Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹41.8 L Quoted ₹44.4 L | L1 | Accepted-AOC L1 Bid |
| 2 | L2₹52.4 L+₹8.0 L (18.0%)Rejected-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹52.4 L+₹8.0 L (18.0%) | L2 | Rejected-AOC L2 Bid |
| 3 | L3₹55.6 L+₹11.2 L (25.2%)Rejected-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹55.6 L+₹11.2 L (25.2%) | L3 | Rejected-AOC L3 Bid |
| 4 | L4₹59.2 L+₹14.8 L (33.4%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹59.2 L+₹14.8 L (33.4%) | L4 | Rejected-AOC L4 Bid |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
20 Dec 2019, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
REPAIR/REPLACEMENT OF UNSERVICEABLE LT UG CABLE, FEEDER PILLAR BOXES, MCCBS, CHANGE OVER SWITCHES, REPAIR/ REPLACEMENT OF UNSERVICEABLE DO, GOD, SERVICING OF VCBS, TRANSFORMER AND CONNECTED MISC E/M WORKS UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2019_MES_289434_2
GE/BH-39/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹99,000
Yes
21 Jan 2020
29 Nov 2019
23 Dec 2019
29 Nov 2019
20 Dec 2019
6 Dec 2019
Amount
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer all as specified and directed by Engr-in-Charge. Note: for measurement purpose punned thicness of sand only will be considered.
Demolition and taking out old broken bricks any type from the trenches etc.
Supply and laying common burnt bricks of sub class ‘B’ laid flat at right angle on the cable complete all as directed in trenches for cable protection complete all as specified and directed.
Returning filling in including spreading, levilling, watering and well ramming in layers, not exeecding 25 cm thick using excavated soil complete all as specified and directed.
Removing excavated Soil to a distence not exceeding 50 m and deposting where directed at a level not exceeding 1.5 m above the starting point.
M&L in replacement for earth continuity conductor or main earthing strip fixed to wall/ chases or buried in ground or drawn in conduit (pipe/fixed to poles) of any type or any other situation for loop earthing etc with GI strip of size 25 X 4mm complete all as specified by Engr-in-charge.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggrgate for foundation of stay assembly, pole, struts etc all as specified and directed by Engr-in-charge.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggrgate as in pedestal of pole / struts including use and waste of necessary form work and finishing exposed faces of concrete even & smooth without using extra cement complete all as specified and directed.
Supply and fix in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over one coat red oxide primer.
Supply and fix in replacement Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 250 mm x 200 mm size complete all as specified and directed.
Material & labour in replacement for 80 mm dia bore GI steel tubing light grade for protection of cable / earth continuty conductor fixed to poles / walls / roof or laid in floors, road, crossing or ducts fixed with clamps , bolts nuts and wahser etc including taking down old pipe complete all as specified and directed.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:- Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 400 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay XLPE in repair insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 300 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in reapir XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 240 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in reapir XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 185 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 Volt grade of size 120 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 95 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed. Note for item No 4 to 12 :- Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule.
Supply and fix cable jointing kit for 11 KV, earthen grade cable for Outdoor type termination Heat shrink type joint complete with jointing material nut bolt and connection and other connected accessories suitable for 3 Core XLPE armoured aluminimum conductor cable of size 95 Sqmm.
Supply and fix cable jointing kit for 11 KV, earthen grade cable for Indoor type termination Heat shrink type joint complete with jointing material nut bolt and connection and other connected accessories suitable for 3 Core XLPE armoured aluminimum conductor cable of size 95 Sqmm.
Supply & fix in repair cable jointing kit for 11 KV earthen grade cable for straight through Heat shink type joint complete with jointing material & accessories suitable 3 core XLPE armoured Aluminium coductor cable of size 95 Sqmm.
Supply & lay in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt, earthen grade of size 95 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
M&L in repair for Cable jointing Kit for 1.1 KV XLPE insulated cable of size 70 Sqmm 3.5 Core to 120 Sqmm x 3.5 core, outdoor type, straight through, heat shrinkable type with jointing material etc complete all as specified. Make - RAYCHEM / 3M / Denson
M&L in repair for Cable jointing Kit for 1.1 KV XLPE insulated cable of size 25 Sqmm 3.5 core to 50 Sqmm x 3.5 core, outdoor type, straight through, heat shrinkable type with jointing material etc complete all as specified. Make - RAYCHEM / 3M / Denson
M&L in repair for Cable jointing Kit for 1.1 KV XLPE insulated cable of size 185 Sqmm x 3.5 core, outdoor type, straight through, heat shrinkable type with jointing material etc complete all as specified. Make - RAYCHEM / 3M / Denson
M&L in repair for Cable jointing Kit for 1.1 KV XLPE insulated cable of size 240 Sqmm x 3.5 core, outdoor type, straight through, heat shrinkable type with jointing material etc complete all as specified. Make - RAYCHEM / 3M / Denson
Supply and fix in repair On load change over switch of 630 Amp cap 4 pole with MS Encluser made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick channel floor mounted and fixing in ground and necessary mounting accessories all as specified and directed by Engr-in-charge Make :- L & T / C& S / Schinder/ Havells
Supply and fix in repair On load change over switch of 250 Amp cap 4 pole with with MS Encluser made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick channel floor mounted and fixing in ground and necessary mounting accessories all as specified and directed by Engr -in-charge Make :- L & T / C& S / Schinder/ Havells
Supply and fix in repair On load change over switch of 100 Amp cap 4 pole with with MS Encluser made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick channel floor mounted and fixing in ground and necessary mounting accessories all as specified and directed by Engr -in-charge Make :- L & T / C& S / Schinder/ Havells
S&F in repair/replacement MCCB 630 Amp Three pole, 50 KA Adjudtable thermal & fixed magnetic stting ICS 75% of Icu, suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make- Havells:IHLLFCT0630/L&T/Legrand/Schinder Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 630 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make Havells:IHLLNFC0630/L&T/Legrand/Schinder Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 400 Amp Three pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr -in- charge Make Havells:IHLLNFCT0400/L&T/Legrand/Schinder Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 400 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHLLNFCF0400/L&T/Legrand/Schinder Note :- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 250 Amp three pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHLLNFCT0250/L&T/Legrand/Schinder Note :- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 250 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHLLNFCF0250/L&T/Legrand/Schinder Note :- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/ replacement MCCB 200 Amp Three pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHLLNFCT0200/L&T/Legrand/Schinder Note :- (i) Quated rate include the addition/ alteration in busbar system.
S&F in Repair/ replacement MCCB 200 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHLLNFCF0200/L&T/Legrand/Schinder Note :- (i) Quated rate include the addition/ alteration in busbar system
S&F in repair/ replacement MCCB 125 Amp Four pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHLANECF0125/L&T/Legrand/Schinder Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/ replacement MCCB 100 Amp Four pole, 36 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHLANECF0100/L&T/Legrand/Schinder Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 63 Amp four pole, 27 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge Havells:IHA13DBF0063/L&T/Legrand/Schinder Note :-(i) Quated rate include the addition/ alteration in busbar system.
M&L in replacement for HT / LT cable route indicator made out of PCC (1:2:4) type B0 (12.5 mm graded stone aggregate) of size 1000 mm (H) x 120 mm (W) x 80 mm (thick), painted with orange color lettering with synthetic enamel paint and embedded in PCC block (1:3:6) type C2 (using 40mm grade aggregate) of size 150mm x 150mm x 200mm including necessary excavation for PCC block, placed at interval of 30 Metre complete all as directed and Engr-in-Charge.
M&L for removal of bushes by cutting, removing vegetation, garbage, waste materials etc from site making approach way to valve pits, pipelines, FP Boxes and cleaning the surroundings of installations all as specified and directed by Engr-in-Charge.
Finding out the cable fault of any size and any capacity of cable with the help of cable fault locating machine mounting on vehicle and with nessary disconnection of cable from two ends and connection after repairs and having the following items with electrician at site up to lenth of 10 KM cable complete all as specified and directed by Engr-in-Charge. (a) Surge Generator with accessories-01 Nos (b) Head Phone-01 Nos (c) Pin Point Set T-505 with accessories-01 Nos (d) Earthing cable with clamp-01 set (e) Cable fault Locator T-905 with accessories-01 Nos (f) TC-808 with accessories-01 Nos (g) Soldering Iron-01 Nos (h) Soldering wire-01 Nos (j) Plier-01 Nos (k) Soldering paste-01 Nos (l) Capacitor Unit-01 Nos (m) Capacitor connecting cables-01 Nos (n) Power cable-01 Nos (o) Nose Plier-01 Nos (p) Card for SSG-1100-01 Nos
Removing the existing old unserviceable double door LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.15 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 600 amps Aluminium rated bus bar for phases and 600 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C FP 400A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release-01 Nos (ii) I/C FP 320A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release -01 Nos (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB Thermal Magnetic based release for (O/L &S/C) protection with ROH -100A,25 KA -05 Nos (ii)TPN MCCB Thermal Magnetic based release for (O/L &S/C) protection with ROH -63A,25 KA -01 Section -02 Make of MCCBs -ABB/Seimens Schnider/L&T
Removing the existing old unserviceable double door LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.15 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 1000 amps Aluminium rated bus bar for phases and 800 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C FP 630A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release-01 Nos (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -200A,25 KA -03 Nos (ii)TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -160A,25 KA -02 Nos (iii) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -100A,25 KA -05 Nos (iii) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A, 25 KA -02 Nos Make Of MCCBs -ABB/Seimens Schnider/L&T/ Havells
Removing the existing old unserviceable double door LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.5 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 630 amps Aluminium rated bus bar for phases and 400 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C FP 400A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release-01 Nos (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -200A,25 KA -01 Nos (ii)TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -100A,25 KA -05 Nos (iii) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A, 25 KA -02 Nos Make Of MCCBs -ABB/Seimens Schnider/L&T/ Havells
Removing the existing old unserviceable double door LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.15 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 800 amps Aluminium rated bus bar for phases and 800 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C FP 400A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release-01 Nos (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -125A,25 KA -01 Nos (ii)TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -100A,25 KA -04 Nos (iii) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A,25 KA -06 Nos Make Of MCCBs -ABB/Seimens Schnider/ Havells
Removing the existing old unserviceable double door LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.15 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 800 amps Aluminium rated bus bar for phases and 800 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C FP 400A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release-01 Nos (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -100A,25 KA -07 Nos (ii)TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A,25 KA -02 Nos (iii) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A, 25 KA -02 Nos Make Of MCCBs -ABB/Seimens Schnider/L&T/ Havells
Removing the existing old unserviceable LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.15 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 1500 amps Aluminium rated bus bar for phases and 800 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C EDO 1000A, 50 KA ACB Microprocessor Based release for LSIG zprotectionand UVR (ii) TNC Switch (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB Micro processor based release for (O/L &S/C) protection with ROH -630A,50 KA -01 Nos (ii)TPN MCCB Micro processor based release for (O/L &S/C) protection with ROH -400A,50 KA -02 (iii) TPN MCCB Thermal Magnetic Released -100A,25 KA -03 (iv) TPN MCCB Thermal Magnetic Released -63A, 25 KA -02 Make Of MCCBs -ABB/Seimens Schnider/L&T/ Havells
Removing the existing old unserviceable double door LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.15 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 400 amps Aluminium rated bus bar for phases and 160 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C FP 250A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release-01 Nos (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -100A,25 KA -03 Nos (ii)TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A,25 KA -02 Nos (iii) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A, 25 KA -02 Nos Make Of MCCBs -ABB/Seimens Schnider/L&T/ Havells
Removing the existing old unserviceable double door LT panel board and supply, install, testing, commissioning LT outdoor switch gear panel board manufatured by CPRI approved factory, platform mounted, totally enlosed dust and vermin proof with made out of MS angle iron frame of 1800 x 1500 x 450 mm and CRCA sheet of not less than 3.15 mm thick framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long as per IS 5039 cubical type front and rear side openable, provision of air vent and provision of cable alloy with 1000 amps Aluminium rated bus bar for phases and 400 amps rated bus bar for neutral duly painted with powder coated paint of approved shade after seven tank treatement process. The panel shall be suitable for 415 Volts, 50 Hz 3 Phase, 4 wire system and bus bars fixed on porcelain or PVC insulators, thimbles, glands of brass and shall be complete including necessary earth work and PCC foundation complete all as required and directed with following accessories :Make of Panel - Conelec/Universal Switch Gear/Tricolite/Adlec/BBN Energy System (a) I/C FP 630A 36KA MCCB Microprocessor Based release for LSIG protection with ROH , AUX, Trip contact and Shunt release-01 Nos (b) Metering and Indication (i) Digital Multifuction Meter with RS 485 Port, CI -1 (ii) CT for Meter CI -1.0,15VA (iii) RYB phase Indication light (iv) On /off/trip indication light-ACB (v) Control MCB SP (c) Out Goings - (i) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -250A,25 KA -01 Nos (ii)TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -160A,25 KA -02 Nos (iii) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -125A,25 KA -04 Nos (iv) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -100A,25 KA -03 Nos (v) TPN MCCB thermal Magnetic Based release for (O/L &S/C) protection with ROH -63A, 25 KA -02 NosMake Of MCCBs -ABB/Seimens Schnider/L&T/ Havells
Supply & fix testing commisioning Auto main failure ( AMF) panel 15 SWG, 320 KVA DG Set Cubical consist of sheet steel enclosure of 2.00 mm thick totally enclosed dust proof duly painted with powder coated, (shade No. 7032 Siemens gray) fully wired up and ready to connect load & control lines in comprising the followings:- Make- Siemens/ Schnider/ Havells
(a) Under Voltage relay 415V AC for main - 01 No.
b) Under voltage relay 415 V AC for DG – 01 No.
c) AC Timer 230 Volt , 2 No. +2 NC - 01 No.
d) DC Timer 12/24 V - 01 No.
e) Engine Start relay 12/ 24 V- 01 No.
f) Control MCB SP 6 Amp. 230 V – 01 No.
g) Transformer 12 / 24 V – 01 No.
h) Rectifier suitable size – 01 No.
i) LED Indicating Light for Main & DG - 06 Nos.
j) LED Indicating Light for Main & Gen. ON – 02 Nos.
k) LED Indicating Light for battery Charger – 01 No.
n) CT Coil 500 / 5 - 06 Nos.
o) DC Volt Meter 15/30 V - 01 No.
p) DC Amp Meter 0-15 A. - 01 No.
q) Trickle / Boost switch – 01 No.
r) Auto / Manual Switch - 01 No.
s) Start & Stop Push Button - 02 Nos.
t) Frequency Meter – 01 No.
u) Power Contactor MNX 630 A 3 Pole 415V for DG. - 01 No.
v) Power Contactor MNX 630 A 3 Pole 415V for Main. - 01 No.
w) MCCB 630 A 35 KA 3 Pole - 02 Nos.
x) Control Relay - 01 Set.
y) Over Load Relay 2.5-4A. – 01 No.
z) Hooter 24 V DC - 01 No.
aa) C/O Switch 630 A. for bye Pass Main Supply & DG – 02 Nos.
Supply & fix testing commisioning Auto main failure ( AMF) panel 15 SWG, 220 KVA DG Set Cubical consist of sheet steel enclosure of 2.00 mm thick totally enclosed dust proof duly painted with powder coated, ( shade No. 7032 Siemens gray ) fully wired up and ready to connect load & control lines in comprising the followings:- Make- Siemens/ Schnider/ Havells
(a) Under Voltage relay 415V AC for main - 01 No.
b) Under voltage relay 415 V AC for DG – 01 No.
c) AC Timer 230 Volt, 2 No. +2 NC - 01 No.
d) DC Timer 12/24 V - 01 No.
e) Engine Start relay 12/ 24 V - 01 No.
f) Control MCB SP 6 Amp. 230 V – 01 No.
g) Transformer 12 / 24 V – 01 No.
h) Rectifier suitable size – 01 No.
i) LED Indicating Light for Main & DG - 06 Nos.
j) LED Indicating Light for Main & Gen. ON – 02 Nos.
k) LED Indicating Light for battery Charger – 01 No.
n) CT Coil 500 / 5 - 06 Nos.
o) DC Volt Meter 15/30 V - 01 No.
p) DC Amp Meter 0-15 A. - 01 No.
q) Trickle / Boost switch – 01 No.
r) Auto / Manual Switch - 01 No.
s) Start & Stop Push Button - 02 Nos.
t) Frequency Meter – 01 No.
u) Power Contactor MNX 630 A 3 Pole 415V for DG. - 01 No.
v) Power Contactor MNX 630 A 3 Pole 415V for Main.- 01 No.
w) MCCB 630 A 35 KA 3 Pole - 02 Nos.
x) Control Relay - 01 Set.
y) Over Load Relay 2.5-4A. – 01 No.
z) Hooter 24 V DC - 01 No.
aa) C/O Switch 630 A. for bye Pass Main Supply & DG – 02 Nos.
Supply in Repair Aluminium Tube terminals (Lugs) 25 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 35 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 50 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 70 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 95 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 120 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 185 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 240 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 300 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 400 Sqmm
Supply in Repair Aluminium Tube terminals (Lugs) 630 Sqmm
S&F in Reapir Crimping tool Capacity 50 Sqmm to 630 Sqmm portable Jack Type including die 50 Sqmm to 630 sqmm Make Dowells cat No JACK SYT 102 R (HY-282) /janson/Taparia
Vijay Electricals
Shiv Enterprises
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .