Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2,184Admitted-Finance CABIN NO 9 SCO 815 SECTOR 13 NAC MANIMAJRA CHANDIGARH CHANDIGARH CHANDIGARH 160101 | CHANDIGARH | CHANDIGARH | 160101 | L1 | Admitted-Finance | |
| 2 | L2₹2,800+₹616 (28.2%)Admitted-Finance 1ST FLOOR ROOM NO 111 SHIVRAJ BHAVAN 2 BM MARG ELPHINSTONE MUMBAI MAHARASHTRA 400013 | MUMBAI | MAHARASHTRA | 400013 | L2 | Admitted-Finance | |
| 3 | L3₹72,847.60+₹70,663.60 (3235.5%)Admitted-Finance A 413 ANSAL CHAMBER 1 BHIKAJI CAMA PLACE BHIKAJI CAMA PLACE SOUTH WEST DELHI DELHI 110066 | NEW DELHI | DELHI | 110066 | L3 | Admitted-Finance | |
| 4 | L4₹2.2 L+₹2.2 L (10114.5%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹2.3 L+₹2.3 L (10411.9%)Admitted-Finance SURVEY NO 106 BEHIND ELITE BOARDING SCHOOL OPP SAFEX INDUSTRIES VAVDI KHEDA GUJARAT 387550 | KHEDA | GUJARAT | 387550 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Radha Meditech L2 | Medilink Surgicals L3 | VANDANA MEDICO TRADERS L9 | Maruti Sales and Services L8 | VIKAS TRADELINKS L4 | RAGHUVEER ENTERPRISES L7 | AMENITY HEALTHCARE PRIVATE LIMITED L1 | MIRACLUS ORTHOTECH PVT.LTD. L5 | Decent Medical Equipment Systems Pvt.Ltd L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Orthochord or Fiberwire No. 2 suture on needle,sterile, disposable, | 120 | No | - | 1,140 ₹1,197 Lowest | 2,047.62 ₹2,150 | - | - | - | - | - | - |
| 2.00 | Suture Post Titanium 6.5 x 25 or 30 | 24 | No | - | - | 2,950 ₹3,097.5 Lowest | - | - | - | - | - | - |
| 3.00 | All inside meniscal repair implant system. | 36 | Kit | - | 12,500 ₹13,125 Lowest | 14,190.48 ₹14,900 | - | - | - | - | - | - |
| 4.00 | Polybutylate Coated Braided Polyester orthosuture, Size No 5, 1/2 Circle Taper Cut, 45 mm Single Needle, Ethibond, sterile foil
with single thread, box of 12 | 36 | Box | - | 17,400 ₹18,270 Lowest | 19,780 ₹22,153.6 | - | - | - | - | - | - |
| 5.00 | High Tibial Osteotomy Plate, (Puddu Type) Size 7.5 Holes with 6.5mm Cancellous Screw low profile head 2 pcs & 4.5mm Cortex Screw low profile head 2 pcs | 24 | No | - | - | 29,500 ₹30,975 | - | 15,714 ₹16,499.7 Lowest | - | - | - | - |
| 6.00 | Arthroscopic Shaver blade 4.5/5 mm | 60 | No | - | 7,900 ₹8,848 | 6,500 ₹6,825 Lowest | - | - | - | - | - | - |
| 7.00 | Mono rail external limb reconstruction system (LRS) Consisting of following 01 x Mono Rail 300 mm, 01 x Central clamp, 01 x Square CD unit 80 mm, 01 x T clamp
01 x swivel clamp, 01 x end clamp, 02 x HA coated conical pins, 04 x conical pins, 04 x Schanz pins, 01 x compatible Allen key | 12 | Set | - | - | 2,15,000 ₹2,25,750 | - | 30,000 ₹31,500 Lowest | - | - | - | - |
| 8.00 | Endobutton with adjustable length fibre wire or orthocord Loop for ACL large, for soft tissue graft fixation in femour during ACL reconstruction. | 60 | No | - | 8,932 ₹9,378.6 | 8,900 ₹9,345 Lowest | - | - | - | - | - | - |
| 9.00 | Bio Anchor 2.8/2.4,3.5,5.0 mm | 60 | No | - | 10,990 ₹11,539.5 Lowest | 12,500 ₹13,125 | - | - | - | - | - | - |
| 10.00 | Bio Absorbable interference screws 7,8,9,10,11 mm all size | 60 | No | - | 9,990 ₹10,489.5 | 7,900 ₹8,295 Lowest | - | - | - | - | - | - |
Tender Value
₹1.6 Cr
Closing Date
23 Nov 2023, 6:00 pmClosed
Commandant
Commandant Military Hospital Bhopal
Ortho Implants
2023_ARMY_625371_4
785A/MS/DGLP/PA/Orto Implants/2023-24
Open Tender
Drugs and Pharmaceutical Products
Supply
30 days
Military Hospital Bhopal
Please refer Tender Documents
6 documents required · 6 mandatory
₹0
Exempted
28 Dec 2023
16 Nov 2023
24 Nov 2023
16 Nov 2023
23 Nov 2023
16 Nov 2023
16 Nov 2023 - 20 Nov 2023
Orthochord or Fiberwire No. 2 suture on needle,sterile, disposable,
Suture Post Titanium 6.5 x 25 or 30
All inside meniscal repair implant system.
Polybutylate Coated Braided Polyester orthosuture, Size No 5, 1/2 Circle Taper Cut, 45 mm Single Needle, Ethibond, sterile foil with single thread, box of 12
High Tibial Osteotomy Plate, (Puddu Type) Size 7.5 Holes with 6.5mm Cancellous Screw low profile head 2 pcs & 4.5mm Cortex Screw low profile head 2 pcs
Arthroscopic Shaver blade 4.5/5 mm
Mono rail external limb reconstruction system (LRS) Consisting of following 01 x Mono Rail 300 mm, 01 x Central clamp, 01 x Square CD unit 80 mm, 01 x T clamp 01 x swivel clamp, 01 x end clamp, 02 x HA coated conical pins, 04 x conical pins, 04 x Schanz pins, 01 x compatible Allen key
Endobutton with adjustable length fibre wire or orthocord Loop for ACL large, for soft tissue graft fixation in femour during ACL reconstruction.
Bio Anchor 2.8/2.4,3.5,5.0 mm
Bio Absorbable interference screws 7,8,9,10,11 mm all size
Locking compresion plate, Combination hole small fragment 3.5 mm with 4 cortical and 4 locking screws ,Titanium
Locking compresion plate, Combination hole large fragment 4.5 mm with 6 cortical and 4 locking screws ,Titanium
Minifragment plate 2.7mm with 6 screws (Titanium)
Distal radius volar locking plate variable angle complete construct with 6 locking and 3 cortical screws (Titanium)
Antegrade femoral nail system complete construct (right or left) with 04 locking bolts and 01 end cap (Titanium)
Reconstruction cephallomedullary nail femur complete construct with 02 cephalic lag screw and 02 locking bolts and 01 end cap (Titanium)
Tibial nail with multiple proximal interlockin options and tip locking with 6 x locking bolts ,01 end cap (Titanium)
AO type joint spanning external fixator complete set with 04 x 250mm long SS tubes 11mm diameter ,02 x 150mm long SS tubes 11 mm diameter,08 x 5 mm self drilling or tapping schanz screws, 12 x single pin to tube clamps and 02 X tube to tube clamps
Proximal humerus anatomical locking plate complete construct with 6 locking and 4 cortical screwa (Titanium)
Proximal Tibal lateral periarticular locking plate system (Left or right) complete construct with 04 metaphyseal locking cancellous screws, 02 cortical screws, 03 locking screws (Titanium)
Distal tibia medial low profile periarticular plating system (Left or Right) complete construct with 06 locking screws and 03 cortical screws (Titanium)
DHS fixed angle barrel plate complete construct with 01 DCS lag screws ,01 compression screws , 06 cortical screw and 04 locking screws (Stainless steel 316L)
Short proximal femoral nail, Antirotation (left or right) complete construct with 01 spiral blade,02 locking bolts,01 end cap (Titanium)
4.5mm Distal femur plate Left/Right sizes 6,8,10,13H with 6 Nos. 4.5mm Locking screws,04 Nos.4.5mm cortical screws with star drive recess,2 Nos. 5.7 locking cannulated screws and 2 Nos. 6.5 locking cannulated screws with Radiolucent Minimal Invasive Zig. Plate shoulde be in sterile packing
High viscosity Bone Cement PMMA with pigment, antibiotic loaded 40 gm packet
Oscillating Saw blade
Battery operated sterile disposable Pulsatile Lavage System
Posterior Stabilised Fixed Bearing Knee with Symmetric Tibia consisting of : Cobalt Chromium femoral component, matching polyethylene fixed PS insert and modular symmetric tibial base plate compatible with stem. (All implant sizes with compatible posterior and anterior referencing instrumentation, one 40 gm packet of antibiotic cement and saw system to be provided at the time of surgery, Implant should have registry follow up data / ODEP rating. USFDA approved / EU-CE certified)
Uncemented total hip replacement system consisting of ; Primary uncemented proximally coated double taper Hip Stem- Collarless, reduced lateral shoulder double taper wedge titanium stem with slim AP dimension proximally coated available in standard and extended offset with compatible Biolox Delta Ceramic head. Primary uncemented acetabular shell with poly liner consisting of: Titanium coated primary acetabular shell with highly crosslinked/epoly Polyethylene liner in taper lock design and two 6.5 mm cancellous screws. Should be supplied with Dome and screw hole caps / Solid option. Should be compatible with a ceramic liner.(All implant sizes with compatible instrumentation and saw system to be provided at the time of surgery, Implant should have registry follow up data. USFDA approved / EU-CE certified)
Cemented Bipolar hip prosthesis with double/triple tapered cobalt chrome polished collarless femoral stem (12/14 taper); 43/44 mm, 45/46 mm ; 47/48 mm,49/50mm and 51/52mm each bipolar head-cobalt chrome outer shell with ETO sterilized UHMWPE liner and cobalt chrome femoral head, including disposable cement gun, void centraliser and cement restrictor
Shoulder hemi-replacement prosthesis (All implant sizes with compatible instrumentation and saw system to be provided at the time of surgery, Implant should have registry follow up data. USFDA approved / EU-CE certified)
Reverse Shoulder Prosthesis with option of fracture stem. (All implant sizes with compatible instrumentation and saw system to be provided at the time of surgery, Implant should have registry follow up data. USFDA approved / EU-CE certified)
Radial head replacement implants ti
Impervious stockinette sterile
Radha Meditech
Medilink Surgicals
VIKAS TRADELINKS
MIRACLUS ORTHOTECH PVT.LTD.
Decent Medical Equipment Systems Pvt.Ltd
RAGHUVEER ENTERPRISES
Maruti Sales and Services
VANDANA MEDICO TRADERS
Maruti Sales and Services
Items/26
Medilink Surgicals
Items/03
Items/04
Items/09
VIKAS TRADELINKS
Items/07
Items/11
Items/12
Items/14
Items/15
Items/17
Items/18
Items/19
Items/20
Items/21
Items/22
Items/23
Items/24
Items/30
VANDANA MEDICO TRADERS
Items/06
Items/08
Items/10
Items/25
Items/27
Items/28
Items/31
Items/32
Items/33
Items/34
Decent Medical Equipment Systems Pvt.Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BidSecurity.pdf
Additional Documents • 0.21 MB
BBQR.pdf
Additional Documents • 0.80 MB
BOQ_703560.xls
BOQ • 0.32 MB
RFP.pdf
Tender Documents • 0.41 MB
Company.xls
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .