Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC 422 MAIN BRANCH MASTER TARA SINGH NAGAR JALANDHAR PUNJAB 144001 | JALANDHAR | PUNJAB | 144001 | ₹2.5 Cr | L1 | Accepted-AOC Since found L1 by the Competent Authority |
| 2 | L2₹2.7 Cr+₹15.0 L (5.93%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹2.7 Cr+₹15.0 L (5.93%) | L2 | Rejected-Finance Since not L1 |
| 3 | L3₹2.7 Cr+₹15.8 L (6.27%)Rejected-Finance | ₹2.7 Cr+₹15.8 L (6.27%) | L3 | Rejected-Finance Since not L1 |
| 4 | L4₹2.8 Cr+₹26.2 L (10.4%)Rejected-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | ₹2.8 Cr+₹26.2 L (10.4%) | L4 | Rejected-Finance Since not L1 |
| 5 | L5₹3.2 Cr+₹67.0 L (26.5%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹3.2 Cr+₹67.0 L (26.5%) | L5 | Rejected-Finance Since not L1 |
Tender Value
₹3.2 Cr
EMD Value
₹4.0 L
Closing Date
31 Jul 2020, 6:00 pmClosed
CE(AF) Allahabad
HQ CE(AF) Allahabad
MODERNIZATION OF GTF HANGAR AT PTS AT AF STN AGRA
2020_MES_346515_2
958418/E8
Open Tender
Civil Works
Item Rate
457 days
GE (AF) (Tech Area) Agra
As per NIT and Tender Documents
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) (Tech Area) Agra
₹4.0 L
Yes
11 Sept 2020
17 Jul 2020
6 Aug 2020
17 Jul 2020
31 Jul 2020
18 Jul 2020
Amount
S&F in repair Wire netting (size of mesh 25x25 mm ) of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples etc including re-fixing of existing fillets complete all as specified and directed.
M&L for 20mm thick coloured, anti skid, temperature resistant rubber tile uniform in colour, highly impact resistant of sizes 500x500mm laid with adhesive as per manufacturer instruction etc complete all as specified and directed.
M&L brick work with fly ash brick of old size straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed
M&L cement concrete Type B-1 1:2:4 (20mm graded stone aggregate) in window cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc complete all as specified and directed.
S&F for MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and directed..
M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of aluminium paint over a coat of aluminium red oxide primer complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
S&F MS stairs (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets, etc. Complete all as specified & directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of aluminium paint complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, for unframed work in any position complete all as specified & directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified & directed.
S&F second class hard-wood in scantlings timber wrought complete all as specified & directed.
S&F 2nd class hard wood boarding of 40 mm thick in Floors, Planed one side, with butt joints and fixed with srews complete all as specified & directed .
Preparation of newly wood or wood based surface of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified & directed.
S&F Steel work in railing fabricated with rectangular / Square hollow section, including special shaped, washers etc including cutting welding, bending in shape etc using tube of ST 310 grade conforming to to IS-4923 complete all as specified & directed.
Dismantling of existing roof treatment including tar felt/cement plaster etc from roof surfaces including cleaning the surface and removing the debris from site complete all as specified and directed.
M&L cutting out cracks to V section in existing roof and cleaning grouting with cement and sand slurry 1:3 complete all as specified & directed.
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal shape of groove with cement mortar 1:3 complete all as specified & directed.
M & L for cement concrete 1:2:4 type B1 ( using 20 mm graded stone aggregate) (average 50 mm thickness) in roof for padding to achieve the slope requires etc complete all as specified & directed.
M&L for rendering or bedding layer 15mm thick in CM (1:4) mixed with water proofing compounnd @ 3% by weight of cement or as per manufacturer instrurctioncomplete all as specified and directed. Note :- WPC shall be measured and paid seprately.
M&L cleaning surfaces and applying evently a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/sqm including cleaning surface complete all as specified and directed.
M & L for applying cold bituminous primer @ 0.30 ltr/ Sqm conforming to IS-3384, laying APP polymeric modified membrane 3.5 to 4.00 Kg / Sqm in weight with non woven polyester reinforcement and sealing all the overlap of 100mm in length and 100mm in width of membrane by torching the same as per manufacturer's instructions with gradual finish etc, complete all as specified and as directed.
M&L Preparation of surface of any description, over 10cm in width or girth not otherwise described and applying two coats of aluminium paint over a coat of aluminium red oxide primer over roof treatment complete all as specified & directed.
Taking down cement plaster of any description on brick work or concrete surfaces etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 with WPC and finished the surface even & smooth with out using extra cement complete all as specified and directed.( WPC shall be measured & paid separately)
Supply only Liquid water proofing compound complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finished the surface even & smooth with out using extra cement complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of oncrete surface on ceiling in cm 1:3 and finished the surface even & smooth with out using extra cement complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces of wall including preparation of surfaces, complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces, complete all as specified and directed.
M&L two coats of distemper oil emulsion on newly plastered surfaces over a coat of primer over 3mm thick wall putty on wall including preparation of surfaces, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed.
M&L two coats of white wash on old plastered surfaces of wall including preparation of surfaces, complete all as specified and directed.
M&L for complete removal of existing treatment and apply two coat of distemper oil emulsion over a coat of primer on old decorated surfaces over 3 mm thick wall putty on wall including preparation of surfaces, complete all as specified and directed
M&L one coat of distemper oil emulsion on old distempered surfaces of wall including preparation of surfaces, complete all as specified and directed.
M&L for complete removal of existing old cement base paint surfaces and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed.
M&L for Antitermite treatment in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing surface complete all as specified & directed.
M&L for Antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified & directed.
M&L for Antitermite treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified & directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified & directed.
M&L 18 / 19 mm thick perforated particle board/tiles for insulation and acoustic purposes, 60x60 cm in size, fixed with screws to timber frame work or with staples on snap grid as wall paneling etc complete all as specified and directed
M & L 2 nd class hard wood plain fillets, square, rectangular or triangular in section exc 12 & nexc 25 sq. cm , clean sawn, fixed with screws etc complete all as specified and directed.
M&L 6 mm thick Cover fillets of tempered hard board, 40mm wide and fixing with screws complete all as specified and directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre complete all as specified & directed.
S&F hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed.
S&F 4 mm thick non asbestos fibre cement building board fixed or laid/inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed.
M&L 75 mm thick Cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) as in sub base complete all as specified & directed.
M&L 25 mm thick Cement concrete 1:2:4 type B-0 (12.5 mm graded stone aggregate) as in floor complete all as specified & directed.
M&L coloured light shade Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincl 20 mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed.
Ditto all as above item No 52 but on vertical surfaces such as in skirting incl 10 mm thick plaster in CM (1:3) complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20-25mm thick over and including 20 mm thick screed bed in CM (1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to obtain mirror polish surface complete all as specified and directed.
M&L for machine cut Kota stone as in skirting 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to obtain mirror polish surface incl 15 mm thick plaster in CM (1:3) complete all as specified and directed.
M&L Non Skid coloured ceramic tiles 7 to 8mm thick , area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20 mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed.
M&L glazed ceramic coloured tiles 450x350mmx7mm thick in vertical surfaces such as dado set and jointed in neat cement slurry and pointed in white or colour cement incl 10 mm thick plaster in CM (1:3) complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutter from the frame area exc 1.5 but n. exc 4 Sqm each complete all as specified and directed
All as per item No-58 above but area n.exc 1.50Sqm each.
S&F powder coated anodised aluminium sections of required size for door windows and ventilator frames with one or more rebates including of required size jointing cleats, screws sash fasteners, rollers to move shutters, plug for fixing with walls, columns etc complete all as specified and directed.
S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed.
M&L double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F powder coated anodised aluminium windows and ventilators shutters, side hung type, without sash bars, aluminium sections weighing 0.55 kg /m incl neccessary joining cleats , glazing clips , rubber packing , anodised aluminium snap beading ,screws, rollers and locking assembly, annodised aluminium fiting such as peg stays 150 mm long (1 Nos). hinges type B-21 100 mm long (2 Nos) suitable handle (1 Nos) complete all as specified and directed .
S&F powder coated anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed.
Cutting holes in brick walls exc half brick but n.exc full brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F MS framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Preparation of new steel surface of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
S&F solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in door opening as per specification and drawings.
S&F factory made solid panel PVC door shutter 30mm thick (style ) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded colour plain PVC or channel having a PVC sheet strip of 20mm width stuch in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert top rail & bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frame at site as per specification & drawing.
S&F 100mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-1 complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150mm size complete all as specified & directed.
S&F 150 mm aluminium alloy handle, fabricated type anodised complete all as specified & directed.
M&L for scrapping out loose mortar/ concrete by chiseling/wire brushing complete and applying rust removing solution (rebaklene solution) to exposed corroded reinforcement and applying a coat of epoxy primer (Nitozink primer from M/s Fosrock or equivalent as approved by GE) as per manufacturers instructions providing and fixing of wire mesh of weight 2.5 Kg per Sqm and apply 25 mm average thickness in CM (1:4) mixed with liquid integral water proofing compound ( conplast 'X' recommended by the manufacturer with guniting machine at a pressure not less than 5 Kg/Sq cm finally rendering 10 mm thick plaster in CM 1:4 using liquid integral water proofing compound (Conplast 'X' 421 i.e. from M/s Fosrock and nito bound AR from M/s Fosrock or equivalent as approved by GE) in the proportion recommencded by the manufacturer complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc. (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC 150 mm bore rain water pipe complete all as specified and directed.
S&F Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof for 150 mm bore of pipe complete all as specified and directed.
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wind ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as specified and directed.
Preparation of new steel surface any description, nexc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for 75 mm thick cement concrete as in plinth protection type C-2 ( 1:3:6) using ( 40mm graded stone agg. ) finishing even & smooth without using extra cement complete all as specified and directed..
Taking up or down steel tubing and connection bore of tube in 15mm complete.
-ditto- all as per item No 83 above but 20mm bore.
-ditto- all as per item No 83 above but 25mm bore.
M&L tubes, medium grade galvanized with all fittings and fixed complte to wall and ceilings or laid in floors, bore of tube 15mm complete all as spfd and directed.
-ditto- all as per item No86 above but 20mm bore.
-ditto- all as per item No86 above but 25mm bore.
S&F in repair, bib taps cast copper alloy, cromium plated with crutch or butter fly handle screwed down screwed for iron pipe or for brass ferrule, fancy type bore of pipe 15mm complete all as specified and directed.
S&F in repairs stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union , fancy type chromium plated all as specified and directed and fixed in 15mm bore dia of pipe complete all as specified and directed.
S&F PVC connection 15mm bore and 450mm length with PTMT nuts on both ends fixed in repair complete all as specified and directed.
S&F in repair vitreous china wash basin, flat back size 550x400mm , white complete with waste, chain and plug and porcelain stopper including brackets complete all as specified and directed.
S&F in repair pillar taps, fancy type cast copper alloy capstan heads, chromium plated, screwed down high pressure with or without lettered HOT or COLD with long screwed shank and fly nuts screwed for iron pipe and fixed bore of pipe 15mm complete all as spfd and direrected.
S&F in repair PVC waste pipe 32mm bore, 600mm long complete all as specified and directed.
S&F tubular towel rail 20mm dia 'D' type 60cm long between flanges brass chromium plated complete all as specified and directed.
M&L vitreous china, wash down water closet (pedestal pattern) fixed in repair including seat and cover complete all as spfd and directed.
M&L for PVC (SWR) floor trap plain 75mm dia of outlet with grating including, jointing with solvent cement diameter of outlet 75mm complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as spfd & directed
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends with accessible door any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single(Single T) equal or unequal fixed to wall complete all as spfd & directed
S&F PVC(SWR) vent cowl 110mm dia complete all as specified and directed.
Dismantling PVC water tank and removing from site capacity exc 250 ltrs but n. exc size 500 ltrs complete all as specified and directed.
Disconnecting existing tank setting aside (or lowering if required ) for repairs cleaning and removing all acale and dirt etc from tanks and mouth and circulating pipes etc and reconnecting and refixing in position etc, exc 250 ltr & n. exc 500 ltrs capacity complete all as specified and directed.
All as in item No. 105 above but exc 500 ltr & n. exc 1000 ltrs capacity
S & F for Rotational moulded poleythylene water storage tank 500 ltrs capacity double layered cylindrical vertical with closed top hoisted and fixed in position including fittings all as specified and directed.
S & F for Rotational moulded polyethylene water storage tank 1000 ltrs capacity double layered cylindrical vertical with closed top hoisted and fixed in position including fittings all as specified and directed.
S&F PVC float valve 20mm size with PVC ball and fly nut with aluminium rod complete all as specified and directed.
S&F Gun-metal globe or gate valves, 25mm dia. with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
S&F in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
M&L precast cement concrete of type B-1 1:2:4(20 mm graded stone aggregate ) in landings, cover slabs (for manholes etc.) and similar articles with plain faces including chamfers weatherings, throating etc. and setting in cement mortar(1:4) complete all as specified and directed.
M&L for steel reinforcement of TMT bars (Fe-500 Grade) 10 mm dia and over cut to length and bent to shape required including cranking bending spirally, hooking end and binding with mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips all as specified and directed.
Excavation over area n.exc 1.5m deep and getting out in soft/loose soil all as specified and directed
M&L for PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in filling and footing / mass concrete complete all as specified and directed.
M&L for brick work in cement motar 1:4 using old size fly ash bricks straight or curved on plan exc 6 m mean radius complete all as specified and direted.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including 20 mm thick cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Returning, filling in,soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material of soil exc. 1.50 km but n exc.5 km complete all as specified and directed
Removing demolished/excavated material of concrete exc. 1.50 km but n exc.5 km all as directed
M&L for PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in coping etc complete all as specified and directed..
M&L Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing and as directed.
M&L 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing to wall to make PVC Frame as per specification and drawing and as directed.
Surface excavation n.exc. 30 cm deep and averaging 30cm deep and getting out in soft and loose soil complete all as specified and directed.
M&L hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone complete all as specified and directed.
M&L sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment etc complete all as specified and directed.
M&L cement concrete Type C-1, 1:3:6 (20mm graded stone aggregate) in kerb stone ,copings,, apex stones, , anchorage blocks, , etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc complete all as specified and directed.
Exacavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 sqm on plan and n. exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M& L for cement concrete type C-2, 1: 3: 6 ( using 40 mm graded stone aggregate ) as in foundation, filling and mass oncrete complete all as specified and directed.
Extra for forming fair finished drain or channel 55 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed.
M & L for 10 mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces and fisnished even and smooth complete all as specified and directed.
Excavation over areas exc 1.5m deep and n.exc 3.0 . deep and getting out in soft/loose soil all as specifeid & driected.
M & L for loose filling with aggregate of guage 50 to 100 mm in recharge well all as specified & directed .
M & L for loose filling with aggregate of guage 5 mm to 10mm in recharge well as specified & directed.
M & L for coarse sand/ pea gravel filling in rechagre well as specified & directed. Note:- Pea gravel will be stacked and measured before pouring in pipe.
M&L for steel reinforcement of TMT bars (Fe-500/Fe 500D Grade) 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders cut to length and bent to shape required including cranking bending spirally, hooking end and binding with mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips all as specified and directed.
M & L for Pre-Cast cement concrete 1 : 2 : 4 Type B-1 using 20mm graded stone aggregate for drain cover slab (made 8 to 10 holes of 50 mm dia each cover ) set in CM 1 : 4 including necessary form work complete all as specified & directed.
M & L use and waste form work for soffits and sides of RCC beam all as specified and directed.
M&L for RCC design mix M-25 grade, using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels & similar RCC works all as specified and directed.
Trail bore of 250 dia upto 200 mtr depth below ground level in any kind of soil strat including hard stone/boulder etc all as specifeid & directed.
Reaming upto 525 mm from depth exceeding 60 mtr to 200 mtr including casing pipe of 250 dia and thickness 8mm and pea gravel all as specified & directed.
S & F HDPE pipe 250mm bore of pressure rating 6kgs/cm2 fixed complete all as specified & directed
S & F HDPE perforated pipe 250mm bore of pressure rating 6kgs/cm2 fixed complete all as specified & directed.
S & F HDPE perforated pipe 150mm bore fixed for outelet of water complete all as specified & directed.
Taking down old U/S panel including main switch/MCB/MCCB etc complete all as specified and directed.
Taking down of old U/S cable of size 25 Sq mm all as specified and directed.
Taking down of old U/S cable of size 35 Sq mm all as specified and directed.
Taking down of old U/S cable of size 50 Sq mm all as specified and directed.
Taking down of old U/S cable of size 70 Sq mm all as specified and directed.
Supply, laying, testing of cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor complete all as specified and directed of size- 10 sqmm 4 core
-Ditto- but 16 sqmm 4 core
-Ditto- but 50 sqmm 3.5 core
-Ditto- but 95 sqmm 3.5 core
-Ditto- but 240 sqmm 3.5 core
Removal of excavated soil to a distance not exceeding 50 mtr depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
S&F well burnt sub class 'B' bricks(using old size brick), designation 75 laid in trenches above sand cushioning for cable protection complete all as specified and directed.
M& L Steel tubes, light grade 50mm bore galvanised with all fitting laid in trenches complete all as specified and directed.
M& L Steel tubes, light grade 100mm bore galvanised with all fitting laid in trenches complete all as specified and directed.
M&L for earthing complete with galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 mtr below ground level connected to glavanised iron strip 32 x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl excavation and earth work and disposal of surplus soil incl 40 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PCC (1:3:6) type C-1 using 20mm graded stone aggregate earth pit with, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 12mm dia, plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part-1 (2009) and connected to earth test incl testing complete.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
Supply, Fix & install MCCB with factory made sheet metal enclosure complete all as specified and directed as mentioned below:- a) MCCB 200 Amps, 16KA , 4 pole with thermal magnetic release -01 No b) MCCB sheet steel enclosure 'A' Frame FP - 01 No
Taking down carefully Aluminium/copper/Flame proof point wiring (Light/ Fan/Socket or power) complete incl fitting fixture such as switches, sockets, ceiling rose, brackets, holders, bulk head fitting etc and making good disturbed surface of wall/ceiling etc., all as specified and directed.
Taking down main switch/MCB DB/AC enclosure/Three phase enclosure by disconnecting the electric supply all as directed at site.
Taking down old U/S sub main wiring of aluminium/copper including batten/conduit of 4 Sqmm sizes and making good disturbed surface to match the existing surface complete all as specified and directed.
Ditto- but 6 Sqmm size
Ditto- but 10 Sqmm size
Taking down Ceiling/Exhaust fan, sealing cable end, dismantling blades and removing fan and blades and deposited to AGE E/M store all as specified and directed.
Taking down regulator, sealing cable ends, and removing regulator to AGE E/M store all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed
M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including concealed PVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.2 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of white colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed, for one light/fan/exhaust fan point controlled by one way 5 Amp switch: - Note: Cutting of chase in walls will be measured and paid separately under respective item mentioned here in under.
Ditto- but One 3 pin/5 pin socket out let 5 Amp on independent board
Ditto- but One 3 pin/5 pin socket out let 5 Amp in the same switch of lights/fans.
All as per srl item no. 173 above but with 2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.50 sqmm PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor complete all as specified & directed.
All as per srl item no. 174 above but for 3/6 pin socket outlet for 15 Amps on independent board with 2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.50 sqmm PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor complete all as specified & directed.
M&L for point wiring for hanger light complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including steel conduit ISI marked not less than 20mm dia with including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and conduit fitting, complete with all accessories all as specified and directed, for One hanger light controlled by one MCB SP (Maximum length 35.00 RM) : - Note- (i) The working height for hangar lights is appx 21 m above ground level. cost of scafolding and other T&P shall deemed to be included in the unit rate quoted. No extra charge shall be paid for this purpose.
Ditto- but two hanger light controlled by one MCB SP (length of point wiring(Average length 45.00 RM)
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) FRLS PVC insulated unsheathed cable in and including steel conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.2 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of white colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor FRLS PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and conduit fitting, complete with all accessories all as specified and directed: - For One 3 pin/5 pin socket out let 5 Amp on independent board
M&L for point wiring complete with stranded copper conductor 2.5 Sqmm size (Nominal area) FRLS PVC insulated unsheathed cable in and including steel conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.2 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of white colour fixed with brass screws and cup washer including 2.5 sqmm stranded copper conductor FRLS PVC insulated cable of green colour as earth continuity wire connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed: - For One 3 pin/6 pin socket out let 15/5 Amp on independent board
M&L for point wiring complete with stranded copper conductor 4 Sqmm size (Nominal area) FRLS PVC insulated unsheathed cable in and including concealed PVC conduit ISI marked not less than 25mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.2 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of white colour fixed with brass screws and cup washer including 4 sqmm stranded copper conductor FRLS PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed, for 20 Amps sockets.
S&F switch piano, flush type 5 Amp single pole one way.
S&F socket out let, flush type 5 pin 5 Amp.
S&/F switch piano, flush type 15 Amp .
S&/F socket outlet multi purpose 6 pin 15/5 Amp flush type.
S&F ceiling rose surface poly carbonate body ISI Marked three terminal.
S&F surface/wall mounting LED batten,extruded aluminium housing provided for efficient heat dissipatin with poly carbonate diffuser & intergrated electronic driver including 20 watt LED complete fitting as specified and directed. Model no-ENDURALINEARNEOBS20WLED865SPCWH Make- Havells or Crompton Cat Part No. CCS-100-20-65-HL2-DP-NWH or Bajaj Cat Part No. BCLAB20W.
S&F surface/wall mounting LED batten,extruded aluminium housing provided for efficient heat dissipatin with poly carbonate diffuser & intergrated electronic driver including 10 watt LED complete fitting as specified and directed. Model no-ENDURALINEARNEOBS10WLED865SPCWH Make- Havells/Bajaj BCLSB10WH/ Crompton LCTNL-10WW .
S&F in ceiling recessed/surface mounting 2ft x2ft(600mm x 600mm) LED panel square type, slim, compact, LED edge light panel fitting with opal diffuser and electronic driver complete of size 36 watt. Model no- LCTRN36FOCDL Make- Crompton/ Bajaj Cat No. BZSSQL36WLEDWH/ Cat Part No. VENUSNEOHE2x2 R36WLED 840PIRSENSOR make Havells.
S&F LED complete fitting including 9/10 watt LED tube suitable for mirror light Complete. Make- Crompton Cat No- LDL-10-NW / Havells LUMILINEBS9WLED865SPCWH.
S&F ceiling mounted LED downlighter of clear lighting for extra high ceiling applications fitting with opal diffuser and electronic driver complete of size 70 watt. Model no- CDR-70-CDL Make- Crompton/ Havells SPARKLEROFIXDLR70WLED85760DWHT/ Cat Part No. BCLSB10NW Make:- Bajaj.
S&F LED Highbay LED light of 250 Watt, long life versatile pressure die-cast aluminium IP65 luminarie and fixed on walls/truss all as specified and directed. Model No- LMB-250-CDL/60, Make- Crompton/ Cat Part No. ENDUARPEARLGRANDPLUSSL250WLED757PASYTOTG Make Havells/ Cat Part No. BRTFG 250W LED I Make Bajaj.
Supply and fix LED security light fitting of 72 Watt complete energy saving and environmental friendly & robust roadway luminiare with high power LED of 72 watt LED IP-65 luminiare, including 40mm bore light grade GI pipe bracket 1.5m long, bent to 60 degree and 02x M.S. clamps complete all as specified. Make & Model: Crompton LSTP-72-CDL-M, Bajaj BRTFG72WLEDV3, Havells ENDURACITYLINERNEOSL70WLED757PASYBOTG.
Supply and fix LED FLOOD LIGHT OF 30 WATT COMPLETE WITH ENERGY SAVING, ENVIONMENT FRIENDLY & ROBUST OPEN TYPE VERTICLE Highbay/Mediumbay LED luminiare with IP-65 luminiare, complete all as specified and directed. Cat Part No. JETAQUANTOPLUSFLP30WLED757SYMLENS Make Havells/ Cat Part No SLE FL 30W-COSMO Make: Surya/ Cat Part No. GLOFLO/30W Make C&S.
Supply & fix ceiling fans AC single phase 230/ 240 V of size 1200 mm sweep of 5 star rating complete all as specified & directed. Make-Havells (Model-ES - 50 Premium)/ Crompton HSPlus 48/ Usha Technix.
Supply & fix exhaust fans Heavy duty AC single phase 230/ 240 V of size 300 mm sweep 1400 RPM with louver complete all as specified and directed. Make-Max air in Bajaj/Power flow in Orient/ Aero Clean in Usha/ Austar(Model No:AS165) or equivalent.
S & F, testing complete of HVLS (High volume Low speed) fan, fitted with minimum dia of 16 Ft with 5 nos. blade, motor rating-1.1kW, 70 rpm with all accessories and complete at site all as specified and directed. Make: EPOC FAN/AUSTAR FAN/MGFANS/FALCOE MOTORS
M&L for sub main wiring drawing in and including concealed PVC conduit not less than 32 mm dia medium grade with PVC FRLS cable 16 Sqmm nominal area 4 core 3phase 1 Neutral PVC insulated unsheathed cable with stranded copper conductor incl 16 Sqmm size PVC FRLS cable stranded copper conducter as earth continuity wire and connected to earth dolly complete all as specified & directed.
M&L for sub main wiring drawing in and including concealed PVC conduit not less than 32 mm dia medium grade with PVC FRLS cable 10 Sqmm nominal area 4 core 3phase 1 Neutral PVC FRLS insulated unsheathed cable with stranded copper conductor incl 10 Sqmm size PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly complete all as specified & directed.
M&L for sub main wiring drawing in and including Steel conduit not less than 32mm dia medium grade with PVC FRLS cable 10 Sqmm nominal area 4core PVC 3phase 1 Neutral PVC FRLS insulated unsheathed cable with stranded copper conductor incl 10 Sqmm size PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly complete all as specified & directed.
M&L for sub main wiring drawing in and including concealed PVC conduit not less than 20mm dia medium grade with PVC FRLS cable 6 Sqmm nominal area 2 single core PVC insulated unsheathed cable with stranded copper conductor incl 6 Sqmm size PVC FRLS cable stranded copper conducter as earth continuity wire and connected to earth dolly complete all as specified & directed.
M&L for sub main wiring drawing in and including Steel conduit not less than 25mm dia medium grade with PVC FRLS cable 4 Sqmm nominal area 4core PVC 3phase 1 Neutral PVC FRLS insulated unsheathed cable with stranded copper conductor incl 4 Sqmm size PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly
S&F MCB TPN DB,12 way Vertical type,440V,3 phase with rated busbar 250 Amps, double door type suitable for MCCB as a incomer and MCBs as out going ,IP 54 with metal door ,grouted in walls with cement mortar 1:4 and making good to disturb surface to match with the surrounding, complete all as specified and directed.
S&F MCB TPN DB,8 way Vertical type,440V,3 phase with rated busbar 250 Amps, double door type suitable for MCCB as a incomer and MCBs as out going ,IP 54 with metal door ,grouted in walls with cement mortar 1:4 and making good to disturbed surface to match with the surroundings. complete all as specified and directed.
S&F MCB TPN DB,8 way Vertical type,440V,3 phase with rated busbar 100 Amps, double door type suitable for MCB as a incomer and MCBs as out going ,,IP 43 with acrylic door ,grouted in walls withcement mortar 1:4 and making good to disturbed surface to match with the surroundings. complete all as specified and directed.
S&F MCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 100 Amps, double door type suitable for MCB as a incomer and MCBs as out going ,,IP 43 with acrylic door ,grouted in walls with cement mortar 1:4 and making good to disturbed surface to match with the surroundings. complete all as specified and directed.
M&L for SPN MCB DB of sheet metal enclosure double door type, single pole and neutral 8 way with 200 Amp rated bus bar 240V and grouted in walls with cement mortar 1:4 and making good to disturbed surface to match with the surroundings, complete all as specified and directed.
.S&F sheet metal enclosures with socket plug top and MCB single pole and neutral enclosure with a metal clad two pin and earth plug and socket complete with one single pole 20Amp MCB ,240 volts complete all as specified and as directed.
S & F MCB SP 6 to 32 Amps, 240V 'C' Series 10 KA complete all as specified and as directed.
S & F MCB SPN 32 Amp 240 Volts 'C' series 10 KA complete all as specified and as directed.
S & F MCB TP 32 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
S & F MCB TP 40 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
S & F MCB TP 63 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
S & F MCB TPN 16 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
S & F MCB TPN 32 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
S & F MCB TPN 40 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
S & F MCB TPN 63 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
S & Fixing MCCB with fixed magnetic and fixed thermal relay of 40 Amps 4 pole 16 KA, 415 Volts 50 Hz complete including connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles all as specified and directed.
S & Fixing MCCB with fixed magnetic and adjustable thermal relay of 100 Amps 4 pole 16 KA, 415 Volts 50 Hz complete including connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles all as specified and directed.
M&L for bracing,supports,clamps and back plate fabricated from structural steel, section including nut,bolts,washers,welding, bending cold or hot, drilling holes for bolts, in any shapes or size as indicated or directed and inclusive of one primer coat,one under coat and one finishing coat of aluminium paint.complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc. 10 cm girth on brick walls complete all as specified and directed
Taking down old U/S Air termination rod, point terminal block made of gun metal or phosphorus bronze etc any size complete all as specified and directed.
Taking down old U/S aluminium strip, GI strip etc any size complete all as specified and directed.
Dismantling old earthing system and earth pits and making good the surface complete all as specified and directed.
Supply & fix single pointed air termination Aluminium rod 12mm dia, 300 mm long with all accessories complete all as specified and directed
M & L aluminium strip 25x 3.00mm with sadles FRP/DMC bridge insulators and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed
M & L galvanised iron strip 25x 4mm drawn in Gl pipe and buried in ground complete all as specified and directed .
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw complete all as specified and directed
M & L for GI tubing light grade, 40mm bore for supporting of lightning conductor laid in ceiling/roof or fixed to wall and fixed in vertical position of 1.5 mtr length including fastener, wire 4mm dia for mounting of lightning conductor and Air termination rod complete all as specified and directed.
M&L for 15 mm dia of steel tubes medium grade galvanised with all fittings laid in trenches to walls and ceilings or laid in floors ,complete all as specified and directed.
S&F Bib tap 15mm standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed.
Ditto- but stop cock of bore 15mm
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .