit 11 KV 3x185 Sq.mm. Outdoor type
Providing & Fixing/Installation of C Type LT Panel Disconeccting and dismentling of existing C panel and Supply, installation testing commisioning of factory fabricated & wired metal clad dust and vermin proof double door type outdoor application stand mounting, M.S. Channel Base incliding channel stand with bottom cable entreis The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on nonhygroscopic supports such as CMC/BMC support. panel shall be complete with suitable cable end boxes, double compression glands. panel comparment having special provision for internal locking system for stop the electricity theft The panel board shall be fabricated with gelvnized prime sheet with a minimum thickness of 1.6mm/2mm. with seven tank process powder coated. panel haveing proper space for connecting incomming and outgoing cable terminations.
Providing & Laying of HDPE Pipe 160 mm OD PN-4 PE-80 Grade UV Stabilized HDPE as per IS: 4984 of 6 Meter length
Horizontal Drilling underground installation piping HDPE Pipe 160mm dia with minimum depth of pipe 1.2 below surface for double circuit length of line
Laying of 33/11 KV XLPE cable in HDPE Pipe/Trench/Double Pole structure/Loop etc.
Digging of trench by excavation of earth 0.90/1.5 Mtr. deep put brick on both side, filling of sand & brick on cable & earth ramming and dressing properly with complete job for laying 33/11 KV XLPE cable in trench
Laying of U/G LT XLPE Cable 3.5x70/150/240 with complete job
Installation of D.O. Fuse Set of 11 KV
Concreting of Pole (ST 13 Mtr./11 Mtr.) PCC Pole
Removal of old transformer (250KVA) with all connected accessories from existing plinth.
The Construction of new Plinth of Size 5’X5’X4’ above ground level and one ft. below the ground level for 400/250 KVA transformer
Installation of following transformer on Plinth/Double pole with all connecting accessories jumering etc. including carriage of transformers from store centre, Mathura to work site.
400 KVA Transformer on Plinth
250 KVA Transformer on Plinth
100 KVA Transformer on Double Pole structure
Providing and Installation of Tail less unit complete
Construction of M.S angle fencing of size (3M x3M x2M) around the plinth of 400/250 KVA transformer and gap between the M.S angle should not be more than 65mm.
Complete Gel earthingof 11/0.4 KV 250/400 Distribution Transformer by digging pits 6” dia upto 3 mtr. deep including chemical filled pipe in between (pipe-in-pipe) ISI mark B Grade & connecting with G.I strip of size 50mm X 6mm with neutral/body of 11/0.4 KV distribution transformer to above pipe-in-pipe (PIP) and filling of chemical crystalline conductive mixture containing highly conductive material around the (pipe-in-pipe) up to 3 Mtr. including making of chamber at the top of the earthing. Other details are as below:- 1.Earth pipe material – mild steel, Galvanised. 2-Main Electrode diameter – 42.4mm. 3-Auxiliary Electrode pipe, Diameter – 76mm. 4-Wall Thickness of main Electrode :- 2.6mm. 5-Wall thickness of auxiliary Ist whole:- 3.2mm. 6- Length of earthing electrode (PIP):- 3 Meter.
Proper Road Restoration Kaccha/Pakka (After completion of 33 KV & 11 KV Line work)
Dismantling of 01 Nos. 11 KV Damaged VCB with Strurcture (if any), 29 Nos. single support ST/Rail Pole(13/11/9mtr.) with complete accessories and HT Line Conductor from work site to Store Center, Mathura with safe loading and unloading.
M/s G.D. Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .