Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-AOC Accepted lowest bid | |
| 2 | L2₹19.8 L+₹80,422 (4.23%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance Rejected due to highest bid quoted | |
| 3 | L3₹24.4 L+₹5.4 L (28.4%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Rejected due to highest bid quoted | |
| 4 | L4₹26.8 L+₹7.8 L (41.3%)Rejected-Finance H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L4 | Rejected-Finance Rejected due to highest bid quoted | |
| 5 | L5₹30.9 L+₹11.9 L (62.5%)Rejected-Finance | L5 | Rejected-Finance Rejected due to highest bid quoted |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
27 Jun 2023, 6:00 pmClosed
GE (AF) Gurgaon
GE (AF) Gurgaon
REPAIR TO CERTAIN BR WORKS ROOF REPAIRS WELCOME MAINT JOINERIES PLUMBING SANITARY FITTINGS TILLINGS FLOORINGS AND PLASTERING TO BLDG INCLUDING PETTY REPAIRS OF INTERNAL E/M WORKS TO CERTAIN BLDGS IN DOMESTIC AREA AT AF STN ARJANGARH UNDER AGE AF AYA
2023_MES_601402_1
GE/GUR-/NIT-02/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹76,000
14 Jul 2023
6 Jun 2023
29 Jun 2023
6 Jun 2023
27 Jun 2023
20 Jun 2023
Amount
B/R WORKS . Demolition of cement concrete (unreinforced) of any description including cast-in-situ terrazzo (below or above ground level), not exc. 15 cm thickness, including removal of rubbish outside MoD land, complete all as specified and as directed.
Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified and as directed.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing)removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed
Dismentling of brick masonry built in cement mortar as in drain etc., complete all as specified and as directed.
M&L for Brick masonry with sub class B bricks straight or curved on plan exceeding 6m mean radius, built in Cement Mortar (1:4) complete all as specified and as directed.
All as per item No.05 above but except bricks. Note:- Serviceable bricks retrieved from Serial item No. 4 shall be used.
Demolition of stone slabs and tiles of any description or thickness in floors/walls, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
M&L for PCC (1:3:6) Type C-2 50 mm thick using 40 graded stone aggregate as in sub base of floor complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block wilth grey cement and no pigment of any shape and size confirming to IS-15658-2006 of 60 mm thick, M-35 grade over 25 mm thick sand cushioning, etc complete all as specified and as directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates, laid in 1:20 slope as in plinth protection including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/ 25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified and as directed. Note: The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement, complete all as specified and as directed.
M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for 18-20 mm thick machine cut kota stone slab as in flooring, steps of stair(treads), set with neat grey cement slurry @ 3Kg/Sqm, laid over and including 20mm thick cement and sand mortar (1:6) screed bed/bedding layer, jointed with grey cement slurry mixed with pigment to match the sahde of the slab including rubbing and polishingincl dismantl ing damaged stone slab of any description complete all as specified and as directed.
M&L for machine cut kota stone slab 18-20mm thick as in skirting/dado, riser of steps, laid over and including 10mm thick backing coat in CM (1:4), set in neat grey cement slurry @ 3Kg/Sqm, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.
M&L for 18-20mm thick granite ( of any type) work (table rubbed and polished ) in cooking plateform, shelves and the like, over and including 15mm thick screed bed in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed.
S&F Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.11 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed.
S&F , Non skid ceramic coloured joint free tiles, 8 to 10 mm thick (square or rectangular) area of each tile exe 0.18 Sqm but n.exe 0.38 Sqm, laid in floors set and jointed with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed.
All as per item No 18 above but on vertical surfaces such as skirting fixed on and including 10mm thick rendering in cement mortar 1:4 as backing coat complete all as directed by Engr-in-charge.
M & L for coloured glazed ceramic tiles, fixed in pattern of different colour including border of size 300x 450 x 7mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed. Note :- Pattern of the tiles will be decided by GE at the time of execution.
M&L for compiete of newly plastered surfaces as of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer to achieve uniform and smooth surface by roller brush having no sign of brush marks complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces as of ceiling surfaces and applying two coats of white lime wash to achieve uniform and smooth surface complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of cement base paint to achieve uniform and smooth surface having no sign of brush marks complete all as specified and as directed.
Material and labour for preparation of old surfaces of walls by washing rubbing down and stopping of surface and applying one coats of cement base paint complete all as specified and as directed.
M&L for Preparation of old surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc.; rubbing down and stopping of surfaces using sand paper and applying one coat of oil bound distemper, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for preparation of old decorated surface of walls and applying two coat of exterior emulsion (colour matching with existing) paint by roller brush of approved manufacturer complete all as per manufactures instruction and as directed.
Material and labour for removal of existing treatment completely on walls and preparaing the surface for applying two coats of oil bound distemper to achieve uniform and smooth surface by roller brush over and including cement based wall care putty 1mm thick(average thickness) complete all as specified and as directed.
Material and labour for preparation of old painted surfaces of steel of any description and girth, not otherwise described and treated with one coat of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of old painted surfaces of wood and wood based of any description and girth, not otherwise described and treated with one coat of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of old plastered surfaces of walls by washing, rubbing down and stopping of surface and applying two coat of white lime wash complete all as specified and as directed.
Material and labour for preparation of old plastered surfaces of ceiling by washing, rubbing down and stopping of surface and applying two coats of white wash complete all as specified and as directed.
M&L for Providing and injecting chemical emulsion for Post Constructional antitermite treatment along external wall where the apron is not provided along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as spd and as directed.
M&L for Providing and injecting chemical emulsion for Post Constructional antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.
M&L for Providing and injecting chemical emulsion for Post Constructional antitermite treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tank 500 litres capacity, ISI marked triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 20mm bore GI pipe of having weight not less than 210gms including all fittings and gate valves with iron wheel head 20mm size, including taking down existing tank complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tank 1000 litres capacity, ISI marked triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 20mm bore GI pipe of having weight not less than 210gms, including all fittings and 20mm size gate valves with iron wheel head including taking down existing tank complete all as specified and as directed.
S&F PVC tank lid (cover) suitable for 500/1000 litres capacity water tank with hinged and hooked fixing by steel screw for existing PVC water tank on buildings, fixed in repair, complete all as directed by Engineer -in-Charge.
Cleaning and removing all scales and dirt etc by scraping with hard plastic/nylon wire brush and washed with bleaching powder solution and thereafter washed with clean water from service water tank and mouth of circulating pipe of capacity of tank exc. 250 litre but not exc. 500 litre including writing letters “Tank cleaned on_____ (date)” boldly with thick white/black synthetic enamel paint by using stencil with height & width of each letter & figures 150mm & 10mm respectively complete all as specified and as directed .
All as per Ser item No 38 above but capacity of tank exc.500 litre and not exc.1000litre.
S&F in repairs 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) Make Prayag, Polytuff, Skati.
S & F in repair Plastic water closet seat cover,Model Casade any colour, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. Make : Cera 1st quality/Parryware/HSIL.
Supply and fix in repairs chromium plated brass central hole WHB mixer 15 mm bore chromium plated, fancy type including joints to hot and cold complete all as specified and as directed.
Supply and fix in repairs CP brass health faucet of 15mm bore pipe with 1.5 mtr. Flexible pipe screwed for iron pipe fancy type long body complete all as specified and as directed.
S&F in repairs 32/40mm bore and 75cm long PVC waste pipe for WHB/Sink complete all as specified and as directed.
S&F in repairs vitreous china squating pan, 'Orissa' pattern, size 580x440mm white, with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and as directed.
S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and as directed.
S & f in repairs bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified and as directed.
S & F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for 15mm bore iron pipe complete all as specified.
S & F in repairs angle cock/stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15 mm bore iron pipe or for brass ferrule complete all as specified and as directed.
S & F in repairs stop valves, cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type), screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for unions complete all as specified and as directed.
S&F in repairs 15mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed.
S&F in repairs 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Supply and fix in repair Vitreous China wash down water closet constellation white colour or approved equivalent as per specification complete set incl cistern with lid cover as per specification, including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and as directed.
Supply and fix in repair Vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts flushing cistern and flush pipe), including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and as directed.
S&F Plastic water closet seat black/ white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging devices, connected to drains outlet, fixed in repairs, complete all as specified and as directed.
S&F Chromium plated brass shower rose 125 mm sizewith or witout swivel joints including fxing with 15 mm bore pipe, fixed in repairs, complete all as specified and as directed.
S&F in repairs Wash basins, vitreous china, white, flat back of size 550x400mm including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe and including new brackets complete all as specified and as directed.
Taking up or down steel tubing and connections 15mm dia pipes including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel tubing and connections 20mm dia pipes including cleaning for refixing or removal to store complete all as specified and as directed.
S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and as directed. Note : Cutting chases as required shall be measured and paid seperately.
S & F 20mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and as directed. Note : Cutting chases as required shall be measured and paid seperately.
Refixing old serviceable steel tubing and connections 15mm dia in new or old position (walls, ceiling, floors etc) including cleaning properly complete all as specified and as directed.
Refixing old serviceable steel tubing and connections 20mm dia in new or old position (walls, ceiling, floors etc) including cleaning properly complete all as specified and as directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, including removal of rubbish outside MoD land complete all as specified and as directed.
S&F in repairs Internal fitting (siphon) of flushing cistern tank for Vitreous China wash down water closet constellation complete as per sample available in sub division complete all as specified and as directed.
S&F false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid "Armstrong" white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old unservicable false ceilling complete all as per manufacturer’s instructions and as directed.
Dismantling/removing old damaged worn out APP of any thickness incl screed bed or plastering of any thickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete all as specified and as directed.
Material and labour for 15 mm thick cement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 3% by weight of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately.
Material and labour for water proofing treatment of roof consisting as under:- (a) Applying a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of primer @ 0.30 litre/ sq.m including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions complete all as specified and as directed.
All as per Srl item No. 71 here-in-before but on vertical surfaces, using hot blown bitumen having penetration value 30/40 applied 1.20 Kg/ Sq.m over primer @ 0.30 litre/ Sq.m, complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, from chowkhat, complete all as specified and as directed.
S&F Factory made PVC solid door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of 5 mm thick plain colour PVC sheet cut at corner and jointed with 02 Nos., 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided throughout the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical member & minimum 02 Nos. for horizontal member), complete all as specified and as directed.
S & F 35mm thick 2nd class hard wood factory made Glazed and skelton shutters open rebated and prepared to receive glass, gauge etc edges of framing plain chamfered or rounded fitted with cut & mitred beads for securing glass etc size of members shutter as specified in SSR Part I Section 8, Clause 8.23 (a) supplied and fitted to chowkhats, 35mm thick 2nd class hard wood complete all as specified and as directed.
S&F Factory made flush shutters 35 mm thick, ISI marked, solid core construction, with block board core and plywood face panels, commercial type on both faces, complete all as specified and as directed.
S&F Mild steel butt hinges medium weight, cold rolled, 100 mm, ISI marked, complete all as specified and as directed.
S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed.
Supply and fix 100mm size aluminum handle fabricated, 'D' type, anodized ISI marked complete all as specified and as directed.
S&F 300mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed.
M&L for Preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
Dismantling Asbestos cement sheets (corrugated ,semi corrugated etc) in roof coverings incl ridges etc complete all as specified and as directed.
M&L for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
Supply and fixing, drapery rod of mild steel 25mm dia, ribbed/fancy type, PVC powder coated, any shade, including set of fixing brackets, for span not exceeding 2m, fixed to wall in repairs, with PVC finols/finnels, connected accessaries, rubber packing, required screws and PVC rawal plugs as required complete all as specified and as directed.
Supply and fixing, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and directed.
E/M WORKS Taking down carefully copper / aluminium point wiring (light, fan, switch,socket or power, Bell & Two way point) complete with fitting such as switches, sockets, ceiling rose,sketch light fittings etc, and making good the disturbed surface of walls and floors etc as directed.
M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amp socket outlet on independent board.
One 5 Amp socket outlet on same board.
One bell/buzzer point controlled by one bell push
All as per item No-87 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M&L for replacement of point wiring in casing caping/PVC conduit (not less 20 mm) on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including PVC conduit , with mild steel terminal boxes (not less than 1.6 mm thick ) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amp socket outlet on independent board.
One 5 Amp socket outlet on same board.
One bell/buzzer point controlled by one bell push
One light point controlled by two 2-way switch
All as per item No 89 here in befor but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M & L for replacement of point wiring in existing conduit (PVC/Steel) surface / concealed including existing MS Terminal boxes with 1.5 sqmm FRLS PVC insulated multi stranded copper conductor cable single core 1100 volts grade and one run of 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire and laminated sheet cover 3 mm thick on terminal box duly fixed including taking out old u/s wire of any type and size complete all as specified and as directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amp socket outlet on independent board.
One 5 Amp socket outlet on same board.
One bell/buzzer point controlled by one bell push
All as per above item No 91 but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant ( FRLS ) cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps all as specified and directed.
S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. Make : Havells Fabio 2.Carb tree, or its equivalent
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. Make : Havells Fabio 2.Carb tree, or its equivalent
S&F in replacement switch 6 amps modular type one one way complete all as directed.Make : Havells Fabio 2.Carb tree, or its equivalent
S&F in replacement switch 16 amps modular type one one way complete all as directed. Make : Havells Fabio 2.Carb tree, or its equivalent
S&F in replacement electronic fan regulator Step type complete all as specified and directed.
S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and directed.
S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed.
S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed.
S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V complete all as specified and as directed .
S&F in replacement of sheet metal enclosure double door suitable for SPN distribution boards when MCBs to be used having 200Amp rated bus bar 8 ways 240 V complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 10-32 complete all as specified and as directed.
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, all as specified.
S&F in replacement MCB SPN 5 to 40 Amps, 240 volts, curve 'C', breaking capacity 10 KA, all as specified.
S&F in replacement MCB SPN 50 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA, all as specified.
S&F in replacement of 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted.
S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W-2 module ISI Marked complete all as specified as as directed.Make : Havells Fabio 2.Carb tree, or its equivalent
S & F In replacement of Piano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and as directed.
S&F in replacement of modular blanking plate, 1 module ISI Marked complete all as specified and as directed.
S&F in replacement metal flush box 1/2 module all as specified and directed.
S&F in replacement metal flush box 3 module all as specified and directed.
S&F in replacement metal flush box 6 module all as specified and directed.
S&F in replacement metal flush box 8 module all as specified and directed.
S&F in replacement metal flush box 12 module all as specified and directed.
S&F in replacement for white cover plate with frame, 1/2 module all as specified and directed.
S&F in replacement for white cover plate with frame, 3 module all as specified and directed.
S&F in replacement for white cover plate with frame, 6 module all as specified and directed.
S&F in replacement for white cover plate with frame, 8 module all as specified and directed.
S&F in replacement for white cover plate with frame, 12 module all as specified and directed.
S&F in replacement of Hylem sheet 12"x15" complete all as specified and as directed.
S&F in replacement of Hylem sheet 8"x5" complete all as specified and as directed.
S&F in replacement of Hylem sheet 5"x5" complete all as specified and as directed.
Supply and fixing in repair LED post top 40/45 watts complete with suitable size of GI pipe suitable size of required length duly grouted in existing locations including , PVC copper wire 1.5 sq mm 3 core of required lenght (upto 3 mtrs) complete all as specified and directed. Cat No. LLD0001542 of make : HALONIX or Cat No. LPTO-40-CDL-M of Make Crompton equivalent Bajaj
Supply and fixing in repair LED bollard fitting 10w complete with suitable size of nuts/bolts for fixing arrangement and provision of suitable size PCC foundation for fixing of bollard fitting etc complete all as specified and direction by Engr-in-charge. Cat No. LBLSN-10-CDL of Make : Crompton or equivalent in Bajaj and Havells
Taking down electric energy meter of any size and type and deposite to MES store yard complete all as specified and directed.
Supply and fixing in replacement microprocessor based three phase electronic tamper proof energy meter of rating 10 to 40 Amps, AC 415 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed.
Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 60 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed.
Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 40 Amps, AC 240 Volts, 50 Hz covered with toughened glass cover with optical comunication port confirming to IS 13779 complete all as specified and directed.
S & F Wall fan of single phase 230/240 V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed by Engr-In - Charge. Make:Havells or equivalent Make of CG / Bajaj.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified and directed. Make- Havells/halonix/usha/Orient
Supply & fix exhaust fans heavy duty 300 mm dia 1400 RPM, 50 Hz 230 volt for domestic use,dynamically balance blade , epoxy powder coated confirm to IS 2312-1967 with ISI marking IP-55 with class B insulation motor including suitable size louver and all fixing accessories such as fastners nut bolts and electric connection with 3 core cable complete all as specified and directed. Make -Havells/crompton/ bajaj.
Supply and fix in replacement Exhaust fan 380 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , make Havells. / crompton / Bajaj.
Supply and fix in replacement Exhaust fan 450 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , make Havells. / crompton / Bajaj.
Supply and fixing in repair TPN DB's 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and as directed.
All as per item No. 143 above but of 4 way and suitable for housing of 100 A/63 A MCCB as main incoming complete all as specified and as directed.
S & F MCCB 125 Amps capacity, 4 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 8 way TPN DB complete all as specified and as directed.
All as per item No. 145 above but capacity 63 Amps, fixed thermal and magnetic release, 4 Pole, 25 KA suitable to be fixed in 4 way TPN DB complete all as specified and as directed.
Supply and fix in replacement double door TPN DBs 4 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and as directed .
S & F in replacement with MCB TPN 32 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed .
S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed .
S & F in replacement with MCB TPN 100 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed.
S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 36/40 Watts 2'x2' fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including all accessaries all as specified and directed. Wipro/Crompton/Bajaj
Taking down old metallic energy meter box of any size and type complete all as specified and as directed.
S&F in replacement of Energy meter Box Flame retardent polycarbonate body including all fixing arrangement like DIN rails mounting plate connection boxes fastning screw protection plate extra suitable to accomodate 3 Phase energy meter. the meter box shall be of SIze 450x300x214mm with locking arragement complete all as specified and as directed.
All as per Item No 153 Above But to accomodate single phase energy meter of Size 300x300x170mm complete all as specified and as directed.
S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting with pressure die cast aluminium housing ,high efficient LEDs with opal diffuser and IP65 protection all as specified and as directed. Make-: Havells/Bajaj/Halonix
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and as directed. Make:- Crompton/Bajaj/Wipro
S&F in replacement of enviroment friendly indoor decorative 10 Watt LED mirror light polycarbonate Batten with opal diffuser including all accessaries all as specified and as directed. Make : Crompton/Bajaj/Wipro
S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) New conduit/ casing- caping and accessories shall be measured separately. (ii) Two runs of 4.0 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor shall be a unit length.
S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) New conduit/ casing- caping and accessories shall be measured separately. (ii) Two runs of 6.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor shall be a unit length.
S & F in replacement of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G I strip 25x 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 40 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G I wire 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 15 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
Supply and fix ventilating exhaust fan single phase, plastic body 200 mm sweep, complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed.
Supply and fix ventilating exhaust fan single phase, plastic body 250 mm sweep, complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed.
Ish Engineers and Contractors
M/S Rohit Enterprises
PAWAN KUMAR
laxmi enterprises
SHAKSHI ENTERPRISES
Chaudhary Constructions
Shakashi Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .