Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹1.1 Cr | L1 | Accepted-AOC Bidder fulfills the requisite criteria and being lowest |
| 2 | L2₹1.1 Cr+₹3.4 L (3.12%)Rejected-Finance | ₹1.1 Cr+₹3.4 L (3.12%) | L2 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest |
| 3 | L3₹1.2 Cr+₹5.9 L (5.34%)Rejected-Finance | ₹1.2 Cr+₹5.9 L (5.34%) | L3 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest |
| 4 | L4₹1.2 Cr+₹5.9 L (5.36%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹1.2 Cr+₹5.9 L (5.36%) | L4 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest |
| 5 | L5₹1.2 Cr+₹6.0 L (5.46%)Rejected-Finance H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | ₹1.2 Cr+₹6.0 L (5.46%) | L5 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
22 Feb 2023, 6:00 pmClosed
CWE AF BIKANER
HQ CWE AF BIKANER
WORK SERVICES FOR INTEGRATION OF COMMERCIAL POWER SUPPLY TO MPR AT AF STN BIKANER
2022_MES_556011_3
81501/E8
Open Tender
Civil Works
Lump-sum
270 days
GE AF NAL
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE AF NAL
₹2.0 L
Yes
27 Mar 2023
8 Feb 2023
24 Feb 2023
8 Feb 2023
22 Feb 2023
15 Feb 2023
8 Feb 2023 - 13 Feb 2023
Amount
Schedule 'A' Part-I (BUILDING WORK)
Construction of building ( One room for isolation transformer and two rooms for UPS and battery bank each) at AF Stn Bikaner complete all as specified and as shown on drawing.
Schedule 'A' Part-II (EXCAVATION/ EARTHWORK/ SITE CLEARANCE AND DEVELOPMENT )
Lump sum price worked out by contractor for "Excavation/ Earthwork/ Site Clearance and Development ” as listed in Schedule ‘A’ Part- II.
Schedule 'A' Part - III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by contractor for "INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part- III.
Schedule 'A' Part- IV (AIR CONDITIONING)
Lump sum price worked out by contractor for "AIR CONDITIONING" as listed in Schedule 'A' Part- IV.
Schedule 'A' Part- V (ROAD/ PATH AND HARDSTANDING)
Lump sum price worked out by contractor for "ROAD/ PATH AND HARDSTANDING " as listed in Schedule 'A' Part- V.
Schedule 'A' Part- VI (EXTERNAL ELECTRIC SUPPLY)
Lump sum price worked out by contractor for " EXTERNAL ELECTRIC SUPPLY " as listed in Schedule 'A' Part- VI.
Schedule 'A' Part-VII (LIGHTENING PROTECTION)
Lump sum price worked out by contractor for "LIGHTENING PROTECTION " as listed in Schedule 'A' Part-VII.
Schedule 'A' Part -VIII (MISCELLANEOUS ITEMS)
Supply and Fixing IP20 linear LED T8 tubular lamp with extruded Aluminium PC body and PC diffuser complete with inbuilt driver in replacement of unserviceable conventional FTL 36/40 W to be fixed in existing batten including all electrical connections with 1.5 sqm single core cable complete all as specified and as directed. Make: - CG/Havells/L&T
Supply and Fixing new decorative box type fitting 16/20 watt pre-wired for LED tube with blue coloured end caps complete all as specified and as directed. Make: - CG/Havells/L&T
Material and Labour for sub main wiring complete with 2.0 sqmm 4 core copper conductor cable PVC insulated multi-stranded and unsheathed LT 1100 volts grade drawn through and including PVC conduit 25 mm dia 2.00 mm thick ISI marked fixed on wall/floor etc with accessories duly connected with earth dolly complete all as specified and as directed.
Supply and fixing voltage stabliser for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130 Volts to 280 Volts with output voltage stablized at 230 Volts with accuracy of ± 2.5 of capacity 5 KVA complete all as specified and as directed.
Supply and Fixing as in repairs MCB distribution board Double door SPN 230 volts 6 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc including taking down old unserviceable one complete all as specified and as directed. Make: - Hager/ Legrand/ Schneider/ L&T.
Material and Labour for sub main wiring complete with 6.0 sqmm 4 core copper conductor cable PVC insulated multistranded and unsheathed LT 1100 volts grade drawn through and including PVC conduit 25 mm dia 2.00 mm thick ISI marked fixed on wall/floor etc with accessories duly connected with earth dolly complete all as specified and as directed.
Material and Labour for sub main wiring complete with 4.0 sqmm 4 core copper conductor cable PVC insulated multistranded and unsheathed LT 1100 volts grade drawn through and including PVC conduit 25 mm dia 2.00 mm thick ISI marked fixed on wall/floor etc with accessories duly connected with earth dolly complete all as specified and as directed.
Supply and install isolation transformer 400 KVA, 415/415 V (Fixed Ratio), 3 phase, 50 hz, ONAN cooled oil immersed double copper wound indoor type isolation transformer complete with first filling of IS: 335 ISI marked filtered and dehydrated transformer oil electrostatic shield between primary and secondary winding and other standard fittings / accessories delta on 415 Volts side and star on 415 Volts with vector group dyn-II all as specified and directed.
Supply, laying and testing XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade size single core 630 sqmm including necessary thimble complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing unarmoured copper power cable solid copper conductor, XLPE insulated, cores laid up, PVC inner sheathed of size 1 core 185 sqmm including necessary thimble complete all as specified and as directed by Engr-in-Charge.
Supply, laying and testing unarmoured copper power cable solid copper conductor, XLPE insulated, cores laid up, PVC innersheathed of size 1 core 35 sqmm multi strands (colour green over yellow) including necessary thimble complete all as specified and as directed by Engr-in-Charge.
Supply, laying and testing unarmoured copper power cable solid copper conductor, XLPE insulated, cores laid up, PVC innersheathed of size 4 core 2.5 sqmm including necessary thimble complete all as specified and as directed by Engr-in-Charge.
Supply, installing, testing and commissioning factory made LT feeder pillar box indoor type platform mounted, suitable for 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D-2 with 40mm crushed stone aggregate 20cm thick in foundation and of height upto 0.5 mtr all as directed at site. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following. Note: - Following fitments shall deemed to be included in the cost of panel: - INCOMING:- (a) ACB 800 A 4 pole with microprocessor based release draw out manual type ,safety shutter(O/L,S/C,E/F Protection and metering display) operated upto temp 65 deg Celsius-01 Nos (b) Alarm/hooter for commercial trip with ON/OFF Facility- 01 No. (c) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (d) Digital Voltmeter & Ammeter with necessary CT's. (e) Phase indicating lamps (R-Y-B) - 01 set. OUTGOING: - (a) MCCB 4 pole 630 A with adjustable thermal and magnetic setting breaking capacity 50 kA-01 No. (For Radar) (b) MCCB 4 pole 63 Amp with adjustable thermal and magnetic setting breaking capacity 25kA- 01( For UPS Room) (c) MCCB 4 pole 40 Amp with adjustable thermal and magnetic setting breaking capacity 16 kA-04 Nos( For Sub Stn and Street light and 02 spare) (d )SPD class I three phase suitable for 630amps, 440V and impulse current 25 K Amps per pole
Supply and fixing 45 W LED based street light luminaries new generation energy saving and environment friendly light fitting high power LEDs as light sources. LED luminous efficiency should be > 80Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver). Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission). It shall have epoxy powder coated grey finish phosphochromate treatment, IP-66 protection class-I operating voltage range should be from 120 volt to 270 Volt AC and frequency range 50Hz. Fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5 sqmm with OH line or PVC junction box complete all as specified and as directed.
Supply and fixing alarm unit for commercial/UPS failure complete all as specified and as directed.
Supply and fixing on load changeover switch 415V in sheet metal enclosure 4 pole of capacity 400 Amps complete all as specified and as directed.
Material and labour for Copper round block size 25mm dia X 50mm long having outside thread at one end to be fixed on the top of GI Socket and inner thread 12 mm for Air termination, suitable arrangment for fixing the copper strip complete all as specified and as directed by Engr-in-charge.
Supply and fixing wireless addressable smoke detector with battery, testing button, LED and all mounting accessories for fixing complete all as specified and as directed by Engr-in-charge.
Supply and fixing for wireless addressable electronic hooter with inbuilt transmitter cum red flasher with sounder and red ABS plastic enclousure, with back up facility in case of power failure complete all as specified and directed by Engr-in-charge.
Supply and fixing for wireless intellegent addressable manual call point (MCP), break glass type with hammer complete all as specified and as directed by Engr-in-charge.
Supply and fixing for wireless addressable main control panel with display and alarming sound with back up facility in case of power failure complete all as specified and directed by Engr-in-charge.
Supply, Install, testing and commisioning 300 KVA UPS designed with IGBT based rectifier, three level technology together with DSP control arithmetic along with high input power factor, low THDI and high system efficiency and with inbuilt protection against harmonics for 30 minutes back up three phase AC input 300V to 450V and output 415V +- 1% including 80 Nos SMF batteries 200Ah, open MS rack and interconnecting cable complete all as specified and as directed by Engr-in-charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .