Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹72.9 LAdmitted-Finance G 16 1 2ND FLOOR SECTOR 15 ROHINI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | -38.99% | ₹72.9 L | L1 | Admitted-Finance |
| 2 | L2₹73.5 LAdmitted-Finance | -38.49% | ₹73.5 L | L2 | Admitted-Finance |
| 3 | L3₹75.3 LAdmitted-Finance | -36.99% | ₹75.3 L | L3 | Admitted-Finance |
| 4 | L4₹79.3 LAdmitted-Finance | -33.62% | ₹79.3 L | L4 | Admitted-Finance |
| 5 | L5₹80.5 LAdmitted-Finance | -32.65% | ₹80.5 L | L5 | Admitted-Finance |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
18 Apr 2026, 3:00 pmClosed
EE,RMD-1,DDA
EE,RMD-1,DDA
Repair and maintenance of Office Complex at DeepaliChowk, Sec-3, Rohini.
2026_DDA_905214_1
01/EE/RMD-1/DDA/2026-27
Open Tender
Civil Works
180 days
Rohini
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹2.4 L
19 May 2026
11 Apr 2026
18 Apr 2026
11 Apr 2026
18 Apr 2026
11 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | ||||||
| 2Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below | ||||||
| 3Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm | ||||||
| 4Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet | ||||||
| 5Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. | ||||||
| 6Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. | ||||||
| 7Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin-charge. | ||||||
| 8Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | ||||||
| 9Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar | ||||||
| 10Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed! roll form G.I. sheet with zinc coating of 120 gms/sgm(both side inclusive), consisting of floor and ceiling channel 50 to mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. a)75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass board Reinforced Gypsum (GRG) plaster conforming to IS: 2095: part 3 (Board with BIS certification marks) | ||||||
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_951460.xls
BOQ • 0.37 MB
NIT01.pdf
Tender Documents • 2.44 MB
Download all tender documents and submit your bid