Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹27.2 L+₹3.0 L (12.3%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹27.5 L+₹3.3 L (13.5%)Rejected-Finance 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹28.0 L+₹3.7 L (15.3%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹29.5 L+₹5.3 L (21.6%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
13 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
PERIODICAL SERVICES AND REPAIR TO RCC CHAJJAS FACIA COLUMNS BEAMS AND CONNECTED ITEMS TO INTERNAL/EXTERNAL SURFACES OF BLDGS IN NHL AND OHL AREA UNDER GE (EAST) MATHURA
2024_MES_647387_1
8200-1414/E8
Open Tender
Civil Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EAST MATHURA
₹1 L
7 Jun 2024
21 Mar 2024
22 Apr 2024
21 Mar 2024
13 Apr 2024
5 Apr 2024
21 Mar 2024 - 13 Apr 2024
Amount
M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed.
M&l for preparation of old plastered surfaces of walls and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old plastered surface of ceiling and applying one coat of white wash all as specified and as directed.
M&L for Providing 1mm thick wall care putty on surfaces of wall complete all as specified and as directed.
M&L for preparation of old plaster surface of walls and applying two coats of distemper oil emulsion, white or tinted complete all as specified and as directed.
M&L for preparation of old plaster surface of walls and applying one coat of cement base paint complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
M&L for preparation of old plaster surface walls and applying one coat of exterior emulsion paint complete all as specified and as directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surface of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
Taking down Cement plaster from brick work or concrete surface etc incl raking out joints, hacking for key and scrubbing down with water etc all as specified and as directed.
M&L rendering 15mm thick on fair face of brick work or concrete surface in cement mortar 1:4 in two layer first layer shall be 10mm and second layer shall be 5mm thick mixed with liquid WPC @200 ml per bag of cement or as per manufactures Instructions and finishing surface even & smooth complete all as specified and as directed. Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 and finishing the surface even & fair complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of bricks or concrete surfaces as in ceiling surfaces in cement mortar 1:3 finished even & fair all as specified and as directed.
M&L for preperation of newly plastered surfaces of walls providing 1mm wall care putty to achieve smooth surface and applying two coats of oil bound distemper over and including a coat of alkali resistant primer using spray machine, spray hard to receive area to achieve excellent application using limited manpower complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint white or tinted over and including a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for providing damp proof layer in two coats of acrylic polymer coating consisting of 1 part of acrylic polymer liquid mixed with 2 parts of cementious powder applying at the rate of 1.40 Sqm/ Kg of mix per coat. Second coat should be applied after 4-6 hrs of first coat, 5 days curing is to be carried out to the surface before providing plastering. Note : Make of the material 'Smart Care damp block 2K' of Asian paints or equivalent from Dr Fixit/STP/CICA as approved by GE.
M&L Obliterating old writing of any description with synthetic enamel paint n.exc 0.10 sqm each to match the existing work complete all as specified and as directed.
M&L for Writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 Cm high complete all as specified and as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforecement cut as required to facilitate demolition) complete all as specified and as directed.
M&L for 50mm thick sand stone slab as in chajja/cover slab set and jointed over supports in cement mortar 1:4 complete all as specified and as directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep for fixing joist,angle, channel section and sand stone slab in chajjas upto G+2 floors and finishing face of groove with cement mortar 1:3 complete all as specified and as directed.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping as directed mixed with liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructions complete all as specified and as directed. Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
M&L for repairing the edges/corner of Chajja/roof projection and similar work by removing plaster width/girth not exceeding 150 mm and making good with 10 mm thick rendering in cement mortar 1:3 to match with existing surface complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins arches pillars etc complete all as specified and as directed.
M&L for Brickwork using fly ash old size bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) junction single (Single 'T') equal or unequal with access door complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) branch piece double (double 'T') equal or unequal with access door complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps flat iron of size 25x3mm thick provided at 1 mtr spacing complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps flat iron of size 25x3mm thick complete all as specified and as directed.
S&F in repairs 25 mm dia stainless steel alloy tubular drapery rod cut to size and fixed in position including fixing brackets, stops, rollers end caps etc. complete all as specified and as directed.
S&F in repair Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal or wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty/wooden/rubber beading in Sqm n.exc 0.50 Sqm in each pane complete all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty/wooden/rubber beading in Sqm exc 0.50 Sqm in each pane complete all as specified and as directed.
M&L for chipping of unsound/deteriorated cement concrete up to 50mm average thickness from slabs, beams, columns, chhajjas etc with manual chisel including tempering of all edges including cleaning of exposed concrete surfaces and reinforcement with wire brushes etc and disposal of debris complete all as specified and as directed.
M&L for Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slabs/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. Note :- (i) All loose unsound and cracked concrete shall be removed out side MD land. (ii) Thickness will be measured excluding plaster
Cleaning loose concrte if any all around reinforcement including from behind the reinforcing bars to give an average 10mm thick (but not less than 10mm clear air gap) and cleaning reinforcement of total rust using alka,ine rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washed with water and allowing it to dry complete all as specified and as directed. Note : (i) Length of reinforcement bars cleaned of rust all arround will be measured for payment. (ii) Thickness will be measured excluding plaster.
Applying two coats of epoxy based passivating, protecting and bonding coat of zinc rich system (Nitzinc @ primer of force and equivalent of SIKA/Dr Fixit/Pidilite/Krishna Conchem) as approved by the Engineer-in-Charge for old and new reinforcement any dia complete all as specified and as directed. Note : Payment will be passivating, protecting & bonding coat of zinc rich system will be paid separately.
Supply only epoxy based passivating, protecting and bonding coa of zinc rich system (Nitozinc & primer of fosroc and equivalant of SIKA/Dr Fixit Pidilite/BASF as approved by the Engineer-in-Charge. Note : Payment will be made for the total weight of rasine and hardner in manufacturered specified proportion.
Mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per squire matre on prepared concrete surfaces of parent meterial complete all as specified and as directed. Note :- SBR Acrylic polymer will be paid for separately.
Mixing and applying SBR latex modified cement mortar 25 mm thick in cement sand mortar in proportions of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed. Note :- Acrylic polymer will be paid for separately.
Supply only approved SBR latex from FOSROC/BASF/DR FIXIT/SIKA for bonding coat/Polymer modified cement mortor complete all as specified and as directed. Note: Rate shall be in terms of solid contents of polymer.
M&L for providing two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489:2004, Alkali & fungal esistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces including preparation of surface spray machine, spray hard to receive area to achieve excellent application using limited manpower, including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M&L for 50 mm thick cement concrete type C-1 1:3:6 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and fair (using extra cement) compete all as specified and as directed.
M&L 75mm thick cement concrete 1:4:8 type D2 (using 40 mm graded aggregate) as in sub floors, sub bases, floors and paving etc. complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of 80mm thickness M-40 grade of concrete as in floors/pavements complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L non skid cermic ENDURA coloured tiles 10mm thick (square/rectangular) area of each tile exc 0.06 Sqm but n. exc. 0.11 Sqm as in floors set and jointed in neat cement slurry & pointed with coloured cement to match the colour of tiles laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for Chequered cement concrete tiles with white cement and pigment of size 30cm x 30cm x 25mm thick rubber moulded glossey finish, set, jointed and pointed in neat cement slurry in floors over and including 15mm screed bedding in cement mortar 1:6 complete all as specified and as directed.
Dismantling timber scantlings (framed work) exc 40 Sq cm in section in any position complete all as specified and as directed.
S&F mild steel work in tubular trusses, verical posts including special shaped washer including purlins, rafters, angle cleats, fish plates, gusset plates, base/bearing plates, bolts and nuts etc. using EWR or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, hips, valleys etc complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 as in ridges/valley gutters, fixed with self tapping screws complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed .
M&L for providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint for all hights complete all as specified and as directed.
M&L for 4 mm thick Non asbestos fibre cement building boards fixed or laid on GI/aluminium framework fixed in ceiling complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamal paint over and including a coat of red oxide primer complete as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing complete all as specified and as directed.
Supplying & fixing steel tubing ,galvanised, medium grade 20 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed.
Ahmed constructions
M/s DEVI DAYAL CONSTRUCTION CO
M/S PREETI CONSTRUCTION
M/s Orient Traders
A N BUILDERS
JAGDISH PRASAD TOMAR
M/S ANIL KUMAR
BHARDWAJ CONSTRUCTIONS
M/s GLOBAL CONSTRUCTION
ISHWAR ENTERPRISES
M/s Aditya Enterprises
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .