Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.9 L+₹3.5 L (10.7%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹39.3 L+₹6.8 L (21.1%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹44.3 L+₹11.8 L (36.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
14 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF CERTAIN SANCTIONED WORKS AND MINOR WORKS UNDER GE E/M LUCKNOW
2020_MES_397858_1
GE/EM/LKO/HOSP/T-68 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category a (i), b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹62,000
Yes
2 Feb 2021
24 Nov 2020
16 Jan 2021
24 Nov 2020
14 Jan 2021
2 Jan 2021
60 days
Amount
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level) ,complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep & getting out in soft/loose soil including removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point, complete all as specified and directed by Engineer-in-Charge.
Excavation in post holes (or similar holes) each not exc. 0.5 Cum and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering and removing surplus spoil to a distance not exc. 50 m and making good surface in soft / loose soil , complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces foundation, manholes etc to required levels in soft/loose soil , complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Hardcore of gauge not exceeding 63 mm of broken bricks deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in foundations filling and mass concrete or in sub base to floor, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:2:4), type B-2, using 40 mm graded mechanically crushed stone aggregates as in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:5:10), type E-2, using 40 mm graded mechanically crushed stone aggregates as in sub base 100 mm thick , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete (1:5:10), type E-2, using 40 mm graded mechanically crushed stone aggregates as in sub base 75 mm thick , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in sub base 75 mm thick , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete (1:3:6), type C-2, using 40 mm graded mechanically crushed stone aggregates as in sub base 75 mm thick finished even and smooth without using extra cement , complete all as specified and directed by the Engineer in Charge.
Plain Cement Concrete type B1 1:2:4 (using 20 mm graded stone aggregate) as in roof kerb or padding or similar works or mud stops rounded or chamfered angles and throating including necessary formwork , complete all as specified and directed by the Engineer in Charge.
Plain Cement Concrete type B1 1:2:4 (using 20 mm graded stone aggregate) as in in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete type C1 (1:3:6), using 20 mm graded crushed stone aggregate,70 mm thick , as in path / plinth protection/paving laid in slope in 1:30 in panels n exc 2m long concrete surfaces finished even and smooth without using extra cement including making joints between panel to panel and filling the same with bitumen mastic bitumen & sand mixture in a ratio 1:3 , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete 1:2:4 type B1 , using 20 mm graded crushed stone aggregate, 100 mm thick finishing cement concrete surface even and smooth without using extra cement as in hardstanding/path and the like, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:2:4 type B1 , using 20 mm graded crushed stone aggregate, 75 mm thick finishing cement concrete surface even and smooth without using extra cement as in hardstanding/path and the like, complete all as specified and directed by Engineer-in-Charge.
Forming 20 mm thick Expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound , Grade 'B' complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete type B1 ( 1:2:4) using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills,steps; seismic and other similar band, copings, covings bed plates, and like including weathering slightly rounded or chamfered angles complete all as specified and directed by Engineer-in-Charge.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n.exc 10 cm cm girth in stone concrete block/ slab wall/ concrete floor ,complete all as specified and as directed by Engineer -in-Charge.
Brickwork with Brickwork with Fly ash bricks (bricks shall be burnt clay flyash building bricks as per IS- 13757), straight or curved on plan exceeding 6.0 m mean radius built in cement sand mortar 1:6 ,complete all as specified and as directed by Engineer -in-Charge
Cutting holes into or through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required superficial area N exc 150 sqcm superficial area complete all as specified and directed by the Engineer in Charge.
Reinforced Cement concrete (1:2:4), type B-1,using 20mm graded stone aggregate as in slabs supported on wall beam and column in floor slabs and roofs landing deck slabs and in shelves, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Use & waste of form work to soffits of suspended slab of concrete such as roof slabs, floor slabs, cover slab, shelve, landings and similar works n.exc 200 mm thick (horizontal or sloping); with rough finished surfaces of concrete flat surface, complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to edges of concrete flats, roof exc 5 cm wide and n exc 10 cm wide for rough finished surfaces, complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 10 mm dia and over as in reinforcement cut to length , bent to shape required, including cranking, bending spirally for hooping ends for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia, complete all as specified and directed by the Engineer in Charge.
Steel work in tubular trusses including special shape washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St.240 ,with one shop coat of zink chromote primer paint, complete all as specified and directed by Engineer-in-Charge.
Steel work in tubular trusses (MS tube 80 mm) including special shape washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St.240 ,with one shop coat of zink chromote primer paint, complete all as specified and directed by Engineer-in-Charge.
Steel work in tubular trusses (MS tube 40 mm) including special shape washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St.240 ,with one shop coat of zink chromote primer paint, complete all as specified and directed by Engineer-in-Charge.
Mild steel bolt factory made with hexagonal or square heads at one end and screw the other to be fitted with washer etc and one hexagonal or square length of bolt not exc 5 cm long end dia of neck 11 to 15 mm bolts with nuts and washers , complete all as specified and directed by Engineer-in-Charge.
Rolled mild steel in roof trusses, ( framed), trusses purlins, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee,angle,channel or flat sections ) including distance pieces , cleats etc. Fe-410W (Gde-E- 250) quality- grade A , complete all as specified and directed by Engineer-in-Charge.
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410W (Gde-E- 250) quality- grade A , complete all as specified and directed by Engineer-in-Charge.
Rolled mild steel in rolled sections as in main and cross beams, hip and jack rafters ; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates GDE Fe-410-O OR Fe 310-O grade A ,complete all as specified and directed by Engineer-in-Charge.
M S work as in Hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and countersunk for balusters, nosing to steps including embeding in concrete and securing bolts for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc fillets including all necessary drilling bolting or reveting etc and similar work conforming Fe-290 Gde E-165 ,complete all as specified and directed by Engineer-in- Charge.
M S work as Framed works such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes,framed guard bars barred iron doors ladders, framed balusters walk ways railing, framed work of water tanks, framed and hung as gates including pintle hinges, stops, hand made sliding sliding bolts etc ,cdrilling bolting or reveting etc and similar work conforming Fe-290 Gde E-165 ,complete all as specified and directed by Engineer-in- Charge.
Preparing new steel surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified and directed by Engineer-in-Charge.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering in ridges made to any shape or semi circular cladding to wall, fixed with self tapping screws , complete all as specified and directed by Engineer-in-Charge.
Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws , complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 finished even and fair without using extra cement, complete all as specified and directed by Engineer-in- Charge.
Rendering 15mm thick on fair faces of brick wall or concrete surface in cement mortar 1:4 finished even and fair without using extra cement using in and including integral water proofing compound 2 % by weight of cement, complete all as specified and directed by Engineer-in- Charge.
Rendering 10mm thick on fair faces of brick wall or concrete surface in cement mortar 1:6 finished fair and even without using extra cement ,complete all as specified and directed by Engineer-in- Charge.
Rendering 5 mm thick on ceiling in cement mortar 1:4 finished fair and even without using extra cement ,complete all as specified and directed by Engineer-in- Charge.
Preparing surfaces, plastered or unplastered new surfaces of ceiling and applying three coats white wash all as ,complete all as specified and directed by Engineer-in- Charge.
Preparation of newly plastered surfaces and applying two coats of oil bound disemper over one coat of oil base primer on walls surface over and including a thin layer of wall care putty ,complete all as specified and directed by Engineer-in- Charge.
Preparation of newly plastered or unplastered surfaces of walls by brooming down and priming plastered and other surfaces with and applying two coats of cement base paint over a coat of cement paint primer (before application of cement base paint) ,complete all as specified and directed by Engineer-in- Charge.
Preparation of new wooden surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Complete removal existing treatment and distempering walls with two coats of distemper oil emulsion white or tinted over a coat primer on wall sufaces.Including a thin layer of wall care putty ,complete all as specified and directed by Engineer-in-Charge.
Preparation of old plastered or unplastered surfaces of wallsand applying two coats of exterior emulsion paint over a thin layer of wall care putty on surfaces of any decription over 10 cm width or girth ,complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) & removing & rubbish off the premises , complete all as specified and directed by Engineer-in-Charge.
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in coloured cement to match the shade of tiles, complete all as specified and directed by Engineer-in- Charge.
Demolition of stone slab and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in cement mortar complete all as specified and directed by Engineer-in-Charge.
Granite stone slab ( Black colour) 18-20 mm thick, work (table rubbed and polished and grinding) as in flooring including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed of 15 mm thick in CM 1:6, ,complete all as specified and directed by Engineer-in- Charge.
Machine cut Kota stone slab 20 -25 mm thick (of size not less than 55 cm x 55 cm) laid as in flooring in designer pattern with marble stone with neat cement slurry @ 3.00 kg/Square metre over and including 20 mm thick (average thickness) cement screed (1:4) base, laid and jointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Granite finish) ,complete all as specified and directed by the Engineer in Charge.
Machine cut Kota stone slab 18-20 mm thick as in skirting, over and including 10 mm thick rendering of cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Granite finish) ,complete all as specified and directed by the Engineer in Charge.
Factory made Machine pressed PCC intelocking tiles 60 mm thick M-35 Grade (rubber laminated finish) of shape and size confirming to IS 15658-2006 as approved, laid dry over and including sand not less than 40 mm thick, interstices filled in floors/pathway , laid bedded and pointed in cement mortar ,complete all as specified and directed by the Engineer in Charge.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description not exceeding 1.50 Sq. m each, and making good the disturbed Surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description exceeding 1.50 Sq. m but not exceeding 4.00 Sq. m each, and making good the disturbed surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description not exceeding 1 Sq. m each, from chowkhat, complete all as specified and directed by the Engineer in Charge.
Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, from chowkhat, complete all as specified and directed by the Engineer in Charge.
Plain, solid, straight chowkhats & frames of 2nd class HW wrought, framed rebated on the solid, rounded or chamfered, put together with glue & pinned at joints including preparation of back of chowkhat & treated with coal tar ,complete all as specified and directed by Engineer-in- Charge.
Hold fast, band straps, supports ,Wind ties for stay securing bolts, posts & struts in fencing including cutting cutting tops to shape as directed, drilling holes, notching for wire, etc and similar work conforming to Fe-290 Gde E-165 , complete all as specified and directed by Engineer-in-Charge.
35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with out mitred beads for securing glass etc size of members of door shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkhats , complete all as specified and directed by Engineer-in-Charge.
30 mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including teakwood lipping 6mm thick fixed with nails , complete all as specified and directed by Engineer-in-Charge.
25 mm thick factory made flush shutter (for cup board) solid core construction with block board case & plywood face panels with commercial face on both sides including lipping on edge complete all as specified and as directed by the Engineer-in-Charge
Factory made steel windows with side hung shutter, box type hinges, steel handle 125mm long (fabricated of Z-Section & welded/riveted to shutter in lieu of locking handle), steel peg stay, 2 Nos. tower bolts 100mm on each leaf duly welded, complete with glazing bars, complete all as specified and directed by Engineer -in-charge. Note: Supply & fixing of sheet glass shall be measured and paid separately.
Factory made steel windows with side hung shutter, box type hinges, steel handle 125mm long (fabricated of Z-Section & welded/ riveted to shutter in lieu of locking handle), steel peg stay, 2 Nos. tower bolts 100mm on each leaf duly welded, complete without glazing bars but including MS flat for fixing wire mesh/cloth, complete all as specified and directed by Engineer -in-charge. Note: Supply & fixing of wire mesh/ cloth shall be measured and paid separately.
Aluminium anodised powder coated door shutter double leaf side hung type without sash bar 44.45mm thick (two panels) fabricated with 2mm thick section having vertical and top rail 83.50mm, bottom rail 150mm and middle rail 115mm including jointing cleats, screws, aluminium anodised fittings such as Aluminium anodised handle circular type of 100 mm dia-04 Nos , tower bolts 200mm long 4 Nos for each shutter, Aluminium hinges 100 mm long butt hinges-8Nos , aluminium beading snap type, PVC packing, locking arrangement with mortice lock of best quality, in and including 4.80 mm thick heat absorbing glass pan with necessary beading / packing and necessary fitting & fixtures ,floor Door spring ISI marked steel body , complete all as specified and directed by Engineer -in-Charge.
Aluminium Anodised window, ventilator fixed type shutter, aluminium section weighing 0.55 Kg/m incl necessary joining cleats, glazing clips rubber neoprene packing , Handle 2 Nos in each shutter hinges, anodised aluminium snap beading screw ,complete all as specified and directed by Engineer -in-charge.
Aluminium Anodised window shutter, aluminium section weighing 0.55 Kg/m incl necessary joining cleats, glazing clips rubber neoprene packing , Handle 2 Nos in each shutter, hinges, anodised aluminium snap beading screw , complete all as specified and directed by Engineer -in-charge.
Aluminium Anodised aluminium partition with 12mm thick prelaminated particle board at bottom panel and 5.5.mm thick glass on top panel including glazing clip and neosprene rubber beading , complete all as specified and directed by Engineer -in-charge. Note : Rate of Glass and 12 mm thick prelaminated particle board shall be included in the rate quoted by the contractor against this item.
Aluminium Anodised aluminium partition with 12 mm Thick ACP sheet at bottom panel and 5.5.mm thick glass on top panel incl glazing clip and neosprene rubber beading complete all as specified and directed by Engineer-in-Charge. Note : Rate of Glass and 12 mm thick ACP sheet shall be included in the rate quoted by the contractor against this item.
Double action floor spring hydraulically regu-lated made up of mini-mum 1.25 mm thick aluminium alloy sheet foun-dation box,main body with stainless steel cover, governing pivot made of mild steel heavy duty , complete all as specified and directed by Engineer -in-charge.
Aluminium body ( extruded section ) body Door closer hydraulically regulated, designation No. 3 , universal type , suitable for door shutters 851 to 1000 mm in width and of weight between 61 to 80kg , complete all as specified and directed by Engineer -in-charge.
Mortice lock, 100 mm mild steel verticle type brass 4 Levers complete all as specified and directed by Engineer-in-Charge.
Neosprene rubber beading including taking down old rubber beading as in aluminium window and door shutter , complete all as specified and directed by Engineer-in-Charge.
Butt hinges 100 mm size ,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B11 ,complete all as specified and directed by the Engineer in Charge.
Aluminum anodizes barrel tower bolts of extuded section and fixed of 200 mm long size (length of bolt), complete all as specified and directed by Engineer-in-Charge
Aluminum anodizes barrel tower bolts of extuded section and fixed of 100 mm long size (length of bolt), complete all as specified and directed by Engineer-in-Charge
Aluminium alloy handles of size 125 mm, cast type anodized ,complete all as specified and directed by Engineer-in- Charge.
Aluminum alloy, anodized, sliding door bolt with hasp staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed length of bolt 250mm, bolts not less than 12mm dia with and including a minimum of 6 bolts not,four on bolt plate and two on staple plate complete (ISI marked ) , complete all as specified and directed by Engineer-in-Charge.
Continuous (Piano) hinges, width of flaps (when open ) 30mm, mild steel bright finish or electro galvanised, ISI Marked complete all as specified and directed by Engineer-in-Charge.
Mild steel Double action spring hinge of 150 mm size, with steel wire spring, stove enamelled black, complete all as specified and directed by Engineer-in-Charge.
Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery ,complete all as specified and directed by Engineer-in- Charge.
Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery fixed as in repair,complete all as specified and directed by Engineer-in- Charge.
Sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and directed by Engineer-in- Charge.
Figured glass 3 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and directed by Engineer-in- Charge.
Hacking out old broken glass panes of any thickness, size ,quality or description from wooden frames , glazed with putty or fixed with beads ,complete all as specified and directed by Engineer-in- Charge.
Sheet glass 4.00 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, glazed with putty or fixed with beads ,complete all as specified and directed by Engineer-in- Charge.
Fancy type drapery curtain rod made of mild steel duly PVC sleeved 20 mm dia fixed as in replacment complete all as specified and directed by Engineer-in-Charge.
Powder coated brackets for fixing cutain rods of any dia fixed as in replacment complete all as specified and directed by Engineer-in-Charge.
Steel water tubeing, 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors in and including taking up or down steel water tubing and connections 15mm bore ,complete all as specified and directed by Engineer-in- Charge. Note : Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Steel water tubing, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors in and including taking up or down steel water tubing and connections 20mm bore ,complete all as specified and directed by Engineer-in- Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Steel water tubing, 25 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors in and including taking up or down steel water tubing and connections 25mm bore ,complete all as specified and directed by Engineer-in- Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Bib taps for 15 mm bore pipe, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair, complete all as specified and directed by the Engineer in -Charge
Pillar taps, cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed as in repair, complete all as specified and directed by the Engineer in -Charge
Stop valves, cast copper alloy chromium plated ,screwed down,high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or union fancy type, with long shank and cup (Concealed type) and fixed as in repair, complete all as specified and directed by the Engineer in -Charge
Angle stop cock CP ( Two way) long thread with wall flange , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. fixed as in reapir ,complete all as specified and directed by Engineer-in- Charge.
PVC connection of PTMT ,non corrosive with nuts and washers on both ends,450mm long suitable for 15 mm bore fixed , complete all as specified and directed by the Engineer in -Charge
Vitreous china wash down water closet pan (padestal pattern) with P or S trap white including fixing with bolt in floor with and including 10 litre capacity low level flushingcistern and flush pipe connecting to WC with cistern with and including plastic water closet seat, white closed pattern with flat bottom and cover and mild steel chromium plated hinging device with and including CP spray jet and fixed as in repair , complete all as specified and directed by the Engineer in -Charge
Vitreous China Ware Wash hand basin with pedastal white, flat back, size 550x400mm including cutting for and pinning ends of brackets and fixed on a pair of MS cantilever bracket of appropriate size fixed as in repair, complete all as specified and directed.and fixing .
PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level fixed as in repair, complete all as specified and directed by the Engineer in -Charge
CP brass tubular towel rail 20 mm dia and 600 mm long including brackets fixed as in repair, complete all as specified and directed by the Engineer in Charge.
PVC (SWR) pipes 110mm bore single socketed in any length with ruber rings joints laid in trenches or in floors in and ncluding taking down old pipe including fittings ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 110mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets in and ncluding taking down old pipe including fittings ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 110mm bore junction single, (single Tee) equal or unequal with access door fixed as in repair ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) bends any radius 110mm bore fixed as in repair complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) Vent cowl 110mm bore fixed as in repair ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 75mm bore single socketed in any length with ruber rings joints laid in trenches or in floors in and ncluding taking down old pipe including fittings ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 75 mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets in and ncluding taking down old pipe including fittings ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 75mm bore junction single, (single Tee) equal or unequal with access door fixed as in repair ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) bends any radius 75mm bore fixed as in repair complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) pipes 150mm bore single socketed in any length with ruber rings joints laid in trenches or in floors in and ncluding taking down old pipe including fittings ,complete all as specified and directed by Engineer-in- Charge.
Dismantling PVC water tanks exc 501 ltr but n. exc 1000 ltr capacity by disconnecting existing water connection and removal from site ,complete all as specified and directed by Engineer-in- Charge.
Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve ,complete all as specified and directed by Engineer-in- Charge.
Ball brass valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete , screwed for 20 mm bore dia. pipe or brass ferrule ,complete all as specified and directed by Engineer-in- Charge.
Gun-metal, globe or gate valves 15mm dia , with iron wheel head, screwed both ends for iron pipe and fixed to 15mm dia GI tube ,complete all as specified and directed by Engineer-in- Charge.
Gun-metal, globe or gate valves 20mm dia , with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube ,complete all as specified and directed by Engineer-in- Charge.
Gun-metal, globe or gate valves 20mm dia , with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube fixed as in repair,complete all as specified and directed by Engineer-in- Charge.
Cutting into walls of existing manholes for connecting new drain pipe 150 mm dia bore, making good to wall in CM (1:3)/ PCC (1:2:4) after inserting pipe, cutting out benching & forming branch channel (1/2) round or (3/4 section) in cement concrete (1:2:4) type B-1, reforming benching as required and rendering smooth finished, including removal of rubbish outside MoD land, complete all as specified and directed by the Engineer-in-Charge.
Plain cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by the Engineer-in-Charge.
Salt- glazed stoneware drain pipe grade ‘A’ 150 mm bore, ISI marked jointed with cement mortar, laid in trenches and tested including pipe fittings such as bend, junction etc. of same grade, complete all as specified and directed by the Engineer-in-Charge.
Dismantling of asbestos cement (corrugated, semicorrugated etc) sheets including ridges in roof covering complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by the Engineer-in-Charge
Dismantling of wall and ceiling boards (fiber, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed by the Engineer-in-Charge
2mm thick fibre glass reinforced transclucent corrugated sheeting with two corrugations side lap fixed with L type or J- type or cranked hook bolts and washers in roof, wall etc complete all as specified and as directed by the Engineer-in-Charge
Suspended ceiling, comprising 12.5 mm thick reinforced gypsum plaster boards Conforming to IS-2095 , GI perimeter channels, intermdiate channels, etc. including finishing the exposed surfaces with 1-2 mm thick putty & Oil bound distemper two coats, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminium/Copper conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing complete all as specified.
Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and directed by Engineer-in- Charge.
Point wiring for one socket outlet point 5 amps on independent board controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
All as per item no 134 hereinbefore but one socket outlet point on same baord with other switches with 1.5 sq mm single core multistranded PVC insulated FRLS cable including 1.5 sq mm single core multi stranded copper cable used as continuous earth wire,complete all as specified and as directed by Engineer-in- Charge.
Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
Switch piano flush type , single pole , 5/6 Amps, one way polycarbonate type ,complete all as specified and directed by Engineer-in- Charge.
Switch piano flush type polycarbonate , SP, 16/20 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Socket out let 2 in 1 socket 5 pin polycarbonate , (6 Amps) flush type controlled by one switch complete all as specified and directed.
Socket out let polycarbonate 6 pin, 20 Amps ,complete all as specified and as directed by Engineer-in- Charge.
Ceiling rose, Pilot 3 Plate ceiling rose 6A ,complete all as specified and as directed by Engineer-in- Charge.
Ceiling fan regulator electronic type deluxe 240 Volts ISI Marked as in replacment ,complete all as specified and as directed by Engineer-in- Charge.
Distribution box epoxy powder coated ,SPN 4 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Distribution box epoxy powder coated ,SPN 8 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Distribution box epoxy powder coated ,SPN 12 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps B or C series, 240 Volts to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCBs SPN/ Isolator, 40 Amps, 240 Volts to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Single pole & neutral enclosure box suitable for MCB SP of capicity 6 to 32 Amps B/C type as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Sub main wiring (concealed type ) with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC conduit & 1 run of 4 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring (concealed type ) with two single core 10 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 10Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 10 Sqmm ,1 run of PVC conduit & 1 run of 10 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Flexible copper cable three core 1.50 sqm suitable for connection for electric fititing and fixture as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Recess LED llight fittings of size 2X2 42 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
LED TUBE light fittings with battern of capicity 18 watt (2 feet) ,complete all as specified and as directed by Engineer-in- Charge.
Recess LED llight fittings of 4X1 of 28 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept as in replacement ,complete all as specified and as directed by Engineer-in- Charge.
Mirror light fitting 18 watt make philips Ultron 17-Watt (Cool White, Round) as in replacement, complete all as specified and as directed by Engineer-in- Charge.
Cast AL heavy pole designer leg and broader designer base finisged with stove enemled paint daimeter of one leg is 76 mm and total lenght of the pole inliding base and legs with base plter X04 nos legs a IS 3100 mm (10 Feet 2 inches ) with PCC worksas in replacement, complete all as specified and as directed by Engineer-in- Charge.
Fully cast al with hexagonal junction box max projection breadth of 950 mm sutable for 02 nos post top lanternes for 02 metre and 2.5 metre pole as in replacement, complete all as specified and as directed by Engineer-in- Charge.
Fully cast al with hexagonal junction box max projection breadth of 625 mm sutable for 02 nos post top lanternes for 02 metre and 2.5 metre pole as in replacement, complete all as specified and as directed by Engineer-in- Charge.
Fully cast a body finished with stove enemled paint with acryclic cover total length 915 mm and width 315 mm with b22 brass holder and lamp as in replacement, complete all as specified and as directed by Engineer-in- Charge. MAKE - Mepro , PTL 1500
NEW BHARAT ENGINEERING AND CONSTRUCTION CO
M K Engineers and Contractors
PUMA POWER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .