Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 CrAdmitted-Finance | ₹5.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.2 CrAdmitted-Finance | ₹5.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹5.2 CrAdmitted-Finance | ₹5.2 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Md Nashir Shah L1 | M/s Ravina Enterprise L2 | M/S YUMNAM PREMKUMAR SINGH L3 |
|---|---|---|---|---|---|---|
| 1.01 | SCHEDULE ‘A’ PART-I . Construction of RCC framed structute building for installation of IRP and suitable Motor pump size 5.00x 4.00 mtrs and floor height 3.60 meter including Door, window and rolling shutter complete as per site requirement and construction of Ramp at river site for installation of motor including wrench assembly for pulling of motor excluding internal & external electrification and all as per direction of Engr in charge & drg No . DGAR/Engr/364 Sheet No. 1/1 | 20 | Sqm | 10,30,400 ₹10.3 L | 11,00,000 ₹11 L | 90,00,000 ₹90 L |
| 1.02 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting ut and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in charge All kinds of soil | 1,250 | Sqm | 5,37,500 ₹5.4 L | 3,12,500 ₹3.1 L | 5,62,500 ₹5.6 L |
| 1.03 | Construction of RCC underground sump of capacity 2,00,000 liter all as per drawings & specifications and direction of Engr in charge and drg No. DGAR/Engr/366 Sheet No. 1/2 & 2/2 | 2 | Job | 1,73,16,000 ₹1.7 Cr | 2,00,00,000 ₹2 Cr | 17,40,000 ₹17.4 L |
| 1.04 | Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) : 150 mm dia C.I. Double Flanged Pipe | 5,000 | RM | 2,85,00,000 ₹2.9 Cr | 2,55,00,000 ₹2.5 Cr | 3,75,00,000 ₹3.8 Cr |
| 1.05 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge PN - 10 Pipe, 110 mm OD (SDR-11) | 250 | RM | 9,43,500 ₹9.4 L | 4,50,000 ₹4.5 L | 5,00,000 ₹5 L |
| 1.06 | Providing and fixing PPR Unions 110 mm | 4 | Nos | 5,232 ₹5,232 | 10,000 ₹10,000 | 888 ₹888 |
| 1.07 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :110mmm | 5 | Nos | 14,260 ₹14,260 | 47,500 ₹47,500 | 225 ₹225 |
| 1.08 | Providing and fixing Non return valve with C.I. wheel of approved quality (screwed end) :110mmm | 4 | Nos | 19,008 ₹19,008 | 46,000 ₹46,000 | 268 ₹268 |
| 1.09 | Providing and fixing Suction pipe of approved quality :150mmm | 60 | RM | 39,180 ₹39,180 | 1,05,000 ₹1.1 L | 29,340 ₹29,340 |
| 1.10 | Providing and fixing foot valve of approved quality (screwed end) :150mmm | 2 | Nos | 11,882 ₹11,882 | 17,000 ₹17,000 | 9,100 ₹9,100 |
Tender Value
₹5.0 Cr
EMD Value
₹10.0 L
Closing Date
2 Jan 2026, 11:30 amClosed
DG Assam Rifles
DG Assam Rifles, Laitkor, Shillong
Provn of water treatment plant along with iron removal plant augmentation of water storage wks for HQ IGAR S at Mantripukhri
2025_ARMHA_891091_1
VIII.11014/8979/HQ IGAR (S)/Engr/OB-2025/02
Open Tender
Civil Works
540 days
Mantripukhri
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Director General Assam Rifles
₹10.0 L
29 Jan 2026
23 Dec 2025
6 Jan 2026
24 Dec 2025
2 Jan 2026
24 Dec 2025
24 Dec 2025 - 2 Jan 2026
SCHEDULE ‘A’ PART-I . Construction of RCC framed structute building for installation of IRP and suitable Motor pump size 5.00x 4.00 mtrs and floor height 3.60 meter including Door, window and rolling shutter complete as per site requirement and construction of Ramp at river site for installation of motor including wrench assembly for pulling of motor excluding internal & external electrification and all as per direction of Engr in charge & drg No . DGAR/Engr/364 Sheet No. 1/1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting ut and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in charge All kinds of soil
Construction of RCC underground sump of capacity 2,00,000 liter all as per drawings & specifications and direction of Engr in charge and drg No. DGAR/Engr/366 Sheet No. 1/2 & 2/2
Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) : 150 mm dia C.I. Double Flanged Pipe
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge PN - 10 Pipe, 110 mm OD (SDR-11)
Providing and fixing PPR Unions 110 mm
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :110mmm
Providing and fixing Non return valve with C.I. wheel of approved quality (screwed end) :110mmm
Providing and fixing Suction pipe of approved quality :150mmm
Providing and fixing foot valve of approved quality (screwed end) :150mmm
Supply, delivery, installation, testing and commissioning of Iron removing plant of 40,000LPH Capacity with allied services such as Alum dozing unit ,oxidation chamber of approved make
Schedule A Part –II (Electrification wk). Supply, delivery ,installation, testing and commissioning of 40 HP motor with 40 HP starter
Supply, delivery, installation, testing and commissioning of 20 HP motor with 20 HP starter
Supply, delivery, installation, testing and commissioning of 5 HP motor with 5 HP starter
Supply & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supply & Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 50 sq. mm
Supply, delivery, installation, testing and commissioning of 100 Amp Main switch etc. as required
Supply, delivery, installation, testing and commissioning of 63 Amp Main switch etc. as required
Supply, delivery, installation, testing and commissioning of 100 Amp Change over etc. as required
Supply, delivery, installation, testing and commissioning of 63 Amp Change over etc. as required(Make:-Havells,Cropmptom,
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
Supplying and fixing following way, single pole and neutral ,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tenderdocus.pdf
Tender Documents • 3.26 MB
BOQ_936600.xls
BOQ • 0.37 MB
Drg.pdf
Additional Documents • 1.76 MB
Download all tender documents and submit your bid