Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Being Overall Rate Reasonable | |
| 2 | L2₹24.6 L+₹2.5 L (11.5%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹25.1 L+₹3.0 L (13.5%)Rejected-Finance 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹26.3 L+₹4.2 L (19.0%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹27.2 L+₹5.1 L (23.0%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹29.3 L
EMD Value
₹58,580
Closing Date
13 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
PERIODICAL SERVICES AND REPAIRS TO ROOF FLOORS JOINERY WALL INCL MISC REPAIRS TO OTM ACCN AT DUNKRIK LINE UNDER AGE BR P IN GE CENTRAL KIRKEE
2021_MES_469061_1
8489/E8 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹58,580
Yes
11 Oct 2021
18 Aug 2021
14 Sept 2021
18 Aug 2021
13 Sept 2021
1 Sept 2021
18 Aug 2021 - 31 Aug 2021
60 days
Amount
M & L for taking down cement or cement lime plaster of any discription on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L for preparing plastered or unplastered old surface of walls including brooming down or scrapping down with steel wire brushes, smoke soot, moulds, moss efflorescent salts and trading oil and greasy spots and applying one coat of white wash complete all as specified and as directed.
M&L for preparing plastered or unplastered old surface of ceiling including brooming down or scrapping down with steel wire brushes, smoke soot, moulds, moss efflorescent salts and trading oil and greasy spots and applying one coat of white wash complete all as specified and as directed.
M & L for preparation of old decorated plastered or unplastered surfaces of wall and applying two coat cement base paint complete all as specified and as directed.
M & L for preparation of old decorated plasterd or unplastered surfaces of wall and applying one coat cement base paint complete all as specified and directed.
M & L for applying two coat of oil bound destemper on wall after complete removal of existing treatment complete all as specified and as directed.
M & L for one coat of oil bound distemper on old surfaces of wall including preparation of old surfaces complete all as specified and as directed.
M & L for complete removal of existing treatment of wall and applying two coat of of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed.
M & L applying two coats Apex tile guard for roof tiles icluding prepration, brushing and cleaning of old tiles surface by water complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M & L for 75 mm thick, PCC 1:4:8, Type D-2, using 40mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M & L coloured Non Skid Ceramic Tiles of size exceeding 0.11 sqm but not exceeding 0.18 sqm, 7 mm to 8 mm thick (Square or Rectangular) as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
M & L Virified Ceramic tiles combination of light/dark shade double charged/ultra charged 9-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 complete all as specified and as directed.
S&F Vitrified ceramic tiles dark Shade double charged 9-10mm thick on vertical surfaces such as skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete over and including 10 mm thick backing coat in CM (1:4) complete all as specified and as directed.
S&F coloured glazed ceramic tiles dark Shade 9-10mm thick area of each tiles exceeding 0.16 sqm but not exceeding 0.36 sqm in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 complete all as specified and as directed.
M & L coloured Glazed Ceramic Tiles of size 350x 250x 7mm/ 450X 350X 7mm/450x300x7 mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including backing coat of 10mm thick in cement mortar 1:4 complete all as specified and as directed.
M & L for machine polishing with tin oxide for treating the surface of any description, width or girth including cleaning and preparing the surface complete all as specified and as directed.
Demolition of brick work or stone /boulder masonary built in cement mortar including all quions, arches, pillars, compound wall etc complete all as specified and as directed.
M & L Brick work with fly ash modular size bricks straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L rendering 10mm thick in CM 1:6 on brick or concrete wall surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M&L rendering 15 mm thick in cement mortar (1:4) finished even & smooth without using extra cement on fair faces of stone/ brick masonry or concrete surface of wall with WPC ( WPC will be measured seperately) complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of wall care putty complete all as specified and as directed.
M & L preparation of new plasterd or unplastered surfaces of walls and applying two coats of cement base paint including priming plastered and other surfaces with alkali resistant primer complete all as specified and as directed.
M&L preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel paint (Ordinary tint) complete all as specified and as directed.
M&L for preparation of old pained wooden surfaes of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint any tint complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick (below or above ground level) complete all as specified and as directed.
M & L cement concret prepolished chequered tiles 300x300x25 mm thick with grey cement and pigment, set and jointed in neat cement slurry and pointed in colured cement to match the pigments, over and including 20mm thick screed bed or bedding layer in CM 1:6 etc. complete all as specified and as directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigments over & including 25mm sand cushion and 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate of approved design & pattern as approved by GE, complete all as specified and as directed.
M&L Reinforced cement concrete (nominal mix) type B1 1:2:4 using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tanks (Triple layered, cylindrical vertical with closed top) 500ltrs capacity hoisted and fixed in position including Dismantling of water tanks and removing to store complete all as specified and as directed.
Disconnecting existing tanks n exc 500 lit capacity, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve, 20 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to ISI Marked complete all specified and as directed.
S & F in repairs Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed to 20mm dia bore pipe confirming to ISI Marked complete all specified and as directed.
Cutting holes in brick walls built, in cement mortar or cement lime mortar and stone walls built in cement mortar or walls of cement concrete of superfacial area N exc 150 sqcm complete all specified and as directed.
Taking down Chowkat or frames with shutter (without taking off shutters from the frame) exc1.5 sqm but n exc 4 sqm each complete all specified and as directed.
Taking down Chowkat or frame with shutter (without taking off shutters from the frame) / steel windows n.exc 1.5 sqm each complete all specified and as directed.
Taking down shutter of any description exc 1 sqm and n exc 2 sqm each complete all specified and as directed.
S & F 2nd class hardwood 35 mm thick Plain, framed, panelled shutters (two number of panels), with panels with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated supplied and fitted to chowkats complete all as specified and as directed.
M & L two coats of Synthetic Enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F 200 mm long Aluminium anodised barrel tower bolts of extruded sections complete all as specified and as directed.
S & F 100 mm length butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
S & F 150 mm long aluminium anodised Handle, of extruded section fabricated type complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple (Bolt Type) of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Floor door stopper 140mm length of cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specfied and as direcetd.
Resecuring, easing and adjusting of door shutters exc 1 sq. m and n exc 2 sq. m each for easy closing/opening and tightening of hinges or changing the position of hinges, adjustment of tower bolts, sliding bolts with new screws etc. complete all specified and as directed.
Resecuring, easing and adjusting of door shutters n exc 1 sq. m each for fixing of screws adjusting handles, knobs tightening piano hinges incl misc small adjustments complete all specified and as directed.
S & F in repairs Continuous (piano) hinges, mild steel, bright finish or electro galvanised for 30mm width of flaps complete all specified and as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all specified and as directed.
S&F steel ventilators with top hung shutter including hinges, steel peg stay complete all specified and as directed.
M&L for running welding in repairs n exc 6 mm thickness of metal to be welded for fixing hinges work complete all specified and as directed.
S&F aluminium powder coated window sliding type (3 track) with frame size 100x35x1.2mm thick and shutter frame size 39.40x17.70x1.2mm thick with two glass shutter and one wire mesh shutter including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading screws with and including 4mm thick plain float glass and 0.36mm dia apperture 1.4mm stainless steel wire mesh and fittings etc and making good the jambs and painting with paint should match with the existing suface complete all as specified and as directed.
S & F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S & F Anodised aluminium powder coated (Thickness or powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specfied and as direcetd.
S&F in repairs 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
S & F 5.5 Sheet glass exc 0.5 sqm in each plane, ordinary quality and glazing with oil putty in square complete all as specfied and as direcetd.
S & F Mortice lock, vertical type, size 75 mm made up of aluminium (4 lever) complete all as specfied and as direcetd.
S&F Door closer hydraulically regulated (Aluminium die cast body), designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specfied and as directed.
Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 15mm nominal bore, steel tubing, galvanised, medium grade including all fittings with screwed & socket joints and jointing, complete, fixed to walls ceiling or laid in floors complete all as specified and as directed.
S&F 20mm nominal bore, steel tubing, galvanised, medium grade including all fittings with screwed & socket joints and jointing, complete, fixed to walls ceiling or laid in floors complete all as specified and as directed.
S & F in repairs to Bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed.
S & F in repair stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle,15mm bore size screwed both ends for iron pipe or for unions and fittings and fixed complete all as specified and as directed.
S&F in repair 15 mm bore Pillar taps, cast copper alloy fancy type, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repair cast copper alloy chromium plated health faucet with 1000mm PVC flexible pipe for 15 mm bore with fittings complete all as specified and as directed.
S&F in repairs 15mm dia Brass CP wall mixer 3 in 1 for mixing hot and cold water screwed down for iron pipe complete all as specified and as directed.
S&F in repair vitreous china Squatting pan white orissa pattern size 580x440mm with integral foot rests (Excluding flushing cistern & flush pipe) with 100mm dia bore cast iron P trap including lime concrete bedding and making good the disturbed portion to match with the existing surface of floor complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern) EWC white in colour with and incl plastic water seat cover white closed pattern with flat bottom and MS chromium plated hinging device incl connection to outgoing pipe and flushing pipe complete all as specified and as directed.
S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed.
S&F PVC connections 15 mm size with PTMT nut of length 450 mm complete all as specified and as directed.
S&F PVC connections 15 mm size with PTMT nut of length 600 mm complete all as specified and as directed.
S & F in repairs plastic water closet seat cover white/black , closed pattern with flat bottom,and cover & milld steel chromium plated or aluminium hinging device complete all as specified and as directed.
S & F in repair Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet and single side prelam PVC sheet used inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing.
Dismantling of AC sheet in roof covering complete all as specified and as directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets fixed with coach screw in roofs, walls etc. complete all as specified and as directed.
M&L Asbestos cement one piece plain angular ridge 6mm thick Fixed with coach screws complete all as specified and as directed.
Dismantling Mangalore pattern roofing tiles with ceiling tiles or slate roofing including ridge complete all as specified and as directed.
M&L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and as directed.
All as per item No. 81 above but except tiles complete all as specified and as directed.
Disamantling Battens for tiles, shingles etc, of any size including tilting fillets spacing exceeding 15 cm complete all as specified and as directed.
M & L 2nd class hard wood clean sawn battens at 30cm centre section exc15 sq cm but n exc 25 sqcm complete all as specified and as directed.
Dismantling Unframed timber scantlings 40 Sqcm and over in section and in any position complete all as specified and as directed.
M & L for second class hard wood scantlings clean sawn as in unframed work complete all as specified and as directed.
M & L ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
All as per item No. 87 but except ridge or hip tiles complete all as specified and as directed.
M & L Tiles or slate battens, any size and spacing, prepared and treated all over (measured overall on one side only, spaces not deducted) with creosote complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and as directed.
S & F Rolled mild steel in roof trusses (framed), trussed, poles, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) conforming to Fe 410 W(Gde-E-250) quality A including distance pieces, cleats etc. complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
M & L for Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified and as directed.
S & F in repair for false ceiling with 12 mm thick perforated gypsum board granular finish pre painted/plastic coated, fixed on and including GI powdercoated frame work of grid size 0.6x0.6 m consisting of GI angles supports on wall of size 19mmx19mmx0.7mm and cross tee of size 24mmx32mmx0.7mm using purpose made members interlocking into each other and suspended from the roof by using GI hanger wire of dia 2-3 mm of adequate length with adjustable hook clip of 3.5 mm dia wire to be used with main runner etc all as manufacturer's instruction all as per specified and directed. make of GI grid work and ceiling board 'Armstrong or equivalent approved make by accepting officer including dismantling old ceiling board of any description including cover fillets and taking down celing fan and refixing its original position complete all as specified and as directed.
Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M & L for rendering 15 mm thick in cement mortar 1:3 and mixing with WPC 3% by weight of cement complete all as specified and as directed. (WPC paid separately)
M & L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified and as directed.
M & L for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all as specified and as directed.
M & L for PCC 1:5:10 type E2 (using 40 mm graded stone agg) any thick as in sub base of sunken floor complete all as specified and as directed.
Supply only integral water proofing compound (ISI marked) of approved make complete all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
Note for painting items : The following precautionary measures shall be ensured by the contractor during execution of work :- (i) Contractor shall deposit full quantity of materials (Proprietory materials) requried for painting works covered under subject contract in the custody of Engineer-In-Charge/ Office in charge of unit. (ii) The materials as required shall be issued to contractor by JE/ Engineer-In-Charge on daily basis and the empty containers/ bags shall be deposited in the store of Engineer -In-Charge by the contractor, for verification as per standard consumption/ coverage prescribed by the manufacturers.
V.R.PRAJAPATI AND CO.
R k construction
S.R.M.K Enterprises
greenstone construction
M/S JAYCONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .