Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC C O BIKASH CHAKRABORTY OPPOSITE GITAM NURSERY SCHOOL NEAR BAGHAJATIN PARK PO SILIGURI DISTT DARJEELING WEST BENGAL 734401 | DARJEELING | WEST BENGAL | 734401 | L1 | Accepted-AOC L1 BIdder | |
| 2 | L2₹43.7 L+₹6.2 L (16.4%)Rejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹43.8 L+₹6.3 L (16.7%)Rejected-Finance 9 SARAT BOSE ROAD OPP KALIDHAR TRANSFORMER HAKIMPARA SILIGURI 734 001 | JALPAIGURI | WEST BENGAL | 734001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹44.0 L+₹6.4 L (17.0%)Rejected-Finance ATUL PRASAD SARANI DUDH MORE SILIGURI 06 DARJEELING WB | DARJEELING | WEST BENGAL | 734001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹44.6 L+₹7.0 L (18.7%)Rejected-Finance 45 9 6 BAGHAJATIN COLONY PO PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING WB | 734403 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Dec 2023, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR/MAINT OF SWITCHGEARS, LT PANELS, FEEDER PILLAR BOX, JUNCTION BOX, UG CABLE AND CONNECTED ALLIED WORKS AT ADALPUR POWER HOUSE, DSTV, TARAPUR VIHAR, EME BN, ENGR REGT UNDER AGE E/M OF GE SUKNA.
2023_MES_631139_1
GE Sukna/8627
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
12 Jan 2024
5 Dec 2023
29 Dec 2023
5 Dec 2023
27 Dec 2023
20 Dec 2023
6 Dec 2023 - 27 Dec 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches in any type of soil (soft/loose soil) not exceeding 1.5 metre wide and not exceeding 1.5m in depth LT under ground cables/GI pipes for trenches, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed.
Surface dressing averaging 15 cm deep in soft/ loose soil, including site clearance, cutting of green vegetation, grass, subsequent to above spreading thin layer of anti-vegetation chemical as per the manufacturer instructions (make of chemical shall be as approved by the GE) near the 2/4 pole structures, GODs and various unmanned electric sub stations inside and outside of premises, also including disposal of all spoil, grass, green-vegetation etc outside of the premises, complete all as specified and directed. Note :- The surface dressing shall normally be done once in three months for the Sub-Stations etc as ordered. Payment for each time shall be made for separately as per the actual work done at site.
M&L for sand coushioning to UG cables (8cm deep before laying of cables and 15 cm over the cable) including spreading, levelling, well ramming in layers complete all as specified and directed. NOTE:- punned thickness of 18cm only will be considered for payment purpose.
Boring/Drilling (horizontally) manually under 2m deep in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or broken boulders complete all as specified and directed.
Supply and fix sub class 'B' bricks of standard size for cable protection laid flat across the cable in trenches complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for cement concrete 1:3:6, type C-2 (using 40mm graded stone aggrgate) for pole foundation and copeing including provision of necessary formwork, complete all as specified and directed.
Material and labour for PCC 1:2:4, type B-1 (using 20 mm graded aggregate) as in coping/stay of poles including necessary form work, finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and directed.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe – 290 Gde E -- 165 complete all as specified and directed.
S&F rolled mild steel in plates, gusset plate (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410W (Gde-E-250) quality-A complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 complete all as specified and directed.
S&F steel rolling shutters without ball bearing, with thickness of laths 1.00 mm push and pull or mannual type including top cover, anchoring rod, hasp and staple with one shop coat of red oxide or zinc chrome primer and fixed in position in existing opening complete all as specified & directed.
S&F Safety lever locks mild steel with 4 levers including locking plate for rolling shutter complete all as directed.
S&F Ball bearing of suitable sizes complete for rollong shutter complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M&L coloured glazed ceramic tiles 350x250x7/ 450 x 350 x 7 mm thick as in dado / skirting and vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick screed bed in CM 1:3 complete all as specified and directed.
M&L 10 mm thick double charged premium quality coloured vitrified ceramic tiles (square / rectangular) polished, area of each tiles n. exc. 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20 mm thick screed bed in CM 1:6finish even and rough complete all as specified and directed.
M&L 10 mm thick double charged premium quality coloured vitrified ceramic tiles (square / rectangular) polished, area of each tiles n. exc. 0.36 sqm in skirting/dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick screed bed in CM 1:3 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L 60 mm thick machine pressed precast concrete interlocking coloured paver block of any shape and size confirming to IS 15658-2006, M-35 grade, set with grey cement and pigment, laid over and including 20 mm thick screed bed in CM 1:6 and including demolition complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces / ceiling, racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or stone masonry or on one side of lathing surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M&L for 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces and finished even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick rendering in CM 1:3 on ceiling finished even and fair with using extra cement complete all as specified and directed.
M & L for preparing newly plastered walls surfaces and applying two coats of cement base paint complete all as specified and directed.
M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L preparing of old plastered or un plastered surface of ceilings and applying one coats of oil bound distemper complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of weather coat acrylic exterior emulsion paint over a coat of primer complete all as specified and directed. Note : Rate shall be included for necessary scaffolding and safety arrangement.
M&L preparation of old untreated wall surfaces and inlcuding applying one coat of weather coat acrylic exterior emulsion paint complete all as specified and directed. (Note: rate shall be included for necessary scaffolding and safety arrangement)
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of oil emulsion distemper over a coat of cement primer over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying one coat of oil emulsion distemper complete all as specified and directed.
M&L for preparation of new plastered ceiling surfaces and applying two coat of oil bound distemper over a coat of primer over a thin layer of wall care putty complete all as specified and directed.
M&L for repair to broken/damaged RCC chajjas by making good with PCC 1:2:4 type B1 or rendering 15 mm thick in cement mortar 1:4 mixed with water proofing compound to top and sides and rendering 5 mm thick to soffits in cement mortar 1:3 including necessary form work, reinforcement duly welded if required including demolition of broken/loose PCC or taking down old plaster at any storey of building complete all as specified and as directed. (Note: Rate shall be included for necessary scaffolding and safety arrangement)
M&L preparation of old decorated wall surfaces by brooming down or steel wire brushing scraping down smoke spot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of cement base paints complete all as specified and directed.
M&L preparation of old decorated wall surfaces by brooming down or steel wire brushing scraping down smoke spot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of cement base paints complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparing old plastered surfaces of ceiling and applying one coats of white wash complete all as specified and directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for preparation of old painted wooden based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L preparation of old decorated steel surfaces of any description over 10 cm width or girth when unconnected with other painting or when painted in a different tint and including applying one coat of synthetic enamel paint complete all as specified and directed.
Supply and fixing GI tubing light grade 40 mm dia for protection pipe including taking down old unserviceable ones complete all as specified and directed.
Supply and fixing GI tubing light grade 80 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete including taking out if required complete all as specified and directed.
Taking down of LT cable XLPE insulated UG cable of sizes 10 Sqmm to 150 sqmm size complete all as specified and directed. Note:- Excavation, returning filling, removing paid seperately under relevent item.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 10 sqmm 4 core complete all as specified and directed.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 16 sqmm 4 core complete all as specified and directed.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 25 sqmm 3.5 core complete all as specified and directed.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core complete all as specified and directed.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 70 sqmm 3.5 core complete all as specified and directed.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core complete all as specified and directed.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 120 sqmm 3.5 core complete all as specified and directed.
Supply,laying testing and commissoning of LT cable in repairs XLPE insulated with FRLS loading factor on inner and outer sheath of Extruded PVC and wire armoured electric power cables (hevy duty) with aluminium conductor 1100 volts grade of size 150 sqmm 3.5 core complete all as specified and directed.
Re-routing /re-laying of servicible LT UG cable in trenches with necessary connection and disconnection for re-distribution of load complete all as specified and directed. Note:- Excavation, returning filling, removing, sand, bricks will be measured and paid seperately under relevent items.
S&F in repairs 6 KW, three phase, automatic street light control panel with and including digital timer switch for automatic switching on / off street light as per set time through programmable 24 hour switch, 32A, TP power contactor, 40A SPN MCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd
M&L PVC Insulated Weather proof multicore FRLS PVC sheathed multistranded cables with bright annealed copper conductor of size 1.5 sqmm 3 core for connection of light to pole box completed all as specified and directed.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 600 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 450 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 250 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 250 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge.
Item No. 66.00 contd/.. INCOMING:- (a) MCCB 4 pole 415 volts 25 KA breaking capacity rating 100 Amps Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories - 01 No BUSBAR:- (b) Aluminium busbar suitable for 250 Amp including insulator with nuts & bolts - 04 Nos OUTGOING:- (c) MCCB 4 pole 415 volts 16 KA breaking capacity rating 63 Amps Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories - 01 No (d) Lexic indicator lamp with holder = 03 nos
S&F street light junction box made from CPRI approved factory having size 200 (Width) x 150 (Depth) x 250 (Height) mm (minimum dimensions) made out of 2.00 mm thick CRCA sheet, duly powder coated of approved shade over a coat of red oxide primer both internally and externally, with rain shed all side except back side, comprising of 02 nos copper bus-bar of size 20 x 4 mm mounted on suitable size spacer insulators, necessary cable entry / exit holes for upto 35 sqmm cables, nut-bolts, MS clamps of suitable size for fixing including dismantling complete all as specified and directed. Make - Havells/L&T/Hager/Crompton
S&F in repair LED street light 60 watt made up of pressure die cast luminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥110 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V and including fixing arrangement made out of 40 mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed.
S&F in repair LED street light 90 watt made up of pressure die cast luminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥110 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V and including fixing arrangement made out of 40 mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 100 watt, Tempered protective toughened glass with IP66, IK07, System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including fixing arrangement fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 400 watt, Tempered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥120/135 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including necessary fixing arrangement to fix the fitting with pole and taking down old unsv one complete all as specified and directed.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 500 watt, Tempered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥120/135 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including necessary fixing arrangement to fix the fitting with pole and taking down old unsv one complete all as specified and directed.
S&F 1 x 9/10 watt LED bollard light fitting, IP-65, including 1 metre hot dip galvanized pole, driver, all fixing arrangement etc. including electrically connecting & taking down complete all as specified and directed. Note: 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates.
S&F in repairs 20 watt LED post top lantern, IP-65, die cast aluminium housing, opal diffuser, electronic driver fixing arrangement etc complete all as specified and directed.
S & F Steel Tubular Poles in replacement of old unserviceable RCC Pole complete with and including cast iron base plate , finial taper plug, bolts , nuts & screws, type 410 SP-31(9 Mtr long), also including painting to the external exposed surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer and with 2 coats of black bituminous paint over 1 coat of red oxide primer to the external exposed surfaces of steel poles embedded in the ground / concrete after preparation of the surfaces, numbering to the poles, complete in all respect as specified and as directed. Make: JINDAL STEEL/ NATIONAL TUBING CO/ BOMBAY TUBE & STORE / CALCUTTA POLES & TUBE Note:- 1.Excavation & Earth Work, concrete for foundation and coping shall only be measured and paid for separately. 2. Rate of dismantling old u/s RCC pole deedmed to be included in the quoted rate.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismentaling old unsv ones complete all as specified and as directed by the Engineer-in-Charge.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S&F 4 mm dia GI wire for earth continuity conductor for making connection from earth test point to main DB including taking down old unserviceable ones complete all as specified and directed by Engr-in-Charge
Supply and fixing GI strip 32x6 mm with necessary nut and bolt etc for connection with existing earting pit and electrical equipment complete all as specified and directed.
M&L for roof treatment in order of precedence as given below complete all as specified and as directed:- (i) Taking out of existing water proofing treatment and including padding, cleaning the surface using wire brush, brooming down and washing down with water to remove dust etc, and brushing with neat cement slurry @ 3.00 kg of cement per Sqm. (ii) 15 mm thick screed bed in CM 1:4 on surface. (iii) Cleaning of plastered surface and applying one coat of bituminous primer @ 0.40 Ltr / Sqm. (iv) Supply and laying 3 mm (Minimum) thick APP based polymeric membrane of approved manufacturer with weight not less than 3.60 Kg per Sqm, reinforced with non-woven polyester fabric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (v) Applying one coat of water proofing paint with aluminium finish over APP as per manufacturer's instruction.
Item No. 80.00 contd/.. Note:- (a) Bituminous primer shall be "ShaliTex Primer" manufactured by M/s STP Ltd or equivalent in M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited (b) Laying APP based polymeric membrane shall be done by torch on method as per manufactures instructions. (c) A minimum overlap of 100 mm and 75 mm should be made at the end and sides of the polymeric membrane respectively and all overlaps and joints shall be sealed as per manufacturers instruction. (d) APP based polymeric membrane shall be “SUPER THERMOLAY” manufactured by M/s STP Ltd or “WP Shield” manufactured by M/s Sika India Pvt Ltd or equivalent of M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited (e) Water proofing paint shall be by M/s STP Ltd or M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited
SHRI N.DAS
ASHISH ROY
MS ESSCON
Jagatbandhu Enterprises
PS ENTERPRISE
D K SARKAR
M/S RANEN PAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .