Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.6 L+₹1.5 L (4.59%)Rejected-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹36.5 L+₹3.5 L (10.4%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹38.1 L+₹5.0 L (15.2%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹39.0 L+₹5.9 L (18.0%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
24 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
PROVN OF CERTAIN REPAIR WORK IN THE AREA OF AGE B/R-I AND AGE E/M (CENTRAL) UNDER GE (CENTRAL) DELHI CANTT-10
2023_MES_632777_3
GE/C-63/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹97,000
Yes
5 Mar 2024
16 Feb 2024
26 Feb 2024
16 Feb 2024
24 Feb 2024
17 Feb 2024
16 Feb 2024 - 17 Feb 2024
Amount
Surface dressing not exc 15 cm deep in soft / loose soil complete all as specified and as directed by Engr in charge.
Excavation in trench not exc 1.5m wide and not exc 1.5m in deep and getting out in soft/loose soil.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate as in foundation mass concrete.
M & L for nominal mix Type B1 1:2:4 (20mm graded aggregate) as in Col footing, Col up to bottom of PB & in Plinth beam complete.
M & L for nominal mix Type B1 1:2:4 (20mm graded aggregate) use as in Columns above plinth beam, tie beam, pillars, piers, posts and struts.
M & L for Formwork to sides of concrete foundations, footings, bases of columns, columns up to PB and plinth beams; and similar work; vertical or to batter Fair finished surfaces.
M & L for Formwork to sides of pillars, posts, struts, piers, columns etc fair finished surface.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
All as per item Sl No. 8 above but 8 to 10 mm dia as in stirrups, binders etc.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6m mean radious built in CM (1:4) etc complete all as specified and directed.
M&L 10mm thick rendering on any face fair faces of brick work or concrete surfaces in cement mortar 1:4 finsihed the surfaces even and smooth without using extra cement.
M&L for rendering 15mm thick on fair faces of brick or concrete surface in cement mortar 1:6 mixed with integral water proofing compound.
M&L for broken brick bats of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even, complete all as specified & directed.
M & L for 75 mm thick cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth incl filling of joints with sand and bitumen mixture in ratio of 1:3 without using extra cement, complete all as specified.
M&L for 100 mm thick PCC (1:1:5:3) type A-1 using 20 mm graded crushed aggregate as in flooring, surface finished fair and even, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of with alkali resistant priming paint complete all as specifed as direted by Engr-in-charge.
M & L for applying two coats of oil bond destember over one coat of white wall care putty on newly plastered surfaces (internal) of walls complete all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S&F aluminium ventilator partly glazed/ gauzed including frame and chanel of seciton and necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading,3mm thick glass and jali, screws etc. provision for fixing the exhaust fan complete all as specified and as directed.
M&L aluminium alloy powder coated windows including aluminium coated frames, silding track bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double revated and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter silding type with aluminium sectins as per series-A (15mm) 3 track of jindal section number for silding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrngement spring action and glazing clips joint cleats rubber gaskets etc inclding provision of 4.8 mm thick tinted frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed.
Material and labour for aluminium alloy Powder coated standard 10mm section and opening of size window grill as per approved sample and as per IS specifications complete all as specified and as directed.
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F rolled sections as in main and cross beams, truss, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L Providing cement concrete in coping type C-1 ,1:3:6 using 20mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified.
Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point.
M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 475 (part-4)-1970 and light Code Description unit rate No 429 SUB HEAD :26.0 NEW TECHNOLOGIES ANDMATERIAL reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams oer sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32nn of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) ie. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000mm to be fixed on perimeter wall/partition with the help of plastic rawl pluhs at 450mm center to center and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-charge.
S&F in repairs mild steel hood covers made out of mild steel sheets 0.5mm thick incl bending the sheet to the required shape and fixing the same etc incl adjustment of rolling shutters bracket plate incl one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
S & F for 1.0 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with bevel gear box and crank handle complete all specified and directed by Engineer-in-Charge.
Excavating in post holes each n exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceedings 25cm watering and removing surplus soil to distance n exc 50 m and making good surfac in soft/loose soils.
S&Fsteel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for fixing of 10mm dia MS bars in chain link fencing.
Fixing only chain link fencing incl line wires, any mesh, size and type to any type of standereds, rails, straining blots, etc. incl provn of binding wire.
Supply only chain link MS galvanised fencing any size or any type complete.
S&F 2mm thick fibre glass reinforced translucent plain sheeting with side lap fixed with srew on fencing vertically complete all as specified and directed.
M&L for Black Granite slab 18-20 mm thick rubbed and polished machine cut, set in cement mortar jointed with white cement complete including bedding layer 15mm thick in cement mortar 1:6 over cooking platform & making hole for gas pipe etc through precast RCC slab & granite stone etc incl rounding of exposed edges, complete all as specified.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggrgate as in coping to wall complete all as specifed and as directed.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified.
One light /Ceiling fan/exhaust fan point controlled by one switch.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 4 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 4 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified.
M&L switch Modular type 6 Amps one way 230V AC complete all as specified.
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified.
M&L switch Modular type 16 Amps one way 230V AC complete all as specified.
M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified.
Supply & Fix Modular five stepped type electronic fan regulator 2 module 230V AC complete all as specified.
M&L ceiling rose 3 phase PVC polycorbonate,isolated body.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 4 Sqmm size stranded conductor as earthwire.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 10 Sqmm size stranded conductor as earthwire.
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
M&L MCB SPN 40 Amp "C " curve.
M&L MCB SP 6 to 32 Amp "C" curve.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete.
Supply and fix 12 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 0.75 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fixing ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220 cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. Note BLDC Fan should work on existing electronic fan regulator.
Supply and Fix 100 W High efficient LED Flood light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV for fixing the light fittings on Wall fixed complete as specified and directed.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
S&F MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting.
Supply and fix 60 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete.
Supply,laying in repairs of PVC under ground XLPE insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm 3.5 core laying in trenches, fixed along wall, through GI pipe under floor complete.
supply and fix GI pipe 32 mm dia light grade , for laying in rod crossing /fixing of vertically complete all as directed.
M&L for dry river sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed by EIC. Note :- Punned thickness only shall be measured and paid as per ruling provn.
Supplying laying sub class ‘B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
S&F Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height 0.6 meter with IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles, service wire and cement work complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring with two single core FRLS stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core FRLS stranded copper conductor cable 4 sqmm for earth wire in and including medium grade PVC concealed conduit with all fittings complete all as specified and directed.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
Supply and fix Instant Hot Water Geyser 5 Ltrs capacity,3 KW with 5 Star rating corrosion proof thermoplastic external body ,withstand high pressure capacity to use in high rise buildings, ISI approved with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection complete all as specified.
M&L forming 12mm thick expansion joints in 100mm thick concrete slab and filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, grade complete all as specified and directed.
m/s VK construction company
SHREE RAM BUILD TECH
GAUTAM ELECTRIC WORKS
M/S Rohit Enterprises
R S CONSTRUCTION CO.
a.k constructions
Maninder Singh Lohia
LAMBA ENTERPRISES
M/s M M BAHL
imran construction company
M/S ANIL KUMAR
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .