| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-Finance ANDHRA POWER HOUSE DIVISION HPSEBL CHIRGAON 171208 | SHIMLA | HIMACHAL PRADESH | 171208 | ₹2.5 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹2.6 LRejected-Finance VIDYUT BHAWAN HPSEBL SHIMLA 17100 | 17100 | ₹2.6 L | L2 | Rejected-Finance L2 |
| 3 | L3₹2.9 LRejected-Finance VILLAGE ASTANDLI PO DOCHI TEHSIL JUBBAL DISTT SHIMLA H P | JUBBAL | SHIMLA | HIMACHAL PRADESH | ₹2.9 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | RAJESH KUMAR L1 | Mohit Khimta L3 | HANS RAJ L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in foundation, trenches (for pipes & pits) up to all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water,blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, levelling of beds to correct grade i/c shoring/strutting, planking,timbering & dewatering wherever required, stacking the usable & unusable material/soil separaterly & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 Cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of diversion for traffic,night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer - in - charge. | 305.1 | Cum | 470 ₹1.4 L | 550 ₹1.7 L | 500 ₹1.5 L |
| 2.00Laying, butt welding and testing of ISI marked steel tubes plain ended in trenches of following dia as per IS 1239-2001, including jointing the pipes with butt welding at both the ends according to relevant BIS standards/approved specifications including manufacturing reducers/tapers, all short pices and bends as per site requirement and made from parent tubes ( to be measurer and paid alongwith pipes. Bends shall be manufactured in such a way that not more than 111/4 degree deflection is caused by a single cut and internal dia is not reduced including hydraulic testing to the entire satisfaction of Engineer-in-charge. The damaged portion of galvanization due welding shall be provided with anticorrosive treatment by providing two coats of bituminous paint over priming coat as per AWWA specification C-203-1978. (Earth work to be measure & paid for separately). | ||||||
| 2.01 | 65mm dia | 90 | Rmt. | 100 ₹9,000 | 130 ₹11,700 | 110 ₹9,900 |
| 2.02 | 40mm dia | 90 | Rmt. | 75 ₹6,750 | 110 ₹9,900 | 90 ₹8,100 |
| 2.03 | 50mm dia | 120 | Rmt. | 90 ₹10,800 | 120 ₹14,400 | 100 ₹12,000 |
| 3.00 | Fabrication/ Making outlet/ distribution junction i/e all required fitting / Ficing as per drawing i/e reducer, wheel valve, nipples, plug, socket, union etc. all are of generally 32mm to 25mm dia and welding wherever required | 4 | Nos. | 8,500 ₹34,000 | 9,000 ₹36,000 | 8,800 ₹35,200 |
| 4.00Butt welding as per relevent BIS specification (Leak proof) including cost of carriage of welding set, bends tail price, tees reducers increasers as per site requirements and as per the sirection of Engineer in Charge. Earth work in trenches to be measured and paid separately including all leads and lifts and carriage of material at site. (already laid pipes) | ||||||
| 4.01 | 80mm dia | 25 | Joints | 460 ₹11,500 | 490 ₹12,250 | 470 ₹11,750 |
| 4.02 | 65mm dia | 16 | Joints | 400 ₹6,400 | 400 ₹6,400 | 420 ₹6,720 |
| 4.03 | 50mm dia | 18 | Joints | 315 ₹5,670 | 300 ₹5,400 | 320 ₹5,760 |
Tender Value
₹3.0 L
EMD Value
₹6,000
Closing Date
27 Mar 2026, 11:00 amClosed
Executive Engineer
JSV Division Jubbal
Restoration of rain damages of LIS Sawrawin Khatal in GP Rawin and Thana Tehsil Jubbal Distt Shimla HP SH Butt Welding various Dia And Linking of Ghensta and Bharot tanks and construction of Katcha kulh and distribution junctions
2026_HPIPH_131974_15
JBL-SML-09-718
Open Tender
Civil Works
30 days
Saraswatinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹350
₹6,000
16 Apr 2026
19 Mar 2026
27 Mar 2026
19 Mar 2026
27 Mar 2026
19 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Excavation in foundation, trenches (for pipes & pits) up to all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water,blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, levelling of beds to correct grade i/c shoring/strutting, planking,timbering & dewatering wherever required, stacking the usable & unusable material/soil separaterly & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 Cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of diversion for traffic,night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer - in - charge. | - | Cum | - | - | |
Laying, butt welding and testing of ISI marked steel tubes plain ended in trenches of following dia as per IS 1239-2001, including jointing the pipes with butt welding at both the ends according to relevant BIS standards/approved specifications including manufacturing reducers/tapers, all short pices and bends as per site requirement and made from parent tubes ( to be measurer and paid alongwith pipes. Bends shall be manufactured in such a way that not more than 111/4 degree deflection is caused by a single cut and internal dia is not reduced including hydraulic testing to the entire satisfaction of Engineer-in-charge. The damaged portion of galvanization due welding shall be provided with anticorrosive treatment by providing two coats of bituminous paint over priming coat as per AWWA specification C-203-1978. (Earth work to be measure & paid for separately). | - | - | - | - | |
65mm dia | - | Rmt. | - | - | |
40mm dia | - | Rmt. | - | - | |
50mm dia | - | Rmt. | - | - | |
Fabrication/ Making outlet/ distribution junction i/e all required fitting / Ficing as per drawing i/e reducer, wheel valve, nipples, plug, socket, union etc. all are of generally 32mm to 25mm dia and welding wherever required | - | Nos. | - | - | |
Butt welding as per relevent BIS specification (Leak proof) including cost of carriage of welding set, bends tail price, tees reducers increasers as per site requirements and as per the sirection of Engineer in Charge. Earth work in trenches to be measured and paid separately including all leads and lifts and carriage of material at site. (already laid pipes) | - | - | - | - | |
80mm dia | - | Joints | - | - | |
65mm dia | - | Joints | - | - | |
50mm dia | - | Joints | - | - |
stage.html
html • 0.04 MB
technical_195196.pdf
techsummary_195196.pdf
finance_195196.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.58 MB
BOQ_195196.xls
BOQ • 0.35 MB
f6.pdf
Tender Documents • 0.16 MB
f8.pdf
Tender Documents • 0.70 MB
tc.pdf
Tender Documents • 0.31 MB
Download all tender documents and submit your bid