Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.8 LAdmitted-Finance | +22.95% | ₹7.8 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | - | Rejected-Technical DUE TO NOT UPLOADED SHORT FALL DOCUMENT |
Updated dates
Tender Value
₹7.4 L
EMD Value
₹14,889
Closing Date
6 Apr 2026, 6:00 pmClosed
SE (T AND C) RVPN AJMER
SE (T AND C) RVPN, SHASTRI NAGAR, AJMER
Old Painted Steel Structures, Power Transformers and equipment painting work at 220kV GSS, Beawar
2026_RRVPN_546175_1
RVPN/SE/TNC/AJM/ BN 1110002516
Open Tender
Electrical and Maintenance Works
90 days
BEAWAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
AO (T AND C) RVPN AJMER
₹14,889
Yes
SE (T AND C) RVPN AJMER
6 May 2026
14 Mar 2026
7 Apr 2026
14 Mar 2026
6 Apr 2026
14 Mar 2026
23 Mar 2026
PAINTING OF STRUCTURE & EQUIPMENTS PAINTING OF OLD PAINTED STEEL STRUCTURES:- Aluminium painting of old painted steel structure at the GSS including supply of paint and painting brush, emery paper, cloth & solvents etc. The surface shall be first cleaned with wire brush/emery paper and thereafter wiped with cloth to remove rust and dust or any other deposits on erected M.S. steel structures. Two coat of aluminium paint shall be applied. Each subsequent coat shall be applied only after the previous coat has dried up. The paints used shall be from any of the following recognized manufacturers, namely Asian/Nerolac/ Berger/Johnson Nicholson
PAINTING OF TRANSFORMERS & EQUIPMENTS:- Enamel painting on power transformer and other equipments including supply of paints and spray painting set, emery paper, cloth & solvents etc. The surface shall be cleaned thoroughly with soda/ caustic solution to clean oily surface and thereafter washing with water. Thereafter two coats of smoke gray synthetic enamel paint shall be applied by spray method. Each subsequent coat shall be applied only after the previous coat has dried up. The paints used shall be from any of the following recognized manufacturers, namely Asian/Nerolac/Berger/Johnson Nicholson. In case of surface area of radiators, those fins will only be considered which are actually feasible and approachable for painting by spray or by brush.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.23 MB
BOQ_973925.xls
BOQ • 0.27 MB
1110002516.pdf
Tender Documents • 16.10 MB
Download all tender documents and submit your bid