Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC BANK ROAD RAMPURHAT BIRBHUM | RAMPURHAT | BIRBHUM | WEST BENGAL | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹12.3 L+₹2,032 (0.17%)Rejected-AOC BHATTACHARIYA PARA SURI BIRBHUM | SURI | BIRBHUM | WEST BENGAL | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹12.3 L+₹3,414 (0.28%)Rejected-Finance BALLAVPUR BOLPUR BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | L3 | Rejected-Finance Being L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹24,607
Closing Date
19 Nov 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Birbhum Electrical DivisionPWD
Office of the EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P.O. Suri,Dist. Birbhum, Pin 731101
Repairing and renovation work at Main Building and OPD Building of Rampurhat Govt. Medical College and Hospital, Rampurhat in paralleling to health checkup concern of civil wing, PWD.
2024_WBPWD_766038_1
BIRED/116/e-NIQ(1st call) of 2024-2025
Open Tender
ELECTRICAL WORKS ORG
Item Rate
365 days
Rampurhat
Please refer Tender documents.
4 documents required · 4 mandatory
₹24,607
Executive Engineer, Birbhum Electrical DivisionPWD
4 Aug 2025
29 Oct 2024
21 Nov 2024
29 Oct 2024
19 Nov 2024
5 Nov 2024
5 Nov 2024
Amount
Dismantling the Existing wiring after disconnection of all incomming & outgoing line, existing board etc. and kept in departmental store safely.
Dismantaling/unfixing existing single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. unfixing EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and kept in departmental store safely.
Dismantling angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling with dismantling 9W LED lamp (Philips) as to GS. and kept in departmental store safely.
Dismantaling/unfixing existing exhaust fan and kept in departmental store safely.
Dismantaling only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, dismantaling 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting and kept in departmental store safely.
Dismantaling GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. and kept in departmental store safely.
Dismantling of PVC insulated sheathed Al /Armoured/ XLPE various size power cable of 1.1 KV grade on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Polycab/Finolex/RR/Gloster/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make: Legrand Myrus/ Anchor Roma/Crabtree) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr
Supply & Fixing 240 V, 1200 mm, 18/20 W, 110 lm/W single LED light fitting incl. LED Tube light (Fibre Body), suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [Make Havells/ Wipro/Crompton/Bajaj/Philips/Surya]
Supply & Fixing 240 V, 35 W, 920 RPM 375 mm sweep heavy duty AC exhaust fan on 16''x16'' mm thick plywood, after making hole and mending good damages to original finish incl. S & F al. louver shutter as per direction of EIC Make - Orient/EPC/Crompton/Havells)
Supply & Fixing 240 V, 90 W, 100 lm/W only outdoor / street light type fitting complete with all accessories to be fixed / projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [Make Havells/ Wipro/Crompton/Bajaj/Philips/Surya]
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
Supply & Laying of PVC insulated sheathed Al / XLPE Armoured power cable of 1.1 KV grade 4 Core x 10 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ For Compound Flood Light] (Make: Havells/Gloster/RR/KEI)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below (a)4 Core x 10 sq.mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. (a) 4 Core x 10 sq.mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Polycab/Finolex/RR/Gloster/KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. [From Loop Box to Light fittings] 2x2.5sq mm + 1X 1.5 sq.mm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 2x2.5sq mm + 1X 1.5 sq.mm
Earthing Installation – with Pipe Electrode : Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below : By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe.
Earth Busbar Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Earth Continuity Strip Connecting the equipments to earth busbar including S & F 20 mm x 3 mm Galvanised (Hot Dip) MS Flat on wall / floor with GI saddles as required and connection to equipments with incl. drilling holes, bolts, nuts, washers etc.
N.B: i) Payment will be made after availability of fund from concern Department. ii) Payment will be made as per P.W.D norms.
BISWANATH CHATTERJEE (BID ID -5746139)
BINODE ROY (BID ID -5765377)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .